| 1 | Dismantling unserviceable ACSR conductor of any size and type from LT pole and removing the quantity from site complete all as specified and as directed. |
| 2 | Dismantling and taking down existing unserviceable / GI earth continuity conductor (of any size or type) from over head electric line and removing from site complete all as specified and as directed. |
| 3 | Dismantling insulators of any size /type and removing from site complete all as specified and as directed. |
| 4 | Dismantling and taking down mild steel cross arms, bracings, supports, channels, angles, clamps etc from pole structure and removing from site complete all as specified and as directed. |
| 5 | Taking out unserviceable stay assemblyincluding necessary excavation and demolition of PCC foundation and removing the same from site complete all as specified and as directed. |
| 6 | Taking down existing unserviceable stay wire of any size from LT pole complete all as specified and as directed. |
| 7 | Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in soft/loose soil complete all as specified and as directed. |
| 8 | Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and as directed. |
| 9 | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 10 | Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying and punning to 18 cm complete all as specified and as directed. (Note : Punned thickness shall be measured). |
| 11 | Material and labour for well burnt bricks,Sub class \"B\" bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed. |
| 12 | M&L 100 mm bore steel for tubing light grade ISI marked for protection of cable including necessary joint including taking down old unserviceable one complete all as specified and as directed. |
| 13 | M&L 50 mm bore steel for tubing light grade ISI marked for protection of cable including necessary joint including taking down old unserviceable one complete all as specified and as directed. |
| 14 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade cross sectional area 400 sq. mm 3½ Core including Brass Glands complete all as directed by Engr-in-Charge. |
| 15 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade cross sectional area 300 sq. mm 3½ Core including Brass Glands complete all as directed by Engr-in-Charge. |
| 16 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade cross sectional area 95 sq. mm 3½ Core including Brass Glands complete all as directed by Engr-in-Charge. |
| 17 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade cross sectional area 35 sq. mm 4 Core including Brass Glands complete all as directed by Engr-in-Charge. |
| 18 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade cross sectional area 16 sq. mm 4 Core including Brass Glands complete all as directed by Engr-in-Charge. |
| 19 | M & L forBoring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface / footpath with the help of GI Tubing not exc. 100mm bore (dia) for passing of UG Cable, complete all as specified and directedNOTE: GI Pipe laid will be measured and paid separately under appropriate Item. |
| 20 | Dismantling existing cement poles/ steel struts, any size carefully for reuse including necessary excavation demolition of concrete transportation cost etc. and removing the old unserviceable rubbish etc |
| 21 | M & L for Steeltubular swagedpolescompletewithcastiron/MSbaseplate , finialtaperplug , bolts , nuts & screwsasspecifiedtype 410 SP-22 , 8.5 meter long including making hole of 2 inch dia at 2.5 meter from bottom and 1 inch at 8 meter from bottomcomplete all as specified & directed.Note: PCC anti climbing device, cross arms insulator, ACSR conductor and earth work measure and paid separately) |
| 22 | M&L PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for stay set /Pole/ Panels etc including fair finish even and fir to exposed surfaces without using extra cement complete all as specified and as directed. |
| 23 | M & LPCC (1:2:4) type B-1 (with using 20 mm graded stone aggregate) as copingof pole/panel including necessary form work as requiredcomplete as directed |
| 24 | Supply, commissioning and testing cubical housing cabinet type, weather proof, outdoor type CPRI approved, factory made LT Panel boad, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame,Overall dimension suitable to operate submersible pump, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement complete all as specified and as directed and Panel board shall comprise of the following :-(a)Copper Busbar rating- 1000 Amps- 04 Nos(b)Indication lamp for RYB - 01 Set(c) MCCB-500 Amp, 4pole, 36K adjustable thermal and magnetic settig, 415 V, 50 Hz AC-01 No(incoming) (d) MCCB-320 Amp, 4 pole, 25KA fixed thermal and magnetic settig, 415 V, 50 Hz AC - 02 No (d) MCCB-160 Amp, 4 pole, 25KA fixed thermal and magnetic settig, 415 V, 50 Hz AC - 02 No (e) MCCB-63 Amp, 4 pole, 10KA fixed thermal and magnetic settig, 415 V, 50 Hz AC - 02 No (j)S&F digital ampere meter 31/2 display incl CT having CTR 500/5-01 Nos (h) S & F digital voltmeter 0-500 V= 01 Nos |
| 25 | Supply, commissioning and testing cubical housing cabinet type, weather proof, outdoor type CPRI approved, factory made LT Panel boad, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame,Overall dimension suitable to operate submersible pump, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. Panel board shall comprise of :-(a)Copper Busbar rating- 600 Amps- 04 Nos(b)Indication lamp for RYB - 01 Set(c)MCCB-320 Amp, 4pole, 36 K adjustable thermal and magnetic settig, 415 V, 50 Hz AC- 01 No(incoming) (d)MCCB-125 Amp, 4 pole, 16KA adjustable thermal and magnetic settig, 415 V, 50 Hz AC - 01 No (e)MCCB-100 Amp, 4 pole, 16KA adjustable thermal and magnetic settig, 415 V, 50 Hz AC - 01 No (f) MCCB-80 Amp, 4 pole, 16 KA fixed thermal and magnetic settig, 415 V, 50 Hz AC - 01 No (g)MCCB-32 Amp, 4 pole, 10KA adjustable thermal and magnetic settig, 415 V, 50 Hz AC - 05 No(h) S&F digital ampere meter 31/2 display incl CT having CTR 320/5-01 Nos (j) S & F digital voltmeter 0-500 V= 01 Nos |
| 26 | Supply, commissioning and testing cubical housing cabinet type, weather proof, outdoor type CPRI approved, factory made LT Panel boad, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame,Overall dimension suitable to operate submersible pump, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. Panel board shall comprise of :-(a) Copper Busbar rating- 200 Amps- 04 Nos(b) Indication lamp for RYB - 01 Set(c) MCCB-80 Amp, 4pole, 16 K adjustable thermal and magnetic settig, 415 V, 50 Hz AC-01 No(incoming)(d) MCCB-32 Amp, 4 pole, 10 KA fixed thermal and magnetic settig, 415 V, 50 Hz AC - 05 Nos (j)S&F digital ampere meter 31/2 display incl CT having CTR 80/5-01 Nos (h) S & F digital voltmeter 0-500 V= 01 Nos |
| 27 | Supply, commissioning and testing cubical housing cabinet type, weather proof, outdoor type CPRI approved, factory made LT Panel boad, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame,Overall dimension suitable to operate submersible pump, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. Panel board shall comprise of :-(a)Copper Busbar rating- 200 Amps- 04 Nos(b)Indication lamp for RYB - 01 Set(c)MCCB-100 Amp, 4pole, 16KA adjustable thermal and magnetic settig, 415 V, 50 Hz AC-01 No(incoming) (d) MCCB-32 Amp, 4 pole, 10KA fixed thermal and magnetic settig, 415 V, 50 Hz AC - 04 No (j)S&F digital ampere meter 31/2 display incl CT having CTR 100/5-01 Nos (h) S & F digital voltmeter 0-500 V= 01 Nos |
| 28 | Supply, commissioning and testing cubical housing cabinet type, weather proof, outdoor type CPRI approved, factory made LT Panel boad, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame,Overall dimension suitable to operate submersible pump, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. Panel board shall comprise of :-(a)Copper Busbar rating- 250 Amps- 04 Nos(b)Indication lamp for RYB - 01 Set(c)MCCB-125 Amp, 4pole, 25KA adjustable thermal and magnetic settig, 415 V, 50 Hz AC-01 No(incoming) (d) MCCB-32 Amp, 4 pole, 10KA fixed thermal and magnetic settig, 415 V, 50 Hz AC - 05 No (j)S&F digital ampere meter 31/2 display incl CT having CTR 125/5-01 Nos (h) S & F digital voltmeter 0-500 V= 01 Nos |
| 29 | Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32 mm x 6mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting (Inside cavity to be made in Pit for placing cover slab) made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion all as specified and directed incl demolition to existing one complete. |
| 30 | Supply and fixing of loop in loop out junction box with SP 6-32 amp,IP 65 / IP 66 protection halogen free andweather proof of minimum size (130 x 180 x 77) mm, fixed to Pole with suitable clamp including nuts and bolts and washers incl provision of connector fixed to pole complete all as specified and directed. |
| 31 | Supply and fixing PVC medium grade conduit 20 mm dia for drawing cable between pole junction box and light fitting brakect including fixing clamp made of GI strips and nut and bolts (Minimum 3 clamp in each pole to be provided.) complete all as specified and directed. |
| 32 | Supply and fixing 1100 volts grade PVC insulated weather proof sheathed copper cable 1.5 sqmm size 3 core between pole junction box and light fitting complete all as specified and directed. |
| 33 | NOTES:1.The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.2.The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule \"A\" notes for details. |