| 1 | Supply, fixing, testing and commissioning of CESCOM / BESCOM approved 11KV, 200Amps, GOS set with ceramic insulator. (ABI Make). making good all complete as required as per the direction of Engineer-in-Charge. |
| 2 | Supply, fixing, testing and commissioning of CESCOM / BESCOM approved 11KV HG fuse unit set (comprising of 3 Nos.). making good all complete as required as per the direction of Engineer-in-Charge. |
| 3 | Re-surfacing and removal of existing 40mm graval stone at 950KVA HT Electrical yard includingmaking the soil surface even, chemical treatment of soil for removal of grass & shrubs all complete as required including transportation of old 40mm jelly available with (approximately 150 cubic feet) in the campus premisis and supply and spreading of old and new 40mm quality gravel stone of 100 cubic feet all complete as required as per the direction of Engineer-in-Charge. |
| 4 | Earth work (at 600KVA D.G. Set / HT Spun Pole / SCST Associate DP Structure location) in surface excavation not exceeding 30cm in depth but exceeding 1.5m in width as well as 10sqm. On plan including getting out and disposal of excavated earth upto 50m and lift upto 1.5m making good all complete as required as per the direction of Engineer-in-Charge. A) All kinds of Soil. |
| 5 | Providing, laying, spreading and compacting graded stone aggregate (size range 53mm to 0.075mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub-base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. (at 600KVA D.G. Set / HT Spun Pole / SCST Associate DP Structure location). |
| 6 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. A) 40mm thickwith 20mm nominal size stone aggregate making good all complete as required as per the direction of Engineer-in-Charge. (at 600KVA D.G. Set / HT Spun Pole / SCST Associate DP Structure location) |
| 7 | Providing and fixing GI Chain link fabric fencing (For 950/400KVA HT Electrical Yard) of required width in mesh size 25 x 25mm made of G.I. wire of dia 3mm including strengthening with 2mm dia wire or nuts, bolts and washers as required all complete as per the direction of Engineer-in-charge. |
| 8 | Steel work (MS Flat and MS Angle etc.) welded in built up sections / framed work(For 950/400KVA HT Electrical Yard), including cutting, hoisting, fixing in porition and applying a priming coat of approved steel primer using structural steel etc., as required. In gratings, frames, guard bar, ladder, railings, brackets, necessary repair of gates and similar works as required all complete as per the direction of Engineer-in-charge. (Item related to Sl. No. 5) |
| 9 | Painting of chain link fencing / Gate and Structure (400KVA HT Electrical Yard) with aluminium paint of approved brand and manufacture to give an even shade. Two or more coatsas required all complete as per the direction of Engineer-in-charge.Make : Asian / Reputed make. |
| 10 | Scrapping, cleaning including supply and painting with 2 coats of Red oxide paint and 2 coats of Alluminium paint of HT GOS 2 PoleStructure / Spun Pole Structure, replacement of defective insulators, corroded bolt and nuts with SS, washers, PG clamps etc. if any, earthing connections cleaning of rusted portions making good all complete as required as per the direction of Engineer-in-Charge. |
| 11 | Dismantling of existing worn out switches, fuse untis, etc., and depositing to the scrap yard and disposal of debris (existing and new) all complete as required as per the direction of E-I-C. |
| 12 | Trimming of branches of trees adjacent to the HT yard / HT Line of 950/600/400 KVA Transformer using crane and skilled man power (taking prefer HT Line shutdown)per the Direction of E-I-C and clearing of all the obstacles at different HT/LT locations by observing safety / security measures making good all complete as required as per the direction of Engineer-in-Charge. |
| 13 | Servce and Overhauling, reterminations of HT Cable end terminations, fixing necessary Lugs using SS bolt and nuts with washers making good all complete as required as per the direction of Engineer-in-Charge. |
| 14 | Supply and fixing of 11KV Danger Sign and Signal Boards in 3 languages. (Kannada, Hindi and English). As per standard Engineering practice all complete as required as per the direction of Engineer-in-Charge. |