| 1 | Schedule-A |
| 2 | Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles & stay etc, complete all as specified and as directed by Engineer-in-Charge. |
| 3 | Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed by Engineer-in-Charge. |
| 4 | Removal of excavated surplus soil to a distancen exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engr-in-charge. |
| 5 | M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm) and 18cm punnd thickness shall be paid complete all as specified and as directed. |
| 6 | M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat, complete all as specified and as directed by Engr-in-charge. |
| 7 | M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregates) for repairing of street light pole coping etc including filling in road cuts/ hard standing etc all as specified and as directed. |
| 8 | M&L complete for drilling hole with trenchless technology underhard standing /road for laying ofpipe for protection of cable etc by means of manual booklet and without disturbing the top surface or cuttingand making good the disturbed surface to the existing if any, complete all as specified and directed by Engineer-in-Charge. |
| 9 | S&F GI Tubing light grade of size 40 mm bore for LT cable protection including clamps, nut, bolts and washer etc complete all as specified and as directed by Engineer-in-charge. Make : Tata/Swastic/Jindal. |
| 10 | S&F GI Tubing light grade of size 80mm bore for LT cable protection including clamps, nut, bolts and washer etc complete all as specified and as directed by Engineer-in-charge. Make : Tata/Swastic/Jindal. |
| 11 | S&F GI Tubing light grade of size 50mm bore for LT cable protection including clamps, nut, bolts and washer etc complete all as specified and as directed by Engineer-in-charge.Make : Tata/Swastic/Jindal. |
| 12 | Disconnect the cable connection from existing LT Panel and Taking up and down the unsv cable and made necessary cable connections as per site site requirement removing old materials for taking creditall as specified and as directed. |
| 13 | earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SSR Part I completeall as specified and directed and testing on completion. Note :- Ifthe desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. |
| 14 | 16 sqmm 4.0 core |
| 15 | 25 sqmm 3.5 core. |
| 16 | 50 sqmm 3.5 core |
| 17 | 70 sqmm 3.5 core. |
| 18 | 95 sqmm 3.5 core. |
| 19 | 120 sqmm 3.5 core. |
| 20 | 300 sqmm 3.5 core. |
| 21 | Disconnecting LT supply and taking out defective LT ACB of cap 1200 to 2500 Amps of any make and rating and servicing by cleaning the fix and moving parts, removing dust particle by using high speed blower applying greese/jelly to moving mechanism and moving parts , tightening & connection complete all as specified and as directed by Engr-in-charge. Note : Spares shall be measured and paid seprately as supply only. |
| 22 | Supply & fixing micro processor based OCR relay as per existing model for ACB 630 to 1250 Amps capacitycomplete all as specified and as directed by Engr-in-charge. Make : Havells / L&T /HPL. |
| 23 | Supply & fixing shunt trip coil 380-415volts AC/DC or 200 to 250V AC/DC, complete all as specified and as directed by Engr-in-charge. Make: Havells/HPL/L&T |
| 24 | Supply & fixing closing coil 380-415volts AC/DC or 200 to 250V AC/DC, complete all as specified and as directed by Engr-in-charge. Make: Havells /L&T/ HPL |
| 25 | Supply & fixing auxillary contact block 2 NO + 2NC,complete all as specified and as directed by Engr-in-charge. Make: Havells / L&T/ HPL |
| 26 | S&F in replacement of MCCB 3 pole 63A, fixed type, breaking capcaity 16KA fixed in bus bar trunking or in LT panels, complete all as specified and as directed by Engr-in-charge.Make : Havells/Standard/Indoasian. |
| 27 | S&F in replacement of MCCB 4 pole 63A, fixed type, breaking capcaity 16KA fixed in bus bar trunking or in LT panels, complete all as specified and as directed by Engr-in-charge.Make : Havells/Standard/Indoasian. |
| 28 | S&F in replacement of MCCB 3 pole 100 A, fixed type, breaking capcaity 16KA fixed in bus bar trunking or in LT panels, complete all as specified and as directed by Engr-in-charge. Make : Havells/Standard/Indoasian. |
| 29 | S&F in replacement of MCCB 4 pole 100 A, fixed type, breaking capcaity 16KA fixed in bus bar trunking or in LT panels, complete all as specified and as directed by Engr-in-charge.Make : Havells/Standard/Indoasian. |
| 30 | S&F in replacement of MCCB 3 pole 125A, fixed type, breaking capacity 25KA fixed in bus bar trunking or in LT panels, complete all as specified and as directed by Engr-in-charge.Make : Havells/Standard/Indoasian. |
| 31 | S&F in replacement of MCCB 4 pole 125A, fixed type, breaking capacity 25KA fixed in bus bar trunking or in LT panels, complete all as specified and as directed by Engr-in-charge. Make : Havells/Standard/Indoasian. |
| 32 | S&F in replacement of MCCB 4 pole, 250 A, with Microprocessor release breaking capacity 36 KA fixed in bus bar trunking or in LT panels, complete all as specified and as directed by Engr-in-charge.Make : Havells/Standard/Indoasian. |
| 33 | M&L for painting of LT panelindoor/Outdoor type by spray painting of synthetic enamel paint after preparing surface and red oxide on rusted portion on both sidecomplete all as specified and as directed by Engineer-in-charge. |
| 34 | M&L for preparation of old painted exposed surface of steel tubular poles LT 09 mtr long with bracket etc complete inclnumbering of pole with existing size and type as under :(i) from bottom upto 1.2 mtr height and one coat of black synthetic enamel high glow paint. (ii)1.2 mtr to 1.30 mtr height one coat of white & blue luminios. (iii) 1.30 mtr height to top of the pole two coats of aluminium paint. |
| 35 | Taking down any type of street light /flood light fitting ofany size and type from existing LT pole, bldg, complete for repair and refixing thesame after repairing work complete all as specified and directed by Engr-in-Charge.(spares required for repair shall be measured and paid separately). |
| 36 | S&F in replacement of 100 wattLED street light luminaries (+/- 05 % variation)New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07,240 V ACsuitable for pole mounting ofbracket 60mm dia with all accessories and as directed by EIC. Make : Havells/Bajaj/CG/HPL/GE. |
| 37 | S&F in replacement of 150 wattLED street light luminaries (+/- 05 % variation) New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07,240 V ACsuitable for pole mounting ofbracket 60mm dia with all accessories and as directed by EIC. Make : Havells/Bajaj/CG/HPL/GE. |
| 38 | S&F in replacemetn of110 watt LEDflood light (+/- 05 % variation)energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light withhigh power COB LEDs as light source, suitable for highlighting architectural features or Area lighting. Also suitable to rough services/installations. Make:- Havells / Bajaj/CG/HPL/GE. |
| 39 | S&F time switch type Alpharex 3 D 21 astro complete all as specified and as directed by Engr-in-charge. Make: Legran/ Siemens/ABB/Havells. |
| 40 | S&F in replacement 40 Amps TP power contactor complete all as specified and as directed by Engr-in-charge. Make - Legrand Cat No-412549 or equivalent in Siemens/ABB/Havells. |
| 41 | S&F in replacement 32 Amps TPN MCB, 10KA complete all as specified and as directed by Engr-in-charge. Make - Legrand/ Siemens /schiender. |
| 42 | S&F 1.5 Sqmm three core stranded PVC insulated copper conductor FRLS cable for connection of fittings complete all as specified and as directed by Engr-in-charge.Make: finolex/ havells/ polycab |
| 43 | M&L for defect rectification electric cable for LTcables laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. including and additionalexcavation in normal alluvial strata required forexposing the cable faultremoval of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable. The fault locating equipments will be brought to site within the hours of instruction from Engr-in-Charge. Joint shall be measured and paid seprately. |
| 44 | Supply & jointing heat shrinkable straight through joint suitable for LT 1100 Volt grade XLPE cable of size 240/300 Sq mm 3.5 core complete all as specified and as directed by Engr-in-charge. |
| 45 | All as per item No. 36 here in before but suitablefor cable size 50-150 sq mm. |
| 46 | M&L for earthing in replacement of with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified includingprovision of GI stripprotected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation andearth work & connecting the earthing to an earthing test pointcomplete all as specified & directed by Engr-in-Charge. |
| 47 | M&L for repair to bus bar chamber including tightening of all nuts/ bolts and replacement of unserviceable/ melted nuts/ bolts, bus bars, thimbles as per existing type, cleaning of entire system with cleaning agent and insulating the bus bar with proper insulation complete all as specified and as directed by engineer-in-charge. Note:- a) bus bar trucking repair of one building shall be carried out block wise b) one block with 02 bus bar trucking system for both side shall be given to contractor and repair of the same bus bar shall be carried on same day (1100 hrs to 1600 hrs) to avoid any inconvience to the user. c) contractor shall arrange sufficient man power with proper safety arrangements and equipments to complete repair of bus bar system of one block on same day (1100 hrs to 1600 hrs). d) MCCB/Busbarrequired for replacement shall be measured and paid separately.e) Each side of bus trunking system considered as (G+10) one job. |
| 48 | Detecting the any type of (Mechanical/Electrical) fault of any capacities of DG Sets andany location( In side of sekhon vihar)by providing skilled tradesman & helper with necessary safety and working equipment such as multimeter, speedometerand other required tools and plants and rectified the defects on top priority basis/as and when required includingtesting complete all as specified and directed. |
| 49 | M&L for servicing ofDG Set of capacity 82.5 KVA -160 KVA in Sekhon Vihar finding out defects, cleaning dismantling of unsv parts, repairing/replacement of unsv parts, setting of valve timing and replacement of spares as required including wiring testing complete all as specified and directed by Engineer-in-Charge.Note:- Spares required will be measured under separated item here in after. |
| 50 | Supply and fixing display board for showing details of installations such as Power house, pump houses and borewells/ SOPs/ layout of pipelines etc as provided by Engineer -in-charge made out of PVC sheet of size 1.5mtrX1mtr including GI angle frame and GI sheet cover to the frame and fixing of 2 nos LED tube light fittings 20 watts, connecting electrical supply to the frame including round stainless steel pole minimum 12 feet long of suitable dia for erection on ground with PCC complete incl arrangement for dismantling the board for repair of LED Tubelights and fittings all as specified and as directed by Engineer-in-charge. |
| 51 | Dismantling of PT pump assembly fromDG set Make - kirloskarengine for repair, cleaning, serviceable, overhauling of pump assembly with necessary calibration including replacement of spares as required, complete all as specified and as directed by Engineer-in-Charge. |
| 52 | Taking out self starter 12/24 volt from the DG Set, transportation to workshop opening/disconnecting all internal connection, cleaning the same taking out burnt armature, segregation serviceable parts for re-use, rewinding of armature with existing size of copper wire. Reassembling the same with replacement of carbon brush 01 set, Beadex pinion 01 No, Half clutch assembly 01 No, Field coil 01 No, solonoid switch 01 No., commitator 01 nos, fixing the self starter on the engine at site and testing, complete all as specified and as directed by Engineer-in-Charge. |
| 53 | Disconnect the 150/180 AH battery lead connections from upto 160 KVA DG set and transport the battery to work shop for reconditioning work by using dedicated battery regenerator. Sulfation on plates should be removed by using high powered pulses, reconstruct the damaged battery post, replace the electrolyte and recharge the battery upto 24 to 36 hours to gain more than 12 volts. After completion of reconditioningwork the battery will be refix at the same generator including necessary testings complete all as specified and directed. |
| 54 | Supply & fixing for lead acid battery 12 volts 180 AH of existing type & size suitable for Gen sets upto 160 KVA. including initial charging and copper connector complete all as specified and directed by Engineer-in-charge |
| 55 | Dismantling of injector fromDG Set in Sekhon Vihar for repair, cleaningand overhauling of the same with necessary calibration including replacement of necessary parts as required, complete all as specified and as directed by Engineer-in-Charge.Note:- spares required will be measured under separate item). |
| 56 | Supply & fixingkit Injectorassembly of existing make, complete all as specified and as directed by Engineer-in-Charge. |
| 57 | M&L for distilled water for lead acid battery complete all as specified and as directed. |
| 58 | Servicing of 125/160 KVA DG setwith and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as per recommended grade & quality and testing for smooth running at rated speed complete all as per manufacturer’s specification and as directed consisting replacement of the following parts:- (i)Fuel filter-01 Set(ii)Oil filter(Spinon/Centrifugaltype)-01 Set(iii)Air filter-01 Set(iv) Engine oil- 16 Ltr(v)Coolant - 20Ltr |
| 59 | Servicing of 82.5 KVA DG setwith and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as per recommended grade & quality and testing for smooth running at rated speed complete all as per manufacturer’s specification and as directed consisting replacement of the following parts:- (i)Fuel filter-01 Set(ii)Oil filter(Spinon/Centrifugaltype)-01 Set(iii)Air filter-01 Set(iv) Engine oil- 12 Ltr(v)Coolant - 20Ltr |
| 60 | M&L for removing old unserviceable 125 KVA DG set controller display KG 934V1 and replace with new KG 934V1 controller 24 V DC for 125 KVA DG set to monitor engine operations and detect pre alarms and failures complete all as specified. Make:-Kirloskar |
| 61 | M&Lfor AMF relay digital type with LED screensuitable capacity of CTs for 125/160 KVA DG set complete all as directed and specified by Engr-in-charge. |
| 62 | Supply and Fix in replacement of High braking capacity Fuse ofcapacity 200Amp. |
| 63 | M&L for replacement of unserviceable insulated aluminium bas bar of size 25x5 mm thcikness in busbar trunking/ LT Panels complete all as specified. |
| 64 | M&Lfor solenoid switch for 125/160 KVA DG set complete all as directed and specified by Engr-in-charge. |
| 65 | S&F in replacement of SMPS based battery charger have charge rangeupto 15 watt & up to 600 watt complete all as specified and directed. Make : Exide/HTC/Magic power |
| 66 | M&Lfor fan beltfor 125/160 KVA DG set complete all as directed and specified by Engr-in-charge. |
| 67 | M&Lfor fuel pipe for 125/160 KVA DG set complete all as directed and specified by Engr-in-charge. |
| 68 | M&Lfor fuel gauge for 125/160 KVA DG set complete all as directed and specified by Engr-in-charge. |
| 69 | M&Lfor AVR for single plase /Three phase suitable for 125/160 KVA DG set complete all as directed and specified by Engr-in-charge. |
| 70 | M&Lfor VAF meter with suitable capacity of CTs for 125/160 KVA DG set complete all as directed and specified by Engr-in-charge. |
| 71 | M & L for carrying out spray painting to 82.5/125/160 KVA Diesel Engine, alternator, base frame & control panel board complete body by applying 01 coat of approved colour synethtic enamel paint over a coat of primer including taking necessary precaution to avoid any painting in measuring instruments, hoses, fuel pipe & other parts indicated by Engineer-In-Charge. |
| 72 | M&L for removing old unserviceablecontactor LC1F185 and replace with newcontactor LC1F185 plate mounted, current rating 185 amp, 3 NO auxiliary contact IP2X protection for AMF panel for 125 KVA DG set. Make:- Schneider/CG/L&T |
| 73 | M&L in replacement of emergency stop button suitable for 125/160 KVA DG set. |
| 74 | M&L in replacement of canopy lampsuitable for 125/160 KVA DG set. |
| 75 | M&L in replacement of canopy lampswitch suitable for 125/160 KVA DG set. |
| 76 | S&F in replacement high mast control panel made of minimum 1.6 mm G.I sheet with weather and dust proof, outdoor type having top canopy, single door, locking arrangement,necessary power and control cable wiring inside the panel and necessary assembly for assembling following items:- 1) 32 Amp 4 pole MCB make :- schneider electric 02 nos. ( 2) Auxilliary Contact Block front type 1NO+1NC CAF11 01 nos. (3) Auxilliary Contact Block front type 2NO+2NC CAF22 02 nos. ( 4) Indicating lamp 01 set. ( 5) Push buttons for lowering/lifting 02 nos. ( 6) Switch for selection between auto and manual.( 6) Astronomical weekly programmable time switch make havells 01 nos. |
| 77 | S&F in replacement of spreader links for MCCB 100A/125A/400A as per matching to existing complete all as specified and directed by Engineer-in-Charge. |
| 78 | M&L for opening LT panel for repairing door and its opening system including replacement of hinges, nut/bolt/washers, locking arrangements etc complete all as specified and directed by Engineer-in-Charge. Note:- cost of welding is deemed to be fit in qouted rate. |
| 79 | S&F in replacement of Thermoplastic Polycarbonate Insulated junction box (enclosures) of size 205 x 255 x 112 mm made of PVC comprising of 04 Nos aluminium bus bar 32 Amps rating fixed on porcelain insulators, earthing terminal and one MCB SP 6/10 Amp including MS bracket, nut and bolts complete all as specified and directed. Make:-Sintex/Havells/Hensel |
| 80 | Supply & Fixing in replacement of NATURE SWITCH-02 (sensor along with pre-dawn switching off timer, 4-8 hrs) & NS-INDOOR (sensor for Lux level based switching of outdoor/semi-indoor lights). Make:- Nature switch or equivalent in HPL/L&T/EE. |
| 81 | M&L for bands , straps, supports or stays for rainwater, ventilating pipes, incuding bolts, if required hooks(stay) heavy for large gates, hook and pintle hinges large hasps and staples, chains hand made sliding bolts, clamps hold fasts wall ties hooks for hanging fans, plain agnle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles confrirming to Fe-290 Gde-E-165 complete. |
| 82 | S& F in replacement of Voltmeter digital type as per existing shape and size, range 0-500 Volt. |
| 83 | S& F in replacement of Ammeter Digital type as per existing shape and size range 0-200 Amp, including suitable CT\"s. |
| 84 | Supply and fix in replacement of LED indicating lamp (Red ,Blue & Yellow). |
| 85 | M&L for mild steel chequered plate, 5mm thick or over in thickness, grade Fe-290 (Gde E-165) in available sizes for duct cover complete. |
| 86 | M&L for coarse aggregates, grading l, 40 to 90 mm size or grading 3, 20 to 50 mm size granite for spreading Electric sub stations complete all asspecified and as directed. |
| 87 | S & F in replacement of first aid box containing medical kit complete all as specified and as directed. |
| 88 | S & F in replacement of electric shock treatment board made up of flux sheet with printed standard matter in two versions(i.e Hindi & English ) standrad drawing over a layer of polythene film pasted on wooden ply board of 6 mm thick with all edges fixed with wooden beedings all as directed.Onte:- The over all size of the board shall not less than 1.0 Mtr x 0.75 Mtr |
| 89 | M & L for danger notice plate of 1.6 mm thick MS sheet,vitreous enamellers white,figures & conventional shulls,bones in singal red colour affixed with MS clamps,bolts of approvedsize for HT 25 x 20 cm size. |
| 90 | M & L for testing of earth resistance value of existing earthing pits once in a month with digital type earth tester at different locations of Sekhon vihar area up to the entire satisfaction of Engr-in-chargel & submitting the earth result all as directed. |
| 91 | Tightening and fixing in position loose hanging aluminium/GI strip of any size on wall or building roof using new insulators of porceline of approved size and fixing existing Aluminium strip on the same as existing.(Insulators will be measured and paid separately against the item in the schedule) |
| 92 | Supply and fix in replacement ofAluminiumStrip of size 25 X 3 .15mm buried/laid in trenches/fixed on wall/tower etc complete all as specified. |
| 93 | Supply & Fix in replacement of PVC insulators with nut bolts / screws for fixing of copper / aluminium strips / GI strips on wall/Roof etc . |
| 94 | M& L in replacement of test point terminal block made out of gun metal or phosphorous bronze of size 75x75x25 mm drilled & screwed including 3 hole,8mm dia 25mm long hexagonal head with nuts & washers complete as specified and directed. |
| 95 | S &F in replacemen air temination, single pointed aluminium rod 12mm dia and 300mm long all as specified and directed. |
| 96 | M& L for industrial salt for earth pit recharging all as directed by Engineer in charge |
| 97 | M& L for char coal dust for earth pit recharging all as directed by Engineer in charge. Note : Earth work will be measured and paid separately |
| 98 | M&L for replacement of burnt aluminium lugs suitable for 35 to 50 sqmm LT UG cable complete all as specifed. |
| 99 | M&L for replacement of burnt aluminium lugs suitable for 70 to 150 sqmm LT UG cable complete all as specifed. |
| 100 | M&L for replacement of burnt aluminium lugs suitable for 185 to 400 sqmm LT UG cable complete all as specifed. |
| 101 | M&L for replacement of burnt aluminium bas bar of size 50x6 mm thcikness in busbar trunking/ LT Panels complete all as specified. |
| 102 | M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers , of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified includingprovision of GI stripprotected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation andearth work & connecting the earthing to an earthing test pointcomplete all as specified & directed by Engr-in-Charge. |
| 103 | M&L in replacement ofdriver (circuit) suitable for 50 to 140 watt LED street light/flood light fittings.Make:- Havells /Bajaj/HPL/GE/Cropmtion |
| 104 | S&F in replacemetn of200 watt LEDflood light (+/- 05 % variation)energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light withhigh power COB LEDs as light source, suitable for highlighting architectural features or Area lighting. Also suitable to rough services/installations. Make:-Havells / Bajaj/CG/HPL/GE. |
| 105 | M&L for replacement of burnt aluminium bas bar of size 32x6 mm thcikness in busbar trunking/ LT Panels complete all as specified. |
| 106 | Excavation in trenches in hard/rock soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles & stay etc, complete all as specified and as directed by Engineer-in-Charge. |
| 107 | S&F in replacement of MCCB 4 pole, 400 A, with Microprocessor release breaking capacity 36 KA fixed inLT panels, complete all as specified and as directed by Engr-in-charge. Make : Havells/Standard/Indoasian. |
| 108 | S&F in replacement of MCCB 3 pole, 400 A, with Microprocessor release breaking capacity 36 KA fixed inLT panels, complete all as specified and as directed by Engr-in-charge. Make : Havells/Standard/Indoasian. |
| 109 | M & L for Servicing of servo controlled voltage stabilizer of capacity 50 KVA, 415 volt including setting of input and output voltage complete all as directed by Engineer-in-charge.Note:- Spare required for replacement if anywill be measured and paid separately. |
| 110 | Supply and fixing in replacement of the following Parts for incorporated to the items No.76.00 here-in-before complete all as specified and as directed by Engr-in-charge :- |
| 111 | Shunt Trip coil of any size |
| 112 | Cut out PCB,3-phase |
| 113 | Micro-controller PCB with connector |
| 114 | control cabling with glass fuse |
| 115 | Indication lamp, 22.5 mm dia, R - Y- B |
| 116 | Push button,12.5 dia,R -Y-B |
| 117 | Voltmeter,Analog type ( 0 - 300 V), |
| 118 | Single phase , Synchronise AC motor, 10 KG |
| 119 | RC network for 10 KG motor |
| 120 | Sensing Transformer for Digital/analogcontrol |
| 121 | Aluminium Busbar of size25x10 mmthickness. |
| 122 | Rewinding of Stabiliser buck boost transformer ,single phase. I/P -0-144 VAC,O/P- 0 -85 VAC. |
| 123 | Stabiliser carbon Brush for Dimmer |
| 124 | Rewinding of Variable voltage transformer, single phase |
| 125 | Excavation in trenches in hard/dense soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles & stay etc, complete all as specified and as directed by Engineer-in-Charge. |
| 126 | Supply & install steel tubular swaged poles Type 410 SP-31 (9.0 meter long) complete with CI base plate and finial taper plug, bolts, nuts & screws as specified. |
| 127 | M&L of PCC 1:4:8 Concrete with 40mmm aggregrate 15cm Depth in bottom of Pit for bed concrete steel tubular pole. |
| 128 | M&L PCC 1:2: 4 Concrete with 20mm aggregrate 1.5 Mtr Depth for coping of above ground level of steel pole. |
| 129 | Note:- The amount of Rs37442.00 against Schedule of Crediton Srl Page147 - 148 shall be deducted from the total amount quoted against Sch \"A\" |