| 1 | M & L for excavating in trenches for soft/disintegrated rock, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified. |
| 2 | M & L for rough excavation not exceeding 1.5 m deep and getting out in soft disintegrated rock complete all as specified. |
| 3 | Removing excavated material of rockexc. 250 m but n exc. 500 m and depositing where directed |
| 4 | M&L for cement concrete (1:4:8) type D2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete all as specified and directed. |
| 5 | M&L for Squared rubble stone walling , well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed |
| 6 | M& L for 15 mm thick rendering on masonary in CM 1:4 on walls finished even and smooth without using extra cement and all as specified. |
| 7 | M & L forprecast cement concrete 1:2:4, type B0 using 12.5mm graded stone aggregate as in jallies 35 mm thick(measured solid ), incl all mouldings but excluding frame set in cement mortar 1:4. |
| 8 | M & L for preparing old surfaces plastered or unplastered surface of wall by complete removal of existing treatment by steel wire brushing /metal sheet including washing rubbing down and stopping of distempered and painted surface and applying two coat of exterior emulsion paint in different tint/shade (Comouflage pattern) as directed and approved by userover one coat of alkali resistant primer as per manufacturer’s instructions all as specified and directed. |
| 9 | M & L for 20 mm granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. |
| 10 | Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 11 | M & L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade made in rubber mould/ruberised type with gray cement and pigment. |
| 12 | Forming embankments of soil including raising (or lowering) earth, spreading in layers n exc. 30cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5m high from base complete all as specified and directed. Note:- The quotedrateof this items deemed to be included the soil bring out from outside defence land |
| 13 | M & L Non-skid parking tiles shade as approved by GE of 300x300x7-8 mm thick, coloured in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over 15 mm thick screed bed of CM 1:6 all as directed by Engineer in Charge. complete all as specified and directed by Engineer -in- Charge |
| 14 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete. |
| 15 | M & L providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 16 | Formwork to flat Rough finished surfaces of concrete sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to better complete all as specified and directed. |
| 17 | Formwork square, rectangular or polygonal to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed |
| 18 | Formwork to flat Rough finished surfaces of concrete sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed |
| 19 | S&F for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, Beams, footing, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 20 | S&F for TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, spaces and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 21 | M & L RCC nominal mix 1:1.5:3, Type B1(20 mm graded aggregate)for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified. |
| 22 | M&L RCC nominal mix 1:1.5:3, B1 (20 mm graded aggregate) for Columns, pillars, piers, posts and struts complete all as specified. |
| 23 | M&L RCC nominal mix 1:1.5:3, B1(20 mm graded aggregate) for Beams, roof beam, cantilevers, bressummers, lintels over 1.5m span complete all as specified. |
| 24 | Surface excavation n. exc 30cm deep and averaging 65cm deep and getting out in soft and loose soil. |
| 25 | Excavating in trenches n exc 1.50 m inwidth and n exc 1.50 min depth for foundation, manholes etc as well as n exc 10 sqm on plan areaand getting out in soft/loose soil all as specified and directed. |
| 26 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. |
| 27 | Removal of excavated soil in soft & loose soil to a distanceexc 250 and n. exc. 500m m and depositing where as directed at a level of 1.5 m above the starting point complete all as specified and directed. |
| 28 | 40 mm thick Damp proof course In cement concrete 1:2:4, type B-0 to horizontal or vertical surfaces including necessary formwork |
| 29 | M & L for RCC 1:1.5:3, type B-1 (volumatric mix)using 20mm graded crushed stone aggregate asin foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete. |
| 30 | M&L for PCC block masonry with solid blocks exc 10 cm in width 1:3:6 Type C1 20 mm graded aggregate and setting in mortar complete. |
| 31 | M & L 15 mm thick rendering on fair faces of brick walls in CM 1:4, finished fair & smooth w/o using extra cement. |
| 32 | M & L 15 mm thick rendering on fair faces of brick walls in CM 1:6, finished fair & smooth w/o using extra cement. |
| 33 | M & L PCC 1:4:8 type D-2 using 40mm graded aggregate as in 75mm thick sub base . |
| 34 | M&L for 75 mm thick PCC (1:2:4),type B-2, using 40 mm graded stone aggregate as in floor, surfaces finished even and smooth with using extra cement complete all as spfd & directed. |
| 35 | M & L for preparation of new plastered surfaces of walls and applying twocoat of White wash complete as spd & directed |
| 36 | M & L for preparation of new plastered surfaces of walls applying two coat of cement base paint of approved shade complete as spd & directed |
| 37 | M&L for preparation of new steel & Iron surface of width or grith exceeding 10cm & applying two coats of synthetic enamel paint of 1st quality complete all as spd & directed. |
| 38 | S&FRooftrusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) (Fe-410 Grade E-250) including distance pieces, cleats etc |
| 39 | S&F Rolled sections as in main andcross beams, hip and jack rafters; purlins where connected to common rafters and running railsand guides for sliding doors; fixed with angle cleats or other connecting plates (Fe-410 Grade E-250)complete all as specified and directed by EIC. |
| 40 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment |
| 41 | Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws as specified |
| 42 | Pre-painted galvalumealuminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws as specified |
| 43 | M&L for framed work as in door or gates of angle or other section with gusset plate rails braces etc complete drilled for fixing of steel sheeting or other covering. Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings 9 exclusive of steel sheeting or other covering running rails and guides ) and hanging also fastening and fixing complete grade Fe-290 (Gde E-165) as directed by Engineer-in-Charge. |
| 44 | M&L for MS plain black sheet 1.00 mm in wall cladding steel gate and similar work cut to size holes punched including round headed screws clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams including bending or turning up mitred angles etc as required complete all as required as directed by Engineer-in-Charge. |
| 45 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing from site and rubbish off the premises as directed by Engineer-in-Charge |
| 46 | M&L for joint freenon-skid ceramic tiles, coloured, 7 to 8 mm thick in floors etc. area of each tile exc. 0.06 sqm but n. exc. 0.11 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 as directed by Engineer-in-Charge |
| 47 | M&L for glazed ceramic tiles, coloured, 450x300x7mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointedin neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 on stone or brick masonry surfaces as directed by Engineer-in-Charge. |
| 48 | M&L for lightcoloured vitrified ceramic tiles 10 mm thick area of each tiles not less than 0.36 sqm in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in CM 1;6 as directed by Engineer-in-Charge |
| 49 | All as per item no.4above but on vertical surfaces such as dados skirting and risers to step set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in CM 1:4 on stone masonry surfaces as directed by Engineer-in-Charge |
| 50 | M&L for taking down cement or cement lime plaster any description incl racking out joints, hacking for key , scrubbing down with water etc including removal of debrish from the MOD land complete all as specified and directed. |
| 51 | M& L for 10 mm thick rendering on ceiling surfaces in CM 1:3 on finished even and smooth without using extra cement and all as specified. |
| 52 | M&L for preparation of new plastered orun-plastered surfaces of walls and applying two coats of oilemulsion distemperwhite or tinted including removing existing nails, if any, any Nos and filling the disturbed surface/holes making smooth surface as d |
| 53 | M&L for preparation of new surface of ceiling and applying two coat of applying two coats of oil emulsion distemper white or tinted over a coat of primer complete all as specified and directed |
| 54 | Demolition of stone masonry built in cement mortar of any description and in any position not otherwise specifically provided for all as specified. |
| 55 | M&L for Walling of squared rubble, regular coursed, well bonded, bedded and solidly hearted, built in cement mortar1:6 allas specified and directed |
| 56 | M&L for PCC block masonry type B1 1:2:4(20mm graded aggregate) set in CM 1:4 with solid blocks, exc 10 cm in width and setting in mortar complete all as specified and directed. |
| 57 | Taking down chowkhats or frame of any description n. exc 1.5 Sqm each with shutters without taking off shutters from the frame |
| 58 | S&F powder coated aluminum frame/guiding rail for sliding or side hung window/ventilators and for sliding shutters with one or more rebates incl jointing cleats for fixing etc complete all as specified. |
| 59 | S&F rubber gasket for fixing of glass into window/ventilator shutters complete all as specified and directed. |
| 60 | S&F powder coated aluminum shutter glazed/gauzed window and ventilators shutters powder coating side hung type without sash bar aluminum section weighting 0.55 kg per mtr. Including necessary joining cleats glazing clips rubber packing anodised aluminum bading screws including fittings such as peg stays 150mm long hinges 100mm long suitable handle complete all as specified. |
| 61 | S&F powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified |
| 62 | S&F 5.5mm thick sheet glass ordinary quality in square exc 0.50 sqm eachaluminium window shutters/door shutters complete ll as specified. |
| 63 | S&F powder coated aluminium ornamental grills for window frame complete all as specified directed. |
| 64 | S&F in repairs, aluminium (extruded section) body door closer hydraulically regulated, designation No 3, universal type, suitablefor door shutters 851 mm to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 65 | S&Fmild steel mortice lock verticle type 100 mm size, 4 levers complete all as specified and directed. |
| 66 | S&F Aluminium alloy, anodised sliding door bolt with hasp and staple (bolt type) and fixing clip of sheet, cast or extruded section, bolt not less than 16mm dia, 300mm long (ISI Marked)complete all as specified directed. |
| 67 | S&F aluminium handles extruded fabricated type anodized of size 150mm complete all as specified directed. |
| 68 | S&F 300 mm size aluminium anodized barrel tower bolt/extruded section & fixed complete all as specified directed. |
| 69 | S&F floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring of 140mm length complete all as specified directed. |
| 70 | Dismentaling boarding, any description, fixed in any position complete all as specified and directed. |
| 71 | M&L for GI Powder coated micro perforated micro look false ceiling with fleece lay-in-type 0.50mm thick,suitable for grid/frame module of 600x600mm size complete with GI powder coated grid consisting of silhonthe main T runner 15mm suspended at 1200mm center to center and cross T runner of 15mm size suspended at 600mm center to center including steel fastner wall angle and T wall interlocking arrangement as required for framing grid suitable for module size 600x600mm ceiling etc including fixing of metallicceiling boards complete all as per specification and directed.(make: Armstrong/hunterduglas) |
| 72 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion holdfasteners 12.5mm dia. 40mm long complete all as specified |
| 73 | Demolition of Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets |
| 74 | Dismantling of battens for tiles, shingles etc, of any size including tilting fillets spacing exc 15 cm |
| 75 | M& L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. |
| 76 | M&L for 12 mm thick Fibre insulation boards flame retardant type, treated on one face only fixed or laid/ inserted to GI framework with screws fixed in jointless finish with jointing compound and jointing tape as per manufacturer instructions |
| 77 | M&L for 12 mm thick Fibre insulation boards flame retardant type, treated on one face only fixed or laid/ inserted to GI framework with screws fixed in ceiling flat or sloping fixed in jointless finish with jointing compound and jointing tape as per manufacturer instructions |
| 78 | M & L for two coat of fire resisting paint on surfaces of anydescription wood, steel, iron, concrete, brick, stone, etc., exceeding 10cm in width or girth |
| 79 | M&L for 100 mm thick cement concrete (1:4:8) type D2 using 40 mm graded stone aggregates as in sub base, filling and mass concrete all as specified and directed. |
| 80 | M&L Dholpur stone cladding gang saw cut with machine cut edges, uniform colour of each stone size exceeding 0.25 sqm area and not exceeding 0.5 sqm fixed with and including one number SS clamps (grad-202) of flat 30mm x 2mm, 150 mm long made to shape in each slab, making V groove at top and bottom of stone and drilling hole for hold fastener, polishing, rubbing & including silicon treatment all as specified and directed. |
| 81 | Taking down carefully copper/aluminum point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc,. |
| 82 | M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor, single core, PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in concealed conduit heavy duty with accessories (like bend,junction boxes etc), GI terminal boxes not less than 1.0mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover or including modular plates of required size for mounting switch and sockets etc. complete all as specified and directed for following : - Note : Quoted rates deems to be included cost of modular plate for mounting switches, sockets & regulators as required at site. |
| 83 | One light point controlled by one switch one way. |
| 84 | One fan point controlled by one switch one way. |
| 85 | One 3 pin socket outlet 5 Amp on same board with other switches. |
| 86 | One 3 pin socket outlet 5 Amp on Independent board with other switches. |
| 87 | All same as per item ser No 80.00 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, FRLSH, single core, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independant board. |
| 88 | S&F switch modular one way 6 Amps 230 volt, 1 module. |
| 89 | S&F switch modularone way 16 Amps 230 volt 1 module. |
| 90 | S&F Socket modular 6 Amp 2/3 pin combined two module. |
| 91 | S&F Socket modular 6&16 Amp 2/3 pin combined two module. |
| 92 | S&F Modular staped type fan regulator, 2 module. |
| 93 | S&F Ceiling rose surface bakelite 65x50mm three terminal. |
| 94 | Supply and replace sheet metal enclosures distribution board for 240 volts, 4 way horizontal type, singledoor, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and blank plates and fixed flush in wall surface, and tested on completion complete including taking out old unserviceable sheet metal enclosures complete all as specified and directed. |
| 95 | M&L for MCB SPN/DP 32 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. |
| 96 | Supply and fixing MCB single pole 6-32 Amps, 240 volts, providing in DB complete including connection & testing all as specified. |