| 1 | Supplying, designing, fabricating, erecting, connecting, testing & commissioning outdoor type vermin & weatherproof totally enclosed double door type feeder pillar box front and back operated with hood (Canopy) on top, sufficient ventilation on sides, cubicle type, compartmentable fabricated out of 3mm thick CRCA sheet powder coated texture finishcolour. The panel shall be erected on 50mm x 50mm x 6mm thick MS angle iron frame and shall be pre-wired with PVC insulated copper conductor cable for monitors & Heat shrinkable PVC insulated sleeves, copper strips of appropriate current carrying capacity for connecting the incoming and outgoing MCCBs including reconnecting of existing serviceable cable / new cable with lugs & Brass cable glands. The panel shall consisting of following accessories :-(i) Colour coded copper bus bar 400 Amp rating 3 Phase & Neutral.(ii) Epoxy insulator 16 Nos .(iii) Digital Volt meter 0 to 500 V with selector switch -01 Set.(iv) Digital Ammeter with CT 0 to 100A with selector switch -01 set.(v) LED indicators R,Y &B - 01 Set.(vi) Angle Iron stand made out of 50x50x6 mm of suitable size & upto 0.6 mtr high above GL - 01 job.(vii) Internal connection to MCCBs/ MCBs with copper strip with as per current carrying capaicty- 01 Job.(viii) The panel shall provisioned compartments for fixing the following:- (a) MCCB three pole thermal range 250 Amps TPN, 415V, AC, 50 Hz, 36 KA (incomming)- 01 No. (b) MCCB 200 Amp TP, 415V, AC, 50 Hz, 25 KA (outgoing) - 05 Nos.(c) Fully Automatic Star-Delta Starters suitable for pump capacity 35 HP motor-04 Nos and01 Submersible Pump 35 HP-01(For Submersible Starter Dry run relay should be included in the panel Note: (1) Thepanel should be front & back openable and hinged door lock handle(2) The door should be tightenedwith rubber gasket. (3) Each compartment have door, lock and Main bus bar and MCCB/Starter input & outgoing connection should be suitable size copper bus bar, nut & bolts etc (4) All incomming & out going cable connected through new suitable size copper gland and aluminium lugs, nut & bots etc. Single Phase Preventor Should be fixed in all Starter Panel (5) This item include the cost ofall material. and commissioning and testing.Before Purchasing Panel the line diagram should be approved by Engineer In Charge.6) The Contractor should provide test reports before energizing (Insulation Resistance,Phase sequence Voltage test/Earth Continuity) and provide panel manufacutrer type test certificates and Factory Test as per IS 8623/IEC 61439 standards |
| 2 | Supplying, designing, fabricating, erecting, connecting, testing & commissioning outdoor type vermin & weatherproof totally enclosed double door type feeder pillar box front and back operated with hood (Canopy) on top, sufficient ventilation on sides, cubicle type, compartmentable fabricated out of 3mm thick CRCA sheet powder coated texture finishcolour. The panel shall be erected on 50mm x 50mm x 6mm thick MS angle iron frame and shall be pre-wired with PVC insulated copper conductor cable for monitors & Heat shrinkable PVC insulated sleeves, copper strips of appropriate current carrying capacity for connecting the incoming and outgoing MCCBs including reconnecting of existing serviceable cable / new cable with lugs & Brass cable glands. The panel shall consisting of following accessories :-(i) Colour coded copper bus bar 400 Amp rating 3 Phase & Neutral.(ii) Epoxy insulator 16 Nos .(iii) Digital Volt meter 0 to 500 V with selector switch -01 Set.(iv) Digital Ammeter with CT 0 to 100A with selector switch -01 set.(v) LED indicators R,Y &B - 01 Set.(vi) Angle Iron stand made out of 50x50x6 mm of suitable size & upto 0.6 mtr high above GL - 01 job.(vii) Internal connection to MCCBs/ MCBs with copper strip with as per current carrying capaicty- 01 Job.(viii) The panel shall provisioned compartments for fixing the following:- (a) Changeover Switch-Disconnector(Conforms to IEC 60947-3 , IS/IEC 60947-3) capacity 250Amps four pole.Make:- L&T,Legrand (b) MCCB three pole thermal range 250 Amps TPN, 415V, AC, 50 Hz, 36 KA (incomming)- 01 No. (c) MCCB 160 Amp TP, 415V, AC, 50 Hz, 25 KA (outgoing) - 03 Nos. (e) Fully Automatic Star-Delta Starters suitable for pump capacity 60 HP motor-03 NosNote: (1) Thepanel should be front & back openable and hinged door lock handle(2) The door should be tightenedwith rubber gasket. (3) Each compartment have door, lock and Main bus bar and MCCB/Starter input & outgoing connection should be suitable size copper bus bar, nut & bolts etc (4) All incomming & out going cable connected through new suitable size copper gland and aluminium lugs, nut & bots etc. Single Phase Preventor Should be fixed in all Starter Panel (5) This item include the cost ofall material. and commissioning and testing.Before Purchasing Panel the line diagram should be approved by Engineer In Charge.6) The Contractor should provide test reports before energizing (Insulation Resistance,Phase sequence Voltage test/Earth Continuity) and provide panel manufacutrer type test certificates and Factory Test as per IS 8623/IEC 61439 standards |
| 3 | Supply and Install MPP Can type heavy duty Capacitors of 10 KVAR as specified and directedNote:Removing the item is included in this quoted rate Cat Part No BCHMCH010B |
| 4 | Supply and Install MPP Can type heavy duty Capacitors of 5 KVAR as specified and directedNote:Removing the item is included in this quoted rate Cat Part No BCHMCH005B |
| 5 | Supply and Install MPP Can type heavy dutyCapacitors of 2 KVAR as specified and directedNote:Removing the item is included in this quoted rate Cat Part No BCHMCH002B |
| 6 | Supply and Fix C63A MCB of 3 Pole as specified and directed Note:Removing the item is included in this quoted rate |
| 7 | Supply and Fix APFC relay 8 step 415 V PFC(144 x 144)with 8 steps ,415 V as specifed and directed Cat Part No RG-8T-415 Note:Removing the item is included in this quoted rate |
| 8 | Supply and fix C Type 630 A MCCB 3 Pole 36 kA breaking capacity as specified and directed .Note: Removing the item is included in this quoted rate |
| 9 | M & L for removing existing contactor of 200 AC1 and incl Aux Contact ,supply and Fix Contactor of suitable size as specifeid and directed |
| 10 | M&L for demolition of existing concrete in ground floor and paving n exc. 15cm thickness ( below or above GL) cement concrete in foundation, filling & mass concrete type B2 (1:2:4) and all necessary accessories for making foundation forPump/ Motors |
| 11 | M&L for MS work in framed bracket of angles or Tees with web and flanges cut to shape , drilled and countersunk for screw including bending and welding angles as necessary gusset plate, riveting etc n exc 10 kg each bracket conforming to Fe290 Gde-E-165 with tie bar screwed ends, nut, washers and MS plates conforming to Fe290 Gde-E-165 all as required beneath Pumps and Motors as directed. |
| 12 | S & F in replacement NRV150 mm Class PN 1.6 Ball typeISI marked as specified and directed |
| 13 | S & F in replacement NRVBall type 200 mm Class PN 1.6 Ball type marked as specified and directed |
| 14 | S & Fin replacementNRV100 mm Class PN 1.6 Ball type marked as specified and directed |
| 15 | Supply & fixingin replacementof Cast IronFoot valvesBall type flanged with strainer of 200 mm dia including all types of fittings & confirming to IS specification complete all as specified andas directed.Make-Normex or Equivalent. |
| 16 | Supply & fixingin replacementof Cast IronFoot valvesBall type flanged with strainer of 100 mm dia including all types of fittings & confirming to IS specification complete all as specified andas directed.Make-Normex or Equivalent. |
| 17 | Demolition of cement concrete ( unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 18 | M & L for 75 mm thick PCC type D-2 1:4:8(40 mm graded aggregate) as in sub base for tiling complete all as specified and as directed |
| 19 | M & L for Chequered cement concrete tiles of 20 cm x 20cm x 25 mm thick with grey cement and pigment,set and jointed in neat cement slurry in floors including 15 mm thick screed bed or bedding layers in cement mortar 1:6 forlaying tiles complete all as specified and as directed. |
| 20 | M & L for cement concrete Type C2 1:3:6(using 40mm graded aggregates) as in plinth protection 75 mm thick finished top surface even and smooth without using extra cement complete all as specified and as directed. |
| 21 | M & L forprecast concrete interlocking paver block rubber moulded any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment including 30 mm thick sand cushioncomplete all as specified and as directed. |
| 22 | Supply & Fixing PVC door frame (50x47) mm made out of plain colour5 mm thich PVC Sheet reinforced with MS Square Tube, supplying & fixing in opening as per specification & drawing |
| 23 | Supply and fixing Factory made solid panel PVC door shutter 30 mm thick ( Style ) consisting of frame made out of MS Tubes for top & bottom rails.MS frame shall be covered with heat moulded plain colour PVC \" C \"Channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC Sheets for top rail , lock rail & bottomrail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC Sheet to be fitted in the MS Frame welded / sealed to stiles & rails with suitable PVC Sheet beading, jointed together with solvent cement,supplying & fixing in the frame at site as per specification & drawing. |
| 24 | Taking down chowkhats orframe with shutter (without taking off shutter from the frames) & removing from siteexc. 1.5 Sqm but n. exc 4Sqmeach complete all as specified and as directed |
| 25 | Taking down chowkhats orwith shutter (without taking off shutter from the frames) & removing from site n exc. 1.5 Sqm each complete all as specified and as directed |
| 26 | S & F Powder coated aluminium (minium thickness of powder coating 50 micron) work for doors chawkhat, partition etc with extruded built up standard tubular section/appropriate Z section of approved make conforming to IS-733 and IS:1285, fixing with dash fasterners of required dia and size including necessary filling up th gaps at junctions i.e. at top bottom and sides with required EPDM/rubber/neoprene gasket |
| 27 | S & F of anodised aluminium powder coated door shutters aluminum section weighing 0.55 kg/m incl necessary joining cleats, ruber neoprene packing handles 02 Nos in each door hinges anodised aluminium snap beading screws etc. complete all as specified and directed |
| 28 | S & F solid PVC wall lining consisting of 5mm thk plain colour PVC sheet inclusive of solvent cement and fixing at site on alluminium frame as specified |
| 29 | S & F sheet glass 5.5mm thkordinary quality and glazing wth oil putty in square n exc 0.5 Sqm |
| 30 | Dismantling fencing wire mesh , any tpe complete all as specified and directedby Engineer-in-Charge |
| 31 | Dismantling post, struts , (wood , steel or Rcc) any section incl. taking out embeded portion in concrete and making disturbed portiongood complete all as specified and as directed by Engineer-in-Charge. |
| 32 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in hard dense soil complete all as specified and as directed by Engineer-in-Charge |
| 33 | M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate ) as in foundation concrete for fencing post complete all as specified and as directed by Engineer-in-Charge. |
| 34 | S&F angle iron fencing post and struts including cutting tops to shape as directed, drilling holes, notching for wire etc , flat iron fillets ( for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer-in-Charge. |
| 35 | S&F flat iron of size 40x6mm as in columns as in clamps, holdfasts wall ties etc conforing to Fe-290 Gde-165 complete. |
| 36 | S&F MS Screw bolts ( machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut length exc. 5 cm but not exc 10cm long 11 to 15mm dia of shank complete all as specified and as directed by Engineer-in-Charge. |
| 37 | Supply only chain link MS galvanised fencing incl line wire mesh (12 gauge) size and any type of strands, rails, straining bolts etc incle provn of binding wire complete all as specified and as directed by Engineer-in-Charge. |
| 38 | Fixing only chain link fencingany mesh, size and type to any type of standards, rails, straining bolts etc incl provn of binding wire complete all as specified and as directed by Engineer-in-Charge. |
| 39 | M&L for round bars 10mm dia and over cut to length bent to shape required incl cranking, bending spirally for hoping for columns, hooking ends and binding with and incl MS Wire (annealed) not less than 0.9mm dia or securing with clips conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer-in-Charge. |
| 40 | Taking up the unserviceable cable of any type,and supply , laying andconnectingwith copper conductor including copper lugs in repair and PVC flexible pipes of suitable sizes ofcapacities from panel board to starter to motor for connection.Polycab PVC Insulated and PVC Round Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Flexible Cables for Voltage Grade 1100 Volts conforming to IS: 694:2010 of size 35 sqmm three core Make : Polycab,Finolex,Havells . |
| 41 | PVC Insulated and PVC Round Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Flexible Cables for Voltage Grade 1100 Volts conforming to.25 sqmm three core Make : Polycab,Finolex,Havells |
| 42 | Takingdown the unserviceable MCCB from the existing panel ,supply and fixing Moulded Case Circuit Breakers (AC 415 V)(Conforms to IS/IEC:60947-2),Adjustable Thermal & Fixed Magnetic,Rated Ultimate Shortcircuit Breaking Capacity-Ics=100% Icu at 415 .(36 to45 kA rms) MCCB 400 Amps TPN ,Make: Havells,Legrand ,Benlo |
| 43 | Moulded Case Circuit Breakers (AC 415 V)(Conforms to IS/IEC:60947-2),Fixed Thermal & Fixed Magnetic,Rated Ultimate Shortcircuit Breaking Capacity-Ics=100% Icu at 415 .(25kA rms) MCCB 250 Amps TPN ,Make: Havells,Legrand,Benlo , |
| 44 | Moulded Case Circuit Breakers (AC 415 V)(Conforms to IS/IEC:60947-2),Fixed Thermal & Fixed Magnetic,Rated Ultimate Shortcircuit Breaking Capacity-Ics=100% Icu at 415 .(25kA rms) MCCB 200 Amps TPN ,Make: Havells,Legrand,Belno |
| 45 | Moulded Case Circuit Breakers (AC 415 V)(Conforms to IS/IEC:60947-2),Fixed Thermal & Fixed Magnetic,Rated Ultimate Shortcircuit Breaking Capacity-Ics=100% Icu at 415 .(26kA rms) MCCB 160 Amps TPN ,Make: Havells,Legrand,Benlo |
| 46 | Moulded Case Circuit Breakers (AC 415 V)(Conforms to IS/IEC:60947-2),Adjustable Thermal & Fixed Magnetic,Rated Ultimate Shortcircuit Breaking Capacity-Ics=100% Icu at 415 .(26kA rms) MCCB 100 Amps TPN ,Make: Havells,Legrand,Benlo |
| 47 | Supply and Fix 4 Pole Power Contactors - Type MCX 4 Pole Power Contactors [8536] l Range from 160AcontactorMake: L & T/C&S/Havells or equivalent |
| 48 | S&F in repair Single phase preventor as reqd on site fpr protection of starter complete all as specified and directed Make: L & T/C&S/Havells or equivalent |
| 49 | Taking out carefully unserviceable Mono block pump set of 5 HP induction motor from its foundation by disconnecting suction /delivery pipes and electric connections and carrying to workshop (to and frow) for repair.The repair/ rewinding works consisting of following Job:- (i) Strip opening of pump set , removing worn out/unservicable component from the pump and replacement of defective parts as per existing size and make, greasing, oiling of parts as required for smooth functioning , reassembling the pump re-install at its existing position, providing electric and water pipe connections and testing complete for the following cpacity:Note : Cost of replacement of parts other than rewinding job required for smooth functioning of pump & re-winding of motor if required shall be measured and paid seperately. |
| 50 | M & L for repair & rewinding of electri induction motor by using super enamelled copper wire (Class -F) as per existing gauge ,heating and varnishing complete. The eletric motor shall be of 3 phase, 415 Volt AC induction type of any make. the repair work involves taking out burntout winding coiles from stator, cleaning of slots throughly, removing all dirt , grease and other unwanted particle, replacment of unservicableparts where required (as directed). Capacity of motor 5 HP complete all as directed by Engineer-in-charge.Note:(i) Retrieved winding wire will be the conractors property & necessary credit amont is deemed to be included in the quoted rate, hence no credit has been considered in credit schedule. Note :(ii) Spare parts other than rewinding job required for replacement shall be measured and paidseperatly as supply only. |
| 51 | Maintanence the intake channel of water from river to Jack will and fire pump for smooth water comming in jack well in all time for smooth functioning the water supply installation. The cost including providing the JCB for cleaning the floating particals ans sand with slit complet all as directed. |