Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Chipping loose concrete and Exposing existing RCC Columns, beams, slabs,l intels,pardis etc. including plaster beyond main reinforcement carefully by means of chisel and hammer or mechanically including necessary double scaffolding ,erecting horizonal platforms at working levels to collect the debris, proping with top and bottom runners as directed stacking the debris in the compound as directed and caring away the same outside the premises etc. complete. |
| 2 | RELIEVING STRUCTURAL MEMBERS Relieving structural members such as column, beam and slabs of their superimposed loads partially or fully by provison of adjustable steel props, frams etc. including providing necessary timber runners,bracing , jacking up arrangement all complete to the satisfication of Engineer incharge(Removing and redoing of brickwork, if required ,shall be paid separately.) |
| 3 | Chipping of existing loose, damaged concrete from RCC members of all affected RCC Columns, Beams, Slabs and Chajjas on External and internal facades etc beyond main, carefully with chisel and hammer providing and applyingRust passivater of approved make to existing reinforcement bars including wire brushing of reinforcement,cleaning washing of concrete etc complete allas directed.Providing and applying two coats of rust preventor slurry made out of \" approved makes and cement in proportion 1:1:5 to existing reinforcement bars as directed complete.Providing and applying bonding coat of slurry made out of approved make and cement in proportion 1:1 to concrete and e/f substrates complete as directed .Providing and applying Polymer modified cement mortar in Required proportion(1:5:15) to RCC members including hand packing,curing and making the surface rough for plastering. |
| 4 | FILLING AND REINSTATING OF SEPARATION CRACKSOpening the Separation cracks at the Juction of RCC and Masonry where ever directed and instructed into \"V\" Grooves 2\" to 3\" from the either side of the cracks by carefully marking the areas to be opened up using a cutting machine and skillfully Chiseling with a well sharpened chisel and hammer as directed including wire brushing and washing of concrete Substrata and masonry wall with water jet to the surfaces thus prepared to the entire as instructed and directed. |
| 5 | Moistening the cracks ,providing and applying primary/ bonding coat of slurry and cement in proportion 1:1 to surfaces prepared as instructed and directed. Filling the cracks /Grooves by Providing and applyingPolymer modified cement mortar of approved make in Proportion of 1:5:15 (polymer: Cement:Graded sand/quart/sand ) on the prepared surfaces and finishing it in the level with the existing plaster including hand packing curing and making the surface similar to the external plastering using wooden floats/ punch etc.complete as per specified and directed. |
| 6 | Drilling holes of required size upto 16mm Diameter and up to 50mm depth in concrete and cleaning the same as directed. |
| 7 | Providing and fixing 12mm diameter aluminium / PVC injection nipples and securing the same as directed & Providing and injecting cementitious grout using additive at the rate of 225 grams per bag of cement and usng suitable mechanical gun / pump including mixing etc complete. |
| 8 | Providing &fixing epoxy dipped shear keys of 10mm dia and 4\" to 6\" length in columns before jacketing Micro concreting as directed. |
| 9 | Providing and laying super fluid Microconcrete of approved make in beam bottoms, columns,slab etc including mixing with 5mm to 10mm size aggregates waterproof ply wood/ steel plate shuttering, pouring, temping, Consolidating, curing etc complete as per Manufacture\"s specification and Consultants instructions.The item shall be paid on actual consumption of Micro concrete. |
| 10 | Glass fiber Wrapping system : Provision & laying applying Glass Fiber sheet wrap at structural members including surface prepartion: Grinding/ Moulding concrete substrate ,cleaning it with wire brush, removing oil, laitance if present, rounding sharp edges to min 25mm radius etc,complete.Profiling :Applying PRIMER on prepared substrate, filling holes and uneven surface with PUTTY etc, complete.Wrapping the Glass fibre wrap to voids etc.Repeat the same procedure for multiple layer with interval of 8 hours.Sand pasting:Applying saturant,rectify air voids if any ,paste the river sand on it to make surface rough to take any further finishes.(Mode of Measurement:Per Sq.Mt of fiber consume and not on application and not on application of surface area.) |
| 11 | Providing, cutting, bending and fixing Additional Reinforcement in postion steel reinforcement of specified required sizes and shapes in the form or main rebars, stirrups & rings,distrubtion rebars tec.and tying them to shear connectors using GI Binding wire.The additional rebars should be coted with TWO coats including Anti Corrosive protective coating & dry sand to be sprinkled on second coat including tying with Annealed Binding wires, providing cover blocks of appropriate sizes etc complete as specified and instructed by the Consultants. |
| 12 | S&F hard drawn steel wire fabric cut to length bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm dianot exc. 4 Kg/sqm complete all as specified and as directed |
| 13 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings complete all as specified and as directed |
| 14 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed |
| 15 | Dismantling mild steel work of any description not otherwise provided for complete all as specified and as directed |
| 16 | S & F Mild steel roof trusses (framed), Trussesd, purlins, crane grantries, rails and framings and heavy bracket framing (Beam,tee, angle, channel or flat sections) confrming to Fe 410-Wincluding cleats,distance pieces etc complete all as specified and as directed. |
| 17 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed |
| 18 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store complete all as specified and as directed.(measured overall as fixed along the centre line over fittings and accessories) |
| 19 | S&F PVC Rain Water Pipe150 mm diaincluding all fittings, head , shoes, branchesfixed in wall including joint with PVC adhesive complete all as specified and as directed. |
| 20 | S&F PVCplain bends 150 mm bore complete all as specified and as dirtected |
| 21 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets complete all as specified and as directed |
| 22 | Supply & Fixing of Fibre Acoustical Suspended Ceiling System with ANF (Board) edge tiles with 24mm exposed grid. The tiles should have Humidity Resistance (RH) of 90%, NRC 0.5, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 34%.The tile shall be laid onwith 24 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15.34Kgs/M2 & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per sqm and need to be installed with Suspension system of approved make. The Tile & Grid system used together should carry a 10 year warranty complete all as directed by Engineer in Charge. |
| 23 | Providing and fixing factory made uPVC white colourcasement (Openable) Door made of extruded profilewilh wall thickness of 2.3mm ( + -0.2mm). Windowprofile with hollow section with mitlti chamber, frame(60mm x 58mm), sash (60mm x 78mm). T profile (Onevertical length in between two shutters) (60mm x74mm). Glazing bead (35mm x 20mm) will be miteredcut and fusion welded at all corners, includingdrilling ol holes for fixing hardwareand drainage ofwater etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steelFrame (28mm x 21.5mm), sash (31mm x 27mm), Tprofile (27mm x 17mm) to be inserted in requiredprofile, frame will be fixed to the wall wilh 8mm x100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated).Corner striker. Secondary Strikers. Cylinder. Doortransmission gear made of mild sleel with multi pointlocking system with strikes. 3D Hinges of zinc alloyed(white powder coated) [and 5mm thick glazing withselected quality glass complete all as specified and as directed(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connectedaccessories. Net opening will be measured forpayment purpose.) |
| 24 | Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames) complete all as specified and as directed |
| 25 | Taking down chowkat or framesexc 1.5 sqm but n. exc 4 sqm each (w/o taking ofF shutters from the frame ) comlete all as specified and directed. |
| 26 | Taking down shutters of any description exc 1 sqm and n exc 2 sqm comlete all as specified and directed. |
| 27 | S & F 30 mm thick second class hard wood, plain framed ,factory made panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers supplied and fixed to chowkhats complete all as specified and as directed. |
| 28 | M & L for Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and as directed. |
| 29 | S&F powder coated aluminium door and window shutter and frame any type (sliding or openable) and other similar work etc 60 micron section, including all necessary roller wheels for window, cleats , handle, door stoper, handle, locking arrangement,Mortice lockand arrangements to receiveglass/ prelaminated particle board with aluminium beading and stainless steel screw incl cost of rubber gasket beadings etc complete sealing between frame & wall with epoxy sealing compound complete all as specified and as directed. (The weight of rubber gasket beading will not be measured and paid, glass and prelaminated particle board will be measured and paid seperately) All sections shall be as approved by GE |
| 30 | S&FPowder coated aluminium grill of design DG-104 pattern, made out of 10mm dia rod fixed with and including standed aluminium frame of \"F\" section of size 23.4x15.3x1.4 mm thick all as per manufacturer\"s instructions complete all as specified and directed |
| 31 | M&L for factory made single extruded WPC (Wood polymer composite) solid plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rise husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasitcity 850 N/mm2 and resistance to spread of flame of class A catagory with property of being termite/ borer proof , water/ moisture proof and fire retardent and fixing with stainless steel butt hinges of required size with necessory full body threaded star headed counter sunk SS screws all as per direction of Engineer in Charge |
| 32 | S&F Factory made 100% solid wood plastic(WPC) Decorative Door Frame,single rebate of size 75mm x 50mm made from wood plastic composite(single extruded process) material with density 780 Kg/Cum complete all as specified and directed. |
| 33 | M&L 12 mm thick Prelaminated particle board, exterior grade, prelaminated both sides with decorative choice lamination & other side balancing white lamination, fixed with screws to timber/aluminium frame work in cupboard shutters, partitions, shelves, pelmet boxes or narrow widths and similar work. |
| 34 | S/F 18 mm thick single side prelaminated woodgrain solid PVC sheet suitablely fixed in shelves; Partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work with all fittings and locking arrangements as per direction and specifications. (Note : SS Auto hinges, 100mm Long facny SS Handle concaeled lock included in unit rate) |
| 35 | S & F 200 mm long Aluminium, anodised, barrel tower bolts of extruded sectioncomplete all as specified and directed. |
| 36 | S&F butt hinges medium weightstainless steel 100 mmsize complete all as specified and directed. |
| 37 | S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and as directed |
| 38 | S & F Aluminium alloy, anodised, sliding door bolt 300mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 39 | S & F in repairs of floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with overall length of vover plate 140 mm complete all as specified and directed. |
| 40 | S & F Aluminiumalloy wire mesh, 0.45 mm dia of wire and average width of aperture 1.40 mm and fixed withstainless wirestaples in repairs complete all as specified and as directed |
| 41 | S & F incurtain rails Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. |
| 42 | S&F 4mm thick sheetglass ordinary quality exceeding 0.5 sqm each pane complete all as specified and as directed |
| 43 | S&F aluminium (die cast) body door closer hydraulically regulated designation No 3, universal type suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed in repairs complete all as specified and as directed |
| 44 | Dismantling/Taking out existing hessain base felt of any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and levelled complete all as specified and as directed by Engr-in -charge. |
| 45 | M & L for 10mm thick rendering in CM (1:4) mixed withintegral water proofing compound over rooftop surface incl filling all cracks by forming groove of 5mm x 5mm finished to even & smooth w/o using extra cement. Note :- Integral water proofing compound will be measured and paid seperately |
| 46 | M&L for fiber reinforced elastomeric liquid applied water proofing membrane , formulated with PU hybrid polymers and reinforcing acrylic fibers and can bear upto 10 bar hydraostatic pressure damp proof of approved make having sunreflective index (SRI) of 106.59 on top concrete roof in three coats @ 10.8 litre/ 10 sqm . One coat of self primingelastomeric , water proofing liquid (dilution with water in the ratio 3:1) and second coat of undiluted elastomeric water proofing liquid followed by 3rd and final coat of undiluted elastomeric water proofing liquid ( dry filim thickness of complete application systems not less than 600 micron with water proofing warrenty 12 years. Prior to all this activity surface preparation to be done by pressure washer to remove dust , algae, fungus, oil, grase etc and crack filling bytextured crack filler of approved make upto 10 mm wherever required and bigger crack should be filled with polymer modified cement. On tile mosaic surface useterrace tile primer for better adhesion. the rate quotedis incl of all material with wastage labour , tools tackles consumable, scaffolding etc. |
| 47 | Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed |
| 48 | M&L for 25 mm thick Cement concrete type B1, 1:2:4 (using 20 mm graded granite stone aggregate) in roof for maintaining proper slope to avoid waterlogging all as specified and directed |
| 49 | M&L for 100 mm thick Cement concrete type B2, 1:2:4 (using 40 mm graded granite stone aggregate) in flooring/ hard standingcomplete all as specified and as directed |
| 50 | M&L for 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm gradedstone aggregate) in subbase, finished even complete all as specified and directed. |
| 51 | Dismantling of stone slabs and tiles of any description or thickness in floors/dadoetc laid bedded and pointed in any mortar complete all as specified and directed. |
| 52 | M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 53 | M & L for Green Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) includingpointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and as directed |
| 54 | M & L Providing, supplying and installation of 8 Layer acrylic synthetic flooring for basket ball court (3 to 4 mm thick) over plain cement concrete with following stages given below:- PATCH :- 100% Acrylic based emulsion to repair cracks of concrete and asphalt pavement. It should be carried out after 30 days from the date of placement of concrete.PRIMER-100% Acrylic Unic Floor based emulsion to improve bond of acrylic court system to the concrete or asphalt surface. RESURFACER:- 02 layer of Acrylic Resurfacer 367-30 for filling and smoothing asphalt or concrete surfaces in preparation for Acrylic ITF Approved tennis court system. And fills the surface chips,voids and conceals repair while providing a smooth surface for colour coating.CUSHION COAT:- 02 Layer of Acrylic Floor cushion for asphalt or concrete surfaces in preparation for acrylic ITF approved system.ULTRA CUSHION COAT:- 02 Layer of Acrylic Floor cushion for asphalt or concrete surfaces in preparation for acrylic ITF approved system.PRECOAT:- 2 layers of Acrylic based textured tennis topcoat. Ideal for color coating tennis and basketball courts and other sport pavement surfaces complete all as specified and directed.[Note:- Acrylic Synthetic Flooring work of Basketball shall be carried out only after30 daysof placement of concrete , repairing of cracks of concrete and asphalt surface , ] |
| 55 | Provn of Basketball poles in channel steel with 33 mm acrylic back board and spiring action slam dunk rings and net as per NSAI incl necessary excavation, foundation, pcc, painting and nut & bolts complete all as specified and directed by Engr-in-Charge. |
| 56 | M & L for painting lines, dashes, arrows, letters, etc. on roads, pavements and the like exc 10 cm wide with road marking paint, white or golden yellow complete all as specified and directed. |
| 57 | Supply and installation of International standerd badminton movable pole |
| 58 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises |
| 59 | M&L for joint free Coloured Non skid ceramic tiles light/dark shade 7 to 8 mm thick(Square/rectangular) area of each tile exeeding 0.18 sqm but not exe 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over & incl 15 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 60 | All as per item No. 61but as in skirting/dado and over 10 mm thick backing coat in CM 1:4 |
| 61 | M&Lfor coloured Glazed ceramic tiles in vertical surfaces 300 x 200 x7 mm/ 450 x 300 x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to matchover & incl.10 mm thick rendering in CM 1:4.complete all as specified and as directed. |
| 62 | Dismantaling water tanks and removing to store exc 500 but n. exc 1000 ltrs complete all as specified and as directed |
| 63 | S&F rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in positioninc 20mm bore PVC float valve all as specified and directedin SSR Pt I |
| 64 | Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia complete all as specified and as directed |
| 65 | All as per item No. 66abovebut 25 mm diacomplete all as specified and as directed |
| 66 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 20 mm. |
| 67 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 25mm. |
| 68 | S&Ffancy type chromium plated 20 mm bore stop valve/ angle cock cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 69 | S&F of Wash basins 550x400mm vitreous china (flat back type) any size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe(32 mm) but including waste fittings complete all as specified and as directed |
| 70 | S&F of600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed |
| 71 | S&F of PVC valveless, syphonic action type flushing cistern, lowlevel , white, with inlet ball valve, float and handle including brackets 10 litres capacitycomplete all |
| 72 | S&F of Vitreous China wash down water closet pan (Pedestal pattern) white complete incl seat and cover, flush pipe incl all joints complete all as specified and as directed |
| 73 | S&Ffor hand shower (Health faucet) dia 8mm 1 mtr long flexible tube and wall hook complete all as specified and as directed |
| 74 | S&FSoap dish, of material brass with glossy finish complete all as specified and as directed |
| 75 | S&F Aluminium anodised Tubular towel rail, 20mm dia, D type, 60cm long between flangescomplete all as specified and as directed |
| 76 | S&F of Vitreous China half stall urinals, white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, magnum urinal spreader,pointing around urinal back in cement; flush pipe, grating and Union for discharge pipecomplete all as specified and as directed |
| 77 | S & F of chromium plated 15 mm bore Push taps cast copper alloy high pressure screwed for iron/CPVC pipe for urinal complete all as specified and directed. |
| 78 | S&F PVC Connections 15mm size with PTMT nuts of length 600 mm complete all as specified and as directed |
| 79 | S&F inPVC (SWR) floor trap 75 mm, plain with CP grating including joining with solvent cement complete |
| 80 | S & F Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms) 32mm bore |
| 81 | S&F in 20 mm bore, chromium plated bib taps cast copper alloy with crutch or butterfly handle screwed down for iron/PVC pipe complete all as specified & directed. |
| 82 | S&F fancy type pillar taps, long neck, 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed as in repair complete all as specified and as directed |
| 83 | S&F of Brass Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union alongwith arm 225mm and flange complete all as specified and as directed |
| 84 | S&F grating round 125 mm size of PTMT (min weight 40 grms) complete all as specified and directed. |
| 85 | S & F Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long. |
| 86 | Demolition of stone /boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as dirtected |
| 87 | M & L for Pre - cast cement concrete masonry with Grade C-5.0, (20mm graded stone aggregate) with solid blocks wall built in cement mortar 1:6 complete all as specified and as directed |
| 88 | Taking down cement plastering at any description on brick or stone wall etcincluding rakingout joints hacking for key scrubbing down with water etc and removal of debries and depositing where directed complete all as specified and directed by Engr-in-Charge |
| 89 | M&L for rendering 5 mm thick in CM 1:3 in ceiling finished even and smooth (without using extra cement)complete all as specified and directed |
| 90 | M&L for Rendering 15 mm thick cement plaster on concrete solid block walls in two coatsfirst coat of 10 mm in CM 1:4 & 2nd coat of 5mm in CM 1:4 mixed with integral water proofing compound finished to even & smooth w/o using extra cement complete all as specified and as directed.Note :- Integral water proofing liquid will be measured and paid seperately. |
| 91 | Supply only water proofing compound |
| 92 | M&L for rendering 10 mm thick in CM 1:6 on concrete solid blockwall internalsurfacefinished even and smooth without using extra cement complete all as specified and as directed. |
| 93 | M&L for Preparing new plastered ceiling surfaces and applying twocoat ofoil bound distemper alkali resistance on plastered surfaces, preparatory to distempering, after applying 2mm thick wall care putty on ceiling. |
| 94 | M&L for Preparing new plastered wall surfaces and applying twocoat ofoil bound distemper over alakli resistance, on plastered surfaces, preparatory to distempering, after applying 2mm thick wall care putty on wall |
| 95 | M&L for complete removal of existing treatment and Preparing old plastered ceiling surfaces and applying two coat ofoil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 2mm thick wall care putty on ceiling. complete all as specified and directed. |
| 96 | M&L for complete removal of existing treatment and Preparing old plastered wall surfaces and applying two coat ofoil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 2mm thick wall care putty on wall. |
| 97 | M & L for preparation of new plastered surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm all as specified and as directed. |
| 98 | M & L for preparation by complete removal of existing treatment of painted walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm all as specified and as directed. |
| 99 | M&Lfor providing and fixing stainless steel (Grade 316) railing made of hollow tubes , channels , plates, chain etc incl welding, grinding, buffing , polishing, and making curvature(wherever required) and fitting the same with necessary SS nuts and bolts complete , incl fixing the railing with necessary accessories and SS - fasteners, SS bolts ,etc of required size on the top of floor or the side of waste slab with suitable arrangement incl dismantling of existingMS railing grilletc. |
| 100 | S&F 12 mm thick toughened glass as in SS railing windows, partitions automatic doors and similar works incl cutting to shape drilling holes required all as specified and as directed by engineer in charge |
| 101 | Dismantling of existing steel rolling shutters including top covers for repairs & refixing in the same opening after repairs including greasing the spring, guide channel shafts, bearing, bolts, washers, including repairing defective laths spring bearing , hood cover, guide channel suspension shafts etcfor rolling shutter of clear area upto 12 Sqm eachcomplete as directed by Engr-in-ChargeNote:- Necessary sporres will be measured & paid seperately. |
| 102 | S & F Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: gear operated type with bevel gear box and crank handle, thickness of lath 1.25mm complete all as specified and directed. |
| 103 | S& F in repair Ball brass valve, high pressure, with polythene floa thorizontal plunger type, IS-1703-2000 marked screwed to iron pipe or brass ferrule of size 25 mm bore complete all as specified and as directed. |
| 104 | Ball bearing for rolling shutters complete all as specified and directed by Engr-in-Charge. |
| 105 | M &L for Preparation of New steel surfaces and applying two coats of epoxy anti corrossive paint over a coat of zinc primer |
| 106 | M & L for Preparation of old steel surfaces and applying two coats of epoxy anti corrossive paint over a coat of zinc primer |
| 107 | Demolition of cement concrete ( reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed |
| 108 | Removing excavated/ demolished material exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and directed. |
| 109 | Taking down carefully any type of copper/aluminium point wiring (light,fan, socket or power) complete including conduits/casing caping with fittings such as switches,ceiling roses, pendents,regulators,bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed |
| 110 | M & L Point wiring with 1.5Sqmm (nominal area) FRLS PVC insulated unsheathed multistranded copper conductor cable in and including PVC concealed conduit 20 mm dia medium grade ISI marked including fittings and accessories with continues PVC insulatedcopper cable with copper conductor of same size as in phase/neutral/earth cable connecting to common earth dolly including metal flush box and white cover plate with frame complete all as specified and as directed for the followinga)for light , fan point controlled by one way switch |
| 111 | b)for 5 Amp Socket point on same board |
| 112 | c)for 5 Amp socket point on independentboard |
| 113 | M&L for pointwiring with FRLS cable size 2.5 Sq mm nominal area PVC insulated and unsheathed cable single core multistranded, copper conductor drawn in and including in PVC concealed conduit for one 3 pin, 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm all as specified and directed by Engr-in-Charge.(Note: 2 point wiring included for geyser) |
| 114 | S & FModular switch 1 way 6A, 1 module all as directed. |
| 115 | S & FModular switch 1 way 16A, 1 module all as directed. |
| 116 | S & FModular Socket,6A - 2/3 pin combined 2 module, all as directed. |
| 117 | S & F Modular Socket6A/16A - 2/3 pin combined 2 module, all as directed. |
| 118 | S/F ceiling rose 3 terminal 230 volts, PVC polycarbonate, isolated body completed all as specified and directed. |
| 119 | Taking down unserviceable any type of Main Switch, DB\"s including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc all as specified and as directed. |
| 120 | S&F MCB DB TPN double door 04 way 415 volts all as specified and directed. |
| 121 | Supply and fix SPN 8 way DB with 200 amps rated bus bar Double door sutaible for 230 V , 50 HZ |
| 122 | M&L for sheet metal enclosure vertical TPN distribution board , 415 V , 8 way double door with IP-43 protection , suitable for mounting of MCCB of capacity upto 200 A with 400 A copper bus bar , complete all connections with proper thimbling and neutral link fixed flush in wall incl chases wall for fixing DB and making good distrubed wall to match with the existing surface.(Note : MCCB, MCB will be measured and paid separately) |
| 123 | S & F MCCB 4 Pole 125 Amps 415 Volts 25 KA including incloser complete all as specified and directed by Engr-in-charge. |
| 124 | S&F in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified. |
| 125 | S & F MCBTPN 63 Amps 415 volts all as specified and directed by Engr-in-charge. |
| 126 | S & F MCBTP 63 Amps 415 volts all as specified and directed by Engr-in-charge. |
| 127 | S & F MCB SP 6 to 32 Amps 240 Volts all as specified and directed by Engr-in-charge.. |
| 128 | S & F MCB SPN 6 to 32 Amps 240 Volts all as specified and directed by Engr-in-charge. |
| 129 | Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed. |
| 130 | M & L for sub main wiring in replacement with 4 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith two run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 10 sqmm as earth continuity conductor drawn through PVC concealed conduit as reqds size confiming to IS: 9537(Part-3), including accessories fixed on wall/ceiling all as directed including making good of disturbed surfaces area. (Note : Four runs of cable, two run of earth continuity conductor and one run of PVC concealed conduit shall be measured as on unit) |
| 131 | M & L for sub main wiring in replacement with 4 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6 sqmm alongwith two run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 6 sqmm as earth continuity conductor drawn through PVC concealed conduit as reqds size confiming to IS: 9537(Part-3), including accessories fixed on wall/ceiling all as directed including making good of disturbed surfaces area. (Note : Four runs of cable, two run of earth continuity conductor and one run of PVC concealed conduit shall be measured as on unit) |
| 132 | M & L for sub main wiring in replacement with 4 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4 sqmm alongwith two run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 4 sqmm as earth continuity conductor drawn through PVC concealed conduit as reqds size confiming to IS: 9537(Part-3), including accessories fixed on wall/ceiling all as directed including making good of disturbed surfaces area. (Note : Four runs of cable, two run of earth continuity conductor and one run of PVC concealed conduit shall be measured as on unit) |
| 133 | M & L for sub main wiring in replacement with 4 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 sqmm alongwith two run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 2.5 sqmm as earth continuity conductor drawn through PVC concealed conduit as reqds size confiming to IS: 9537(Part-3), including accessories fixed on wall/ceiling all as directed including making good of disturbed surfaces area. (Note : Four runs of cable, two run of earth continuity conductor and one run of PVC concealed conduit shall be measured as on unit) |
| 134 | S & FEnergy efficient surface Mounted LED Luminire 20 watts 4\" long, with acrylic cover aluminium exeruded body completeall as specified and directed by Engr-in-Charge. |
| 135 | S & F in repairs Energy efficient surface Mounted LED Luminire 10 watts 2\" long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.5 mtr all as directed. |
| 136 | S&F in repairs LED light fitting 1x18 watts Surface/recess mounted LED downlighter circular or square shape in powder coated white finish with integrated electronic driver complete all as directed. |
| 137 | S&F in repairs LED light profile strip COB LED with contiuous finishig with integrated electronic driver complete all as directed. |
| 138 | S&F in repairs stepped type electronic fan regulator modular type as per exisitng model on the existing board all as directed. |
| 139 | Material and labour for rewinding of ceiling fan motorof size 1200 mm sweep to 1400 mm sweep of any make/model/type with new supper enamelled copper winding wire ofsimilar gauge and number of turns as existing,including cleaningthe motor properlyand applyingvarnishing heating and assembling of fan motor and rotor fixing back after testing including removing burnt out copper winding wire from ceiling fan motorcomplete all as specified and directed. |
| 140 | Material and labour for rewinding of exhaust fanmotorof size 300 mm to 450 mm sweep to 1400 mm sweep of any make/model/type with new supper enamelled copper winding wire ofsimilar gauge and number of turns as existing,including cleaningthe motor properlyand applyingvarnishing heating and assembling of fan motor and rotor fixing back after testing including removing burnt out copper winding wire from ceiling fan motorcomplete all as specified and directed. |
| 141 | Material and labour for painting to ceiling fan of size 1200 mm sweep to 1400 mm sweep complete body, blades & down rod etc of any sweep/make/model with two coat of synthetic enamel paintby using electric spray machine similar to match with existing colour after preparation surfaces complete all as specified and directed directed.(Note :- Painting work to be carried out after dismantling of ceiling fan) |
| 142 | Material and labour for painting to exhaust fan of size 300 mm to 450 mm sweep to 1400 mm sweep complete body, blades & down rod etc of any sweep/make/model with two coat of synthetic enamel paintby using electric spray machine similar to match with existing colour after preparation surfaces complete all as specified and directed directed.(Note :- Painting work to be carried out after dismantling of ceiling fan) |
| 143 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth |
| 144 | Supply and fix rigid non-metallic PVC conduit of 20 mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. |
| 145 | Supplyand fix copper conductor cable, PVC insulated, sheathed,flexible, multistranded,ISI marked, 1100 volts grade, 3 core ;2.5 sqmm and including connection to geyser and plug outlet andinlcuding removing old unserviceable item complete all as specified and directed. |
| 146 | Dismantling carefully the existing split type AC (indoor & outdoor unit) 1.5/2.0 TR capacity from its position, keep in safe custody and refixing with new bracket and in serviceable condition after renovation of bldg, incl gas filling complete all as directed. (Note :- After taking down will be in contractor costudy to keep in safe condition) |
| 147 | S & F in repairs copper pipe for discharge 5/8\"\" & 3/8\" dia complete for split Acs all as directed. |
| 148 | S & F in repairs Energy efficient LED security Light Luminaire 90 Watts including making electrical connection with PVC flexible wire 1 sqmm3 core from ceiling rose to the connector of filling , conncetion wires not to be less that 2.5 meter in length duly run through GI bracket including taking down old UNSV security light complete all as specified and as directed. |
| 149 | S & F in repairsfor Security light bracket made out of GI tubing 32/40 mm dia, light grade bend to shape suitable for below mentioned security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc. |
| 150 | Supply and fixLED Flood light fittings 180 Watts, anti glare type incl fixing arrangement and connections with 3 run of 2.5 Sq mm aluminium unsheathed wire multistranded complete including taking down of existing UNSV flood light fitting all as specified and directed by Engr-in-charge. |
| 151 | Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dense soil getting out and levelling of bottom surface to required level for laying UG cable/errection of poles complete all as specified and directed by Engr-in-charge. |
| 152 | Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge. |
| 153 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed by Engr-in-charge. |
| 154 | Removing excavated material of soils from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and directed by Engr-in-charge. |
| 155 | Supply and lay Double walled corrugated pipe (DWC ) confirming to IS 14930 heavy duty 63/50 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed |
| 156 | Supply and Laying under ground LT CableXLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 120 Sq mm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098( Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description complete all as specified and directed by Engr-in-charge. |
| 157 | M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamberin cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engr-in-charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy