| 1 | C73340415174 Supply of high static pressure Ductable AC unit capacity 8point5 TR having one indoor and one out door unit refer annexure-III | Supply of high static pressure Ductable AC unit capacity 8point5 TR having one indoor and one out door unit refer annexure-III |
| 2 | 100000000000 Supply of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split AC units 8point5 TR refer annexure-III | Supply of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split AC units 8point5 TR refer annexure-III |
| 3 | 100000000001 Providing cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor refer annexure-III | Providing cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the AC indoor refer annexure-III |
| 4 | 100000000002 Providing of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure-III | Providing of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure-III |
| 5 | 100000000003 Supplying of XLPE insulated, PVC sheathed, armoured, copper conductor, 1point1 kV grade LT cable of size 4 core - 6 sqmm refer annexure-III | Supplying of XLPE insulated, PVC sheathed, armoured, copper conductor, 1point1 kV grade LT cable of size 4 core - 6 sqmm refer annexure-III |
| 6 | 100000000004 Supply of XLPE insulated, PVC sheathe, copper conductor, 1point1 kV grade LT cable of size 4 core - 2point5 sqmm refer annexure-III | Supply of XLPE insulated, PVC sheathe, copper conductor, 1point1 kV grade LT cable of size 4 core - 2point5 sqmm refer annexure-III |
| 7 | 100000000005 Supply of 150 mm width X 50 mm depth X 1point6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray refer annexure-III | Supply of 150 mm width X 50 mm depth X 1point6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray refer annexure-III |
| 8 | 100000000006 Installation testing and commissioning of high static pressure Ductable AC unit capacity 8point5 TR refer annexure-IV | Installation testing and commissioning of high static pressure Ductable AC unit capacity 8point5 TR refer annexure-IV |
| 9 | 100000000007 Erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units refer annexure-IV | Erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units refer annexure-IV |
| 10 | 100000000008 Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure-IV | Laying of cPVC SDR11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure-IV |
| 11 | 100000000009 Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure-IV | Laying of cPVC SDR11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure-IV |
| 12 | 100000000010 Laying of XLPE insulated, PVC sheathed, armoured, copper conductor 1point1 kV grade LT cable of size 4 core - 6 sq mm refer annexure-IV | Laying of XLPE insulated, PVC sheathed, armoured, copper conductor 1point1 kV grade LT cable of size 4 core - 6 sq mm refer annexure-IV |
| 13 | 100000000011 Laying of XLPE insulated, PVC sheathe, copper conductor 1point1 kV grade LT cable of size 4 core - 2point5 sqmm refer annexure-IV | Laying of XLPE insulated, PVC sheathe, copper conductor 1point1 kV grade LT cable of size 4 core - 2point5 sqmm refer annexure-IV |
| 14 | 100000000012 Installation of 150 mm width X 50 mm depth X 1point6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray refer annexure-IV | Installation of 150 mm width X 50 mm depth X 1point6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray refer annexure-IV |
| 15 | 100000000013 Dismantling and shifting of existing ductable Indoor and Outdoor 2 X8point5 TR refer annexure-IV | Dismantling and shifting of existing ductable Indoor and Outdoor 2 X8point5 TR refer annexure-IV |