| 1 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed. |
| 2 | Returning, filling in, riddled soil including spreading levelling, watering and well ramming in layers not exceeding 25cm using soil obtained from excavation after the pipes/ fittings are laid/ fixed jointed and tested complete all as specified and directed. |
| 3 | Removing excavated soil material from site to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr from the starting point complete all as specified and directed. |
| 4 | Material and labour for laying XLPE insulated, PVC innersheathed, extruded PVC outer sheathed, LT underground cable, armoured with galvanized wire, heavy duty electric cable with stranded aluminium conductor of cross-sectional area 2 core 10 sqmm, 1100 volts grade, as per IS 7098 (Part 1) 1988, laid in trench, fixed on wall/ pole drawn through pipe etc includingof provision of lugs & testing, including taking down old LT UG cable complete all as specified and directed. |
| 5 | M&L for high density polyethylene pipes (HDPE) of 25 mm bore of pressure rating 6 kgf/cm2 for cable protection laid in trenches complete all as specified and as directed. |
| 6 | S&F smart integrated solar LED street light fitting 30 Watts with built in Mono Crystalline Panel, Lithium Ferro Phospate (LiFePO 4) battery, MPPT charge controller and PIR sensor with colour temperature 6000-6500K, 2 days autonomy with dimming profile, including connecting, testing complete including taking down old unserviceable solar LED light fitting all as specified and directed. |
| 7 | S&F EPR (Ethylene Propylene Rubber) insulated stranded copper conductor cable of cross sectional area 16 Sqmm x 4 Core, 1100 volts grade, maximum conductor temperature typically 90 degree centigrade conforming to IS 9968 (Part-1) complete all as specified and directed. |
| 8 | Taking down existing unserviceable street lights/ flood lights fittings, including necessary disconnection of electric connection and removing from site and deposited to MES store complete all as specified and directed. |
| 9 | S&F street lightbracket of length 1.20 metre made of GI pipe medium grade 25 mm bore dia.,bend to shape to fix on LT poles including MS clamps, nuts, bolts, painting with synthetic enamel paint etc including taking down old unserviceable street light bracket from pole complete all as specified and directed. |
| 10 | Supply and fixing LED street light fitting 45 Watts 230 Volt,AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connecting with 2 core PVC insulated copper cable of suitable size complete all as specified and directed. |
| 11 | Supply and fixing LED street light fitting 60 Watts 230 Volt,AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connecting with 2 core PVC insulated copper cable of suitable size complete all as specified and directed. |
| 12 | Taking down existing unserviceable post top/ gate light fittings/ decorative light fittings, including necessary disconnection of electric connection and removing from site and deposited to MES storecomplete all as specified and directed. |
| 13 | Supply and fixing post top lantern LED type 20 Watts 230 volts, AC, outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 14 | S&F sheet metal enclosure for DB SPN 2 way single door, 240 Volt when MCB to be used for ON/ OFF post top lights including taking down old DBscomplete all as specified and directed. |
| 15 | Taking downexisting unserviceable flood lights from high mast light including necessary disconnection of electric connection and removing from site and deposited to MES store complete all as specified and directed. |
| 16 | Supply and fixing LED flood light 50 Watts 240 Volt, 50 Hz, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 17 | Supply and fixing (High mast light) Phantom LED flood light 150 Watts 240 Volt, 50 Hz, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 18 | Supply and fixing (High mast light) Phantom LED flood light 200 Watts 240 Volt, 50 Hz, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 19 | S&F in repairs 3 core, 1.5 Sqmm, PVC copper cable, multistranded, drawn through inside pole from the bottom connector to fittings by providing necessary lugs including taking down the existing wire, complete all as specified and directed. |
| 20 | S&F in repairs SMC terminal box of size 273 x 136 x 113 mm (internal dimensions) made of impact resistance plastic & heat resistant materials including MCB SP 6A with DIN bar and 4 way terminal block, and fixing the box to street light pole with 25x3mm flat iron clamps, nuts and bolts complete all as specified and directed. |
| 21 | S&F in repairs LED driver for LED street light fitting with surge protection upto 10kV of make suitable for LED fitting of capacity upto 80 Watts complete all as specified and directed. |
| 22 | S&F in repairs digital electronic analogue time switch (with battery backup), 01 module, 40 Amp, 3 Pole, 230 Volt including taking down old/unsv items complete all as specified and directed. |