| 1 | Dismandling of existingunserviceable cross armsof MS channel or angle any descriptionand in any position complete all as specified and directedby Engr - in - Charge. |
| 2 | Dismantling Insulators like 11 KV HT, Pin type, Disc type and loop insulators from existing Electrical Poles/ 2 pole/ 4 pole structure of any description and any size complete all as specified and as directed. |
| 3 | Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/replacement of broken/worn out components and insulators etc. |
| 4 | Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE , armoured, aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete. |
| 5 | Dismantling of ACSR Conductor of any size |
| 6 | Dismandlingof existingunserviceable concret poles/ struts of any Sizeand in any position complete all as specified and directedby Engr - in - Charge. |
| 7 | (a) Supply, install, testing and commissioning of Ring Main Unit 11 KV, 630A, 21 KA for 3 sec, Outdoor Manual Non-Extensible RMU 6 way RMU with 2 Nos. Incoming LBS and 4 Nos outgoing VCB (CVV) safeplus compact switchgear including foundation (PCC 1:4:8 using 40 mm graded aggregate type D2 for foundation)work all as specified and directed by Engr-in-charge . |
| 8 | (b) STANDARD AND MECHANICAL DATA:Metal enclosed switchgear: IEC 62271-200,General purpose switches: IEC 60265-1 Disconnectors and earthing switches : IEC 62271-102Switch fuse combination: IEC 62271-105Circuit breakers: IEC 62271-100Common cluases: IEC 60694Pressure of SF6 gas : 1.4 bar at 20°CCable bushings: DIN 47636Temprature class: -25°C - +40°C outdoor Degree of protection: SF6 tank-IP67, Front cover- IP 2X, Cable cover- IP 3X, Enclosure- IP 54Busbar: 240 sqmm Cuearth bar (external): 120 sqmm Cu - Bolt dimension: M10Thickness of Stainless steel tank: 3 mmColours: front cover- RAL 7035, Side and cable cover- RAL 7035, Enclosure IS 632(c) ELECTRICAL DATA - 12 KV- 28 KV- 1 min:Nominal voltage: 11 KVRated frequency: 50 HzRated current bus bar : 630ARated current cable switch disconnector : 630AShort time withstand current: Cable switch disconnectorwith interface C (400-bolt) bushing: 21 kArms 3 sec, Vacuum circuit breaker with interface C (400-bolt) bushing: 21 kArms 3 secRated current for transformer T-off: 630AImpulse withstand voltage: To earth and between phases: 75 kvInsulation level: Power frequency 1 min: 28 kv |
| 9 | (d) C - Load Break Switch: safeplus C is a cable switch module with a three-position load break switch and earthing switch, busbars, interlocking and earth bar.SafePlus type C: Cable switch 12 kv, 630ACable cover standardCable bushings interface C (400 bolted), 630A, standardCapacitive voltage indication fixed type VPIS 9-15 kvCable support bars, standard for 1-way unit(e) V- Vacuum Circuit Breaker : SafePlus V is a Vacuum Circuit Breaker module with vacuum circuit breaker, three position isolator/ earthing switch, busbars, interlocking, earthbar and stored spring energy mech (EL- mech). SafePlus type V: Vacuum circuit breaker 12 kv, 630ACable cover standardSelf-powered over current and earth fault protection relay with RS485 port type ADR241SCapacitive voltage indication fixed type VPIS 9-15 kvCable bushing interface C (400 bolted), 630A Cable support bars, standard for 1 way unitRing core current transformer type 100/1 A, 2.5 VA, 5P10 |
| 10 | (a) Supply, install, testing and commissioning of Ring Main Unit 11 KV, 630A, 21 KA for 3 sec, Outdoor Manual Non-Extensible RMU 4 way RMU with 2 Nos. Incoming LBS and 2 Nos outgoing VCB (CVV) safeplus compact switchgear including foundation (PCC 1:4:8 using 40 mm graded aggregate type D2 for foundation)work all as specified and directed by Engr-in-charge . |
| 11 | (b) STANDARD AND MECHANICAL DATA:Metal enclosed switchgear: IEC 62271-200,General purpose switches: IEC 60265-1 Disconnectors and earthing switches : IEC 62271-102Switch fuse combination: IEC 62271-105Circuit breakers: IEC 62271-100Common cluases: IEC 60694Pressure of SF6 gas : 1.4 bar at 20°CCable bushings: DIN 47636Temprature class: -25°C - +40°C outdoor Degree of protection: SF6 tank-IP67, Front cover- IP 2X, Cable cover- IP 3X, Enclosure- IP 54Busbar: 240 sqmm Cuearth bar (external): 120 sqmm Cu - Bolt dimension: M10Thickness of Stainless steel tank: 3 mmColours: front cover- RAL 7035, Side and cable cover- RAL 7035, Enclosure IS 632(c) ELECTRICAL DATA - 12 KV- 28 KV- 1 min:Nominal voltage: 11 KVRated frequency: 50 HzRated current bus bar : 630ARated current cable switch disconnector : 630AShort time withstand current: Cable switch disconnectorwith interface C (400-bolt) bushing: 21 kArms 3 sec, Vacuum circuit breaker with interface C (400-bolt) bushing: 21 kArms 3 secRated current for transformer T-off: 630AImpulse withstand voltage: To earth and between phases: 75 kvInsulation level: Power frequency 1 min: 28 kv |
| 12 | (d) C - Load Break Switch: safeplus C is a cable switch module with a three-position load break switch and earthing switch, busbars, interlocking and earth bar.SafePlus type C: Cable switch 12 kv, 630ACable cover standardCable bushings interface C (400 bolted), 630A, standardCapacitive voltage indication fixed type VPIS 9-15 kvCable support bars, standard for 1-way unit(e) V- Vacuum Circuit Breaker : SafePlus V is a Vacuum Circuit Breaker module with vacuum circuit breaker, three position isolator/ earthing switch, busbars, interlocking, earthbar and stored spring energy mech (EL- mech). SafePlus type V: Vacuum circuit breaker 12 kv, 630ACable cover standardSelf-powered over current and earth fault protection relay with RS485 port type ADR241SCapacitive voltage indication fixed type VPIS 9-15 kvCable bushing interface C (400 bolted), 630A Cable support bars, standard for 1 way unitRing core current transformer type 100/1 A, 2.5 VA, 5P10 |
| 13 | Supply, install and testing Earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 32X6 mm as earthing lead by means of bolts, nuts , check nuts and washers of galvanised iron or steel drawn through 40 mm dia light grade GI pipe as shown in electrical plate No. 3 of SSR Part-I of 2009 including necessary excavation and earth work GI pipe 20 mm dia light grade for watering PCC chamber with PCC cover in cement concrete 1:2:4 type B1 (20 mm graded aggregate) , funnel, wiremesh, charchol, dust , salt etc connected to earthing test point all as specified by Engr-in-Charge.Note: Earth strip and GI protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. |
| 14 | Supply laying Jointing & testing cable XLPE insulated screened PVC bedded galvanised steelstrip or wire armoured electric power cable heavy duty withstrandedaluminium conductor 11000 volts grade earthed with cross sectional area of size 3 core 95 sqmm all as specified and as directed. |
| 15 | Excavation in trenches not exceeding 1.5mtrwide & not exceeding 1.5 mtr in depth for laying LT cable, soft/loose soil complete all as directed. |
| 16 | Returning, filling in trenches with soil, including spreding, leveling, watering & well ramming, in layers not exceeding 25 cm each complete |
| 17 | Removing surplus excavated material (soil) to distance not exceeding 50 Mtr & depositing where directed at level not exceeding 1.5 mtr above the starting point. |
| 18 | Supply and laying unreinforced precast cement concrete cable covers, class HV, type-1 flat, size 300 mm X 180 mm X 40 mm in trenches for cable protection, embossed with HT 1100 Volts Electric on the top surface complete all as specified and as directed by the ENgr-in-Charge. |
| 19 | Material and Labour clean dry river sandin trenches/ducts for cushioning to cable, 8 cm in depth before laying the cable and 15 cm in depth after laying the cable complete all as specified. Note:- Punned thickness shall be measured and paid. |
| 20 | Material and labour for GI pipe light grade complete with fittings laid in floor/ trenches/ wall / pole as cable protection of 100 mm dia including 02 Nos clamps with nuts, bolts fixed to pole for cable protection all as specified and directed by Engr-in-Charge. |
| 21 | Material and labour coarse stone aggregates, grading I 90 to 40 mm size or grading 2, 63 to 40 mm granite, trap or basalt size laying at substation complete including cleaning the bushes, vegetation and leveling, removal of surplus soils complete all as specified and directed. |
| 22 | Material and labour for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 MPA working pressure complete all as specified and directed by Engr-in-Charge. |
| 23 | Supply and fixing disc type Insulator (single disc assembly) in repair porcelain vitreous, white brown or green 145 mm height and 255 mm dia ball and socket type with tension clamp galvanized iron nut for conductors working pressure 11000 volt grade complete. |
| 24 | Material and labour for stay assembly 20mm dia rod complete with accessories as shown in electrical plate No 1 (Loop type insulator , stay clamps, excavation and concrete measured separately) all as directed.Make: CAPCON/JAIPURIA BROTHERS/HINDALCO |
| 25 | Material and labour loop type insulator , vitreous porcelain, white , brown or green large size with overall dimensions 90 X 140 mm, clearance of hole 16 mm compete. |
| 26 | Material and labour Galvanised steel wire 3.15 or 4 mm dia stranded 7/1.6 mm complete all as specifiied and directed. |
| 27 | Material and labour for PCC 1:2:4 type B-0 using 12.5 mm graded BT stone aggregate as in bed block for hold fast or coping including necessary form work complete all as specified. |