| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 4 | Group C |
| 5 | Supplying and fixing of following sizes of medium class PVC coduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as reqd. |
| 6 | 25mm |
| 7 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required. |
| 8 | 3x1.5mm2 |
| 9 | 3x4mm2 |
| 10 | Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as reqd. |
| 11 | 1 or 2 Module (75mmX75mm) |
| 12 | 3 Module (100mmX75mm) |
| 13 | 4 Module (125mmX75mm) |
| 14 | 6 Module (200mmX75mm) |
| 15 | 8 Module (125mmX125mm) |
| 16 | Supplying and fixing following modular switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as reqd. |
| 17 | 5/6 A switch |
| 18 | 15/16 A switch |
| 19 | 3 pin 5/6 A socket outlet |
| 20 | 6 pin 15/16 A socket outlet |
| 21 | Supply and installation of PVC trunking recessed / surface of size 105mmx50mm deep complete with suitable size cover , end caps,base joint, joint for covers,as required, internal external angels, bends, T sections etc complete in all respect. |
| 22 | Supply and erection of following module frame for PVC trunking to install switch socket accessories etc complete in all respect. |
| 23 | 6 module |
| 24 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as reqd. |
| 25 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 and 15/16amps modular socket outlet and 15/16 amps modular switch, connection etc. as reqd. |
| 26 | Supplying and fixing following way, horizontal type three pole and neutral, Sheetsteel, MCB distribution board415 volts on surface / recess complete with tinned copper busbar, neutral busbar, earth bar, din bar interconnections, powder painted including earthing etc. as required. ( But without MCB / RCCB/Isolator.) |
| 27 | 8 way (4 + 24), Double door |
| 28 | Supplying and fixing 5amps. To 32 amp. Rating, 240/415 volts, \"\"C\"curve, MCB suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 29 | Singlepole |
| 30 | Supplying and fixing following rating, four pole, 415 volts, TPN in the existing MCB DB complete with connections, testing and commissioning etc. as reqd. |
| 31 | 63 Amps. |
| 32 | Supply of 4 core copper conductor, XLPE insulated PVC sheathed armoured cable confirming to IS : 7098 (part – I), 1100 v Grade of the following sizes. |
| 33 | 10 mm2 |
| 34 | Laying and fixing of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 35 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 36 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 37 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 38 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 39 | Supplying,installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 3 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. |
| 40 | Supply, installation, testing and commisioning of min. 30W linearLed fixture 1200mm Length withcolor temperature5700K,made of a single piece Pressure die cast aluminum (PDC) housing for rapid thermal healing, Having P.F.>0.95 with THD<10% ,UGR < 17, CRI 80, Surge Protection 2 Kv with IP Protection of IP20 .The LEDswith minium life of 50000Hrs. The Input voltage range shall be 150V to 270V as per the satisfaction of the Engineer Incharge. |
| 41 | LED Panellight 2x2ft., (System lumen efficacy>135 lm/Watt) |
| 42 | Supplying, installation, Testing & Commissioning of Panellight 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirementwith Driver efficiency >85%, Operating voltage AC140 270 Volt,freq50/60hz,Operatingtemprange-15degto40degcentigrade,internalsurge protection of 2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95,IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free,(flicker should be below 5 %), life time (LED,Driver & electrical circuitry),of minimum50000 Burning Hours with , 70% of initial Lumenmaintained tilllife ends ,CCT 3000°K /4000°K /5700°K /6000°K/6500°K(As perANSI Bin), SDCM(Standard Deviation Color Matching) <3,Maximumpower consumption should not more than thespecified rating and Fixture shall be of relevant BIS standard andtrade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ |
| 43 | Screen printing on housing. completeinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy>135lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C). |
| 44 | Powder coated die cast/ Extrudedaluminium Body (Thickness ≥ 1.20 mm) |
| 45 | 36 watt |
| 46 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) |
| 47 | Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Wattoutput . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) |
| 48 | Powder coated die cast /Extruded aluminium Body including trim |
| 49 | 18 watt |
| 50 | Supply of XLPE insulated and PVC sheathed armoured power cable of 1.1 kV grade, Aluminum conductor armoured cable of following size. |
| 51 | 4 core, 16 sqmm |
| 52 | 3.5 core, 50 sqmm |
| 53 | 3.5 core, 70 sqmm |
| 54 | 3.5core, 120 Sq.mm. |
| 55 | 3.5core, 150 Sq.mm. |
| 56 | 3.5core, 240 Sq.mm. |
| 57 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 58 | Upto 35 sq. mm |
| 59 | Above 35 sq. mm and upto 95 sq. mm |
| 60 | Above 95 sq. mm and upto 185 sq. mm |
| 61 | Above 185 sq. mm and upto 400 sq. mm |
| 62 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 63 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 64 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 65 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 66 | 4 X 16 sq. mm (28mm) |
| 67 | 3½ X 50 sq. mm (35mm) |
| 68 | 3½ X 70 sq. mm (38mm) |
| 69 | 3½ X 240 sq. mm (62mm) |
| 70 | 3½ X 150 sq. mm (50mm) |
| 71 | 3½ X 120 sq. mm (45mm) |
| 72 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 73 | 150 A, 16 KA,TPMCCB |
| 74 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. |
| 75 | For 8 way, Double door TPN MCBDB |
| 76 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 77 | 63A |
| 78 | Supply and fixing of IP 20 Batten Led fixture maximum 20 W with Surface Mounted 4 Feetwith Polycarbonate diffuser with aluminium housing having minimum system lumen output 2200 lumens withP.F.>0.95 with THD<10% ,CCT 5700K, CRI 80, Surge Protection 4 kV .The LEDswith minimum life of 75000 burning hours at L70. The Input voltage range shall be 150V to 270Vt. Complete in all respect upto the entire satisfaction of EIC. |
| 79 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). |
| 80 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 81 | 150 watt |
| 82 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 83 | 20 mm |
| 84 | Earthing with copper bonded solidearthing electrode rod dia 14.2 mm made with cold rolled steel with coating ofnickle & molecular bonded copper250 micron, including accessories, and providingready made heavy dutypoly plastic earth pit cover, complete in all respect upto the Entire satisfaction of EIC. |
| 85 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 86 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 87 | Supply Erection, Testing and Commissioning of Cubical Type Meter Panel shall be made from Thermoplastic (Polycarbonate) andASTA CPRI approved in accordance with IEC 60439-1.Meter Panel should beoutdoor type, UV resistance in accordance with IEC 61439/2011 part 1 and part 2, clause 10.2.4: The panel should be shock proof , anti-acid & anti corrosive. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of ASTA CPRI TEST REPORT IN POLYCARBONATE only. DEGREE OF INGRESS PROTECTION IP 54IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane. The manufacturer of panel shall submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. Test Reports submitted for other material of construction like MS, SS will not be applicable. The panel should pass glow wire test 960°C in accordance with 60695-2-11 (flame retardant and self-extinguishing). |
| 88 | Fittted with gaskets, Lifting Hooks, Cable Entry bottom/top,Approx. Size of Meter panel should be size 1880 x 1800 x 760mm,The solid insulatedbus bar shall beof Copper conductor with Color Coded Heat Shrinkable PVC Sleeves LT panel comprising of the following:- |
| 89 | INCOMING:- |
| 90 | 400A 4 Pole 36KA MCCB with Electronic Release having LSIG Protectionandon-off -trip indication . Ics=100%Icu: 1 No. each |
| 91 | Spreader Terminals |
| 92 | Auxiliay + Alarm Contact Block |
| 93 | Auxiliary Contactor 2NO+2NC |
| 94 | R,Y,B Phase Indication lamps LED Type |
| 95 | MCB 6A SP 10KA \"C\" Curve |
| 96 | Outgoing Feeder Bus Section : |
| 97 | Provision for 3phase energy meter--16Nos |
| 98 | 63A FP 10KA MCB-- 16 Nos. |
| 99 | Bus Bar: |
| 100 | 400 Amp TPN, Copper busbar and hoirizontal and vertical busbar as per load with color coded heat shrinkablesleeves and SMC support inulators. |
| 101 | Metering: Digital multifunction meter for Input supply CL 1.0 with RS485, CT CL 1.0 400/5, 5VA, CTTB |
| 102 | Connections by copper wires along with all the required accessories for fixing & mounting. |
| 103 | The drawing of the panel to be got approved before fabrication by Engineer Incharge. |
| 104 | Main panel for AKU Block |
| 105 | Supplying installation, testing & commissioning of modular cubicle type, LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply IP 42 system, compartmentalized made from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for glandplates, complete with 9 tank process for powder coating in approved shade, Panel shall be minimum Form 3B. Panel shall be Tested for IK 10, Internal Arc protection and Fault Level of Minimum 36KA for 1 sec .All switchgear used shall have Fault levelIcs =Icw=100 %Ics All Incomers Including main Incomers and Buscouplers have mechanically and Electrically interlocked Between each other. |
| 106 | The drawing must be approved by the engineer in charge prior to the commencement of panel fabrication. Bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 2.5 sq. mm. PVC insulated copper conductor cable, providing with following switch gears :- |
| 107 | INCOMERSECTION- I |
| 108 | MCCB TP 630A.50KA. with Microprocessor Based(built in LSIG protection)-1Nos |
| 109 | Spreader Links & Phase Barriers (Set) |
| 110 | Rotary Operating Handle |
| 111 | INCOMERSECTION- II |
| 112 | MCCB TP 630 A.50KA. with Microprocessor Based(built in LSIG protection)-1 Nos |
| 113 | Spreader Links & Phase Barriers (Set) |
| 114 | Rotary Operating Handle |
| 115 | BUS COUPLER |
| 116 | MCCB TP 630A.50KA with Microprocessor Based(built in LSIG protection)-1 Nos |
| 117 | Spreader Links & Phase Barriers (Set) |
| 118 | Rotary Operating Handle |
| 119 | 6A 1P 10kA C-Curve MCB |
| 120 | Red Direct Integral LED indicating lamp,Voltage: 230V AC |
| 121 | Rotary Operating Handle |
| 122 | Aux + Trip Contact for MCCB |
| 123 | Phase LED type Indicating lampR, Y,B,230V AC |
| 124 | Multifunction Energy Meter with RS485, Parameters: Volts, Amps, PF, THD, F, W, Wh, VA, VAh, Var, Varh, Runhrs, On hrs, Phase angle, Interrupts, THD, Events (High-Low), Neutral Current |
| 125 | 6A 1P 10kA C-Curve MCB |
| 126 | Current Transformer 400/5A Cl-1 , Resin Cast for Metering |
| 127 | CT shorting link |
| 128 | BUS BARS |
| 129 | TPN Aluminum Bus bars, 1200 Amps, with color coded heat shrinkable pvc sleeves and busbar support100% neutral of Aluminumconductor-2 No |
| 130 | OUTGOING SECTION-I |
| 131 | 3P 25kAMCCB withThermal Magnetic Release (O/C, S/C) Protections |
| 132 | Rotary Operating Handle |
| 133 | Spreader Links & Phase Barriers (Set) |
| 134 | Aux + Trip Contact for MCCB |
| 135 | LED type Indicating lamp , ON (RED) & OFF (GREEN) 230V AC |
| 136 | LED type Indicating lamp , TRIP (AMBER) 230V AC |
| 137 | Control MCB,6A SP,10KA C-Curve |
| 138 | Neutral Link |
| 139 | Rating |
| 140 | i) 250 Amp-3 nos |
| 141 | ii)160Amp-3 nos |
| 142 | iv)spare space-1 nos |
| 143 | OUTGOING SECTION-II |
| 144 | 3P 25kAMCCB withThermal Magnetic Release (O/C, S/C) Protections |
| 145 | Rotary Operating Handle |
| 146 | Spreader Links & Phase Barriers (Set) |
| 147 | Aux + Trip Contact for MCCB |
| 148 | LED type Indicating lamp , ON (RED) & OFF (GREEN) 230V AC |
| 149 | LED type Indicating lamp , TRIP (AMBER) 230V AC |
| 150 | Control MCB,6A SP,10KA C-Curve |
| 151 | Neutral Link |
| 152 | Rating |
| 153 | i)250 Amp-3 nos |
| 154 | ii)160Amp-2 nos |
| 155 | iv)spare space-1 nos |
| 156 | Sub panel for AHU |
| 157 | Supplying installation, testing & commissioning of modular cubicle type,LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply IP 42 system, compartmentalized made from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for glandplates, complete with 9 tank process for powder coating in approved shade, Panel shall be minimum Form 3B. Panel shall be Tested for IK 10, Internal Arc protection and Fault Level of Minimum 36KA for 1 sec .All switchgear used shall have Fault levelIcs =Icw=100 %Ics All Incomers Including main Incomers and Buscouplers have mechanically and Electrically interlocked Between each other. |
| 158 | The drawing must be approved by the engineer in charge prior to the commencement of panel fabrication. Bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 2.5 sq. mm. PVC insulated copper conductor cable, providing with following switch gears :- |
| 159 | INCOMERSECTION- I |
| 160 | MCCB TP 400A.50KA. with Microprocessor Based(built in LSIG protection)-1Nos |
| 161 | Spreader Links & Phase Barriers (Set) |
| 162 | Rotary Operating Handle |
| 163 | Red Direct Integral LED indicating lamp,Voltage: 230V AC |
| 164 | Aux + Trip Contact for MCCB |
| 165 | Phase LED type Indicating lampR, Y,B,230V AC |
| 166 | Multifunction Energy Meter with RS485, Parameters: Volts, Amps, PF, THD, F, W, Wh, VA, VAh, Var, Varh, Runhrs, On hrs, Phase angle, Interrupts, THD, Events (High-Low), Neutral Current |
| 167 | 6A 1P 10kA C-Curve MCB |
| 168 | Current Transformer 400/5A Cl-1 , Resin Cast for Metering |
| 169 | CT shorting link |
| 170 | BUS BARS |
| 171 | TPN Aluminum Bus bars, 1000 Amps, with color coded heat shrinkable pvc sleeves and busbar support100% neutral of Aluminumconductor |
| 172 | OUTGOING SECTION |
| 173 | 160Amp 3P 25kAMCCB withThermal Magnetic Release (O/C, S/C) Protections- 4 No |
| 174 | Rotary Operating Handle |
| 175 | Spreader Links & Phase Barriers (Set) |
| 176 | Aux + Trip Contact for MCCB |
| 177 | LED type Indicating lamp , ON (RED) & OFF (GREEN) 230V AC |
| 178 | LED type Indicating lamp , TRIP (AMBER) 230V AC |
| 179 | Control MCB,6A SP,10KA C-Curve |
| 180 | Neutral Link |
| 181 | Rating |
| 182 | i)160Amp-4 nos |
| 183 | ii) 125Amp-2 nos |
| 184 | Upgradation of existingLT panel at NH-II sub-station |
| 185 | Upgradation of existingLT panel at NH-II sub-station. The Job includes exetnsion of existing panel by fabricating from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for glandplates, complete with 9 tank process for powder coating colur is to matched with exixting LT panel. |
| 186 | Bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars , providing with following switch gears :- |
| 187 | Feeder |
| 188 | MCCB TP 630A.50KA. with Microprocessor Based(built in LSIG protection)-2 No |
| 189 | Spreader Links & Phase Barriers (Set) |
| 190 | Rotary Operating Handle |
| 191 | 6A 1P 10kA C-Curve MCB |
| 192 | Red Direct Integral LED indicating lamp,Voltage: 230V AC |
| 193 | Rotary Operating Handle |
| 194 | Aux + Trip Contact for MCCB |
| 195 | Phase LED type Indicating lampR, Y,B,230V AC |
| 196 | Multifunction Energy Meter with RS485, Parameters: Volts, Amps, PF, THD, F, W, Wh, VA, VAh, Var, Varh, Runhrs, On hrs, Phase angle, Interrupts, THD, Events (High-Low), Neutral Current |
| 197 | 6A 1P 10kA C-Curve MCB |
| 198 | Current Transformer 400/5A Cl-1 , Resin Cast for Metering |
| 199 | CT shorting link |
| 200 | BUS BAR |
| 201 | TPN Aluminum Bus bars, 1600 Amps, with color coded heat shrinkable pvc sleeves and busbar support100% neutral of Aluminumconductor. |
| 202 | Supply of 3 core XLPE insulated and PVC sheathed armoured power cable of 1.1 kV grade, Aluminum conductor armoured cable of following size. (i) 6 sqmm |
| 203 | Supplying and fixing of 20 w LED fixture withminimum 15 minutes Emergency battery backuphaving metal housing and IP 66 protection for longer life and opal finish cover suitable for wet locations, complete in all respect, upto the Entire satisfaction of EIC. |
| 204 | Supply & erection of 3 mtr long decorativepoleof minimum thickness 3mm galvanized mild steel with cast aluminium embellishments duly painted with Polyurethene paint over primer coating complete with the base plate , foundation bolts along with inbuilt junction box, termination of cable with lugs, connectors for the cable termination and with supply & fixing of one number 6 amps single pole MCB, C-curve, 10KA for each luminaries. The streetlight poles shall be erected in the RCC foundation with special foundation bolts \"J\" type minimum M16 X 450mmlong galvanized M.S. Rod duly threaded in the existing RCC foundation of suitable size as per the approved drawing. Sample of pole should be approved from EIC before installation. Job also includes making iron cage like structure built outside the pole with height of 4\" with proper coating of green paint complete in all respect. The size of foundation as below |
| 205 | Providing cement concrete foundation with the following specifications including excavation and finishing the surface to orignal |
| 206 | The foundation base shall be constructed with cement concrete gatka of ratio 1:5:10 of size 600mm X 600mm X 200mm high. |
| 207 | RCC foundation shall be constructed from cement concrete mixture M-20 grade of ratio 1:1.5:3 of size 500mm X 500mm X 1200mm high, (including 100/200mm projection above the ground level) above the foundation base. (including removal of malba from site)complete in all respect as required. |
| 208 | Reinforcement with Tor-steel should be as Under: |
| 209 | Horizontal rings made from 8mm dia = 6Nos |
| 210 | Vertical rods made from 10mm dia 42” long = 6Nos |
| 211 | Supply and installation of LED Decorative Post top 40W, with minimum outer dia 510(W) x 890(H)mmsuitable for 3.0 mtr long pole with aluminium housing, CRI-80, IP66, Ambient temp-0 to 45 DegC, Driver efficiency>90%, with Luminaire lumen ≥ 4000 lumens (100 lm/W), CCT - 3000K, THD<10%, Powerfactor>0.95, Surge protection-3 kV, 50000Hr, complete in all respect. |
| 212 | SITC of polycarbonate thermoplastics 4 Way Vertical TPN distribution board in accordance with IEC 61439-3 which should be shock proof, Protection Class-I, earthed. IP65 in accordance with IEC 60529 (EN 60529), weather proof, Corrosion free, Acid & Chemical Resistant, Impact resistant, Ultra Violet resistance, made of halogen and silicon free recyclable material conform to RoHS directive 2002/95/EC ). The DB shall have high grade internally embedded gasket made of Polyurethane ( PUR ) with provision for cable entry through integrated flanges top and bottom with removable side walls, Impact strength IK 08 (5 joules) in accordance with EN 50298:98,should withstand Glow wire test at 960°C in accordance with IEC 60695-2-11 flame retardant, Self Extinguishing, UL subject 94,V 2.Color: Grey, RAL 7035. The entire system should have hinged door and it can be combination of transparent.All the doors should be lockable type / door fasteners for tool and hand operated. Busbar current carrying Capacity 250A.rated voltage 690 V a.c.rated conditional short-circuit current of the device Icc = 25 kA. With PE and N terminals ,per PE/N 1 x 6-95 mm², 8 x 1,5-16 mm², Cu. |
| 213 | Providing & fixing enclouser of following size to keep the main panel outside made of 0.50 mm thick PPGI sheet all around & on roof to be fixed on M.S. angle iron frame of size 40x40x6mm duly painted & embeded in Cement concrete block under the ground alongwith foundation of required size of panel and locking arrangement as required at site, complete in all respect upto the entire satisfaction of Engineer in charge.Size: 3.0 Mtr wide, 2.0 Mtr deep & 2.5 Mtr high. |
| 214 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 215 | 100 A, 16 KA,TPMCCB |
| 216 | 250 A, 25 KA,TPMCCB |
| 217 | 400 A, 35 KA,TPMCCB |
| 218 | Supply, Installation, Testing and Commissioning of PMSM HVLS IP54 ceiling fan 10 ft, 05 aero blades with high grade aluminium alloy 6061 T6, Air flow 99000 CFM, 100 RPM, Impeller grade DIN 17100 GR ST 52.3 variable speed, having sound level @ 03 mtr. below fan(db) <50, copper winding, intelligent controller drive and all remaining accessories including nut bolts, fastners, suitable for 230/415 V, 50 Hz, single phase AC Supply, earthing, white colour, of approved make and model etc, complete in all respect as required at site to install the ceiling fan i.e. scafolding etc., civil, mechanical work upto the Entire satisfactiof EIC. |
| 219 | Rebate of old dismantled material including removal of the same from the PGI premises complete in all respect as per detail given below:- Light points (153 Nos), Assorted GI Boxes (95 Nos), Assorted DBs (26 Nos), MCBs (628 Nos), lights Fixtures (174 Nos), LT panles (1 No), |