| 1 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 2 | Earthing with Copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 3 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm diaGIpipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required |
| 4 | Providing and fixing 25 mm X 5 mm GI strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required |
| 5 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required |
| 6 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required |
| 7 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 185 sq. mm (57mm) |
| 8 | Providing and laying in position cement concrete 1:2:4 (1 Cement : 2 Coarse sand: 4 Graded stone aggregate 20 mm nominal size) in foundation of pump, DG set eyc including form work etc as required. |
| 9 | Providing and fixing of On-Load manual changeover switch in sheet steel enclouser. Rated current 250 A, 415 V AC, 4 Pole on exixting wall including making connection etc as per direction of engineer in charge,. Make- Havells. |
| 10 | Transportion of new 01 No 125 KVA DG sets from Sector HQ Jaisalmer South to following BOP by taking all precautionary measures to avoid damage of DG set through 4 X 4 vehicle (Suitable for moving on pacca/Kachha Road/Sandy road in desert area) etc as per site requirement. |
| 11 | Considering to and fro from Dabla to Murar and Dabla to Bhagnau respectively) |
| 12 | Considering to and fro from Dabla to Prahari respectively) |
| 13 | Considering to and fro from Dabla to V/Harrel, Dabla to Jamrau and Dabla to Shekharrespectively) |
| 14 | Considering to and fro from Dabla to 21R, Dabla to KKD and Dabla to Bhawanirespectively) |
| 15 | Proving and fixing of exhaust medium class GI pipe size 100 mm, 1.5 mtr long with the help of suitable size flange, bendi/c cutting, bending & welding according to existing DG set exhaust pipe including making hole & smooth surface etc as required. |