| 1 | Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 2 | M & L Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applyingcement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified (Payment for providing grooves shall be made separately). |
| 3 | M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge |
| 4 | Demolition of brick work or stone/boulder masonary built in cement mortar including all quoins, arches, pillars etc complete completeall as specified and directed. |
| 5 | M&L for brick work with sub class \"B\" bricks old size, straight or curved on plan exc 6m mean radius built in CM 1:6 completeall as specified and directed. |
| 6 | All as per itemabove but except bricks complete all as specified and directed. Note : Bricks obtained from demolition of brick work shall be reused after cleaning. |
| 7 | Providing & applying Rising damp-proof coating system with Single component ready to use damp-proof coating Roff Hydamp :1.SURFACE PREPARATION: Thoroughly brush and clean all laitance, loose particles such as dirt, grease, mortar droppings, release agents, efflorescence, bird droppings, etc. All large voids or hollow portions must be removed and re-plastered. Non- moving cracks having width upto 5 mm must be filled with Polymer based crack filler.2 APPLICATION: Apply the first coat of Dr Fixit Dampguard Classic with a paintbrush directly on the prepared surfaces by mixing ( 1 part base:1 part hardner: 1 part of water) . Allow to dry for a minimum 2-3 hrs. Apply one part of DAMPGUARD mixed chemical and 2 parts of OPC white cement/Birla Putty and make the Putty, apply Putty on the entire surface area. Allow it to dry for at least 3-4 hours. Apply the Final coat of Dr Fixit Dampguard Classic on the entire surface and allow the surface to air cure 48 Hrs proceeds to paint. |
| 8 | M&L for 15mm thick ready mix plastering on internal/external surface of brick or concrete surfaces complete all as per manufacturers specification, surface finished even and fair complete all as specified and directed.Note:-Integral water proofing compound will be measured & paid seperately under respective item of Sch-A |
| 9 | M&L for 10mm thick ready mix plastering on ceiling surface finishedeven and smooth without using extra cement complete all as specified and directed. |
| 10 | M&L for applying three coats of white wash on ceiling including preparation of new plastered or un-plastered surfaces, complete all as specified and directed. |
| 11 | M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primercomplete all as specified and directed. |
| 12 | M&L for Preparation ofnew plastered surfaces of walls and applying applying two coat of distemper oil emulsion (washable) on wall all as specified and directed. |
| 13 | Supply only integral water proofing compound complete all as specified and directed |
| 14 | Demolition of cement concrete (unreinforced) in any position n.exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 15 | M&L for cement concrete 1:2:4 type B-1 ( using 20mm graded crushed stone aggregate) as in steps, parapets & railings upto 60cm ht, benching, coping, roof kerbs, mud stop, roof padding, rain water pipe mouth etc and similar work all as specified and directed. |
| 16 | Taking up or down 15mm bore steel tubing and connection complete all as specified and directed. |
| 17 | All as per item Noabove but 20mm bore |
| 18 | S&F 15mm bore GI tubes medium grade, galvanised with all fittings and fixed complete to walls and ceiling or laid in floors completeall as specified and directed. |
| 19 | S&F 20mm bore GI tubes medium grade, galvanised with all fittings and fixed complete to walls and ceiling or laid in floors completeall as specified and directed. |
| 20 | S&F in repairs PVC (SWR) pipe single socket in any length with rubber ring joints fitted to wall 75 mm completeall as specified and directed. |
| 21 | S & F 75 mm bore PVC (SWR) bends with complete fittings of any radius complete all as specified & directed. |
| 22 | S&F in repairs PVC (SWR) pipe single socket in any length with rubber ring joints fitted to wall 110mm completeall as specified and directed. |
| 23 | S & F 110 mm bore PVC (SWR) bends with complete fittings of any radius complete all as specified & directed. |
| 24 | S&F110 mm bore PVC (SWR) single T with access door of any radius complete all as specified & directed. |
| 25 | S&F in110 mm bore PVC (SWR) single Y with access door of any radius complete all as specified & directed. |
| 26 | S & F 110 mm bore PVC (SWR) cowl of any radius complete all as specified & directed. |
| 27 | M&L for PCC 1:3:6 C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection( 75 mm thick ) laying in alternate ways finished even and smooth without using extra cement all as specified. |
| 28 | Demolition of cement concrete (reinforced) in roofs,floors(otherthan ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed. |
| 29 | M & L cutting holes into or through brick wall built in cement mortar superfacial area not exc 150 Sqcmand making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed. |
| 30 | S&F mild steel joist channel angle or tee sections fixed independently with out connecting plates etc of grade fe-410-0 & fe 310-0 complete all as specified and directed.. |
| 31 | S&F 5.0 cm thick sand stone slabs in sun shades, chajjas, shelves, roof slabs etc n.exc. 2m in length punched dressed on face and along exposed edges, self faced on other side and set and pointed in CM 1:4 complete all as specified and directed. |
| 32 | Taking down chowkhats or frames not exc 1.5 Sqm each with shutters completeall as specified and directed. |
| 33 | S & F for powder coated aluminium frame for door, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 34 | S&F for powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing,min. 3 nos in each door,with tower bolt 200mm 2nos in each door anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified |
| 35 | S&F 4.80 mm thick ordinary qualitysheet glass with necessary jointing cleats, glazing clips, rubber packing & anodised aluminium snap beading area n exc 0.5 sqm in each plane complete all as specified and directed. |
| 36 | S&F4.80 mm thick ordinary qualitysheet glass with necessary jointing cleats, glazing clips, rubber packing & anodised aluminium snap beading area exc 0.5 sqm in each plane complete all as specified and directed. |
| 37 | S&F figured sheet glass 3.00mm thick pin headed type and glazing with oil puttycompleteall as specified and directed. |
| 38 | S & F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 39 | S&F framed work such as grill grating etc with ends of bars shouldered or riveted or forged into spikes frame guard bars etc all as specified. |
| 40 | M&L preparation of new or previously untreated steel surfaces exc 10 cm width or girthand applying two coat of synthetic enameled paint over one coatof red oxide primer completeall as specified and directed. |
| 41 | Dismantling PVC water tanks exc 250 but n.exc 500ltrcapacity complete all as specified and directed. |
| 42 | S&F rotational moulded polyethene water storage tank 500 ltr capacity, three layer, hoisted and fixed in position including PVC cover, plug and check nuts completeall as specified and directed. |
| 43 | M&L 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) completeall as specified and directed. |
| 44 | M&L in repairs 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed ( minimum weight 210 gms) completeall as specified and directed. |
| 45 | M&L forchequered cement concrete tiles 20 cm x 20 cm x 25 mm thick, with grey cement and pigments, set & jointed in neat cement slurry and pointed with grey cement & pigmentin floors laid over and including 20 mm thick screed bedor bedding layer including dismantling existing tiles with screed bed complete all as specified and directed. |
| 46 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified as directed. |
| 47 | M&L for coloured glazed ceramic joint freee tiles in vertical surface 350x250mmx7mm / 450X350 X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles including taking down cement plaster, wall tiles and rendering 10mm thick plastering in CM 1:4 on brick wall complete all as specified and directed. |
| 48 | M&L for ceramic non-skid colouredtiles (1st quality/premium quality) 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over 15 mm thick screed bedin CM 1:6 complete all as specified and directed. |
| 49 | M & L for non skid ceramic coloured tiles (Ist quality) 7 to 8 mm thick (Square/ rectangular), area of each tile exc 0.11 Sqm but n.exc 0.18 sqm on vertical surfaces such as skirting, dado and rises to steps etc. including 10mm thick cement plaster in CM 1:4 set andset and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles complete all as specified and directed. |
| 50 | M&L for light shed vitrified ceramic tiles 10mm thick (square /rectangular), polished area of each tiles not exc 0.38 Sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in CM (1:6)complete all as specified and directed |
| 51 | M&L for vitrified ceramic light or any shade tiles 10mm thick (square /rectangular), polished (Ist quality/Premium quality), area of each tiles n\" exc 0.36 Sqm in verticle surfaces etc, laidover and including 10 mm thick plaster in cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles,complete all as specified and directed |
| 52 | M&L for vitrified ceramic light or any shade tiles 10mm thick (square /rectangular), polished (Ist quality/Premium quality), area of each tiles n\" exc 0.36 Sqm in verticle surfaces etc, laidover and including 10 mm thick plaster in cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles,complete all as specified and directed |