| 1 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 1.5 sq. mm |
| 2 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 4x2.5 sq mm |
| 3 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 4 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 5 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connection etc. as required |
| 6 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required |
| 7 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 8 | Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. (a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm |
| 10 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 11 | LED FloodLight, powdercoatedpressurediecastaluminum (Systemlumenefficacy>135 lm/Watt)Supplying,installation,Testing&CommissioningofFloodLight,powdercoatedpressuredie cast aluminum body with built in or separatedriver as per the requirement with Driver efficiency >85%,Input voltage:Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 degto 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P.F.≥0.95,IP-66,IK-10,CRI>80,undervoltageandovervoltage protection, EMI-EMCasper CISPR-15,lenses for beam angle 30 deg 120deg as per the application and the project requirement deg., suitable tiltable fitting, life time (LED,Driver & electrical circuitry) of minimum 50000Burning Hours with 70% of initial Lumenmaintained tilllife ends as perLM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K(AsperANSIBin), SDCM(Standard Deviation ColorMatching) <5, Maximumpowerconsumptionshouldnotmore than thespecified rating and Fixture shall be ofrelevant BIS standardcompletein allrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulated copper conductor single core cable and earthing etc. as required withMinimum 5 year OEM warranty.System lumen efficacy>135lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequired forLED fixtures as per BISshall be submitted. Shape size and CCT shall beas approved by Engineer-in-Charge as per requirement. (Thermal management:heatsinkofaluminumhousing such that LED junctiontemperature shall not rise above 90°C). 100 watt |
| 12 | LED Streetlight fixture, powdercoatedpressurediecast aluminumbody(Systemlumen efficacy >135 lm/Watt) Supplying,installation,Testing&CommissioningofStreetlightLED fixture, powdercoated pressure die cast aluminum body with built in orseparate driver as per the requirement with Driver efficiency >85%, Inputvoltage:140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95,IP 66,IK-10,CRI>80,undervoltageandovervoltageprotection,EMI EMCasper CISPR-15, lenses for beam angle as per IESNA type I/II/III asper the width of the road and the project requirement., suitable to fit in up to65mm dia pipe, life time (LED,Driver & electrical circuitry)ofminimum50000BurningHourswith70%ofinitial Lumenmaintained tilllifeends as per LM80 extrapolation IES TM-21-11 report,CCT 3000°K /4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(StandardDeviation Color Matching) <5, Maximum power consumption should notmore than the specified rating and Fixture shall be ofrelevant BIS standardcompleteinallrespecti/cconnectionswith1.5sqmmFRLS,PVC insulatedcopper conductor single core cable and earthing etc. as requiredwith Minimum 5 year OEM warranty.System lumen efficacy>135lm/Wattoutput . LM79 & LM80 Test reportfromNABLlab foralltestingrequired forLED fixtures as per BISshall be submitted. Shape size and CCT shall beas approved by Engineer-in-Charge as per requirement. (Thermal management:heatsinkofaluminumhousing such that LED junctiontemperature shall not rise above 90°C).1.14.8 - 30 watt |
| 13 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm |
| 14 | Fabrication, supplying and fixing class B galvanised double overhang arm bracket made out of 250mm long galvanised top tube with cap and 1000mm long 32 mm dia galvanised pipes with tightening bolts complete as required. |
| 15 | Fabrication, supplying and fixing class B galvanised single overhang arm bracket made out of 250mm long galvanised top tube with cap and 1000mm long 32 mm dia galvanised pipe with tightening bolts complete as required. |
| 16 | Fabrication, supply & erection of 5.0 mtr height , minimum 3 mm thick , bottom dia of 130mm & top dia of 70mm , base plate of size 225 x 225x 12 mm thick flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor - 4 nos. & shorting links on DIN channel i/c providing and fixing DIN channel of suitable length,, 6 Amp. SPMCB \"C \" curve characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be either embossed or rivited plate on the pole. Galvanization as per relevant IS. code etc as required. |
| 17 | Supply and fixing of hot press sheet moulded compund (SMC) fire retardent (temp. resistance up to 200 C), IP 55 weather proof pole window door suitable for 12 M semi hight mast pole etc as req. |
| 18 | Supply and fabrication of pole protection system made up of 8 SWG steel wire mesh of size 25mm x 75mmrectangualr with 50 mm x 50mm x 6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system insuitable quality of CC etc. |
| 19 | Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm (L) ×450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 960 mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia1400 mm (approx) -6 nos.(with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts 16 mm dia,600 mm long, J type i/c 2 nos. template anchor plates of size 225mm×225mm×3mm and providing DWC HDPE for cable entry and exit as required for 3 m and 5 mtr pole. |