| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft soil complete all asspecified and as directed. |
| 2 | All as per item No 1 here-in-above, but depth exc 1.5 m but not exc 3.00 m complete all asspecified and as directed. |
| 3 | M&L for Cement concrete1:4:8 type D2(40 mm graded aggregate) in foundations, filling and mass-concrete complete all asspecified and as directed. |
| 4 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all asspecified and as directed. |
| 5 | M&L for providing reinforcement cement concrete M-25 (Design Mix) (using 20 mm graded crushed stoneaggregate) in Foundations, including rafts, footings, foundation beams plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all asspecified and as directed. |
| 6 | M&L for formwork to sides of columns and similar work with rough finished surfaces etc complete all asspecified and as directed. |
| 7 | M&L for providing reinforcement cement concrete M-25 (Design Mix) (using 20 mm graded crushed stone aggregate) in Columns, pillars, piers, posts and struts complete all asspecified and as directed. |
| 8 | M&L Formwork to Formwork to edges of concrete flats, treads, breaks in floor, window cills, concrete railing, openings in concrete walls, floor and roofs n exc 20 cm wide complete all asspecified and as directed. |
| 9 | M&L for providing RCC M-25 (Design mix) (using 20mm crushed stone graded aggregate) Lintel beam . Roof beam , landings, balconies, canopies, desk slabs and the shelves and the like etc all as specified and directed. |
| 10 | M&L fly ash Brick curved on plan exc 6 metre mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 11 | M & L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all asspecified and directed. |
| 12 | All as per item No 11 here-in-above, but 5-10 mm dia instirrups, spacers complete all asspecified and as directed. |
| 13 | M&L for Rendering 15 mm thick CM 1:4 on brick or concrete surfaces finished even & smooth without using extra cement complete all asspecified and directed. |
| 14 | M&L for applying Two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces with applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete all asspecified and as directed. |
| 15 | Providing precast cement concrete louvers and jallies, 25mm thick (measured solid), including allmould- ings but excluding frame type B0complete all asspecified and as directed. |
| 16 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all asspecified and directed. |
| 17 | Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all asspecified and directed. |
| 18 | S&F only 100 mm dia PVC (SWR) pipes, single socketed, any length, with rubber rings 75 mm dia complete all asspecified and as directed. |
| 19 | S&F Rolled mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with & including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails & guides) & hanging; also fastening & fixing complete Gde Fe 410-W (Gde-E- 250)quality-A, complete all asspecified and as directed. |
| 20 | S&FMild steel, plain, black sheet thickness 1.60 mm in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, handles, hinges clout nails or rivetsand fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all asspecified and as directed. |
| 21 | M&L for preparation of new steel surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint etc complete all asspecified and as directed. |
| 22 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all asspecified and as directed. |
| 23 | M&L PCC 1:2:4 type B1 ( using 20mm graded aggregate) as in bed blocks for hold fasts including necessary from work, PCC benching, copings etc. complete all asspecified and as directed. |
| 24 | Surface excavation not exc 30 cm deep and averaging 15 cm deep in soft/loose soil and getting out complete all asspecified and as directed. |
| 25 | M&L for providing 100 mm thick cement concrete 1:4:8 type D2 (Using 40mm graded stone aggregate) as in sub base complete all as specifiedand directed. |
| 26 | M&L for cement concrete type B0, (1:2:4) (using 12.5mm graded crushedstone aggregate) as in benching/coping and the like including weathering slightly round or chamfered angles and throatingcomplete all as specified and directed. |
| 27 | M&L hardcore broken stone or boulders of gauge n.exc. 63mm deposited, spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface for path complete all as specified and directed. |
| 28 | M&L 60 mm thick machine pressed precast concrete interlocking paver block manufactured from ordinary portland cement any shape and size conforming to IS 15658-2006, M-40 Grade with grey cement and pigment including 30mm to 50mm thick cruched sand filling complete all asspecified and as directed. |