| 1 | 1.0) Carrying out round the clock Operation, supervision, look after, caretakingof existing E&M services i.e. IEI, water supply pump sets, fire fighting pump sets, fire alarm system, DG sets, lift rescue operation,submersible pump sets, dewatering pump sets, internal street lights, dry type transformer sub-station with HT and LT panels, mechanical ventilation system i/c lift pressurization system, PA System etc. as per inventory attachedi/c routine, preventive and breakdown maintenance,arranging / providing all specialized tool & plants to keep all services / equipments operational upto standards, as perinventory and terms & condition attached by deploying the following staff at site as per direction of engineer-in-charge.a).Skilled person (Wireman cum operator) - 3 nos. (1 no. each in day shift)b).Unskilled person (Khallasi) - 3 nos. (1 no. in each shift) |
| 2 | 2.0) Lifting of existing submersible pump seti/cGI pipe and dismantling of cable upto reqd. depth etc. complete as reqd. |
| 3 | 3.0)Lowering of existing submersible pump seti/c re-assembling of GI pipe, connection, testing etc. complete as reqd. |
| 4 | 4.0) Supplying of following sizes of PVC insulated and PVC sheathed/XLPE aluminium conductor armoured power cable of 1.1 KV grade i/c connection & testing etc. as required and as per technical specification enclosed.4.1)2c x 10 Sq.mm |
| 5 | 5.0) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 5.1)Up to 35 Sq.mm |
| 6 | 6.0) Supply& Laying of 3c x 4 sq. mm. PVC insulated submersible cable1.1 KV grade including testing etc. as per required. |
| 7 | 7.0) Reparing of following parts of existing pump 30 HP centrifugal pump cou;ped with existing motor on MS based channel. Cartage to work shop and back i/c painting, greasing of ball bearing impleller shaft, re-fixing the same with the existing motor on foundation i/c connection testing and commissioning on load etc. complete as required. |
| 8 | 7.1)Remetalling & balancing of impeller. |
| 9 | 7.2)Shaft reparing |
| 10 | 7.3)Replacement of gland sleeve |
| 11 | 7.4)Replacement of Neck ring |
| 12 | 7.5)Replacement of Ball Bearing |
| 13 | 7.6)Making of gland dori, greasing, packing sheet, nut-bolts |
| 14 | 8.0)Repairing of following parts of existing15 HP centrifugal pump coupled with existing motor on MS based channel, cartage to work shop and back i/c painting, greasing of ball bearing, impeller shaft, re-fixing the same with the existing motor on foundation i/c connection testing and commissoning on load etc, complete as required. |
| 15 | 8.1) Rematlling and balancing of Impeller |
| 16 | 8.2) Shaft reparing |
| 17 | 8.3) Replacement of gland sleeve |
| 18 | 8.4) Replacement of Neck ring |
| 19 | 8.5) Replacement of Ball Bearing |
| 20 | 8.6) Making of gland dori, greasing, packing sheet, nut-bolts |
| 21 | 9.0) Dismantaling of the existing burnt out motor coupled with existing centrifugal pump installed on MS based channel i/c to and fro and rewinding the 30 HP induction Motor with Coper wire and, re-fixing the same with the existing pump through flexible/rigid coupling with nut bolt washer i/ctesting and commissioning on load etc. complete as required. |
| 22 | 10.0) Dismantaling of the existing burnt out motor coupled with existing centrifugal pump installed on MS based channel i/c to and fro and rewinding the 15 HP induction Motor with Coper wire and, re-fixing the same with the existing pump through flexible/rigid coupling with nut bolt washer i/ctesting and commissioning on load etc. complete as required. |
| 23 | 11.0)Reparing & rewinding of existing 5 HP to 7HP submersible pump set i/c remettling of impeller, bush, neck ring etc, complete as reqd. |
| 24 | 12.0) Supplying and fixing 5 amps to 32 amps rating. 240/415 volts, 10 KA \"C\" curve, mainture circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as reqd. |
| 25 | 12.1) a)-Single pole |
| 26 | 12.2) b)-Double pole |
| 27 | 12.3) Triple pole |
| 28 | 13.0)Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 29 | 13.1)63A |
| 30 | 13.2) 100A |
| 31 | 14.0)Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 32 | 14.1) 5/6 A switch |
| 33 | 14.2) 3 pin 5/6 A socket outlet |
| 34 | 14.3) 15/16 A switch |
| 35 | 14.4)6 pin 15/16 A socket outlet |
| 36 | 15.0) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit including credit for dismantled material etc.as required. |
| 37 | 15.1)3 x 1.5 sq. mm |
| 38 | 15.2)3 x 2.5 sq. mm |
| 39 | 15.3)3 x 4sq. Mm |