| 1 | Supplying and Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit ISI 16 gauge with modular type switch, modular plate, suitable GI box and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable etc. as required. |
| 3 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess, including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. |
| 4 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc. as required.. |
| 5 | Supplying and Wiring for circuit/ submain line with 2x1.5 mm² FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit ISI 16 gauge along with 1 no 1.5 mm² FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 6 | --do-- but 2x2.5 mm² + 1x2.5 mm² earth wire |
| 7 | --do-- but 2x6 mm² + 1x6 mm² earth wire |
| 8 | --do-- but 4 X 10 mm² + 2 X 6 mm² earth wire |
| 9 | --do-- but 4 X 16 mm² + 2 X 6 mm² earth wire |
| 10 | Supplying and Wiring for circuit/ submain line with 2 nos. 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit ISI along with 1 no. 1.5 mm² FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 11 | --do-- but 2x2.5 mm² + 1x2.5 mm² earth wire |
| 12 | --do-- but 2x4 mm² + 1x4 mm² earth wire |
| 13 | --do-- but 2x6 mm² + 1x6 mm² earth wire |
| 14 | Supplying and drawing 2 x 1.5 mm² sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/PVC conduit as required with connection complete. |
| 15 | --do-- but 3 X 1.5 mm² |
| 16 | --do-- but 3 X 2.5 mm² |
| 17 | Supplying and fixing of 20 mm sizes of steel conduit ISI 16 gauge along with accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 18 | --do-- but 25 mm size |
| 19 | Supplying and fixing of 20 mm sizes of PVC conduit ISI along with accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 20 | --do-- but 25 mm size |
| 21 | S/F of stepped type electronic fan regulator on existing modular switch box including connection etc. as required. |
| 22 | --do-- but modular blanking plate. |
| 23 | Supplying and fixing 3 pin,S amp ceiling rose on the existing junction box/wooden block includinl( connection etc. as required. |
| 24 | S/F of Batten/Angle holder on existing junction box including connection etc. as required. |
| 25 | S/F of 2.8 to 3 mm thick phenolic laminated Bakelite sheet including cutting as required with brass machine screw and cup washer complete. |
| 26 | Providing and fixing 125 amp, 16 KA, rating and breaking capacity TP MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. |
| 27 | Supplying and fixing of 8-way, double door prewired SP&N MCB distribution board of steel sheet for 240 volts on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 28 | --do-- but 12-way, double door |
| 29 | Supplying and fixing 4 way (4+12), double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 30 | do... but 8 way (4 + 24), double door TPN DB |
| 31 | Supplying, installation, testing and commissioning of surface/ recess mounting, vertical type, 415 volts, prewired, TPN MCB distribution board of sheet steel, dust protected, duly phosphatized and powder painted, inclusive of 200 amps tinned copper busbar, common neutral link, earth bar, din bar for mounting MCB\"s , detachable gland / knock out plate and superior make terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link and ready for installation of 8 ways (4+24) double door (but with out MCB\"s and incomer MCCB) as required. |
| 32 | Removal / Fixing off size, SPN type sheet steel, MCB distribution board, 230 volts, on surface/ recess, complete with connection, repairing etc. including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 33 | Removal / Fixing off size, TPN type horizontal / Vertical, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with connection, repairing etc. including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 34 | Supplying and fixing 5 amps to 32 amps rating single pole, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 35 | --do-- but 5 to 32 amp DP MCB |
| 36 | --do-- but 40 to 63 amp DP MCB |
| 37 | --do-- but 40 to 63 amp TP MCB |
| 38 | --do-- but 40 to 63 amp 4P MCB |
| 39 | Supplying and fixing single pole blanking plate in !he existing MCB DB complete etc. as required. |
| 40 | Supplying and fixing 25 amps rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 41 | --do-- but 63 amps DP RCCB |
| 42 | Supplying and fixing 40 amps rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 43 | --do-- but 63 amps 4P RCCB |
| 44 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure/ HDPE FRP Chamber with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 45 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 Meter bellow ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 46 | SITC of M.S. Louver/ Flap/ Shutter for Exhaust Fan 12\" (300mm) size with all fixing material, nut bolt etc. and T&P. |
| 47 | SITC of M.S. Louver/ Flap/ Shutter for Exhaust Fan 15\" (380mm) size with all fixing material, nut bolt etc. and T&P. |
| 48 | SITC of M.S. Louver/ Flap/ Shutter for Exhaust Fan 18\" (450mm) size with all fixing material, nut bolt etc. and T&P. |
| 49 | SITC of 100/5- 600/5 CT burden 15 VA, tap wound and ring type CL -1 complete with all connections including all mounting accessories in all respect. |
| 50 | SITC of 240 V, 450 MM sweep, 900 RPM heavy duty exhaust fan in existing opening including making good finish the damage with plaster and all masonary work, connection with 1.5 mm² PVC insulated, copper conductor, single core etc. |
| 51 | Supply, Installation, Testing and Commissioning of 1200 mm, service value ≥ 5.1 CM/Min/Watt, air delivery 130 CM/Min (Minimum), ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply earthing etc. complete as required |
| 52 | Supplying and embedding 40 mm dia G.I. pipe (medium B class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required |
| 53 | Supplying, installation, Testing & Commissioning of 18-22 watt LED surface mounted Batten light (System Lumen efficiency ≥120 <135 lm/W) of Powder coated die cast/ Extruded aluminium body (thickness>=1.20mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 mm² FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) |
| 54 | Supplying, installation, Testing & Commissioning of Street light 50 W LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 1000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNAtype I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching)<5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 mm² FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C |
| 55 | --do-- but 72 watt LED street light as required complete in all respect. |
| 56 | Supplying, installation, Testing & Commissioning of 50 Watt LED Flood Light, powder coated pressure die cast aluminum body (System Lumen efficacy≥120 <135 lm/W) with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching)) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 mm² FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) |
| 57 | --do-- but 100 watt LED Flood light as required complete in all respect. |
| 58 | SITC of Sensor LED tube fitting equivalent to WIPRO Cat No. LL28-221-5N-65-XX* with built in motion sensor and necessary arrangement to reduce to 30% in case of no occupancy or motion but instantly go to full light i.e. 18-20 watt as soon as some motion observed, complete with connection as required. Minimum five years warranty should be provided. Warranty certificate should be endorsed by OEM or his representative. |
| 59 | SITC of Water Heater(Geyser) rating of 50 liters 5 star complete with all connection |
| 60 | Installation of exhaust fan up to 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. after removal the old, as required. |
| 61 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 62 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 63 | Supply and laying of Copper conductor, XLPE insulated, armoured, PVC sheathed cable, 1100V grade, 3 core 2.5 mm² on existing RCC / Hume / METAL Pipe/ Masonry Duct (Trench) / cable tray with M.S. clamps etc.. of suitable size or as directed by the Engineer-In-charge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor as required etc. |