| 1 | Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames) and removingcomplete all as specified and directed. |
| 2 | Taking down and removing to or from stores Chowkats or frames exceeding 1.5 Sq. M but not exceeding 4 Sq. M each (Without taking off shutters from the frame) and removing,complete all as specified and directed. |
| 3 | S&F Aluminium anodizedpowder coated sliding windows ofthree track system and provn of alu shutters (glazed and gauzed) sliding type made out of standard aluminium section and glazing with 5.50mm thickand stainless steel wire cloth of 0.36mm nominal dia of wire and average width of apperture 1.40mm complete including necessary accessories, complete all as specified and directed and as shown in Drawing No.CECZ TD/804 Sheet No. 1/3 to 3/3 dated 13-08-2021 |
| 4 | S & F powder coated (minimum thickness of powder coating 50 micron) aluminium anodised frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing, etc complete all as specified and directed. |
| 5 | S&F 4 mm thick sheet glass, ordinary quality, and sheet glass is ground or obscured or frosted on one side fixed in aluminium door/window/ventilator glazing with rubber beading complete all as specified and directed. |
| 6 | S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of apreture 1.00 mm & fixed with stainless steel wire, staples all as specified and directed. |
| 7 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc., complete all as specified and directed. |
| 8 | M & L for brick work with sub-class `B\" bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 9 | Taking down cement plaster on wall of any description incl racking out joints for key, scrubbing with water etc. complete all as specified and directed. |
| 10 | M & L for rendering 15mm thick in cement mortor 1:4 on concrete or brick wall surfaces, finished even and smooth without using extra cement, mixed with WPC @ at 3% by weight of cement (IWPC measured and paid separately) complete all as specified and directed. |
| 11 | Supply only integral water proofing compound, complete all as specified and directed. |
| 12 | M & L for rendering 10mm thick in cement mortor 1:6 on Brick wall surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 13 | M & L preparation of old decorated surfaces of walls plastered or unplastered by brooming down or steel wire brushing, scrapping down smoke soots, moulds ,moss and efflorecent salts and treading oiland greasy spots etc and applying one coat of Oil bound distemper to walls, white or tinted, complete all as specified and directed. |
| 14 | M&L for two coats of oil bound distemper over a coat of alkali resistant primer on newly plastered surfaces of walls including 3mm thick wall care putty on wall and preperation of surface complete all as specified and directed. |
| 15 | M&L for preparing new plastered surfaces of walls and applying Two coats of cement based paint complete all as specified and directed. |