| 1 | Demolition of cement concrete (unreinforced) of any description in any position not otherwise specifically provided for complete all as specified and directed |
| 2 | S&F of machine pressed precast concrete interlocking paver blocks with grey cement and pigment, any shape and size conforming to IS 15658:2006 of 60 mm thickness M35 grade complete all as specified and directed. |
| 3 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 4 | M&L for 75mm thick PCC, type C-1, 1:3:6, (using 20mm graded crushed stone aggregate) as in floor finish the surface complete all as specified and directed. |
| 5 | M&L for Chequered cement concrete coloured tiles 300mm x 300 mm x 25 mm thick table vibrated set, jointed and pointed in neat cement slurry with grey cement and pigments as in floor over and including screed bed or bedding layer of 20 mm thick CM (1:6) as in floor, complete all as specified and directed. |
| 6 | M&Lfor Non abrasive paving (rectified endura) cement concrete coloured tiles 300x300mmx10mm thick set jointed and pointed in neat cement slurry mixed with pigment laid over 15mm thick screed bed in cement mortar 1:4 includind demolition/dismantling old surface/tiles complete all as specified and directed. |
| 7 | M&L for plaincement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in copings, PCC block for hold fast, bed plates including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed |
| 8 | Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 9 | M&L for brick work in cement mortar 1:4 of old size sub class ‘B\" bricks straight or curved on plan exceeding 6mtr mean radius complete all as specified and directed. |
| 10 | All as per description of item 9.00 here-in-above but except bricks complete all as specified and directed |
| 11 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick wallsbuilt in cement mortar 1:4 complete all as specified and directed. |
| 12 | Taking down cement plaster on brick or concrete surfacesany description including raking out joints hacking for key scrubbing down with water complete all as specified and directed. |
| 13 | M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces including scaffolding upto 7 mtr height and curing the surface complete all as specified and directed. |
| 14 | M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/L and UC resistance as per IS 15489:2004 alkali and fungal resistance, dust resistance, water repellant, crack-bridging, weather proof 1st quality exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 L/10 Sqm and including priming coat of exterior primer applied @ 0.90L/10 Sqm including preparation of new plastered surface of walls and scaffolding at any height complete all as specified and directed by Engr-in-Charge. Note : - Tint/Shade shall be approved by Engr-in-Charge. |
| 15 | Dismantling RCC posts and struts any section including taking out embedded portion in natural ground and making good disturbed surface complete all as specified and directed. |
| 16 | S&F for Mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde-E-165 complete all as specified & directed. |
| 17 | S & F in repair Galvanised, (hot dip) 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed (each line wire to be measured) |
| 18 | Preparation of new steel surfaces of any description not otherwise described, over 10 cm width or girth and providing two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 19 | Supply only Chain link MS galvanised fencing of wire mesh size 50 mm x 50 (Nominal pitch of wires), complete all as specified and directed. |
| 20 | Fixing only chain link fencing incl line wires any mesh, size and type to any type of standards, rails, straining bolts, etc incl provision of binding wire complete all as specified and directed. |
| 21 | S&F MS round bar 10 mm dia as in strands for holding chain link fencing incl hooking etc complete all as specified and directed. |
| 22 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long, 5 to 10 mm diameter of shank, complete all as specified and directed. |
| 23 | Excavation in post holes not exceeding 0.50cum getting out in Hard/dense soil, returning, filling in layers not exceeding 50 mtr and making good surfaces complete all as specified and directed. |
| 24 | M&L for PCC 1:4:8 type D-2 (using 40mm broken graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 25 | Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.(ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum. |