| 1 | M & L for excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.. |
| 3 | M & L for PCC (1:4:8) Type D2using 40 mm graded crushed stone aggregates as in foundations ,fillings and mass concrete complete all as specified. |
| 4 | M&L for providing and laying at or near ground level factory made kerb stone of M- 25 grade cement concrete in position to the required line, level and curvature , jointed with cement mortar 1:3 , including making joints with or without grooves , including making drainage opening wherever required complete all as specified and as directed. |
| 5 | M&L for pavings, withmix of fly ash, clinker & stone dust in the proportion of 1:3:6(ie 10% fly ash, 30% clinker and 60% stone dust ) laying in layers n. exc 10cm thick, watering, ramming and compacted with hand/power roller 8 to 12 tonn roller to required camber and gradient complete all as directed by Engineer-in-Charge. |
| 6 | M&L for Hardcore using broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 7 | M & L for PCC (1:4:8) 100 mm thick Type D2 using 40 mm graded crushed stoneaggregate used as in sub base floor/pavings and finishing complete all as specified and as directed. |
| 8 | Supplying and laying of PVC underground drainage sewer system pipe bearing 160 mm dia SN 4 including jointing with couplar, bend tee as per site requirement complete laid in trenches or floors complete all as specified and directed. |
| 9 | M & L for Sand filling under floors or in foundationincluding watering and consolidation complete all as specified. |
| 10 | M & L for Machine pressed precast concrete interlocking paver block (pre-polished) any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigments complete all as specified and as directed. |
| 11 | M&L for providing precast cement concrete Type B1 1:2:4 (20 mm graded aggregates) in landings, cover slabs (for man holes etc.)in chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and as directed. |
| 12 | M&L for preparation of concrete kerb stone or plaster surface of any description not otherwise described over 10cm width or girth and applying two coat of water based floor coat paint emulsion over one coat of self priming coat emulsion by diluting with 30% to 40% watercomplete all as specified and directed by Engr-in-Charge. |
| 13 | Taking down/out unserviceable or serviceable UG Cables of any Cross Sectional Area and Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Cables, GI Pipes, etc. and keep in Safe custody for re-use, complete all as specified and as directed. (NOTE : Earth Work shall be Measured and Paid for separately under relevant Items). |
| 14 | Laying only in trenches or passing through pipe, XLPE insulated,heavy duty,galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 10 sqmm 4 core ncluding providingBrass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directedNote : Cable will be issued under Sch B free for laying only |
| 15 | Laying only in trenches or passing through pipe, XLPE insulated,heavy duty,galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 16 sqmm 4 core ncluding providingBrass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directedNote : Cable will be issued under Sch B free for laying only |
| 16 | Laying only in trenches or passing through pipe, XLPE insulated,heavy duty,galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 25 sqmm 3.5 core ncluding providingBrass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directedNote : Cable will be issued under Sch B free for laying only |
| 17 | Laying only in trenches or passing through pipe, XLPE insulated,heavy duty,galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 50 sqmm 3.5 core ncluding providingBrass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directedNote : Cable will be issued under Sch B free for laying only |
| 18 | Laying only in trenches or passing through pipe, XLPE insulated,heavy duty,galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 70 sqmm 3.5 core ncluding providingBrass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directedNote : Cable will be issued under Sch B free for laying only |
| 19 | Laying only in trenches or passing through pipe, XLPE insulated,heavy duty,galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 95 sqmm 3.5 core ncluding providingBrass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directedNote : Cable will be issued under Sch B free for laying only |
| 20 | Re-Laying/Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 10 Sqmm 4 Core including providing Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed. |
| 21 | Re-Laying/Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 16 Sqmm 4 Core including providing Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed. |
| 22 | Re-Laying/Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 25 Sqmm 3.5 Core including providing Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed. |
| 23 | Re-Laying/Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 50 Sqmm 3.5 Core including providing Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed. |
| 24 | Re-Laying/Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 70 Sqmm 3.5 Core including providing Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed. |
| 25 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soilNote : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. |
| 26 | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. |
| 27 | Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed. |
| 28 | M&L Sand Cushioning (dry) in trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid ) |
| 29 | M&L for fly ash bricks locally availablelaid dry width wise across the line of cable in trenches for protection of UG cable, complete all as specified and as directed. |
| 30 | Taking down/out unserviceable GI / HDPE Pipes of any descriptions, laid in trenches and/or fixing with Walls/Poles complete all as specified and as directed. |
| 31 | S & F 50 mm High density polyethylene pipe (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed . |
| 32 | S&F Galvanised Iron Pipe 80mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 33 | S&F Galvanised Iron Pipe 50mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 34 | S&F Galvanised Iron Pipe 100mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 35 | Labour only for Horizontal Boring for PassingProtection Pipe up to 80mm Bore (dia), under Road /Foot Path, not exc. 10.00 mtr in a Single Length, complete all as specified and as directed. Note : Pipe to be measured separately. |
| 36 | M&L Straight Through Cable Joint Kit heat shrinkable including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVC/XLPE insulated Aluminium Stranded Conductor, Nominal Cross-Sectional area 10 Sqmm to 16 Sqmm, 4 Core and Testing complete all as specified and as directed. |
| 37 | M&L Straight Through Cable Joint Kit heat shrinkable including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVC/XLPE insulated Aluminium Stranded Conductor, Nominal Cross-Sectional area 25 Sqmm to 50 Sqmm, 3½ Core and Testing complete all as specified and as directed. |
| 38 | M&L Straight Through Cable Joint Kit heat shrinkable including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVC/XLPE insulated Aluminium Stranded Conductor, Nominal Cross-Sectional area 70 Sqmm to 150 Sqmm, 3½ Core and Testing complete all as specified and as directed. |
| 39 | S & F HDPE DWC (Double Walled Corrugated) of 750N with RR, complete with all fittings of 25 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed. |
| 40 | S & F HDPE DWC (Double Walled Corrugated) of 750N with RR, complete with all fittings of 40 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed. |
| 41 | S & F HDPE DWC (Double Walled Corrugated) of 750N with RR, complete with all fittings of 50 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed. |
| 42 | S & F HDPE DWC (Double Walled Corrugated) of 750N with RR, complete with all fittings of 110 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed. |
| 43 | Material andlabour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mmmm buried directly in ground (Earthpit not less than2.25m below ground level) with top edge of theplate not less than 1.5m below normal groundlevel, connected to GI strip 32 x 6 mmasearth lead by means of bolt, nuts, check nutsandwashers of galvanised iron or steel, upto 7.5mlength, earth strip protected by andincluding 40 mm diaGI pipe (md grade) andconnected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC(1:3:6)type C1 , Precast RCC(1:2:4)TypeB1 coverslab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100mm C/C bothwayswith onehandle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm boreGI Pipe (Medium Grade) for watering, Charcoal andsalt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any typeof soil anddisposal of spoil to a distance n.exc50 m andnecessary testing complete all asshown in Electrical Plate No 3 of SSRPart-I.NOTE : 1. The unit rare includes for protectionh GI pipe of 40mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI wireincluding protection pipe,from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI wire and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate |
| 44 | Isolate, disconnect, dismantle the burnt out lugs from main switches/MCCB/ACB/Breakers and Supply and fix new lugs with crimping tool as per existing one including fixing, insulation, termination to main switches/MCCB/ACB/Breakers for the following sizes of cables complete al as directed by Engr-in-Charge. |
| 45 | 06 sqmmto 16 sqmm |
| 46 | 25 sqmmto 50 sqmm |
| 47 | 70 sqmmto 95 sqmm |
| 48 | 120 sqmmto 240 sqmm |
| 49 | M&L SS pasivated Screw Bolts (Machine Made) with Hexagonal Head at one End and screwed the other Ends, each screwed End to be fitted with Washers and One Hexagonal Nut, diameter of Shank 5 to 10mm Length of Bolt exc. 50mmcomplete all as specified and as directed. |
| 50 | M&Lfor preparation of existing surface of LT Panel by srapping down peeled off old paint, cleaning etcand applying Two coat of Siemens Grey Paint by using spray machine complete all as specified and directed by Engr in Charge.Note:- Only external portion shall be painted. |
| 51 | Supply and Fix Metal cable route indicator of height 750 mmMS Flat of 40 mm x 4 mm with Circular 100 mm diameter MS Sheet of minimun thickness 3 mm duly engraved \" LT CABLE\" including Aluminium paint over it and to be fixed 150 mm below ground level with PCC (1:3:6) (40 mm aggregate) of size 250x250x300 mmall as directed by Engr-in-Charge. |
| 52 | Dismantling existingLT panels of any type, any size carefully for reuse including necessary excavation demolition of concrete,disconnecting of earthing,cable, taking out burn out lugs,MCCBs,bus bars,insulators and other connected works ,surface levelling etc. andreinstall the LT panels after repair/replacement ofburn out lugs,MCCBs,bus bars,insulators, wiring etc including re-connection of earthing,cables with new foundation of panels,brick works,PCC works etc complete including testing all as specified and as directed by Engr-in-charge.(NOTE : Earth Work,brick works, foundation work, PCC, lugs, switch gear, metering devices, bus bar,insulators, cable for wiring etc will be Measured and Paidseparately under relevant Items as supply only). |
| 53 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete. |
| 54 | M & L for cross arms , bracing, supports , clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer, complete all as specified and as directed. |
| 55 | M&L PCC (1:3:6) type C2 using 40mm graded crushed stone aggregate as in foundation for stay set /Pole/ Panels etc including fair finish even and fir to exposed surfaces without using extra cement complete all as specified and as directed. |
| 56 | M & LPCC (1:2:4) type B-1 (with using 20 mm graded crushedstone aggregate) as copingof pole/panel including necessary form work as requiredcomplete as directed |
| 57 | M & L for brick in CM (1:6) rendering using old size fly ash bricks straight or curved on plan exceeding 6 Mtr mean radius including dismantling old structure all as specified and directed. |
| 58 | M & L for 15mm thick in cm (1:4) rendering on fair face of brick work finished even & fair complete all as specified & directed. |
| 59 | S & F in replacement Aluminium Busbars electrolytic grade of as per site required Amps and KA rating, bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding.The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. the size and thickness of busbars shall be as per sample including drilling , cutting and suitable size of galvanised or codmium plated high tensile nuts, bolts and washers etc complete all as specified and directed. |
| 60 | S&F in repairs in wiring Single core stranded Copper conductor FRLS of size 16 sqmm including copper lugs at both ends complete all as specified and directed. |
| 61 | S&F in repairs inwiring Single core stranded Copper conductor FRLS of size 10 sqmm including copper lugs at both ends complete all as specified and directed. |
| 62 | Taking down/dismantling of unserviceable LT panels complete all as specified and directed by Engineer-in-Charge. |
| 63 | Supply,designing ,install, testing & commission 3 phase and neutral, 415 volts outdoor type, CPRI type tested having certification of IEC-61439 , factory made , dust and vermin proof, cubical type LT panel of size 1.20m x 0.45m x 1.20m, with canopy fabricated from 3.00 mm thick CRCA sheet for outer shell and 2 mm thick for non load bearing with angle iron frame of 50 x 50 x 6 mm, double door, front and back openable type, double door system, hinged opening, rubber lining, locking arrangement, with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade, protection class IP-66 fully compartmentalize design with 4 Nos of bus barmade ofaluminium, 400 Amps rated (electrical grade aluminium complying with the requirements of latest BIS, colour coded), busbar extensions for cable connections of electrolytic grade.The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding.The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated pre-wired with suitable size of copper strip/copper wire with colour code for connecting out going MCCB/MCB\"s, including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection and circuit wiring for street light auto ON/OFF control timer by using desired electrical parametersPCC foundation and pedestal for fixing pillar feeder box/LT Panel with PCC 1:3:6, 15 cm thick in foundation, brick (Fly ash) / PCC block work in CM 1:6, rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified with supply and fixing the following accessories including taking out the existing one : |
| 64 | (A) IncomingMCCB200 Amps rating,FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 36 KA --- 01 Nos. (B) Outgoing(b) MCCB40 Amps rating,FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 16 KA --- 03 Nos.(c) MCCB25 Amps rating,FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 16 KA --- 05 Nos(d) MCCB16 Amps rating,FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 16 KA --- 03 Nos(e) Digital voltmeter 0-500 volt with selector switch -01 No (f) Digital amp meter 0-100 Amp with set of current transformer of suitable rating and selector switch -01 No (g) Indicator lamp (RYB) LED type - 01 set(h) Control MCB 2.0 Amps SP- 03. Nos |
| 65 | All as per BOQ Item No 64.00here-in-before butwith the following incoming and outgoing accessories :-BUS BAR4 Nos of bus barmade ofaluminium, 250 Amps rated (electrical grade aluminium complying with the requirements of latest BIS, colour coded), busbar extensions for cable connections of electrolytic grade(A) IncomingMCCB125 Amps rating,FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 16 KA --- 01 Nos. (B) Outgoing(b) MCB25 Amps rating,TPN ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 10 KA --- 03 Nos.(c) MCB16 Amps rating,TPN ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 10 KA --- 04 Nos(e) Digital voltmeter 0-500 volt with selector switch -01 No (f) Digital amp meter 0-100 Amp with set of current transformer of suitable rating and selector switch -01 No (g) Indicator lamp (RYB) LED type - 01 set(h) Control MCB 2.0 Amps SP- 03. Nos |
| 66 | All as per BOQ Item No 64.00here-in-before butwith the following incoming and outgoing accessories :-BUS BAR4 Nos of bus barmade ofaluminium, 500 Amps rated (electrical grade aluminium complying with the requirements of latest BIS, colour coded), busbar extensions for cable connections of electrolytic grade(A) IncomingMCCB250 Amps rating,FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 36 KA --- 01 Nos. (B) Outgoing(b) MCCB63 Amps rating,FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 16 KA --- 02 Nos.(c) MCCB40 Amps rating,FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic settingIcs-100 % Icu , service breaking capacity 16 KA --- 04 Nos(d) Astronomical Timer Switch 1 outlet 16 A-250V,vertical dial N/O contact,power supply 230V,50/60Hz,three position override switch \"ON-AUTO-OFF\" on front panel-01 Nos, 25A ,2 NOContactor 3 phase, with 230V coil-01 Nos, 32 A MCB TPN-01Nos with suitable relay and other accessoris .(e) Digital voltmeter 0-500 volt with selector switch -01 No (f) Digital amp meter 0-100 Amp with set of current transformer of suitable rating and selector switch -01 No (g) Indicator lamp (RYB) LED type - 01 set(h) Control MCB 2.0 Amps SP- 03. Nos |