| Sl. No. | Item Description |
| 1 | Interior |
| 2 | Partitions |
| 3 | Drywall solid partition system |
| 4 | 97.0mm thick Gypwall Habito partition consist ofMetal framework having maximum reachable height of 3600mm satisfying L/240 criterion at 200Pa, possessing fire rating of 60mins, tested in accordance to BS-476 Part 20 & 22 & sound insulation (Rw) of 43dB, tested in accordance to ISO 10140-2/ASTM E90 & spectrum adaption term as per ISO 717-1, having U-value of 0.425W/m²K & Heavy duty rating as per BS 5234 part. Partition comprises of single layer, tapered edge Gypsum Board, certified GreenPro by CII & strategic location of manufacturing plants results in lower carbon emissions. Partition includes single layer of 12.5mm thick®Habito conforming to IS 2095 Part 1:2011 / EN 520: 2004 - Type A,D,R,I,HB having flexural strength – {Longitudinal > 1010N & transverse > 550N} on both side of framing.™ Metal frame work, in compliance with BS EN 14195 & manufactured using CR1 Grade Steel as per IS 513, having yield stress of 300MPa & tensile strength of 340MPa with surface finish of AZ150 as per IS 15961/AS 1397 & tested for 500hrs of salt spray test as per ASTM B117, includes 70x34x36x0.5mm™ C-Stud with lip of 6.5mm and H-cutout on web enabling the services to pass, having moment of inertia 61909mm4 about major axis, positioned at 610mm c/c in 72x32x32x0.5mm™ Floor Channel & 72x32x32x0.5mm™ Ceiling Channel with flanges bend at 5° acute angle. Floor & Ceiling Channel is anchored with® Rawl plug Ø8x45mm having Pull Out strength of 6.8KN or Nail**, fixed at 600mm c/c in zig zag manner. 70x40x40x0.5mm™ Noggin Channel to be fitted at the horizontal joints of board. ®Habito board strip is placed between ceiling channel and soffit when fire rating is more than 30mins® Boards to be Screw fixed with®Habito Screw of 25mm with 30nos per m2 at 300mm at centre and 150mm at periphery. 50mm Glass wool of density 20kg/m3 shall be placed in Metal framework with the help of holding Clip. Edges & joints to be finished with® Pro-Fill JC conforming to ASTM C475 &®Paper tape. Periphery & cut-outs of the partition to be treated with suitable Fire & Acoustic Sealant. All the performance test are carried out at NABL accredited/ government approved lab. |
| 5 | Rate to include provisions to be made for fixing writing boards and soft board fabrics on to it. Rate to include on coat of altek patty and two coats of acrylic emulsion paint finish all complete. Rate to also include 50mm high aluminium skirting from JEB or Bottomline. |
| 6 | Rate to include cutouts with necessary support frames for services such as HVAC ducting, return air, and fresh air. No additional cost to be claimed for the same |
| 7 | Wall lining with Habito beside block wall for better thermal insulation and acoustic performance |
| 8 | 62.5mm(Min.) thick Wall lining with C-stud partition which includes single layer of tapered edge 12.5mm thick®Habito conforming to IS 2095 Part 1:2011 / EN 520:2004 - Type A,D,R,I,HB having flexural strength – {Longitudinal > 1010N & transverse > 550N} of size 1219x2438mm mmscrew fixed to C-stud which is placed adjacent to brick/RCC wall. 48x0.5mm™ C-stud {Material-IS 513,Y/S-300Mpa, Finish - AZ150 (IS 15961)} placed at 610mm c/c in 50x0.5mm™ {Material-IS 513,Y/S-300Mpa, Finish - AZ150 (IS 15961} floor and ceiling channel. Floor & Ceiling channel is anchored to the floor & True ceiling using® Rawl plug Ø8x45mm {Material-IS 513 CR1 grade, Zinc coating, Pull Out Load-6.8kN for M30 concrete grade} /Hilti Nail anchor fasteners at 600mm c/c in centreline manner. A™ Noggin channel {Material-IS 513,Y/S-300Mpa, Finish - AZ150 (IS 15961)} of 48x0.5mm width has to be provided at the horizontal joints of outer boards. Single layer of® boards to be screw fixed with® drywall screws of 25mm at minimum spacing of 300mm at centre and 150mm at periphery. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with® Pro-Fill Jointing compound Air Dry (Conforms to ASTM C475),® Joint Paper tape. The junction of the partition with masonry & all penetration through the partition has to be treated with Acoustic sealant. All other detailing and specifications to be followed as per approved drawing of. |
| 9 | Vertical drop partitions till lintel level - From 2.7m to 3.8m level, bottom of true roof slab. |
| 10 | Supply and fixing vertical drop partitions from slab bottom at 3.8m level till lintel of item no\"s 5 & 6The vertical drop to be made up of 50 x 25 mm aluminium section framework at every 600mm c/c and to be strengthened appropriately with anchorfastners to the slab soffit and the civil walls at the ends. Note that the vertical drops are to be sturdy enough to hold the TG glass partition with aluminium framework. The vertical drop frame to be panelled with 2x12.5mm gypsum board on both sides of the framework. All joints and gaps to be sealed with silicon sealant to make the partition air tight. |
| 11 | Rate to include one coat of altek patty and two coats of acrylic emulsion paint finish all complete. |
| 12 | Rate to include cutouts with necessary support frames for services such as HVAC ducting, return air, and fresh air. No additional cost to be claimed for the same |
| 13 | SINGLE GLAZED SYSTEM - 10 mm TOUGHENED GLASS PARTITION - 1200 - 2700 mm high |
| 14 | Supply and Installation of Clipper Sleek Series aluminium profile for single glazed straight partition with top, bottom and side profiles of size 21mmx30mm black anodizedfinish with suitable gaskets for insertion for 10 mm thickToughened glass. It consists of 2way polycarbonate profile, 90 deg L junction, T junction and suitable fasteners for fixing profiles. Partition Height 1500mm |
| 15 | SINGLE GLAZED SYSTEM - 10 mm TOUGHENED GLASS PARTITION - 0 - 2700 mm high |
| 16 | Supply and Installation of Clipper Sleek Series aluminium profile for single glazed straight partition with top, bottom and side profiles of size 21mmx30mm black anodizedfinish with suitable gaskets for insertion for 10 mm thickToughened glass. It consists of 2way polycarbonate profile, 90 deg L junction, T junction and suitable fasteners for fixing profiles. Partition Height 2700mm |
| 17 | DOUBLE GLAZED SYSTEM |
| 18 | Supply and installation of Clipper Influence Series aluminium profile for double-glazed straight glass partition with top, bottom and side profiles of 82mmx38mm black anodised finish with suitable gaskets for insertion of 10mm thick clear toughened glass+Airgap + 12mm thick clear toughened glass. It consist of 2way polycarbonate profile and suitable fasteners for fixing profiles Price including supply and installation. Glass partition Height considered as 2700mm - The supplied toughened glass to have Low E glass from ST Gobain make or equivalent. |
| 19 | Moveable & Collapsible acoustic partition system. |
| 20 | ACOUSTIC OPERABLE PARTITION – VARIFLEX SOLID 100 (SEMI AUTOMATIC) or equivalentGeneral Description and Acoustical PerformanceOperable Partition consisting of series of individual flat elements of 100 mm thick travelling along the ceiling track assembled to form a solid wall. The entire system must function as a solid wall and even when closed should reveal minimal screws, fixing or other similar solid metal parts. The sound insulation of the operable partition should be 50/52/55 db* tested under third party reputed laboratory in accordance to EN 20140-3. The test certificate should show the make and model of the system.ConstructionElements must be constructed of a torsion-free steel horizontal tube frame and torsion-stiff vertical aluminium profiles, bolted together to make the element strong and sturdy. The frame must be clad either side with 16mm MDF panels hung in acoustic free suspension from the panel frame. The panel skin shall be installed on site and able to be replaced without totally disassembling the panel frame. The element must be constructed in accordance with the specified sound insulation requirements. The elements must be inter-connected by means of a positive locking concave/convex aluminium profile with an integrated magnetic strip and sealing lip having a linear attraction of 40N/m. The spindle mechanism in every element should be connected to the top and bottom horizontal seals which should be constructed of aluminium plates with flexible rubber at the contact point. Specially formed polyurethanecorner rubber seal to be provided for overlapping acoustic seals horizontal sealing strip. Operation (Semi Automatic)Each element must have a spindle mechanism which should be connected to the spring loaded top and bottom retractable seal. The spindle mechanism should be operated driven by a 24V DC electric motor. The power supply should be conducted from element to element via end-face plug contacts and a system connection to the mains supply via a plug-in power supply unit and a central master switch to be provided. In order to ensure functional efficiency even in the event of a malfunction or fault (power failure) an emergency unlocking device shall be provided for all the elements. The horizontal top and bottom seals must be retracted as per the operating mechanism and should ensure a contact pressure of 800N when the seals are completely extended. The spring loaded retractable horizontal seals should also be able to adjust to minor floor undulation for better acoustic efficiency. The seal spindle mechanism must be accessible while the panel is hanging for servicing and adjustment if necessary. Total disassembly of the panel frame to access internal components is not acceptable. No fixed sweep seals allowed in top and bottom of the element that would rub against the track or floor while moving the element. Telescopic / End Closure ElementThe telescopic element or the end closure element must open and close 120mm horizontally through an additional telescopic panel made of 16mm MDF provided and fixed to the telescopic element. The movement of the telescopic panel and the operation of the horizontal top and bottom seal and must be operated by a single mechanism. The telescopic element must maintain all the same quality criteria as the other elements.Pass Door (Optional)If pass door elements are required thethickness of the element needs to be 100 mm with a portal frame consisting of rigid steel profiles and two side post\"s with pressure tubes. Additional interlocking and centring of doors stiles via automatically operated floor pins to be provided. Door leaf to be flush with face of Partition. Door leaf should consist of steel frame and automatically operated retractable floor seal. Sealing mechanism (top seal and floor plugs) to be operated at the edge of the element with integrated door leaf mechanism (no additional manual operation).Element Suspension (for single element weight < 500 kgs)**An aluminium track profile shall be installed to ensure easy, low-noise operation of the elements. Additional track cladding must not be necessary. It shall be possible to implement all right-angled and positive-guidance stacking track assemblies with this track design.Each element must be suspended on the aluminium track by \"maintenance free\" multi-directional trolley capable of withstanding a minimum load of 500kgs per element. Additional ledge should be provided on the track for the movement of the trolleyproviding the extra strength to the track and smooth movement of the element. The trolley shall consist of a four sided die cast aluminium body. Multidirectional ball bearing wheels shall be steel-rimmed mounted to each of the four side and shall be capable of navigating track intersection. The trolley shall incorporate four nylon horizontal navigating wheels, mounted to the top of the trolley body, to provide guidance for smooth operation. To allow for minor structural sag in the ceiling, the elements must be designed for easy height adjustment without the need to open up either the ceiling or the element. |
| 21 | Doors |
| 22 | Clipper Influence Series System for single Glazed Stile Glass door. |
| 23 | Supply and Installation of Clipper Sleek series Door frame size 55X32mm and Single leaf single glazed stile door frame size 40 x 82 mm with black finish withHardware -make Flush Hinges (5 Nos) & 300mm offsetHandle with NSL dead Lock 35mm backset, oval escutcheons , strike plate, EPC cylinder both side key-70mm and SGF840 Exposed Door closer with Hold Open unit with 11.52mmlaminated glassand necessary seals to be provided all around the door frames and drop down seal .-Single leaf Glass Door 1000x2400mm |
| 24 | Clipper Influence Series System for double Glazed Stile Glass door. |
| 25 | Supply and installation of Clipper Influence series Door frame size 82X38mm and Single leaf Double glazed stile door frame size 40 x 82 mm with black finish withHardware -make Flush Hinges (6Nos) & 300mm offsetHandle (02nos) with NSL dead Lock 35mm backset, oval escutcheons , strike plate, EPC One Side Key other side knob-70mm and concealedDoor closer with Hold Open unit with 6mmtoughened glass+ airgap+8mm toughened glass and necessary seals to be provided all around the door frames and drop down seal .-Single leaf Glass Door 1200x2400mm |
| 26 | Steel doors - Providing and fixing clean room steel doors with 1 hour fire rated door, drop leaf hinges and seal. Size 1000mm x 2400mm (Shakthimet or equivalent). Rate to include vision panel, Door closer of approved make or equiv, handles, locks etc. all complete. |
| 27 | Solid flush doors - finished with laminate as per drg. Rate to include all hardware etc. all complete with Door closer(approved make or equv)- 1000x2400mm with a 200 mm x300 mm vision panel and louvers of size 150 x 300mm in the lower panel of the door. Door frame with 75X40mm teak wood to be considered with enamel paint finish. |
| 28 | Solid flush doors - finished with laminate as per drg. Rate to include all hardware etc. all complete with Door closer(approved make or equv)- 1000x2400mm. Door frame with 75X40mm solid teak wood to be considered with natural melamine polish finish and rebate as per standards. |
| 29 | Miscellaneous |
| 30 | Panelling on wall / column - Laminated finish - Providing and fixingwith 12mm plywood fixed directly on wall or column finished with 1m laminate as per design till 1200mm leveland soft board above it till 2400mm level which will be paid separately / drawing all complete. |
| 31 | Same as above but panelling to be done with 6mm lacquered glass - make (basic rate to be 400/sft) - With 6 mm commercial ply backing and to be flushed with the rest of the panelling surface level. |
| 32 | Panellingoncolumns - Laminated finish- Providing and fixingwith 12mm MDF over framework of Aluminium sections of 25x50 mm directly on columns finished with 1m laminate as per design / drawing all complete. Gap of boxing to be 50 mm. |
| 33 | Same as above but panelling to be done with 6mm lacquered glass - make (basic rate to be 400/sft) |
| 34 | Acoustic panelling - Providing and fixing acoustic boards with 12mm thick Synthetic wool petpanels (Basic rate not less than Rs 100/sft).The panel to be fixed on to the wall or partition with Aluminium L trim for a solid wall and dry wall surface application. |
| 35 | EOS 500 ROLLERSHADESSPECIFICATIONS FOR approved make or equivalentProviding and fixing Roller Blinds manufactured by Hunter Douglas, to the following specifications:TheDRIVEUNITshallbeofpatentedclutchforquick,easyandsafeinstallation, molded plastic with steel spring support and inserted into the tube end. It shall be driven by a ball chain pulley with ball chain and can be positioned at right side or left hand side of the Shade. The Shade when lowering or raising, shall be automatically locked in position upon release of the ball chain by means of a built in friction lock. Universal clutch for left and right hand operation. Chain Gear Ratio of 1.75:1The END PLUG shall be molded of plastic with a steel location pin. The plug shall be inserted into the tube end. (Opposite to the Drive Unit) for ease of installation.The SUPPORTBRACKETS(Bracket55)shall be of coated steel & provided with covers and used in right hand or left hand positions differentiated by the acceptance oftheoftherectangulardriveunitsupportortheroundidlerplugpin.Canbe installed a) On Face b) Ceiling Mount c) On Frame d) in RecessThe Bracket should be protruding outside maximum of 80mmTheROLLERTUBEshallbeofextrudedaluminiumwith50mmdiameter&skin thicknessof 1mmandshallincorporateakeywayintegralwiththetube to accommodate the spline.The BOTTOM RAIL shall be a Flat Bottom rail of Aluminium Extruded as a stiffening element inserted into a bottom rod pocket. The material may be timber, PVC covered steel tube or VB Bottom rail |
| 36 | Blackout Fabric Specification:Basic Material: 100% PolyesterFabric Width: 200 / 250 cmFabric Weight: 270 - 295 g/m2Thickness: 0.50 mmFinishing: Blackout Fabric, reverse & front side pigment colour coatedColour Fastness: > 5-6Rubbing Fastness Depending on colourShrinkage (%)- Warp: < 0.5 % Weft: < 0.5 % |
| 37 | Screen Fabric Specification:Fabric Specification 3%Openness:Mario Fabric made up of 24% Polyester and 76% PVC coated110tex Tilter Basket weave of thickness 0.61mm(ISO 2286-3) and weighing 485gsm±5%(ISO 2286-2)with openness factor of 3% .UV Screen Up to 97% ,The tear resistance (Warp: >_120N &Weft: >120N) As perISO 4674, and Fire, Smoke classification FR (US) - NFPA 701 TM#1 &BS (GB) - 5867 Part2 Type B & B1(CN)-GB50222. Break Resistance (Warp: >1600N/5cm & Weft: >1800N/5cm as per (ISO 13934-1) Bacterial & Fungal Resistance ASTM G21-09, ASTM E 2180-07 Reduce more than 99.9% of bacteria. Greenguard GOLD, EN71 Part 3:1994. Colour fastness Grade 6 ISO105 B02:2014 >_4.0 AATCC TM 16.3-2014; Option 3; Xenon Arc Lamp, Health/Safety-Oekotex Standard 100 Class IV certification |
| 38 | Motor Specification:ThesearequietACmotorsthatareidealforrollershades.Theavailablestandard mechanicallimitversionofferssimpleadjustmentoftheupperandlowerlimit positionswithpreciselimitswitches.MotorscanbeoperatedfromstandardAC switches.Nominal Torque (Nm): 4 Output Speed: 26 rpmFinal limit Position range: 40 revolutions Mains Voltage: 230V / 50HzPower Consumption: 90 WNominal Current Consumption (A): 0.39 Operating Mode: 4 MinDegree of Protection: IP 44 |
| 39 | White boards -Magnetic type with 3M coated film on surface- Rate to include providing Aluminium trim all around. |
| 40 | Pelmets - Providing and fixing of laminated pelmets with 18mm ply 200 mm deep and 200 mm wide with laminate finish from both internal & external surfaces. Edges to be finished with PVC edge banding of approved make or equivalent |
| 41 | Boxing - Providing and fixing boxing in locations as per drg. With 12mm mdf over necessary framework of Aluminium sections of 50x25mm with 1mmlaminate finish. Rate to include providing grooves, shapes all as per drg., hardware all complete. Surface area of panelling around the boxing will be measured for payment. |
| 42 | Dirt matting -From approved make or equivalent as per approved sample. |
| 43 | Skirting |
| 44 | Providing and fixing proprietary Anodized Aluminium Skirting of 50mm high, as per details and Architect\"s approval.Bottomline or equivalent. |
| 45 | Trap doors |
| 46 | Providing and fixing factory fabricated Trap doors in the false ceiling as per service requirements as follows. Trap Door Frames are made of Aluminium Alloy 6063 with the Thickness of 1.5mm and 30mm width.• Core Panel made out of Synthetic Board (12.5mm thickness).• Corners of the frame are reinforced with non-corrosive galvanized steel angles with Shutter removable hinges.• Safety latch secured by galvanized angle on the inner side of frame Various dimensions available.• Shutter to be pressed open with click lock.• Self-activating pressured spring locks. Certified to be used for 500 times (open and close).• Shutter extra supported with guard hook and SS rope for safety purpose. |
| 47 | Material:Frames made from stable Aluminium profile.Closing / Opening Mechanism:2 x Spring loaded galvanized steel locks with safety roped hook.Connecting Frame Parts:Galvanized steelMaterial Inlay:USG Boral (MR) Moisture resistant gypsum board / Synthetic Board /Aluminium Panel.Material Screws:Phosphate, rust-prevented, spike protected with cap.Standard Sizes:• 200 x 200 mm• 300 x 300 mm• 400 x 400 mm• 450 x 450 mm• 500 x 500 mm• 600 x 600 mm• 900 x 900 mm• 600 x 900 mm• 600 x 1200 mm• 1200 x 1800 mm• Any Custom size’s also made as per client requirement\"s. |
| 48 | Architrave |
| 49 | P&F Beech wood architrave 40mm x 18mm as per design and detail around existing doors, shutters. Rate to include fixing the same on walls, mitre joining at the corners and melamine polish as per desired shade. |
| 50 | To close wall openings with mdf board of 12mm thickness and to accommodate services like ducts of specific sizes and sealed and finished with mdf beading all around the opening made in the board. To include finish with PE paint as well. |
| 51 | 3MM - Epoxy Self Levelling Flooring System |
| 52 | Note: All the new flooring substrate shall be allowed to cure and dry completely according to standard practice. The substrate shall be of minimum M20 grade with VDF / IPS finish. The base should be hard & strong (minimum tensile strength of 1.5 N/Sqmm). The base should be free from random cracking & potholes. Flatness of the base should be checked for level to ensure that the specified thickness of treatment can be applied over the whole area. All the expansion & movement joints should be properly cut and maintained for terminations. The preferred method of surface preparation is by mechanical means. The substrate shall have moisture content of less than 5%. This product shall not be applied on the floors that are known to have rising moisture or have relative humidity of greater that 75% at the time application. All application shall be not carried out where temperature less than 10 Deg C or above 40 Deg C |
| 53 | Surface preparation:- Cleaning the entire floor surface to make it free from dirt, dust, loose particles, wax, polish, efflorescence, laitance, curing compound and other contaminants by using suitable equipment\"s like wire brush, grinding all sharp edges to make it flush with the surface, etc and undulations should be levelled with epoxy mortar etc and complete as per manufacturer\"s specification. |
| 54 | Priming:- Providing and applyingAsian or equivalent Apcoflor HFP 120/ Apcoflor HFP 130, solvent free epoxy primer coat of coverage 200 gms / sqm, using a brush or short / medium spike roller at a time gap of 8 hrs by ensuring a uniform coating is achieved and compensated the differences in surface porosity, allowing second coat to dry for 24 Hrs, etc and complete as per manufacturer\"s specification. |
| 55 | Epoxy Self Levelling screed:-Providing and laying,Asian or equivalent Apcoflor LSC3high performance, self levelling epoxy resin flooring system by mixing all 3 components using heavy duty slow speed drilling machine fixed with mixing paddle, pouring of mixed material on the primed surface and spreading it using suitable trowel / pin rake trowel at 2mm thickness, gently rolling the spike roller to remove the entrapped air, etc and complete as per manufacturer\"s specification. |
| 56 | Epoxy self levelling Topping : Providing and laying, Asian or equivalent Apcoflor SL1 TC, high performance, epoxy resin self levelling flooring system at 1mm thick by mixing all components including Pigment, using heavy duty slow speed drilling machine fixed with mixing paddle, pouring of mixed material on the primed surface and spreading it using suitable trowel at 1mm thickness, gently rolling the surface of Apcoflor SL1 TC using spike roller to remove the entrapped air, etc and complete as per manufacturer\"s specification. |
| 57 | Providing and fixing of Aluminium L profile of size 12mmx12mm on top open edge oflaminated wall panelling. |
| 58 | Providing and fixing ofss Transition profiles in the flooring for covering the jointsbetween two different flooring materials and even for serving as a transition profile between two different floor levels. The ss profile is to be 32mm in width and to have a brushed finish. SS Grade to be 316L and 1.2 mm thick. Profile to be flushed with floor level. |
| 59 | Carpet flooring - 20 oz and above |
| 60 | Supply and application of Nylon carpet tile flooring as per the specifications as mentioned below. Note that the rates to include pattern making and customisation as per flooring concepts and design enclosed for reference. |
| 61 | Size - 500 x 500 mm |
| 62 | Construction - Multilevel pattern loop pile |
| 63 | Yarn - 100% BCF Nylon 6.0 |
| 64 | Dye method - 100% solution dyed |
| 65 | Gauge - 1/12 |
| 66 | Production weight - 22 oz psy |
| 67 | Total thickness - 7.0 mm |
| 68 | Secondary Backing - Condensed Vinyl with Fibreglass Reinforcement |
| 69 | Packing - 20 pcs per box. |
| 70 | Rate to include covering of finished flooring with poly urethane sheet as a protective layer till the space is handed over. |
| 71 | Main Company logo |
| 72 | Company logo to be cut and shaped as per details enclosed, Signage to be done in acrylic backlit with LED lighting. |
| 73 | Glass ledges - 650 x 450 mm deep. |
| 74 | Supply and fixing of 12 mm thick toughened glass ledges to be fixed with ss finished D brackets and all compete. |
| 75 | Architectural films - Providing and fixing of 3M dusted crystal film on glass as per design and pattern. Rate to include shape cutting |
| 76 | Supply & fixing of 300 mm wide 12 mm thick with pvc edge banding - pre laminated sill panelling along the running length of the external glazing. |
| 77 | Mirrors -as per drg. Rate to include backing ply, fixing with 3m double side tape, laminated or polished wooden frames as reqd Basic rate for mirrors 250 per sft |
| 78 | 3mm safety walk film on ramp for providing more grip and anti skid surface on inclined spaces. |
| 79 | Providing and fixing of spot lightsupporting ply board of 6mm thick for supporting spot lights and recessed down lighters in the grid ceiling system. |
| 80 | Providing & fixing Planter box with laminate finish in various locations below double ply with round cutting near storage - 300 X 300 X 600 MM in length- To be made with 12 mm ply and laminate finish. |
| 81 | Supply and installation of Raised access flooring as per standards, height to be 200 mm with all frameworks and accessories all complete. Unitile, Flexifloor or equivalent. |
| 82 | Bare Raised Flooring |
| 83 | Providing and fixing raised floor system as per below mentioned specification |
| 84 | Vinyl top finish panels |
| 85 | Nominal size of floor panel : 600 mm x 600 mm |
| 86 | Permissible thickness : 35 mm |
| 87 | Concentrated Loads : 450 Kgs ( 1000 lbf ) with a top-surface deflection under load and a permanent set not to exceed , respectively,2.54 & 0.25 mm ( 0.10 & 0.010 inch ) according to CISCA A/F, Section I ‘’ Concentrated Loads’’ |
| 88 | Ultimate Concentrated Load: 1125 kgs (2500 lbf ) without failing according to CISCA A/F, Section II ‘’ Ultimate Loading’’ |
| 89 | Rolling Loads : 225 kgs ( 500 lbf )of the following magnitude, with a combination of local and overall deformation not to exceed1.02 mm (0.040 inch) according to CISCA A/F, Section III ‘’ Rolling Loads’’ CISCA AF Rolling Load: 10000 Passes |
| 90 | Pedestal Axial Load Test : 22 kN axial Load per pedestal, according to CISCA A/F, Section V, ‘’Pedestal Axial Load Test ’’ |
| 91 | Pedestal Over Turning Moment Test : 113 N x meters, according to CISCA A/F, Section VI, ‘’Pedestal Overturning Moment Test’’ |
| 92 | Uniformly Distributed Load (UDL) : 1350 kg/m2 with a maximum permissible deflection of not more than 1.52 mm as per definition of “Uniform load” of CISCA tested over an area of 300x300 mm square for 126 kgs load |
| 93 | Fire Rating : The Panels shall confirm to Class O & Class 1 Fire Ratings tested as per BS 476 Part 6 (Fire Propagation) & 7 (Surface spread of flame) as also ASTM E84 1998 (Flammability) and ASTM E136 (Combustibility) |
| 94 | Panels : Access Floor panel of size 600x600 mm shall be all steel welded construction, with an enclosed bottom panandtop plain sheet which are fuse welded atvariouslocationstoformapanelofanoverallthicknessof35mm.Thepanelaftercleaning,degreasing,to the panel surface and corrosion resistance. The inner empty core of the panel shall be injected with a light weight fire retardant, non combustible cementitious compound at high pressure to fill in all the crevices of the panel and ensures support of not less than 90% of the top surface area of the panel.The panel shall have located corner holes on all edges for bolting the panel to the substructure to form a rigid monolithic smooth levelled floor. |
| 95 | SUB STRUCTURE -PEDESTAL ASSEMBLY :Sub structure installed to support the panel shall be suitable to achieve a minimum finished floor height of 150 mm to a maximum of 600 mm from the existing floor level. Pedestal design shall confirm speedy assembly and removal for relocation and maintenance. The assembly shall provide easy adjustment of levelling and accurately align panels for a maximum ± 25 mm in the vertical direction. Pedestals shall support an axial load without permanent deflection and an ultimate load as laid out in System Performance requirement.The Pedestal head assembly shall consist of a 75 x 75 x 3.50 mm embossed head mechanically riveted to a100mm long ¾” Dia rolled formed stud and 2 check nuts for level adjustment and arresting vertical movement.ThePedestalBaseassemblyshallconsistof22.20mmODpipemechanicallylockedonapressforperpendicularity and then welded to a base plate of 100 x 100 x 2 mm thick with stiffening folds.The sub structure assembly shall be suitably anchored to the floor with suitable adhesiveas recommended by the consultant / manufacturer. All steel components shall be zinc electro plated. |
| 96 | There shall be grommets given to corner of tiles to suit the grid design for power / data / voice outlets. |
| 97 | The raised Access Flooring shall be as per PSA MOB PF2/S/SPUstandards. |
| 98 | 200 mm High |
| 99 | Supplying two-cup vacuum suction lifting handles suited to the Raised floor system. |
| 100 | Provide and install 75 mm dia. Heavy Guage PVC grommets with rotating cover and passage for cables in pre-cut openings. The edges of the openings to be properly polished to prevent any injuries |
| 101 | Approved make or equivalent |
| 102 | Supply and application of Vinyl rool flooring. |
| 103 | Size - 2.6mm thick x 2000 mm x 15 m long |
| 104 | Production weight - 4000 gms/sqm |
| 105 | Total thickness - 2.6mm |
| 106 | Product code - 0503 |
| 107 | Shade name - Honey - Fonteny |
| 108 | Basic rate - 125 per sft |
| 109 | Rate to include installation with welding rods |
| 110 | European classification - 34-43 |
| 111 | Fire rating(EN) - Bfl-s1 |
| 112 | Static electrical propensity <2 |
| 113 | Slip resistance wet - R9 |
| 114 | Abrasion resistance - ≤2 |
| 115 | Thermal conductivity - 0.25 |
| 116 | Special maintenance treatment - ProtecsolTM |
| 117 | Anti-bacterial activity(E.coli - S.aureus - MRSA) - > 99% inhibits growth |
| 118 | Supply and erection of acrylic marker/duster holders - 75x75x200 mm |
| 119 | Rate to include covering of finished flooring with poly urethane sheet as a protective layer till the space is handed over. |
| 120 | Supply and installation of Raised access flooring as per standards, height to be 300 mm with all frameworks and accessories all complete. Unitile, Flexifloor or equivalent. |
| 121 | Soffit panelling on wall vertical surface |
| 122 | Supply of Vicstrip (single slat/double slat) having size of 2400x600x13mm(+/- 0.5mm) thickness, backing of 12 mm PET panel with front facia of 1 mm laminate. The product use for absorption of medium and high frequency range with NRC of 0.50 direct fix. Panel Should be anti fungal as per ASTM G:21and also Non-toxic, non-irritant, and fire compliance with safety standards confirm as per BS 476 Part 6 passes (Fire Propagation) & Part 7class2 (Surface spread of flame) ,for interior applications-The product must come with EPD certificate and Declare Label.The product should be 100% make in India and OEM must have ISO CERTIFICATIONS- complying to- IGBC membershipISO 14184-2 (no formaldehyde)ISO 9001 (Quality Management System)ISO 14001 (Environmental Management System)ISO 45001 (Occupational health & safety management system) Approved Make or equivalent |
| 123 | Restroom HPL Cubicle |
| 124 | Model Type: Shower Cubicles |
| 125 | Size of Cubicles : As Per Drawing |
| 126 | Colour of HPL Boards: As Per Vendor shade card |
| 127 | Thickness of Compact Laminate : 12mm |
| 128 | Door: 600mm*1785mm |
| 129 | Shower Cubicles (Thickness 12mm, Door 600x1785, Divider Height 1820, Overall Height 1995 ) |
| 130 | SCOPE OF WORK Supply and installation of (Nylon) series cubicles of width and depth as per specifications/site drawings. |
| 131 | ITEM DESCRIPTION Made from High Pressure Laminate (HPL) compact panel manufactured as per IS:2046 and EN-438 by applying high pressure on a bunch of kraft papers impregnated with thermosetting phenolic resin and decorative papers, impregnated with thermosetting melamine resin which provide superior scratch, abrasion, heat, chemical, impact, graffiti and moisture resistance along with anti-bacterial properties. |
| 132 | DOORS All doors will be of single colour and made of 12 mm thick HPL compact panel. The doors will have chamfered edges. Each door will be supported by 3. Nylon PA - 6 made hinges affixed to the pilasters. Nylon PA - 6 made coat hook and lock set are provided with each door |
| 133 | PILASTERS All pilasters will be made of 12 mm thick HPL compact panel with chamfered edge and completed with SS made thumb-turn lock set. Aluminium made door stopper profiles with rubber linings for dampening the noise while door closing will be provided at the vertical ends of the pilasters. Pilasters will be anchored to the floor using Nylon PA - 6 made adjustable legs. The bottom gap is 150-200 mm. |
| 134 | DIVIDERS All intermediate partitions or dividers will be made of 12 mm thick HPL compact laminate panels. They are affixed with aluminium made U-channel at their ends for ultimate stability of the system. Design No. as specified by Arch./Engr. in suede finish. Size of panels to be as per drawing. |
| 135 | HARDWARE AND ACCESSORIES • Semi-spherical (Top) head frame structure for surface protection, size to be 50 x 32 x 1.6T. Corner joinery section, size to be 40 x 16.5 x 1.8T. U-Channel Wall joinery section, size to be 22 x 16 x 1.6T. Door stopper section, size to be 21 x 12.5 x 1.6T • Nylon Polyamide grade 6 adjustable pedestal footing of base minimum diameter 70 mm, giving a clearance height of min 150 mm to max 200 mm • Self closing hinges (gravity mechanism) made from nylon polyamide grade 6. Colour to be as per specifications • Round Coat hook with base diameter 53 mm made from nylon polyamide grade 6. Colour to be as per specifications • Round Door knob diameter 48 mm with thumb-recess made from Nylon polyamide grade 6. Colour to be as per specifications • Rotating thumb-turn locking system with privacy indicator locking system made from Nylon polyamide grade 6. Colour to be as per specifications • Anti-noise rubber padding • SS grade 304 screws • Anti-rotation nylon polyamide grade 6 expandable wall plugs • The work shall complete as per drawing , under supervision of engineer in-charge and company experts |
| 136 | Accessories Details : Aluminium, Nylon |
| 137 | a) Nylon Adjustable foot |
| 138 | b) Aluminium U Channel |
| 139 | c) Nylon Gravity hinges |
| 140 | d) Nylon Coat Hook |
| 141 | e) Nylon Door Knob |
| 142 | f) Nylon Thumb Turm Indicator |
| 143 | g) Aluminium Door Stopper Channel |
| 144 | h) Aluminium Top Rail |
| 145 | I)Screws, Wall Plugs & Noise Tape |
| 146 | j)Nylon Towel rail |
| 147 | Installation Charges per cubicle |
| 148 | Wall finishes |
| 149 | Providing and applying 2 (two) or more coats of paint of approved manufacturer and shade to walls, ceilings, and other similar areas at all levels, applied evenly to produce uniform even surface to approved finish including cleaning and preparing the surface, puttying with Birla putty or equivalent all as per manufacturer\"s specifications, applying a coat of approved primer, including scaffolding, wetting and curingsurface in case of applying cement paint etc., complete.(Please note that in the case of ceiling paints, painting of exposed beams shall be considered for payment, but if there is a wall underneath the beam, the paint on the beam will be payable at the wall painting rate only) |
| 150 | Application ofapproved make or equivalent Putty to wall surfaces. Putty not to be applied on those surfaces which are getting panelled. All wall surfaces to be marked for putty work and approval taken |
| 151 | Plastic emulsion painting - Supply and application ofwashable interior grade Asian or equivalent plastic emulsion paint on walls with 1coat of wall primer and 2 or more coats of plastic emulsion paint as per manufacturers\" specifications etc. all complete. All painting final coats to be done after removal of face plates of switch boards in co ordination with the electrical contractor and face plates to be fixed only after satisfactory completion of painting. |
| 152 | Same as above but for ceiling painting. |
| 153 | Enamel paint |
| 154 | P& applying satin enamel paint on walls as per manufacturer\"s specifications ( Asian paints or equivalent) |
| 155 | POP punning |
| 156 | Supply and application of POP punning to a thickness of 10-12 mm. Application after cleaning the wall surface to get a seamless finish. Application to be done as per manufacturers\" specifications etc. all complete. |
| 157 | Special texture paint |
| 158 | Supply and application of special paint from Stuhhi or Gioio with metallic or stone finish textures, Basic rate to be considered is 245inr/ sft. |
| 159 | Storages |
| 160 | Duct shutters |
| 161 | P&F laminated shutters for janitors closet made with 19mm waterproof plywood. Rate to include providing Aluminium frame all-round and at 450mm C/C vertically to avoid bend in shutter, concealed type hinges and dead lock and recessed handles and concealed tower bolts. Typical shutter width not to exceed 450 mm. |
| 162 | DB shutters/ battery rack shutters. |
| 163 | P&F laminated shutters tp conceal Elec DB\"s at various locations made with 19mm thk waterproof plywood. Rate to include providing Aluminium frame all-round and at 450mm C/C vertically to avoid bend in shutter, concealed type hinges and dead lock and recessed handles and concealed tower bolts. Typical shutter width not to exceed 450 mm. |
| 164 | Pantry /Utility counter and storage |
| 165 | Storage in pantry - 600mm depth, 900mm high with granite top - Providing and fixing in position storage made of waterproof ply with 18mm thk. polished granite top with edge as per profile in drawing. storage box construction same as item F1. Unit to have a top row of drawers and shutter storage below. Rate to include making skirting, groves, all hardware etc. all complete. Storage to have laminated finish in the internal sides and the shutters to be made with aluminium frame and G profile for handle provision, Lacquered glass of 6mm thickness to be fixed onto the aluminium frame as per standard. Shutters to be fixed with soft close hinges. Elevation area considered for quantity measurement. Laminate and glass finish to supplied as per approved sample. |
| 166 | Janitor closet with shutters |
| 167 | P&F laminated shutters at various locations made with 19mm thk waterproof plywood. Rate to include providing Aluminium frame all-round and at 450mm C/C vertically to avoid bend in shutter, concealed type hinges and dead lock and recessed handles and concealed tower bolts. Typical shutter width not to exceed 450 mm. |
| 168 | False ceiling works |
| 169 | Soffit panelling on ceiling - Suspended from true ceiling |
| 170 | Supply and fixing of 1mm (10% +/-) Polymer Based Soffit ceilings of PARE Innovations with Perforation if deemed required, of panel sizes of 340mmx 3060mm//340mm x 4000mm along with option to custom size to a maximum of 12800mm in length in approved shade, manufactured in India, made with High temperature thermal transfer technology, waterproof, fire retardant and anti-bacterial. Termite resistant, rust proof material. Panels to be installed with Aluminium/ GI sections of suitable gauge & size, subject to change according to site conditions. Panels to be installed using suitable, same shade J-Trim with dimensions 39x20x3060/4000 (all in mm) for edge profiles and Connector with dimensions 76x20x3060/4000 mm, using same shade for connecting panels, using outside corner with dimensions 61x63x3060, which can be used in +90 degree corners and inside corner having dimensions 28x76x3060 which can be used for -90 degree corners. Panels are maintenance free and with 10 years warranty for colour & finish of the panels Including trims of PARE Innovations. All material, accessories, ancillary component all as per recommendation of PARE Innovations. or equivalent |
| 171 | Refer to tender drawings for details |
| 172 | Suspended Baffle ceiling - 300 mm deep x 2400 mm long |
| 173 | Providing and fixing floating ceiling with 25mm thick synthetic wool Baffles, the ceiling to be suspended with Gripple wire as per standards from the available true ceiling as per details mentioned. The suspension depth is to be as per the details enclosed. The acoustic board to be cut to shape as shown the presentation and views enclosed. Rate to include provisions to be made for housing service like, FAS systems, lights and HVAC etc. Note that the whole area of application will be measured for this installation. Basic rate for acoustic panel to be considered is 225 inr/sft from Techno acoustic panels or equivalent. |
| 174 | Sound Absorption:Products tested by ARAINRC value: Up to 0.9 NRC |
| 175 | Composition: 100% PET |
| 176 | Panel Dimensions: 2440 mm * 1220 mm |
| 177 | Same as above but in curved profile along the vertical plane as per design and details indicated in tender drawings and presentation |
| 178 | Same as above but in curved concentric circles shapes as per design and details indicated in tender drawings and presentation |
| 179 | Same as above but with 12 mm thickness panels and in open cell gird of 150 x 150 mm c/c spacing in conference rooms and executive cabins. |
| 180 | STRETCH CEILING WITH LED BACK LIGHT |
| 181 | Stretch ceiling |
| 182 | Stretch fabric ceiling - \"Barisol-Euroceil \" or equivalent.. Rate to include supply and installation. |
| 183 | Supply and installation of demountable PVC stretch ceiling welding with harpoon ready to install |
| 184 | Fire rated to European standards b-s1-d0/b-s2-d0/B1/B2* |
| 185 | UL Classified as per standards - UL 723 |
| 186 | 10 Years warranty on membrane seam raptures & profile. All joints to be fused/provided with approximate interface trims to be able to demount the ceiling to access the lights. Lighting solution with LED, necessary drivers, accessories. The ceiling shall be installed as per details drawing using proprietary aluminium profile complete as per Manufacturer’s installation guidelines and as per approved shop drawings in line with the design intent and approval by the Architect/PM. |
| 187 | PHYSICAL PROPERTIES-Thickness -0.17mm, Weight - 220 gms/sq.m |
| 188 | MECHANICAL PROPERTIES-Breaking Strength-Lengthwise : 204Kg/Sacm (DIN-EN ISO 527-3/2/200 Standard, Widthwise : 204Kg/Sacm (DIN- EN ISO 527-3/2/200 Standard) |
| 189 | Elongation Under Tensile- Lengthwise : 140% (DIN- EN ISO 527-3/2/200 Standardi, Widthwise: 150% (DIN - EN ISO 527.3/2/200 Standard) |
| 190 | LIGHT TRANSMISSION & REFLECTION PROPERTIES OF TRANSLUCENT PVC FABRIC |
| 191 | Light Transmission 41%/EN410:20111 |
| 192 | Light Reflection 57 8% (EN410.201 11 |
| 193 | Rate to also include LED strip light from OSRAM or equivalent with 8W per Meter output with 4700 K colour temperature and minimum 5 years warranty. |
| 194 | Basic rates for Stretch ceiling and LED strip light to be 1250 per sft. |
| 195 | Rate to also include AMC for Minimum 3 years for general upkeep of the installation including the lighting. |
| 196 | Supply and fixing ofceiling panels with Rigitone false ceiling system |
| 197 | M/F Rigitone Activ’Air 8/18 Ceiling includes 20x28x30x0.5mmTM Perimeter Channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is fixed along the perimeter of existing wall with the help of HILTI HPS - 1 (6x40) impact anchor at 600mm centres. 25x10x0.5mmTM Ceiling Angle {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is suspended by fixing it to the 27x37x25x1.6mm® soffit cleat {GI(IS513)YS-260Mpa,Finish-Galvanised 120GSM(IS277)}. Soffit Cleat and® Rawl Plug- Ø8x45mm {Material-IS 513 CR1 grade, Zinc coating (7 to 8 microns) pull out load- 6.8kN for M30 concrete grade} creating 1000mm x 900mm grid. 15x45x15x0.9mmTM Intermediate channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277) fixed to the ceiling angle at every 1000mm c/c} andTMCeiling Angle is fixed at every 900mm along the length of Intermediate channel with M6 x 12mm Hex Bolt & Nut arrangement {Material–As per EN 10083 Finish – Zinc Plating} or with 2 Nos of Ø4.2x13® metal to metal screw {Material-Carbon steel EN-ISO 7049/50 Finish- Zinc Coating Thickness- 4.14micron.}. 80x26x0.5mmTMCeiling Section {Material-GI (IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is then fixed to theTM Intermediate Channel {Material-GI(IS513),YS-260Mpa, Finish-Galvanised 150GSM(IS277)} with the help of® Connecting Clip {Material -High carbon spring steel wire(BS970Gr.En42),46-48HRC,Finish-Zinc plating 4-6 micron} and in direction perpendicular to the Intermediate channel at 333mm c/c. Boarding shall start from the center of ceiling area. Single layer 12.5mm Rigitone Activ’Air 8/18 board of size 1188x1998mm having all four square edges, 15.5% perforation area of board & hole size of 8mm diameter at a c/c of 18mm; backed with acoustic tissue, having NRC values 0.55, is then screw fixed to ceiling section with 30mm Rigitone screws/25mm drywall screws {Material-Carbon steel EN-ISO 7049/50,Finish-Case hardened Grey Phosphating} at 170mm centres. For higher NRC value, Resin bonded glass wool of 24kg/M3 and 50mm thick can be placed on top of the board ( Refer Rigitone Activ’Air 8/18- PDS for the NRC values). Finally all square edges of the boards are to be jointed and finished so as to have a flush look. The joint filling using Vario joint filler and Rigitone joint filler set technique should be employed for the joint-less installation of Rigitone perforated boards with continuous Perforation. After installation and joint-filling, the boards should be primed and then painted with a short haired paint roller. Paint should not be applied using a brush or spray diffuser . Serrated steel section has effective thickness of 2T (2xdepth), better load carrying capacity, enhanced screw retention, Improved acoustic performance & fire resistance as compared to plain steel section. |
| 198 | Rate to include two coats of acrylic emulsion paint with primer as per approved sample as well. |
| 199 | M/F Suspended Plain Ceiling includes™ Perimeter Channel {Material-GI(IS513),YS-260Mpa,Finish- Galvanised 150GSM(IS27 )} is fixed along the perimeter of existing wall/ partition with the help of HILTI HPS - 1 (6x40) impact anchor, at 600mm centres.™ Ceiling Angle {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is suspended by fixing it to the® soffit cleat {GI(IS513)YS-260Mpa,Finish-Galvanised 150GSM(IS277) }. Soffit Cleat and ® Rawl Plug- Ø8x45mm {Material-IS 513 CR2 grade, Zinc coating (7 to 8 microns) pull out load- 6.8kN for M30 concrete grade} creating 1220mm x 1220mm grid.™ Intermediate channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277) } is fixed to the™ Ceiling Angle with M6 x 12mm Hex Bolt & Hex Nut arrangement {Material–As per EN 10083 Finish – Zinc Plating} or with 2 Nos of Ø4.2x13® metal to metal screw {Material-Carbon steel EN-ISO 7049/50 Finish- Zinc Coating Thickness- 4.14micron.} The™ Ceiling Section {Material -GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is then fixed to the™ Intermediate Channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} with the help of® Connecting Clip {Material-High carbon spring steel wire(BS970Gr.En42)-46-48HRC,Finish- Zinc plating 4-6 micron} and in direction perpendicular to the Intermediate channel at 457mm c/c.5. Single layer of 12.5mm tapered edge Gypboard® Plain (conforming to IS 2095-Part 1:2011, Certified board) is then screw fixed to ceiling section with 25mm drywall screws {Material-Carbon steel EN-ISO 7049/50,Finish-Case hardened Grey Phosphating} at 230mm centres on ceiling section & 150mm at periphery of ceiling. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with® Pro-Fill Jointing compound (Conforms to ASTM C475),® Joint Paper tape. Serrated section has effective thickness of 2T ( 2xdepth), better load carrying capacity, enhanced screw retention,Improved acoustic performance & fire resistance as compared to plain steel section. |
| 200 | GUIDE SPECIFICATION FOR MODULAR GRID CEILING SYSTEM |
| 201 | GRID CEILING |
| 202 | Supply and installation of modular Grid ceiling as per specifications enclosed, |
| 203 | Silhouette Grid |
| 204 | Reveal : 6mm wide in white color |
| 205 | Tile thickness - 15mm |
| 206 | Edge detail - Straightedge |
| 207 | Humidity resistance - 95% |
| 208 | NRC - 0.5 |
| 209 | Light reflectance - 90% |
| 210 | Fire performance - Class 0/Class 1 (BS 476) |
| 211 | Sound Attenuation - 30 DB |
| 212 | Ceiling Suspension System |
| 213 | Proprietary supplied ceiling suspension system to consist of 2mm or 3mm GI suspension rod/wire with adjustable butterfly clip securely affixed to structural ceiling using soffit angle fixing bracket and 10mm dia hook type anchor fastener. Ceiling suspension system to be fixed at interval (grid) of 1200mm in both directions. |
| 214 | Grid System |
| 215 | Supply of proprietary concealedGrid System to consist of Main Runners @ 600mm and joined by Cross Tees @ 600mm to form overall grid opening of 600mm x 600mm. Additional cross tees are to be placed where appropriate for light fixtures, AC diffusers. |
| 216 | The grid system used shall be hot dipped galvanised steel sections, with exposed surfaces chemically cleaned and capped prefinished in baked polyester paint |
| 217 | Lay-in Tile |
| 218 | The grid system to have shadow wall angle as per details |
| 219 | 600mm x 600mm x 15mm mineral fibre grid tile - CertainTeed- Sand Micro Tiles. |
| 220 | Same as above but with 600x600 tiles with either laminated finish or moisture resistant finish both on the rear and the front of the tiles - Gyprex® Majesty Tiles. |
| 221 | VMT Clouds - Printed suspended ceiling system |
| 222 | Supply of VMT Printed Clouds (in shape of Round/ Triangle/Hexagaon/Petal)which shall be processed with VMT technology for surface customization, colour options andpattern as per the designers requirement(from our lookbook) the Clouds shall be made from--100% polyester fiber, with up to 70% recycled fiber. Centre Thickness - 40mm (+/-1mm)Panel Should be anti fungal as per ASTM G:21and also Non-toxic, non-irritant, and fire compliancewith safety standards confirm as per BS 476 Part 6 (Fire Propagation) & Part 7 (Surface spread of flame) ,ASTM E 84 Class A, EN 13501 part 1C, S2,d0 for interior applications. Noice reduction coefficient (NRC) - varies from 0.30 to 0.60The product should be 100% make in india and OEM must have ISO CERTIFICATIONS- complying to- IGBC membershipISO 14184-2 (no formaldhyde)ISO 9001 (Quality Mangement System)ISO 14001 (Environmental Management System)ISO 45001 (Ocupational helth & safety management system) Approved make or equivalent |
| 223 | Round - 1500mmdia |
| 224 | Hexagon - 750mm one side |
| 225 | Triangular - 1500 mm one side |
| 226 | Furniture |
| 227 | Reception desk in lift lobby |
| 228 | Size : 1200 x550 x 750mm & 1050mm(H) |
| 229 | Fabricating and fixing ofa tableas per details indicated below |
| 230 | Providing and fixing of reception desk lower level formed out of 18 mm plywood with soffit pvc panelling for front and side cladding as indicated in the table view and all verticals and side panels to be of the same.All connections and inserts to be carpentered as per details and complete in all aspects.Top to have laminate finish as indicated in the view. |
| 231 | The table shall have suspended CPU stand as per details and approval. |
| 232 | Soft seating - Supply & Fixing of upholstered sofa seater as per requirements with high density Memory foam and leatherette upholstery as per approved sample. Frame work to be made with sold wood frame. |
| 233 | Single seater |
| 234 | L-shaped sofa of size - 2.65 m x 2 m as indicated in the plan. |
| 235 | Supply and fixing of coffee/ side / centre table as per requirements |
| 236 | Size - 450 x 450 mm |
| 237 | Size - 900 x 450 mm |
| 238 | Civil and related works |
| 239 | FLOORING AND CLADDING WORKS |
| 240 | Note: |
| 241 | Rates quoted in the following items shall include cost of all surface/substrate preparation, base plaster coat in the case of wall cladding/dado works, protection of flooring by providing a polythene sheet and a layer of POP.Rates to including carrying out works on all levels and heights, cartage, wastage etc. |
| 242 | Basic rates shall be the cost of material at suppliers place without taxes. Taxes, wastage up to 10%, carting, transport to site, labour for unloading, stacking, laying, cleaning and grouting etc all complete of the following items is to be taken by the contractor and added to basic price for quoting overall rate. |
| 243 | Providing and applying sample for approval to be carried out site level at no extra cost |
| 244 | I) Granite - Rs. 3000 per sqm |
| 245 | II) Ceramic tiles - flooring - Rs. 550 / sqm |
| 246 | iii) Ceramic tiles dado - Rs. 650 /sqm |
| 247 | iv) Vitrified tiles - Rs. 850 /sqm |
| 248 | v) Marble- Rs. 6500 /sqm |
| 249 | A maximum of - or + 5% variation is acceptable in basic rates indicated above. |
| 250 | Granite Stone on Counters |
| 251 | Providing and laying 3/4\" thick Granite Stone Slabs on counters, shelves, sills, and facias, laid on a 3/4\" thick bed of 1:4 Cement Mortar (1 Cement : 4 Coarse Sand), jointed with cement slurry mixed with pigment to match the shade of granite including mirror polishing, rounding off edges, edge-polishing etc. (Allow necessary cut-outs for fixing wash basin, pipes, waste couplings etc.) |
| 252 | Providing and laying in floors 20 mm thick pre-polished granite slabs over a bed of 40mm - 50 mm thick bedding mortar 1:4 (1 cement : 4 coarse sand) jointed with white cement slurry mixed with pigments as per approved colour. |
| 253 | Same as above but in skirting, risers and dado. Rate to include 6 mm edge chamfering wherever desired |
| 254 | Same as above but in treads etc. Rate to include half round nosing, edge polishing, making grooves as desired |
| 255 | Extra over as item \"a\" and \"c\" but with \"leather\" finished granite. |
| 256 | Vitrified tile flooring- laticrete grout |
| 257 | Same as item no 1.2 but for vitrified tile flooring of size 600 x 600 mm, 12 mm thickness anti-skid tiles |
| 258 | Same as item no 1.2 but for vitrified tile flooring of size 600 x 600 mm, 15 mm thickness anti-skid external grade full body tiles |
| 259 | Same as item 1.3 but for vitrified tile wall cladding of min size 300 x 600 mm, 12mm thickness |
| 260 | Demolition of existing walls |
| 261 | Demolition of existing walls on existing 6th floor - Rate to include demolition w/o any damage to any other other item and existing floor. Rate also to include carting away the debris to GF and to some other location as approved by us . Debris to be cleared from GF on the same day. |
| 262 | Core cutting to be done for waste water pipes. |
| 263 | 100 Dia core cutting to be carried out in the site based on the location of the waste water drain outlets. The location to be marked and approval to be sought from the base builder prior to the commencement of the process of core cutting- Hilti core cutting system or equivalent |
| 264 | General design specifications and precautions Location and scanning: Before any cutting, use a ground penetrating radar (GPR) or a cover meter to precisely locate all embedded elements, including reinforcing bars, post-tensioning cables, and electrical conduits. Cutting post-tensioning cables is extremely dangerous and can cause catastrophic structural failure.Avoid critical areas: Core cuts should be avoided in high-stress zones of structural elements, such as:Beams: Do not cut cores through beams.Columns: Never core-cut through structural columns.Near supports: Avoid drilling close to beam-column joints, column-slab junctions, or other support locations, as these are subject to high shear forces.Size limitations:The diameter of the core cut should be as small as possible.A common standard for coring for strength testing requires the core diameter to be at least three times the maximum size of the concrete aggregate.Structural analysis: A structural engineer must perform an analysis to confirm that the integrity of the wall or slab will not be compromised by the proposed opening. The analysis should consider the hole\"s size, location, and proximity to other openings. Specific guidelines for walls Load-bearing walls: Cutting cores in load-bearing walls is especially critical and may require a review of the entire wall\"s load-carrying capacity. Reinforcing the wall may be necessary.Shear walls: Core cutting in shear walls, which are designed to resist lateral forces from wind or earthquakes, is highly discouraged. A structural engineer must be consulted for any modifications to these elements.Rebar clearance: The core must be drilled to avoid all reinforcing steel. If a rebar is inadvertently cut, a structural engineer must be notified immediately to design a repair or reinforcement solution. Specific guidelines for slabs Slab thickness: Consider the slab\"s thickness in relation to the core diameter. A deep, large-diameter core cut can significantly reduce the slab\"s flexural capacity.Pre-stressed/post-tensioned slabs: It is extremely hazardous to core-cut into a pre-stressed or post-tensioned slab without expert supervision. Damage to tendons can cause the structure to fail.Multiple holes: If multiple cores are required, they must be spaced far enough apart to prevent a reduction in the concrete\"s strength between them. A structural engineer should approve the spacing.Mid-span vs. supports: When core cutting is necessary, it is generally safer to make the cut at the centre of the slab, away from the support areas where bending moments and shear forces are typically highest. Repair and reinstatement Fill materials: After the core cut is completed, the hole must be filled with a non-shrinkage, high-strength grout or concrete. A bonding agent is often applied before filling to ensure a strong connection with the existing concrete.Surface preparation: Before filling, clean and roughen the surfaces of the core hole to ensure a good bond.Reinforcement replacement: If a rebar was cut, additional reinforcing may be required, such as bonding steel plates or using fiber-reinforced polymer (FRP) wraps, following the engineer\"s specifications.Preventing moisture intrusion: Proper repair is essential to prevent moisture from entering the concrete and causing corrosion of the rebars. |
| 265 | Aerocon panel- 75mm thick, A sandwich panel of two fiber-reinforced cement sheets enclosing a light weight concrete core composed of Portland cement and Fly-ashFully cured at factory, with a Unique “Tongue and Groove” jointing system. Rate to include patty and two coats of acrylic emulsion paint finish as per approved shade. Rate to include basic MS structure anchor bolts, scaffolding and erection. Rate to also include MS frame work around doors, windows and wall openings for services etc. |
| 266 | Materials & CompositionFace Sheets: Two layers of fiber-reinforced cement sheets. Core: Lightweight concrete made from Portland cement, binders, fly ash, fibers, and mineral aggregates. Key SpecificationsThickness: Available in standard thicknesses -75mm. Dimensions:Width: Typically 600mm. Height: 2.4mWeight: Around 58 kg/sqm, depending on the thickness. Thermal Conductivity: Around 0.17-0.22 W/mK. Axial Load/Meter Width: Can support loads of approximately 55-85 KN/m. Performance & FeaturesFire Resistance: Certified for fire resistance, providing a significant safety rating. Thermal & Acoustic Insulation: Offers good sound and thermal insulation properties. Water & Termite Resistance: Provides excellent resistance to water and termites. Dry Wall System: Designed for dry wall partition construction, eliminating the need for wet trades. Eco-Friendly: Made with recyclable materials and considered a green building material. Quick Installation: The interlocking tongue and groove system allows for fast and easy installation. Long Lifespan: Properly installed panels can last for over 50 years. |
| 267 | Plastering |
| 268 | Plasters to be prepared with Cement Mortars only with specified composition of cement and sand. Rates to include application on all type of surfaces, at all levels. Allow for p&f galvanized chicken mesh, min. 300mm wide, 24 SWG, 12mm size at junctions of brick and concrete members. Mesh to be properly stretched and nailed ensuring equal thickness of plaster on both sides of the mesh.No separate payment shall be made for providing and fixing chicken mesh. Make sufficient allowances for preparation of surface, providing necessary plaster grooves, making adequate keys, making drip-moulds to design etc., complete. Rate to include scaffolding for plastering up to 4 m height from the nearest slab level |
| 269 | Plastering - On walls and ceiling. Rate to include any surface preparation etc. all complete. |
| 270 | Providing and laying ½\"-3/4\" thick plaster of 1:4 Cement Mortar (1 Cement : 4 Fine Sand) on all internal vertical surfaces and wherever specified. For surfaces requiring thick plastering (like the uneven side of 4½\" thick brick masonry wall) , a preliminary coat may be applied of suitable thickness, allowed to set about 6 hours before application of the final coat. |
| 271 | Waterproofing of RCC slabs |
| 272 | Providing and applying Chemical waterproofing treatment using Sika Plastocrete or equivalent system in areas where toilets and other wet areas are being created. Rate to include dismantling existing screed/ flooring, surface preparation of mother slab, laying fresh screed to create slope, applying waterproofing system as per manufacturer\"s specifications and preparing the surface to received floor finish. Rate to include pond testing and making good any damages if leaks are found. - As per Architects approved make and Method statement for the works shall be submitted/ obtain approval prior to commencement of works. |
| 273 | Concrete screed flooring 75mm thick |
| 274 | Providing and laying 75mm thick 1:2:4 Cement Concrete (Indian Patent Stone with 1 Cement : 2 Coarse Sand : 4 graded stone aggregate of 20 mm and down gauge) laid in two layers, under layer of 40mm thick cement concrete 1:2:4 and top layer with 12mm thick with metallic concrete hardener of approved quality mixed in the ratio as specified by the manufacturer. Rate to include providing slope as desired, finishing smooth, curing 7days, watering, cleaning etc. complete. Hand held power trowel to be used for levelling. |
| 275 | MASONRY WORK & PLASTER |
| 276 | Brickwork in Superstructure |
| 277 | Brickwork of 9\" thickness |
| 278 | Providing and laying brick masonry above plinth for superstructure, for walls, pillars, parapet, cabins, architectural elements and other similar locations etc., in 1:6 Cement Mortar (1 Cement : 6 Coarse Sand by volume) in true line, level and plumb, including raking the joints up to 20 mm depth, rubbing and cleaning the surface, with necessary scaffolding, curing,soaking & the bricks adequately before construction, complete as directed and specified. Well burnt 1st class table moulded, good quality approved bricks |
| 279 | Exposed brickwork 9\" thick |
| 280 | Half brick partition walls |
| 281 | Providing and laying 4½\" thick half brickwork in partition walls,fins, parapets, architectural elements etc., with well burnt 1st class table moulded, good quality approved bricks in 1:4 Cement Mortar (1 Cement : 4 Coarse Sand by volume) including providing 2 Nos., 6 mm Dia.,FE 500 MS ribbed bars at every 4th course, including soaking the bricks in water adequately and drying, scaffolding, curing, rubbing the surface, raking out the joints etc., complete as directed and specified for walls, parapet, platform supports etc., at all floor levels. |
| 282 | Rcc counters for wash basins & benches |
| 283 | 100 MM thick M25 Grade RCC counter with single matt 8 - 10 Dia steel reinforcement FE 500 to be cast at site as per sizes indicated in the drawings. 4½\" Brick wall under counter support to be considered. Quantity will be covered in item 12c. Providing, installing and de-shuttering Formwork with ordinary finish with plywood / steel for all in-situ concrete members as per technical specifications including strutting, staging, propping, supports, bracings, scaffolding single stage or multistage for locations and levels. Minimum 7 days of curing time to be considered. |
| 284 | Pergola covered structure for outdoor canteen in open terrace. |
| 285 | The glass skylight shall consist of a 13.52 mm thick laminated glass panel system, comprising 6 mm thick clear toughened glass + 1.52 mm PVB interlayer + 6 mm thick clear toughened glass, supported on a mild steel (MS) structural framework integrated with a pergola system and finished with powder coating. The MS structural framework shall be fabricated using 75x100x3 mm thick box sections for secondary members and 200x200 mm box sections for columns or as per structural design. The entire MS structure shall be fabricated and assembled at site, and fixed to the RCC slab or beam using base plates, anchor bolts, and neoprene isolation pads to allow for thermal expansion and minimize corrosion risk. All MS sections shall be treated with one coat of zinc-rich epoxy primer (minimum 40 microns DFT), followed by two coats of PU paint (minimum 100 microns total DFT), or hot-dip galvanized if exposed. The glass panels shall be secured using a two-way aluminium pressure plate glazing system, with all joints sealed using structural silicone and EPDM flashings to ensure weatherproofing. The skylight shall be installed at a minimum slope of 5 degrees to ensure proper drainage, with integrated aluminium perimeter flashings and a concealed gutter system provided to prevent water ingress and manage runoff. The entire system shall be designed to withstand wind and live loads in accordance with IS 875, with structural deflection limited to L/175 or less. All materials and workmanship shall conform to relevant Indian Standards, including IS 2062 for steel, IS 2553 for safety glass, and IS 16231 for structural glazing systems. |
| 286 | Rate to include access ladder as per safety standards to the top side of the pergola structure. Hook arrangement to be provided for locking it into the framework for secure access to the surface.Ladder to be provided with harness anchorage system. |
| 287 | Metal puff infill panel |
| 288 | 50 mm thick partition- Metal sandwich panels with PU Foam insulation - Roof infill panels |
| 289 | TECHNICAL SPECIFICATION OF DOUBLE SKIN FACTORY INSULATED PUF PANEL |
| 290 | MONOWALL 50mm from Metecno make or equivalent. |
| 291 | External steel in 0.5mm thick (TCT) PPGI Z120GSM, 280-330 Mpa, groove in 2.5mm depth spaced at 62.5mm internval.External coating in RMP and External colour in RAL9002 shadeCore Insulation in CFC / HCFC[ ZERO ODP] Free PUF, Density 40+2 Internal steel in 0.5mm thick (TCT) PPGI Z 120GSM, 280-330 Mpa, groove in 2.5mm depth spaced at 62.5mm internval.External coating in RMP and External colour in RAL9002 spaced at 62.5mm internval.External coating in RMP and External colour in RAL9002 shadeEffective cover width of the panel will be 1000mmThickness of the panel 50+2mmThermal Transmittance [ U ] : 0.41Watt / m2 0CThermal Resistance [R] : 2.44 m2 0C / Watt |
| 292 | Rate to include erection, scaffolding, necessary supports above false ceiling and from the true ceiling, applying sealant in all the joints and at junctions. |
| 293 | Supply and installation of out door grade PVC Garden Lattice Plastic (PVC, HDPE) Standard Panel Size: 4 ft. x 8 ft.Thickness: Often 5mmMaterial: Polyvinyl chloride (PVC) or High-Density Polyethylene (HDPE)Durability: Weather-proof, resistant to rot, rust, and warping; can last for yearsColores: Green, white, red, ivory, blueMaintenance: No painting required |
| 294 | Rate to include fixing along the bottomportion of the metal pergola with appropriate framework as per standards. |
| 295 | Same as above but to be erected along the vertical surface along with MS framework of 50 x 50 mm MS channels as an enclosure for the A/C outdoor units to be installed in the terrace level. Height of the panels to be 1800 mm highOpenable panel to be provided for access into the internal unit space. |
| 296 | Anti Bird Nets for BalconiesSupply & installation of Anti bird nets made of 2.5mm thick nylon, providing strong protection against birds while ensuring visibility and airflow. Ideal for urban settings, To be installed on to the metal pergola structure with appropriate fasteners and anchors as per standards. |
| 297 | Carrying out necessary rectification works in existing walls, floors, and ceilings to enable further works. Includes patching, levelling, trimming, minor plaster repair, crack filling, surface preparation, and other small civil touch-ups as required for smooth execution of subsequent works. All complete as directed by Engineer-in-Charge. |
| 298 | TERRARIUM BOQ |
| 299 | Ultra clear - Toughened Glass |
| 300 | An ultra-clear terrarium tank with a door offers crystal-clear visibility and easy access for maintenance. Made from high-transparency glass, it enhances the natural beauty of plants and décor while the built-in door allows convenient care and ventilation, creating a perfect environment for a thriving ecosystem. (16x3x7 feet) |
| 301 | Exhaust Fan, Blower& Grunfos Pump |
| 302 | Wooden work with Granite Base |
| 303 | Horti Grade Grow Light-35W |
| 304 | Boost plant growth with our Full Spectrum Grow Light, designed to mimic natural sunlight. Perfect for terrariums, and indoor gardens, it enhances photosynthesis, promoting healthier, more vibrant plants. Energy-efficient, durable, and ideal for all growth stages. |
| 305 | Automated Sprinkler + Drip system |
| 306 | An automated sprinkler and drip system in a riparium ensures precise and efficient watering by combining fine misting for humidity control with targeted drip irrigation for plant roots. This system maintains optimal moisture levels, reduces manual effort, and promotes a healthy, self-sustaining ecosystem. |
| 307 | Stump wood and Detailing Wood |
| 308 | Stump wood is a natural hardscape element used in terrariums to create realistic, forest-like environments. It provides surfaces for plant attachment, enhances the aesthetic appeal while contributing to the ecosystem’s biological balance. |
| 309 | Horti Grade Harscape Materials |
| 310 | Horti-grade expanding foam is a plant-safe, waterproof foam used for creating naturalistic backgrounds and structural support in ripariums and terrariums. It securely holds plants, rocks, and driftwood while promoting moss and epiphyte growth, enhancing both aesthetics and ecosystem stability. |
| 311 | Natural Detailing Rock |
| 312 | Enhance your riparium with natural, mineral-rich rocks. These rocks help maintain stable water parameters by providing essential minerals and a natural habitat for fish and invertebrates. Durable, aesthetically pleasing, and safe for aquatic life. |
| 313 | Pasting Kit (Cable Tie, Cyanoacyrlate Glue , Garden Tape) |
| 314 | Ensure secure and durable bonding with our pasting kit, specially designed for aquariums and terrariums. Ideal for assembling glass, acrylic, or hardscape elements, it provides a strong, waterproof seal. Easy to use, long-lasting, and safe for aquatic environments. |
| 315 | Terrarium Soil |
| 316 | Terrarium soil is a well-draining, nutrient-rich substrate designed to support plant growth in enclosed ecosystems. It typically consists of organic matter, charcoal, and aerating materials like sand or perlite, ensuring proper moisture retention, root health, and long-term sustainability for terrarium plants. |
| 317 | Exotic Rainforest Plants |
| 318 | Exotic rainforest plants bring lush, vibrant greenery to ripariums and terrariums, mimicking natural jungle ecosystems. These plants, including bromeliads, orchids, ferns, and anthuriums, thrive in high humidity and indirect light, adding rich textures, colours, and biodiversity to the environment. Includes Miniature trees |
| 319 | Live Moss |
| 320 | Natural Forest Vibe: Moss creates a lush, green carpet that mimics the look of a forest floor, enhancing the immersive feel of the terrariumHumidity Regulation: Moss retains moisture, helping to maintain high humidity levels essential for a terrarium. |
| 321 | Sphagnum Moss & Moss media |
| 322 | Lava chips are lightweight, porous volcanic rocks used in terrarium for filtration, drainage, and aesthetics. Their porous structure promotes beneficial bacteria growth, improves water circulation, and enhances substrate aeration, supporting a healthy and balanced ecosystem. |
| 323 | Drainage Layer Leca Balls + Felt |
| 324 | A drainage layer with LECA balls and felt is essential for maintaining proper moisture levels in terrariums. LECA (Lightweight Expanded Clay Aggregate) provides aeration and prevents waterlogging, while the felt layer acts as a barrier, keeping soil separate from the drainage layer to ensure healthy root growth and a balanced ecosystem. |
| 325 | Drain cell |
| 326 | Drain cells 5mm promote root circulation and prevent root damage, also used for drainage purpose |
| 327 | Fertilizers |
| 328 | Components of a Starter Pack Fertilizer Kit1. Macro-Nutrients2. Micro-Nutrients3. Worm Castings4. Moss-Specific Fertilizer5. Epiphyte Fertilizer6. Substrate Enhancers |
| 329 | Maintenance Kit |
| 330 | Includes essential tools and consumables required for routine upkeep, cleaning, and minor adjustments to ensure the system remains in optimal working condition. |
| 331 | 3D Printing, Designing, Painting & Installation |
| 332 | Including all materials, labour, tools, and incidental charges complete. |
| 333 | Installation Labour |
| 334 | Charges for skilled and unskilled labour for positioning, assembling, and complete installation at site, including all tools and tackles |
| 335 | Transport |
| 336 | Cost of safe handling, packing, loading, unloading, and delivery of all materials to site, including all charges, labour, and incidental expenses complete. |
| 337 | Design & Installation |
| 338 | Including concept development, drawings, detailing, labour, materials, supervision, and complete implementation at site. |
| 339 | Supply and fixing of base box to conceal and support the complete setup of the terrarium unit. Boxing to be done with BWR grade water proof plywood of 19 mm thickness and aluminium framework of 50x 50 mm sections for internal support. |
| 340 | Storage in pantry - 600mm high, 900mm deep with granite top - Providing and fixing in position storage made of waterproof ply with 20mm thk. polished granite top with edge as per profile in drawing. storage box construction same as item F1.. Elevation area considered for quantity measurement. |
| 341 | BOQ 9 - MODULAR |
| 342 | LINEARE WORKSTATION: 1200 X 550 X 745 HT |
| 343 | L-SHAPE WORKSTATION: 1350/1350 X 600 X 745 HT |
| 344 | System : League Plus or equivalentTable top : 25mm thick Prelaminated Particle Board confirming to IS12823:1990 with Flat PVC edge band. All the edges and exposed surface shall be edge banded with PVC lipping (color to be matched with the laminate).Understructure: Metal Leg with 1.6 mm thick CRCA sheet, 40x40 mm Square MS pipe with M10 leveller at the ends . Legs shall be fitted to the ground with M10 screw leveller with the height adjustment up to 12mm to 15mm. Cross member are made of 50mm x 25mm x 1.2mm MS sections with powder coated finish confirming to IS 13871:1993. Cross members shall be mounted by end brackets. Cross member end bracket shall be made of 3mm thick IS 513: 2008 CRCA sheet with powder coated finish up 40 to 60 Micron DFT.Leg Modesty : 0.8mm thick CRCA sheet, 450mm Height with powder coated finish and Perforation at 400mm Ht. Understructure design is robust and very Sturdy enough with required neccessary Brackets.Modesty : modesty made up of CRCA 0.8mm sheet with double bend on all sides and for back to back workstation modesty made up of CRCA 0.8mm thick confirming to IS 513: 2008 with powder coated finish up 40 to 60 Micron at 300mm Ht.Main Privacy Screen : 18mm thick Partition considering the features of Magnetic & Fabric of 455mm Height feasibility. 18mm raw particle board. Complete screen periphery is covered by 22mm thick aluminum extrusion (6063-T6) Frame powder coatedfinished in 40 to 60 micron. Aluminium privacy panel section is constructional member of understructure shall be made of Aluminium extrusion confirming the IS 733:1983.Screen is supported by GI Stud which will be mounted on Aluminum section. Screen height will be 455mm above work-top, length will be 150mm less than work-top length. Wire Management: Electrical wires shall be carried from vertical duct or Electrical Legs from floor. Horizontally wire shall float in 105x130 mm cable tray for one sided workstation and 220x130mm cable tray for back to back workstation. Cable tray shall be made of 0.8mm CRCA sheet confirming to IS 513:2008. Horizontal 1 Tier Triangular Cable tray (wire carriers) are made of CRCA & fixed to the understructure below worktop with specially designed brackets. Cable tray will be provided with separation tray for electrical and data wires. Provision for fixing Switch plates are provided in the cable tray for easy access through Aluminium Powder coated Access Flap with soft Closing mechanism of 450mm Lx145mm D. Switches to be mounted on Cable Tray Angular Surface for Easy use. |
| 345 | PRELAM PEDESTAL : 400 X 450 X 621 HT |
| 346 | PRELAM 3 DRAWER (2B+1F) PEDESTAL UNIT 400Wx450Dx621H (With Castor) - madeup of 18mm thick Prelaminated Particle Board with PVC Edge band finish and the telescopic slides for mobility of drawers and filers. The drawer is made up of 18 mm thick PPB.Centre Locking Mechanism considered. Side Finger Groove Handle is considered for Seamless Look.-- MS & CRCA sheet items are to be sourced from TATA/Jindalor equivalent |
| 347 | Cabin table : 1800 x 600 x 745ht, SIDE STOARGE : 950 X 450 X 750 HT |
| 348 | System : League plusor equivalentTable top : 25mm thick Prelaminated Particle Board confirming to IS12823:1990 with Flat PVC edge band. All the edges and exposed surface shall be edge banded with PVC lipping (color to be matched with the laminate).Understructure : Metal Leg with 1.6 mm thick CRCA sheet, 40x40 mm Square MS pipe with M10 leveller at the ends . Legs shall be fitted to the ground with M10 screw leveller with the height adjustment up to 12mm to 15mm. Cross member are made of 50mm x 25mm x 1.2mm MS sections with powder coated finish confirming to IS 13871:1993. Cross members shall be mounted by end brackets. Cross member end bracket shall be made of 3mm thick IS 513: 2008 CRCA sheet with powder coated finish up 40 to 60 Micron DFT.Leg Modesty : 0.8mm thick CRCA sheet, 450mm Height with powder coated finish and Perforation at 400mm Ht. Understructure design is robust and very Sturdy enough with required neccessary Brackets.Modesty : modesty made up of CRCA 0.8mm sheet with double bend on all sides and for back to back workstation modesty made up of CRCA 0.8mm thick confirming to IS 513: 2008 with powder coated finish up 40 to 60 Micron at 300mm Ht.Wire Management: Electrical wires shall be carried from vertical duct from floor. Vertical Diuct will be provided with separation tray for electrical and data wires. Provision for fixing Switch plates are provided in the cable tray for easy access through Aluminium Powder coated Access Flap with soft Closing mechanism of 450mm Lx145mm D. Switches to be mounted on Cable Tray Angular Surface for Easy use.STORAGE UNITSTOP :18mm thick Prelaminated Particle Board confirming to IS12823:1990 with Flat PVC edge band. All the edges and exposed surface shall be edge banded with PVC lipping (color to be matched with the laminate).CARCASS & SHUTTER : 18mm thick prelaminated board with PVC Edge band with openable ShutterBACK: 18mm thick prelaminated board with PVC Edge band.LOCK : Regular lock Chamfer handles. |
| 349 | Cabin table : 1800 x 600 x 745ht, SIDE STOARGE : 950 X 450 X 750 HT |
| 350 | System : League plusor equivalentTable top : 25mm thick Prelaminated Particle Board confirming to IS12823:1990 with Flat PVC edge band. All the edges and exposed surface shall be edge banded with PVC lipping (color to be matched with the laminate).Understructure : Metal Leg with 1.6 mm thick CRCA sheet, 40x40 mm Square MS pipe with M10 leveller at the ends . Legs shall be fitted to the ground with M10 screw leveller with the height adjustment up to 12mm to 15mm. Cross member are made of 50mm x 25mm x 1.2mm MS sections with powder coated finish confirming to IS 13871:1993. Cross members shall be mounted by end brackets. Cross member end bracket shall be made of 3mm thick IS 513: 2008 CRCA sheet with powder coated finish up 40 to 60 Micron DFT.Leg Modesty : 0.8mm thick CRCA sheet, 450mm Height with powder coated finish and Perforation at 400mm Ht. Understructure design is robust and very Sturdy enough with required neccessary Brackets.Modesty : modesty made up of CRCA 0.8mm sheet with double bend on all sides and for back to back workstation modesty made up of CRCA 0.8mm thick confirming to IS 513: 2008 with powder coated finish up 40 to 60 Micron at 300mm Ht.Wire Management: Electrical wires shall be carried from vertical duct from floor. Vertical Diuct will be provided with separation tray for electrical and data wires. Provision for fixing Switch plates are provided in the cable tray for easy access through Aluminium Powder coated Access Flap with soft Closing mechanism of 450mm Lx145mm D. Switches to be mounted on Cable Tray Angular Surface for Easy use.STORAGE UNITSTOP :18mm thick Prelaminated Particle Board confirming to IS12823:1990 with Flat PVC edge band. All the edges and exposed surface shall be edge banded with PVC lipping (color to be matched with the laminate).CARCASS & SHUTTER : 18mm thick prelaminated board with PVC Edge band with openable ShutterBACK: 18mm thick prelaminated board with PVC Edge band.LOCK : Regular lock Chamfer handles. |
| 351 | CAFÉ TABLE : 2400 X 800 X 750 HT |
| 352 | CAFÉ TABLE : 4200 X 900 X 750 HT |
| 353 | CAFE TABLE ;System : Cafe tableTabletop: 25mm thick Post-laminated Particle Board confirming to IS12823:1990 with Flat PVC edge band. All the edges and exposed surface shall be edge banded with PVC lipping (color to be matched with the laminate).Leg : Metal powder coated spider legs - MS pipe with M10 leveller at the ends . Legs shall be fitted to the ground with M10 screw leveller with the height adjustment up to 12mm to 15mm. Cross member are made of 50mm x 25mm x 1.2mm MS sections with powder coated finish confirming to IS 13871:1993. Cross members shall be mounted by end brackets. Cross member end bracket shall be made of 3mm thick IS 513: 2008 CRCA sheet with powder coated finish up 40 to 60 Micron DFT. |
| 354 | ROUND DISCUSSION TABLE : 1200 DIA X 750 HT |
| 355 | ROUND DISCUSSION TABLE : 1500 DIA X 750 HT |
| 356 | System : League plusor equivalentTabletop: 25mm thick Prelaminated Particle Board confirming to IS12823:1990 with Flat PVC edge band. All the edges and exposed surface shall be edge banded with PVC lipping (color to be matched with the laminate).Leg : Metal Powder Coated curve Leg - MS pipe with M10 leveller at the ends . Legs shall be fitted to the ground with M10 screw leveller with the height adjustment up to 12mm to 15mm. Cross member are made of 50mm x 25mm x 1.2mm MS sections with powder coated finish confirming to IS 13871:1993. Cross members shall be mounted by end brackets. Cross member end bracket shall be made of 3mm thick IS 513: 2008 CRCA sheet with powder coated finish up 40 to 60 Micron DFT.Wire Management: Electrical wires shall be carried from vertical duct from floor. Vertical Diuct will be provided with separation tray for electrical and data wires. Provision for fixing Switch plates are provided in the cable tray for easy access through Aluminium Powder coated Access Flap with soft Closing mechanism of 450mm Lx145mm D. Switches to be mounted on Cable Tray Angular Surface for Easy use. |
| 357 | MEETING TABLE : 1200 X 750 X 745HT |
| 358 | System : League plusor equivalentTabletop: 25mm thick Prelaminated Particle Board confirming to IS12823:1990 with Flat PVC edge band. All the edges and exposed surface shall be edge banded with PVC lipping (color to be matched with the laminate).Leg : Metal Leg with 1.6 mm thick CRCA sheet, 40x40 mm Square MS pipe with M10 leveller at the ends . Legs shall be fitted to the ground with M10 screw leveller with the height adjustment up to 12mm to 15mm. Cross member are made of 50mm x 25mm x 1.2mm MS sections with powder coated finish confirming to IS 13871:1993. Cross members shall be mounted by end brackets. Cross member end bracket shall be made of 3mm thick IS 513: 2008 CRCA sheet with powder coated finish up 40 to 60 Micron DFT.Wire Management: Electrical wires shall be carried from vertical duct or Electrical Legs from floor. Horizontally wire shall float in 105x130 mm cable tray for one sided workstation and 220x130mm cable tray for back to back workstation. Cable tray shall be made of 0.8mm CRCA sheet confirming to IS 513:2008. Horizontal 1 Tier Triangular Cable tray (wire carriers) are made of CRCA & fixed to the understructure below worktop with specially designed brackets. Cable tray will be provided with separation tray for electrical and data wires. Provision for fixing Switch plates are provided in the cable tray for easy access through Aluminium Powder coated Access Flap with soft Closing mechanism of 450mm Lx145mm D. Switches to be mounted on Cable Tray Angular Surface for Easy use. |
| 359 | MEETING TABLE : 1350X 750 X 745HT |
| 360 | System : League plusTabletop: 25mm thick Prelaminated Particle Board confirming to IS12823:1990 with Flat PVC edge band. All the edges and exposed surface shall be edge banded with PVC lipping (color to be matched with the laminate).Leg : Metal Leg with 1.6 mm thick CRCA sheet, 40x40 mm Square MS pipe with M10 leveller at the ends . Legs shall be fitted to the ground with M10 screw leveller with the height adjustment up to 12mm to 15mm. Cross member are made of 50mm x 25mm x 1.2mm MS sections with powder coated finish confirming to IS 13871:1993. Cross members shall be mounted by end brackets. Cross member end bracket shall be made of 3mm thick IS 513: 2008 CRCA sheet with powder coated finish up 40 to 60 Micron DFT.Wire Management: Electrical wires shall be carried from vertical duct or Electrical Legs from floor. Horizontally wire shall float in 105x130 mm cable tray for one sided workstation and 220x130mm cable tray for back to back workstation. Cable tray shall be made of 0.8mm CRCA sheet confirming to IS 513:2008. Horizontal 1 Tier Triangular Cable tray (wire carriers) are made of CRCA & fixed to the understructure below worktop with specially designed brackets. Cable tray will be provided with separation tray for electrical and data wires. Provision for fixing Switch plates are provided in the cable tray for easy access through Aluminium Powder coated Access Flap with soft Closing mechanism of 450mm Lx145mm D. Switches to be mounted on Cable Tray Angular Surface for Easy use. |
| 361 | MEETING TABLE : 3000 X 1200 X 745HT |
| 362 | System : League plusor equivalentTabletop: 25mm thick Prelaminated Particle Board confirming to IS12823:1990 with Flat PVC edge band. All the edges and exposed surface shall be edge banded with PVC lipping (color to be matched with the laminate).Leg : Metal Leg with 1.6 mm thick CRCA sheet, 40x40 mm Square MS pipe with M10 leveller at the ends . Legs shall be fitted to the ground with M10 screw leveller with the height adjustment up to 12mm to 15mm. Cross member are made of 50mm x 25mm x 1.2mm MS sections with powder coated finish confirming to IS 13871:1993. Cross members shall be mounted by end brackets. Cross member end bracket shall be made of 3mm thick IS 513: 2008 CRCA sheet with powder coated finish up 40 to 60 Micron DFT.Wire Management: Electrical wires shall be carried from vertical duct or Electrical Legs from floor. Horizontally wire shall float in 105x130 mm cable tray for one sided workstation and 220x130mm cable tray for back to back workstation. Cable tray shall be made of 0.8mm CRCA sheet confirming to IS 513:2008. Horizontal 1 Tier Triangular Cable tray (wire carriers) are made of CRCA & fixed to the understructure below worktop with specially designed brackets. Cable tray will be provided with separation tray for electrical and data wires. Provision for fixing Switch plates are provided in the cable tray for easy access through Aluminium Powder coated Access Flap with soft Closing mechanism of 450mm Lx145mm D. Switches to be mounted on Cable Tray Angular Surface for Easy use. |
| 363 | EXECUTIVE CABIN TABLE : 2000 X 900 X 745HT |
| 364 | System : League plusor equivalentTabletop: 25mm thick Prelaminated Particle Board confirming to IS12823:1990 with Flat PVC edge band. All the edges and exposed surface shall be edge banded with PVC lipping (color to be matched with the laminate).Leg : Metal Leg with 1.6 mm thick CRCA sheet, 40x40 mm Square MS pipe with M10 leveller at the ends . Legs shall be fitted to the ground with M10 screw leveller with the height adjustment up to 12mm to 15mm. Cross member are made of 50mm x 25mm x 1.2mm MS sections with powder coated finish confirming to IS 13871:1993. Cross members shall be mounted by end brackets. Cross member end bracket shall be made of 3mm thick IS 513: 2008 CRCA sheet with powder coated finish up 40 to 60 Micron DFT.Wire Management: Electrical wires shall be carried from vertical duct or Electrical Legs from floor. Horizontally wire shall float in 105x130 mm cable tray for one sided workstation and 220x130mm cable tray for back to back workstation. Cable tray shall be made of 0.8mm CRCA sheet confirming to IS 513:2008. Horizontal 1 Tier Triangular Cable tray (wire carriers) are made of CRCA & fixed to the understructure below worktop with specially designed brackets. Cable tray will be provided with separation tray for electrical and data wires. Provision for fixing Switch plates are provided in the cable tray for easy access through Aluminium Powder coated Access Flap with soft Closing mechanism of 450mm Lx145mm D. Switches to be mounted on Cable Tray Angular Surface for Easy use. |
| 365 | BOOK SHELF : 4080 X 600 X 750 HT |
| 366 | LOW HEIGHT STORAGE - 4425 X 600 X 500 HT |
| 367 | FULL HEIGHT STORAGE : 2800 X 600 X 2100 HT |
| 368 | FULL HEIGHT STORAGE : 2500 X 600 X 2100 HT |
| 369 | LOW HEIGHT STORAGE - 1200 X 600 X 750 HT |
| 370 | LOW HEIGHT STORAGE - 1440 X 600 X 750 HT |
| 371 | LOW HEIGHT STORAGE - 1705 X 600 X 750 HT |
| 372 | FULL HEIGHT STORAGE - 2080 X 600 X 2100 HT |
| 373 | LOW HEIGHT STORAGE - 3600 X 600 X 750 HT |
| 374 | LOW HEIGHT STORAGE - 5920 X 600 X 500 HT |
| 375 | FULL HEIGHT STORAGE - 3355 X 600 X 2100 HT |
| 376 | STORAGE UNITSTOP :18mm thick prelaminated board with PVC Edge band to all Exposed Area.CARCASS & SHUTTER : 18mm thick. prelaminated board with PVC Edge band with openable ShutterBACK: 18mm thick. prelaminated with PVC Edge band.LOCK : Regular lock Chamfer handles. |
| 377 | Electrical BOQ |
| 378 | Scope includes Testing and Commissioning of system with Preparation of \"As Fitted Drawings\" and submission of 3 Sets of hard copies and 1 Set of soft copy. |
| 379 | Erection Cost shall be included with all necessary accessories required for Erection in all aspects should be included in the Offer. |
| 380 | If any item is missed out, the tenderer is duty bound to quote for the same. The additional items shall be listed and quoted as an attachment with a covering note. Any claim for omissions after the contract is awarded shall be rejected. |
| 381 | Successful bidder to prepare the shop drawingsfor Client / Architect approval before deliver the materials and execute the works at site |
| 382 | LT Panel Board |
| 383 | Note: All bus bar sizes should be per tender only. All the panels will have to be design for 0.7Amps/Sq.mm for Aluminium and 1.2Amps/Sq.mm for Copper bus bar. Gland plates are required. Location of gland plate will have to be deciding by you according to suit the terminal of switchgears and suitable for the cables |
| 384 | All Incoming and Outgoing Switch Gears shall be with IBMS Connectivity for monitoring the ON / OFF / Trip Status |
| 385 | All Energy Meters shall be with IBMS Connectivity for monitoring the required data\"s |
| 386 | Main Panel Board |
| 387 | Supplying, erecting, fabricating, connecting and commissioning a floor mounted cubicle type Panel Board. The Panel Board shall be incorporated with the following:- |
| 388 | Cable Entry : Top |
| 389 | Incomer: 1No 400Amps TPN MCCB of 36kA(Ics) withstanding capacity with Adjustable Overload and Short Circuit Releases of LSIG breaker and Type 1 and 2 Surge Protection Device with digital energy meter with suitable CT and 400Amps Four Pole Auto Transfer Switch with Controller of Socomec make (or) equivalent…1No |
| 390 | Outgoing: 125Amps TPN MCCB of 25kA(Ics) withstanding capacity with Adjustable Overload and Short Circuit Releases…2Nos |
| 391 | 63Amps TPN MCCB of 18kA(Ics) withstanding capacity with Adjustable Overload and Short Circuit Releases…12Nos |
| 392 | Note: The Withstanding capacity mentioned shall be Ics Only. |
| 393 | Busbar : Aluminium |
| 394 | Rating : 400Amps |
| 395 | The Phase Busbar shall be of 100x6mm. and the Neutral bar shall be of 50x6mm. The Earth Busbar shall be of 2Run 25x6mm |
| 396 | There shall be one set of Metering Compartment incorporated with the following:- |
| 397 | I) 3Nos Dual Core Cast Resin CTs of ratio 400 / 5Amps of Class 1.0 for metering and burden 10VA |
| 398 | ii) 1No Digital Multifunction Meter (Voltage, Current, Energy and Frequency) with Selector Switch |
| 399 | iii) OBO BETTERMAN Surge Arrestor |
| 400 | iv) RYB Indication lamp of LED cluster Type with Control Fuses shall also be provided. |
| 401 | Outgoing UPS Panel Board |
| 402 | Supplying, erecting, fabricating, connecting and commissioning a floor mounted cubicle type Panel Board. The Panel Board shall be incorporated with the following:- |
| 403 | Cable Entry : Top |
| 404 | Incomer: 1No 125AmpsTPN MCCB of 25kA(Ics) withstanding capacity with Adjustable Overload and Short Circuit Releases of LSIG breaker Type 1 and 2 Surge Protection Device with digital energy meter…1No |
| 405 | Outgoing: 125Amps TPN MCCB of 25kA(Ics) withstanding capacity with Adjustable Overload and Short Circuit Releases…2Nos |
| 406 | 63Amps TPN MCCB of 18kA(Ics) withstanding capacity with Adjustable Overload and Short Circuit Releases…5Nos |
| 407 | Note: The Withstanding capacity mentioned shall be Ics Only. |
| 408 | Busbar : Copper |
| 409 | Rating : 125Amps |
| 410 | The Phase Busbar shall be of 25x6mm. and the Neutral bar shall be of 25x6mm. The Earth Busbar shall be of 2Run 25x3mm |
| 411 | There shall be one set of Metering Compartment incorporated with the following:- |
| 412 | I) 3Nos Dual Core Cast Resin CTs of ratio 125 / 5Amps of Class 1.0 for metering and burden 10VA |
| 413 | ii) 1No Digital Multifunction Meter (Voltage, Current, Energy and Frequency) with Selector Switch |
| 414 | iii) OBO BETTERMAN Surge Arrestor |
| 415 | iv) RYB Indication lamp of LED cluster Type with Control Fuses shall also be provided. |
| 416 | MCB DBs |
| 417 | Supplying, fixing, connecting & commissioning the following MCB Distribution Boards fixed flush / Concealed with the wall or open on wall on an angle iron frame. cost of angle iron frame to be included. All MCB DBs shall have Double door and incoming adopter box (Powder coated) to receive wires in pipes / cables etc. The adopter box shall have a minimum height of 150mm. All wiring terminations shall be done through copper lugs cost to be included. All Outgoings to be identified on every MCB, and also ferrules to be provided |
| 418 | Vertical Distribution Board |
| 419 | 4Way TPN Vertical MCB DB For Server Rooms Incomer: 125Amps TPN MCCB with 25kA(Ics) Withstanding Capacity with Adjustable Overload and short circuit relay with Surge Protection..1NoOutgoing: 63Amps TP+N MCB..3Nos 6-32Amps SP+N MCB..3Nos |
| 420 | Lighting Distribution Board |
| 421 | 8Way TPN 7 Segment MCB DBIncomer: 63Amps 4P MCB... 1No. Outgoing: 63Amps DP, 30mA RCBO with Surge Protection Device Type 3 .. 3Nos6-32Amps SP MCB... 24Nos |
| 422 | Power Distribution Board for Small Power Socket Outlets |
| 423 | 12Way TPN 7 Segment MCB DBIncomer: 63Amps 4P MCB... 1No. Outgoing: 63Amps DP, 30mA RCBO with Surge Protection Device Type 3 .. 3Nos6-32Amps SP MCB... 36Nos |
| 424 | Power Distribution Board for VRV Indoor Units |
| 425 | 8Way TPN 3-Tier MCB DBIncomer: 63Amps 4P MCB... 1No. Outgoing: 63Amps DP, 30mA RCBO with Surge Protection Device Type 3 .. 3Nos6-32Amps SP MCB... 24Nos |
| 426 | UPS Distribution Board |
| 427 | 12Way TPN 3 Tier MCB DB for Workstations Incomer: 63Amps 4P MCB…1No Outgoing: 63Amps DP, 30mA RCBO with Surge Protection Device Type 3 .. 3Nos 6-32Amps SP MCB… 36Nos. |
| 428 | 4Way TPN 3 Tier MCB DB For Simulation Lab, HVAC System and Server RoomsIncomer: 63Amps 4P MCB…1No Outgoing: 63Amps DP, 30mA RCBO with Surge Protection Device Type 3 .. 3Nos 6-32Amps SP MCB… 12Nos. |
| 429 | Emergency Lighting Distribution Board |
| 430 | 16Way SPN MCB DBIncomer: 40Amps DP, 30mA RCBO with Surge Protection Device Type 3 …1NoOutgoing: 6-32Amps SP MCB... 10Nos |
| 431 | MCB / FSU/ MCCB Control |
| 432 | Supplying, erecting, connecting and commissioning of 125Amps 4Plole MCCB of 25kA(Ics) withstanding capacity with adjustable overload and short circuit releases, with Weather proof enclosure on an angle Iron frame with necessary interconnections, cable box, brackets, screws, bolts, nuts, etc to complete the erection works for Incoming and Outgoing Control of 30kVA and 60kVA UPS System |
| 433 | Supplying, erecting, connecting & commissioning on weather proof enclosure with 63Amps 4 Pole 300mA RCBO and Phase Reversal Relay in MS Enclosure on an angle iron frame with necessary interconnections, cable box, brackets, screws etc. for VRV Outdoor Units |
| 434 | Supplying, erecting, connecting & commissioning on weather proof enclosure with 63Amps 4 Pole MCB on an angle Iron frame with necessary interconnections, cable box, brackets, screws, bolts, nuts, etc. to complete the erection works |
| 435 | Supplying, erecting, connecting & commissioning on weather proof enclosure with 40Amps Double Pole MCB on an angle Iron frame with necessary interconnections, cable box, brackets, screws, bolts, nuts, etc. to complete the erection works for Incoming and Outgoing Control of 6kVA UPS for Emergency Lighting Purpose |
| 436 | Supplying, erecting, connecting & commissioning on weather proof enclosure with 6Amps Double Pole MCB in MS Enclosure on an angle iron frame with necessary interconnections, Wire box, brackets, screws etc. for VRV Indoor Units (5Nos Hi-Wall Spilt and 2Nos Cassette Units) |
| 437 | Cables |
| 438 | Supplying, laying, connecting & commissioning the following 1.1KV Grade XLPE Insulated Underground cables with necessary clamps, screws, etc. inthe following methods:- |
| 439 | Laid in Buried Under Ground, clamped along with wall / column / laid in tray |
| 440 | 4C 400 Sq.mm. Al |
| 441 | 4C 70 Sq.mm. Cu |
| 442 | 4C 35 Sq.mm. Cu |
| 443 | 4C 16 Sq.mm. Cu |
| 444 | 4C 10 Sq.mm. Cu |
| 445 | 4C 6 Sq.mm. Cu |
| 446 | 3C 10 Sq.mm. Cu |
| 447 | 3C 4 Sq.mm. Cu - Flexible (Black colour for Raw and White colour for UPS Power) |
| 448 | 3C 2.5 Sq.mm. Cu - Flexible (Black colour for Raw and White colour for UPS Power) |
| 449 | Supplying, terminating, connecting and commissioning the above Underground cables with Double compression type SIBG Cable glands. Thecost of earthing gland with copper strips / wires shall also be included. The cables shall be terminated with aluminium / copper lugs after crimping |
| 450 | 4C 400 Sq.mm. Al |
| 451 | 4C 70 Sq.mm. Cu |
| 452 | 4C 35 Sq.mm. Cu |
| 453 | 4C 16 Sq.mm. Cu |
| 454 | 4C 10 Sq.mm. Cu |
| 455 | 4C 6 Sq.mm. Cu |
| 456 | 3C 10 Sq.mm. Cu |
| 457 | Mains Wiring |
| 458 | Note: All conduits above false ceiling shall be properly fixed on RCC Ceiling on 1.5mm thick brackets details to be furnished by successful bidder along with shop drawings |
| 459 | Power Wiring - Raw Power Socket Outlets |
| 460 | Note: All conduits above false ceiling shall be properly fixed on RCC Ceiling on 1.5mm thick brackets details to be furnished by successful bidder along with shop drawings |
| 461 | Note: Please get sample approval before dispatch the materials at site as well as specify on tender documents with respect to model name considered in commercial offer |
| 462 | Supplying, laying, connecting and commissioning 3Runs of 1.5Sq.mm PVC Insulated multistranded copper conductor FRLS wires (One each for Phase, Neutral and earth) wires for continuous earthing in already laid Conduits concealed in floor / wall / partitions or laid in open fashion above false ceiling with necessary clamps, screws etc., for 6Amps Socket Raw Power Outlet - VAV Units |
| 463 | Supplying, laying, connecting and commissioning 3Runs of 2.5Sq.mm PVC Insulated multistranded copper conductor FRLS wires (One each for Phase, Neutral and earth) wires for continuous earthing in already laid Conduits concealed in floor / wall / partitions or laid in open fashion above false ceiling with necessary clamps, screws etc., for 6Amps Socket Raw Power Outlet -VRV Indoor Units |
| 464 | Supplying, laying, connecting and commissioning 3Runs of 2.5Sq.mm PVC Insulated multistranded copper conductor FRLS wires (One each for Phase, Neutral and earth) wires for continuous earthing in already laid Conduits concealed in floor / wall / partitions or laid in open fashion above false ceiling with necessary clamps, screws etc., for 6Amps Socket Raw Power Outlet - General Purpose |
| 465 | Supplying, laying, connecting and commissioning 2Runs of 4Sq.mm PVC Insulated multistranded copper conductor FRLS wires (One each for Phase, Neutral) with 1Run of 2.5Sqmm. PVC Insulated multistranded FRLS copper conductor wires for continuous earthing in already laid Conduit concealed in wall / partitions or laid in open fashion above false ceiling with necessary clamps, screws etc., for 6/16Amps Socket Raw Power Outlet |
| 466 | Supplying, laying, connecting and commissioning 2Runs of 6Sq.mm PVC Insulated multistranded copper conductor FRLS wires (One each for Phase, Neutral) with 1Run of 2.5Sqmm. PVC Insulated multistranded FRLS copper conductor wires for continuous earthing in already laid Conduit concealed in wall / partitions or laid in open fashion above false ceiling with necessary clamps, screws etc., for 25Amps Socket Raw Power Outlet |
| 467 | Supplying and fixing 6Amps Switched Socket combined in Manufacturer\"s mounting box fixed flush with the wall for VRV Indoor and VAV Units |
| 468 | Note: In one Circuit there shall be 1Set of 6Amps Socket shall be wired |
| 469 | Supplying, fixing, connecting & commissioning 1x6Amps Socket with 1x6Amps Switch housed in Manufacturer\"s mounting box fixed flush with the wall (or) on partitions with necessary accessories such as screws bolts & nuts etc. |
| 470 | Note: In one Circuit there shall be 8 to 10 Sets of 6Amps Socket shall be wired |
| 471 | Supplying, fixing, connecting & commissioning of 1x6/16Amps Socket with 1x16Amps Switch housed Weather Proof enclosure in Manufacturer\"s mounting box fixed flush with the wall (or) on partitions with necessary accessories such as screws bolts & nuts etc. |
| 472 | Note: In one Circuit there shall be 2Sets of 16Amps Socket shall be wired |
| 473 | Supplying, fixing, connecting & commissioning 1x6/16Amps Socket with 1x16Amps Switch housed in Manufacturer\"s mounting box fixed flush with the wall (or) on partitions with necessary accessories such as screws bolts & nuts etc. |
| 474 | Note: In one Circuit there shall be 2Sets of 16Amps Socket shall be wired |
| 475 | Supplying, fixing, connecting & commissioning of 1x25Amps Socket with 1x25Amps Switch housed Weather Proof enclosure in Manufacturer\"s mounting box fixed flush with the wall (or) on partitions with necessary accessories such as screws bolts & nuts etc. |
| 476 | Note: In one Circuit there shall be 1Sets of 25Amps Socket shall be wired |
| 477 | Supplying and laying the 25mm. Dia Heavy-duty PVC conduits concealed in ceiling / wall / floor with necessary accessories to complete the erections works with 1Run 16 SWG GI Fish wire. |
| 478 | Supplying, laying of 25mm Dia MS flexible hose laid in partitions with necessary supports clamps, screws etc. |
| 479 | Supplying, laying 25mm. Dia MS Conduits laid in open fashion above false ceiling, wall / partitions with necessary clamps, screws etc. |
| 480 | Light Point Wiring |
| 481 | Note: All conduits above false ceiling shall be properly fixed on RCC Ceiling on 1.5mm thick brackets details to be furnished by successful bidder along with shop drawings |
| 482 | Note: Please get sample approval before dispatch the materials at site as well as specify on tender documents with respect to model name considered in commercial offer |
| 483 | Supplying, wiring, connecting & commissioning thelight points with 3Runs of 1.5Sq.mm. PVC insulatedmultistranded Copper Conductor FRLS wires (One each for Phase, Neutral and earth) in already laid MS Conduits concealed in wall / partitions or laid in open fashion above false ceiling with necessary clamps, screws etc., including supplying and fixing 6Amps Switch in manufacturers mounting box fixed flush with the wall / Partitions. The maximum length will be 10.0Mtrs from switch board to 1st light point |
| 484 | One Light Controlled by one Switch - Primary Point |
| 485 | Supplying, wiring, connecting & commissioning the light points with 3Runs of 1.5Sq.mm. PVC insulated multi stranded copper Conductor FRLS wires (One each for Phase, Neutral and Earth) in already laid MS Conduits concealed in wall / ceiling or laid in open fashion above false ceiling with necessary clamps, screws etc. for additional points. The additional points will have to be wired from the first point mentioned under Item under Item No.07.01.01 The maximum length will be 5.0 Mts. for each additional point. |
| 486 | Supply, Laying, Connecting & commissioning of 3Runs of 2.5 Sq.mm. PVC insulated multistranded Copper Conductor FRLS wires (One each for Phase, Neutral and Earth) in already laid MS Conduits concealed in wall / ceiling with necessary Accessories from LDB to First Switch Board and Switch Board to Switch Board. |
| 487 | Supply, Laying, Connecting & commissioning of 3Runs of 1.5 Sq.mm. PVC insulated multistranded Copper Conductor FRLS wires (One each for Phase, Neutral and Earth) in already laid MS Conduits concealed in wall / ceiling with necessary Accessories for additional Lenths if point wiring exceeds more than 10.0Mtrs |
| 488 | Supplying, laying of 25mm Dia MS flexible hose laid in partitions with necessary supports clamps, screws etc. |
| 489 | Supplying, laying 25mm. Dia MS Conduits laid in open fashion above false ceiling with necessary clamps, screws etc. |
| 490 | UPS Wiring |
| 491 | Note: Please get sample approval before dispatch the materials at site as well as specify on tender documents with respect to model name considered in commercial offer |
| 492 | Supplying, laying, connecting and commissioning 3Runs of 2.5Sq.mm PVC Insulated multistranded copper conductor FRLS wires (One each for Phase, Neutral and earth) wires for continuous earthing in already laid Conduits concealed in floor / wall / partitions or laid in open fashion above false ceiling with necessary clamps, screws etc. for 6Amps Socket UPS Power Outlet |
| 493 | Supplying, laying, connecting and commissioning 2Runs of 4Sq.mm PVC Insulated multistranded copper conductor FRLS wires (One each for Phase, Neutral) with 1Run of 2.5Sqmm. PVC Insulated multistranded FRLS copper conductor wires for continuous earthing in already laid Conduit concealed in wall / partitions or laid in open fashion above false ceiling with necessary clamps, screws etc., for 6/16Amps Sockets |
| 494 | Supplying, fixing, connecting & commissioning of 1x6Amps Multi-Pin UPS Sockets with 1x6Amps Switch housed in Manufacturer\"s mounting box fixed flush with the wall (or) on partitions with all other accessories to complete the erection works |
| 495 | Note: In one Circuit there shall be 2 to 8 Sets of 6Amps Switched Socket shall be wired |
| 496 | Supplying, fixing, connecting & commissioning of 2x6Amps Multi-Pin UPS Socket with 1x16Amps Switch housed in Manufacturer\"s mounting box fixed flush with the wall (or) on partitions with all other accessories to complete the erection works |
| 497 | Note: In one Circuit there shall be 4 Sets of 2x6Amps Socket shall be wired |
| 498 | Supplying, fixing, connecting & commissioning of 3x6Amps Multi-Pin UPS Socket with 1x16Amps Switch housed in Manufacturer\"s mounting box fixed flush with the wall (or) on partitions with all other accessories to complete the erection works |
| 499 | Note: In one Circuit there shall be 2Sets of 3x6Amps Socket shall be wired |
| 500 | Supplying, fixing, connecting & commissioning of 1 x 6/16Amps Switched Socket Combined in Manufacturer\"s mounting box fixed flush with the wall with all other accessories to complete the erection works |
| 501 | Supplying, fixing, connecting & commissioning of 1 x 32Amps Industrial Type Plug and Socket with interlock arrangements for Server Racks in Manufacturer\"s mounting box fixed flush with the wall with all other accessories to complete the erection works |
| 502 | Supplying and laying the 25mm. Dia Heavy-duty PVC conduits concealed in ceiling / wall / floor with necessary accessories to complete the erections works with 1Run 16 SWG GI Fish wire. |
| 503 | Supplying, laying of 25mm Dia MS flexible hose laid in partitions with necessary supports clamps, screws etc. |
| 504 | Supplying, laying 25mm. Dia MS Conduits laid in open fashion above false ceiling with necessary clamps, screws etc. |
| 505 | Aluminium Race Ways |
| 506 | Supplying, laying, connecting the Aluminium Raceways laid in the Floor with all necessary clamp, screws etc. including Floor Cutting, breaking and removing debris and plastering with chicken mesh for floor raceways along with final floor finish |
| 507 | 60 x 38mm. |
| 508 | 100 x 38mm. |
| 509 | Empty PVC Conduit for Data & Voice |
| 510 | Supplying and laying the following PVC Heavy duty Conduits concealed / open in wall / floor etc. withnecessary clamps, screws etc. with 1Run of 16SWG GI Fish wire. |
| 511 | 25mm Dia PVC Conduits |
| 512 | 32mm Dia PVC Conduits |
| 513 | 50mm Dia PVC Conduits |
| 514 | Supplying, fixing, connecting & commissioning GI Base box for Data with necessary screws etc. The Data Socket with front plate shall be supplied by the Client at Site. |
| 515 | Supplying, laying of 25mm. Dia PVC flexible hose laid in partitions with necessary supports clamps, screws etc. |
| 516 | Supplying, laying of 32mm. Dia PVC flexible hose laid in partitions with necessary supports clamps, screws etc. |
| 517 | Empty MS Conduits |
| 518 | Supplying and laying the following MS Conduits Suspended from ceiling with threaded rods in every 1meter with necessary clamps, screws etc. with 1Run of 16 SWG GI Fishwire. |
| 519 | 25mm Dia MS Conduits |
| 520 | 32mm Dia MS Conduits |
| 521 | Empty PVC Conduits |
| 522 | Supplying and laying the following PVC Heavy duty Conduits concealed / open in wall / floor etc. withnecessary clamps, screws etc. with 1Run of 16SWG GI Fish wire. |
| 523 | 25mm Dia PVC Conduits |
| 524 | 32mm Dia PVC Conduits |
| 525 | Junction Boxes |
| 526 | Supplying, erecting 14Gauge thick Junction boxeswith cover of 50mm. height to suit as per site conditions. The Junction boxes shall be powder coated type and fixed flush with the wall / floor |
| 527 | Chequer Plates |
| 528 | Supplying and fixing 10mm. thick MS Chequered plates as floor separators for covering the shafts with angle iron supports at floor level . |
| 529 | Earthing |
| 530 | Supplying, installing and connecting a Copper plate of size 600x600x3mm. at a depth of 3000mm.in an earth pit of 700x700x3500mm. filled with salt and charcoal mixed with sand in alternate layers 150mm. each up to a height of 3000mm. from bottom. Two copper flats of 25x6mm. Shall be braced to this copper plate through out the over lapping length with the copper plate and brought to the surface of the earth pit. This copper flat shall have provision f1or connecting wires off lats as the case may be. A suitable size of 40 mm.dia GI Pipe shall be provided uptil the bottom of the earth pit. This GI Pipe shall have provision for watering through a funnel. A masonry structure shall be constructed to a depth of 450 mm. and a heavy duty CI Cover shall be used to cover the pit. The cost of digging and back filling shall also be included. Sand, salt and charcoal are in the Contractor\"s scope. |
| 531 | Supplying, laying and connecting of 25x3mm copper Flat laid in Floor with necessary clamps, screws, interlinks etc. |
| 532 | Supplying, laying and connecting of 25x3mm copper Flat laid in open fashion with necessary clamps, screws, interlinks etc. |
| 533 | Supplying, laying and connecting 50x6mm. GI Flat laid in open fashion with necessary clamps, screws, interlinks etc.. |
| 534 | Supplying, laying and connecting 25x6mm. GI Flat laid in open fashion with necessary clamps, screws, interlinks etc.. |
| 535 | Supplying, laying and connecting 300mm. long 25x3mm. Copper flat with SMC/ DMC Insulators inopen fashion with necessary clamps, screws, etc. |
| 536 | Supplying, laying and connecting 300mm. Long 50x6mm GI flat in open fashion with necessary clamps, screws, etc. as earth link |
| 537 | Supplying, laying and connecting 2Runs of 35 Sq.mm. PVC Insulated copper conductor wires laid in heavy duty PVC Conduits concealed in floor with necessary clamps, screws, interlinks etc., for UPS Neutral Earthing |
| 538 | Supplying, laying and connecting 2Runs of 16 Sq.mm. PVC Insulated copper conductor wires laid in heavy duty PVC Conduits concealed in floor with necessary clamps, screws, interlinks etc., for UPS Earthing |
| 539 | Supplying, laying and connecting 2Runs of 10 Sq.mm. PVC Insulated copper conductor FRLS wires laid in heavy duty PVC Conduits concealed in floor with necessary clamps, screws, interlinks etc., For Data Earthing |
| 540 | Supplying, laying and connecting 2Runs of 4 Sq.mm. PVC Insulated copper conductor FRLS wires laid in heavy duty PVC Conduits concealed in floor with necessary clamps, screws, interlinks etc., for Data Earthing |
| 541 | Supplying, laying, connecting 8SWG bare enamelled copper wire enclosed in MS Conduits with necessary clamps, screws etc. |
| 542 | Supplying, laying, connecting 10SWG bare enamelled copper wire enclosed in MS Conduits with necessary clamps, screws etc. |
| 543 | Structural Supports |
| 544 | Fabricating, supplying, erecting and connecting & commissioning Cable Trays of following measurements with necessary Box Channel for cable supports and other allied fabrication works. Fixing to concrete surfaces shall be done with the help ofexpandable type anchor fasteners capable of bearing a weight of 500 Kgs. Fixing to brick walls shall be done by grouting. The distance between two supports shall be 2000mm. The materials and labour for grouting, cable supports and other allied fabrication work shall supplied by the Contractor. 50x6mm. GI Flat shall be bolted throughout with connection point once every 7Mtrs. on both sides. |
| 545 | Perforated type - Laid on Ceiling |
| 546 | Supply and fixing of Perforated GI Cable Tray with Top cover, horizontal & vertical bends, reducers, Tee\"s, cross over, supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be made of 2mm thick sheet steel hot dip galvanised (confirming to ISO 1461). The trays should be tested for a safe working load of 250Kgs Per Mtr with a span distance of 1.5Mtrs and the deflection should be within the limits as per standard. The perforated tray shall be supplied with the standard length of 3Mtrs. The Tray shall be fixed above false ceiling with necessary supports. Provision to fix 50x6mm GI Flat on both the sodes of cable tray throughout with connection point once every 7Mtrs. Tray Should be Powder Coated. Cable Tray cost should be included with paint shade given by Architect later date for Electrical and LV System |
| 547 | 50mm Width x 50mm Height |
| 548 | 100mm Width x 50mm Height |
| 549 | 150mm Width x 50mm Height |
| 550 | 300mm Width x 50mm Height |
| 551 | 450mm Width x 50mm Height |
| 552 | Light Fixtures - Supply and Erection |
| 553 | Note: Please get sample approval before dispatch the materials at site as well as specify on tender documents with respect to model name considered in commercial offer |
| 554 | Supply, Fixing, connecting and commissioning of Various Type Light fixtures as per Lighting Layout given by Architect with all necessary accessories required to complete the erection |
| 555 | Lighting Sensor |
| 556 | Supply, fixing, connecting and commissioning of Surface mounted PIR occupancy sensor with coverage range of 6.0Mtrs Diameter, high performance, compact presence detectors provide automatic control for lighting. It detects human presence and automatically turns the lights \"ON\". when the area is vacated, the lights turn \"OFF\" after a preset time period - Open Office Area |
| 557 | Supply, fixing, connecting and commissioning of Surface mounted PIR occupancy sensor with Coverage range of 6.0Mtrs Diameter, highly sensitive, microwave presence detectors provide automatic control of lighting. It works by emitting low power microwave signals and measuring reflections as the signals bounce off moving objects. It has a unique adjustable sensor that allows the area of detection to be optimized for the application. - Closed Cabin Area |
| 558 | UPS |
| 559 | Note: Please check the physical dimensions of equipment\"s to accommodate within the available UPS Room. Presently we had considered M/s.Vertiv Make for space calculations |
| 560 | UPS with SNMP and Network Card for Monitoring |
| 561 | 2x20kVA UPS and provisions for adding 1x20kVA UPS in Future - 3-Phase IN and OUT. Model Number ITA-20K00AE3A02P00 of Vertiv Make |
| 562 | 6kVA UPS for Emergency Lights Purpose |
| 563 | Battery Bank |
| 564 | (Battery Rating Calculations for rated UPS Capacity to be submitted along with offer) |
| 565 | Supplying, erecting, connecting and commissioning Closed Battery racks made out of MS painted with powder coated paint with necessary caster wheels, batteries for following back time. The cost shall also including supplying and fixing MCCB also. |
| 566 | 15Minutes Battery Bank for 60kVA UPS at full load for Workstations |
| 567 | 15Minutes Battery Bank for 6kVA UPS at full load for Emergency Light Purpose |
| 568 | Supplying, erecting, connecting and commissioning Closed FRP Battery with racks made out of MS painted with powder coated paint with necessary caster wheels, batteries for required full load back time. The cost shall also including supplying and fixing MCB/MCCB also. |
| 569 | Remote Monitoring Panel |
| 570 | Miscellaneous |
| 571 | Liaison with The Chief Electrical Authority of Government for preparation of Working drawings etc., obtaining approval for drawing and getting Safety Certificate, approval for Energisation. (End to End Co-ordinations with CEA officials) - Client shall pay all statuary fees directly at the time of receiving necessary documents |
| 572 | Removing and dismantling the existing unused electrical items |
| 573 | Removing and dismantling the existing 2 x 125Amps TPN Tap Box in existing Rising Mains at inside Electrical Room with ATS Arrangements including Cable and Terminations Etc to be handed over to Base Builder maintenance team at 1st Floor Level of Block E |
| 574 | Supply, fixing, connecting and commissioning of 2 x 400Amps TPN Tap Box at existing Rising Main at inside Electrical Room with all other accessories to complete the erection works including the Energy Meter as per site conditions |
| 575 | Lighting |
| 576 | CANE G7 DOWN 36W 4000K CCT 8Feet NON DIM BLACK (PC) PENDANT CRI 80 IP20 - OC |
| 577 | CANE G7 DOWN 36W 4000K CCT 8Feet NON DIM BLACK (PC) PENDANT CRI 80 IP20 - BC |
| 578 | CANE G7 DOWN 25W 4000K CCTNON DIM BLACK (PC) PENDANT CRI 80 IP20 - OCL1650mm |
| 579 | CANE G7 DOWN 25W 4000K CCTNON DIM BLACK (PC) PENDANT CRI 80 IP20 - BCL1650mm |
| 580 | FULL LIT CR SLIM V2 36W 5700K CCT NON DIM WHITE(PC) RECESS MOUNTING CRI 80 IP20 |
| 581 | INTENSO MAX DIFFUSED 30W 4000K CCT NON DIM BLACK(PC) PENDANT CRI 80 IP20 |
| 582 | INTENSO MAX DIFFUSED 18W 4000K CCT NON DIM BLACK(PC) PENDANT CRI 80 IP20 |
| 583 | ALPEN DR INT 24W 4000K CCT NON DIM BLACK(PC) PENDANT CRI 80 IP20 |
| 584 | DARKLIT ADJUSTABLE 10W 4000K CCT NON DIM WHITE(PC) RECESS MOUNTING CRI 80 IP20 |
| 585 | SYPHON V2 10W 4000K CCT NON DIM WHITE(PC) TRACK MOUNTING CRI 80 IP20 |
| 586 | TRACK FOR LIGHT FIXTURE - SURFACE - 2Mtr - With all accessories |
| 587 | GEOMET 20W/MTR RGB DMX BLACK(PC) PENDANT CRI 80 IP20W35 X H40mm |
| 588 | GEOMET 16W/MTR 4000K CCT NON DIM BLACK(PC) PENDANT CRI 80 IP20W35 X H40mm |
| 589 | INTENSO IP DL DOWN LIGHT RECESS 24W 4000K CCT NONDIM WHITE (PC) PRIME 60 Beam angle |
| 590 | CLIMBER UPDOWN OUTDOOR ARCHITECTURAL 10W 3000K CCT NON DIM EBONY BLACK (PC) PRIME 45 Beam Angle |
| 591 | LT Maze LED Strip 10W 24V 4000K with Triangle Surface Mount Aluminum Profile and PC diffuser with Endcap and Mounting clip: 16mm X H: 16mm and driver |
| 592 | HVAC BOQ |
| 593 | CHW : CEILING SUSPENDED UNITS : |
| 594 | Supply, installation,testing,Unloading,Leading,Positioning & commissioning of Ceiling Suspended Air handling unit complete with filter sectionhaving pre filters, min of6 row coil, 5 fins per Cms, chilled water coils of copper tube & aluminium fins construction, fan section with SIDW/DIDW suitable type preferably Belt driven to suit, canvas provision, supports, vibration isolators etc. Face velocity across filter & coil shall not exceed 1.78M/S to reduce noise level. CSU Wall Panels shall be of min 25 mm thick with Pressure injected sandwich type poly urethene foam insulation panel. Minimum density of panel shall be with 48kg/m3 & fabricated out of outer sheet of minimum 0.8 mm thick galvanised preplasticised sheet and inner sheet of 0.6mm thick plain G.I sheet. Condensate drain pan shall be fabricated from 1.2 mm thick stainless steel SS 304 sheet. The motor selected shall be energy efficient TEFC squirrel cage motor (IE3) with IP55 protection, Class F insulation with temperature raise limited to class B for an ambient of 45 deg C. Motor shall be suitable for 400±10% volts, 50 cycles, 3 phase AC supply. Sound level of unit shall not exceed 50db @ 1m from the filter. Bidder to provide acoustic insulation for fan housing and CSU panels with min of 10 -13mm thick along with perforated sheet. Coil Conditions considered is: EWT - 8 Deg C, LWT - 15 Deg C. (To be verified by supplier and select to suit). CSU shall have a local MCCB for switching off the unit and a control panel for operating the CHW automatic control Valves. The electrical panel (to be quoted with CSU including installation etc as required) . The electrical panel shall have all inbuilt transformers etc and the same shall be fitted near the CSU s and vendor shall ensure accessibility through Trap door for servicing of panels / units. Further, the CSU shall also have a separate VFD control and the entire VFD, it\"s control panel along with Pr differential sensors/ transmitters, Temp Sensors / Temp Transmitters / RA Sensors etc as required for controlling CSU along with Switch shall be provided by CSU Supplier. VAV to VFD compatibility communication support shall be in bidders scope & it will be bidders responsibility to ensure it is done at their cost. Panel price shall be included in the CSU. Panel to be considered and quoted by bidder along with CSU. i.e. Depending on VAV opening percentage, Any BMS integration, required power and communication cables are part of vendor scope. VFD of fan shall automatically adjust and vary the fan speed). Complete Integration of VAV to VFD shall be in HVAC low side bidder scope. In addition, small trays shall be provided for the actuator & Valve areas to avoid any sweating of water falling over false ceiling area. After installing, it will be the bidders responsibility to do air balancing and change / modify pulley of CSU Motor & Fan Pulley to ensure designed / required flow is given / achieved to the conditioned space. |
| 595 | CSU 01 - 16.0 TR - 6400 CFM @ 55 mm Total Static Pressure (ESP 30 mm) or to suit |
| 596 | CSU 02 - 16.0 TR - 6400 CFM @ 55 mm Total Static Pressure (ESP 30 mm) or to suit. |
| 597 | CHW : CASSETTE / HI WALL UNITS : |
| 598 | SITC Cassette Unit / HWM Unit as per below capacity along with necessary grill, Remote control, Drain Pump etc suitable for Chilled water system operating at 15/8 deg c, including necessary insulation, drain line fresh air provision etc as required in full to complete the unit installation along with necessary filters, temperature controllers, including flow control arrangement of chilled water provision along with necessary control panel / PCB etc as required to complete installation. Any supporting arrangement / fixing arrangement for the unit shall also to be considered by the Bidder. Cost ofCordless Remote as required / Communication & power cables for IDU as required shall also be considered by the bidder. |
| 599 | 1.0 TR HWM Unit (Café) |
| 600 | 1.6/1.5 TR Four Way Cassette ( 8 Pax 1 & 2) |
| 601 | 1.3/1.5 TR HWM Unit (UPS Room 1+1) |
| 602 | 2.0 TR HWM Unit (Server Room 1+1) |
| 603 | Drain Pump For CSU / HWM / Cassette / As required at site. The pump shall be capable to extract the unit drain and shall start / stop automatically as required. The complete wiring/ electrical switch/connections etc shall be in HVAC bidders scope between the units and the drain pump or as required. |
| 604 | Removal of Existing AHU at Site . |
| 605 | Miscellaneous like transportation of units / Supervision of units erection/Scaffolding / Freight, Leading of Material including Minor civil works etc |
| 606 | IMPORTANT NOTES : |
| 607 | It is Vendors responsibility to study the drawing and Inspect the site before quoting for the project, The bidder shall guarantee for the performance in toto. Any coordination between vendors as required for completing the work successfully will be in HVAC Bidder scope. |
| 608 | It is very important that the vendor shall take approval for all the make / materials etc with COERS / IITM / Architect before procuring and they have to confirm the make to be supplied in the initial stage itself. Bills will not be processed for materials which are not approved by IITM / COERS |
| 609 | All measurement above are indicative and the quantity shall be billed and paid on actual measurement basis. Any Minor civil work like brick wall opening / plastering etc for running ducts will be in the scope of bidder and the same shall be considered by them. Civil work must be taken care by specialised civil agency under scope of bidder. |
| 610 | GST % are given as indicative and Vendor shall ensure the correct % while quoting. |
| 611 | Electrical cables i.e. All Power Cables between IDU s and ODUs if any, Main Incoming Panel required for the Units, Incoming Cables etc if any are not covered in this pricing. Any communication cable between IDU to VAV will be in bidder scope. Incoming Power t units will be given by client at one point. |
| 612 | The above BOQ is based on the drawing we submitted and is indicative which is bound to change as it is given for reference purpose. Bidder to identify and update all possible missed out requirements to complete the system before bidding. |
| 613 | VAV - VFD Communication scope shall be with low side Bidder. However any requirement on high side (CSU/AHU Supply) shall be indicated by low side bidder and it will be the responsibility of HVAC bidder in toto to complete the job in full and ensure that it is in working condition to the satisfaction of client while handing over. |
| 614 | All control cable and Power cable required for VAV shall be in HVAC low side Supplier scope. Complete scope of work will lie on HVAC bidder. |
| 615 | CHW is Supplied to CSU/AHU at 8 DEG C with a tolerance of around 10% on both sides |
| 616 | Bidder to provide NO/NC Contact interlock for all the CSU/AHU Units supplied which will be linked to FAS so that in case of any FAS, the unit shall be switched off. Requisite interlocking cables etc and co ordination with FAS vendor shall be done by hvac bidder. Cost for interlock shall be considered by HVAC Bidder including cables etc |
| 617 | SITC of requisite Chilled water supply and return along with the valves, insulation, strainers etc as required for the system |
| 618 | Noise Level of CSU/AHU shall be as low as possible and bidder shall try to achieve lower than the noise level indicated above against each units. If required the complete boxing shall also be acoustically insulated along with the trap doors to reduce the noise level in addition to CSU fan housing and CSU inner panels. |
| 619 | BMS Integration and its cost for all the unis shall be in bidders scope and the same shall be communicated to the required location as per client requirement. |
| 620 | The bidder has to follow the above important notes , In addition they have to follow the tender specifications given by the client. Whichever specs is stringent will have to be followed by the bidder and the same needto be noted. |
| 621 | VRF |
| 622 | VRF SYSTEM DESCRIPTION |
| 623 | Supply, installation, testing & commissioning of VRF Air-Conditioning system with R 410 A gas complete with indoor units, outdoor units, refrigerant, control cabling, earthing, insulation and the required controls for automatic temperature control. All the ODU shall have a ELCB/MCCB Separately as required and the same shall be included by the bidder in his cost. Client will only give input power to ODU. From ODU to IDU , requisite power / communication cable etc will be provided by the bidder. Any support angle required for ODU with vibration isolator (rubber pads) shall be provided by the bidder. |
| 624 | OUTDOOR UNIT |
| 625 | 26 HP (14+12)Min Capacity Variable Refrigerant Flow Outdoor unit of inverter driven compressor (Variable speed, Scroll), with Air cooled condenser, fan motor, vibration isolation pads etc as required along with independent ELCB / MCCB for every ODU. (14 HP x 1 No & 12 HP x 1 No ). Units shall be capable to operate up to 50 deg c ambient and bidder to share all technical details during bidding with part load operation at standard and at 40 deg ambient conditions. Units supplied should have BMS protocol to be supported which the bidder to note. |
| 626 | INDOOR UNIT : AIR HANDLING UNIT |
| 627 | Supply, Installation, Leading, Positioning, Testing and commissioning of 20.0 TR Capacity (To Suit) around 8000 CFM, with 60 mm Total static pressure. (50 mm thick PUF panels, density of 40kg/cum, with min 0.6-mm thick inner & 0.8-mm outer skin) units, having 50mm base channel frame, Pre-filter section alongfilter frame,The AHU Shall have min 4 row DX Cooling coil section to suit the ODU Selected along with the AHU. The AHU shall have a drain pan with min 1.2-mm thick Stainless steel (SS 304) material. Pan should be Insulated with min 13-mm thick Nitrile rubber at the bottom. The AHU shall have copper tubes of min 0.5 mm thick with at least 12 fins per inch. The Vendor should consider suitable expansion Valve, Filter Drier (AHU KIT if any) so that the AHU is coupled with the selected ODU. AHU shall also have a suitable fan blower with fan motor of minimum IE 3 Type, Class F, IP 55 Minimum, with fan with belt drive to suit, along with necessary mounting frame, support structure from ceiling, Vibration isolators, Aluminium structural frame work, Fire retardant flexible connection, Access door and Access door limit switch, Coils shall be sized to meet desired conditions of room specs. The Coil face velocity shall not exceed 2 M/s. The equipment shall be considered with installation, testing and commissioning of AHU wall mountable electrical starter panel, interconnecting cable cost, main circuit breaker, LCD screen with temperature indicator etc. Panel shall be preferably wall mounted type, powder coated type. The electrical panel shall have potential free relay contacts to be interlocked with fire alarm control module & BMS on/off command, trip status. AHU fan housing shall be suitably insulated for noise reduction. Bidder to finally modify pulley Dia as reqd of AHU during air balancing to ensure sufficient volume is only circulated as required. |
| 628 | Communication Cable between for all Indoor and Outdoor unit to suit (In case of Power cable required same to be considered by Vendor accordingly for interconnecting IDU & ODU) |
| 629 | Standard starter control Panel (With VFD) for AHU along with all interconnecting Cables with a Push button for emergency stop. Complete connection to AHU and its control will be in VRF Supplier scope. From Panel to AHU power / control cable to be considered by VRF bidder.Client will only Provide input supply to the panel at one end. The panel shall have a NO/NC point so that it can be interconnected with Fire alarm to switch off AHUsin case of an emergency situation. Bidder to ensure its co ordination is done with fire vendor. The Panel should have temperature Sensor and the same to be adjustable and will have the control for VRF compressor Operation as per the load in system. Surge Protection and earth leak protection to be added in the panel as required |
| 630 | SITC of Electrical Cable from Panel to AHU and its control cabling including termination of Motors, cable tray, Cable ties etc as required etc with in the AHU room to complete the work in total so as to make the AHU work in perfect condition.Any cable tray / Conduits required along with earthing, termination, Gland earthing, cable tie etc as required in tot shall be considered by the HVAC bidder. |
| 631 | AHU Kit for interconnecting the IDU & ODU |
| 632 | COPPER PIPING DETAILS |
| 633 | SITC ofInter connected copper refrigerant piping with necessary Cable Tray/ supporting arrangements of min 19G Thk , EPDM tube insulation, fittings as required, pressure testing along with the indoor / out door. The piping\"s shall be coatedwith minimum of one coat of primer and two coats of enamel Painting. In case if the piping requires insulation the same shall be done for the liquid line and suction line or as required along with all fittings, valves, and strainer bodies etc with min 13mm thick elastomeric nitrile rubber or to suit respectively so that no sweating happens.All piping support shall be pre fabricated type and pre painted slotted angle support which has to be properly insulated with clamps etc. To protect the nitrile rubber insulation of exposed copper piping from degrading due to UV rays and atmospheric condition, the insulation shall be covered with Polyshield coating with at least two coats of resin and hardener (preferably with Polybond make or equivalent) over and above the nitrile rubber insulation (wherever applicable). Fiber glass tape shall be helically wound to give smooth and paint finish.The refrigerant piping shall be hard drawn heavy duty copper of various sizes as per OEM recommendation with necessary supports,as required with all fittings between outdoor unit & indoor units. |
| 634 | Pipe sizes are given for indicative purpose, however it has to be selected as per OEM recommendation of the ODU Selected |
| 635 | Liquid line - 3/4\" |
| 636 | Gas line - 1 3/8\" |
| 637 | REFENET JOINTS (SET) |
| 638 | Cable Tray For VRF Copper Piping: |
| 639 | SITC Of Galvanized cable tray suspended from ceiling with ceiling suspenders including G.I. Bolts & Nuts,Etc as required for Supporting / Laying of copper pipes in the cable tray. The colour of cable tray will be decided by the Architect. The cable tray will be provided for better aesthetics, and the Size will be designedin such a way that copper pipes will be routed properly. Further the cable tray will also be used where ever piping\"s are routed even in floor level / wall level etc in toto of the pipe length from start to end and has to be supported properly. |
| 640 | Refrigerant Gas as required for Commissioning (Only when unit is not coming with factory filled) else this can be quoted as Rate only. |
| 641 | Gas Charging and Testing & Commissioning of Condensing units.(Including Nitrogen Pressure testing ,Purging & Vacuumizing) |
| 642 | Rubber pads for out door units |
| 643 | Miscellaneous like Transportation / Scaffolding / Freight, Leading of Materials / Air Balancingetc if any including minor civil works |
| 644 | Comprehensive AMC after Defect Liability period of 2 Years |
| 645 | AMC for 3rd Year |
| 646 | AMC for 4th Year |
| 647 | AMC for 5th Year |
| 648 | AMC for 6th Year |
| 649 | AMC for 7th Year |
| 650 | IMPORTANT NOTES TO BE FOLLOWED BY BIDDER |
| 651 | It is Vendors responsibility to study the drawing and Inspect the site before quoting for the project, and vendors shall satisfy all the design needs required for the project including heat load estimation etc & it will be vendors responsibility in full to provide guarantee for the performance of unit & maintaining temperature at all conditioned space. |
| 652 | It is very important that the vendor shall take approval for all the make / materials etc with COERS / IITM / Architect before procuring and they have to confirm the make to be supplied in the initial stage itself. Bills will not be processed for materials which are not approved by IITM / COERS |
| 653 | All measurement above are indicative and the quantity shall be billed and paid as per actual measurement certified by the Client / Consultant. 2 YEARS Comprehensive warranty to be provided for complete system. |
| 654 | GST % are given as indicative and Vendor shall ensure the correct % while quoting. |
| 655 | Client will provide only one input power supply to the individual Units and at one location. It will be the Vendors responsibility to consider the other requirements including communication / power cables, necessary panels as required for IDU etc as required for running the units. ODU MCCB to be supplied and to connected by HVAC bidder |
| 656 | HVAC vendor shall co ordinate with other vendor\"s (like fire , Electrical etc) and make a provision in their system so that in case of any fire / un even incident, the entire power supply to HVAC shall get disconnected and all the HVAC system supplied by the vendor shall stop on safety. The cost for the system integration including potential free contact provision shall be borne by the HVAC Vendor. In case if cable required then the same shall be quoted additionally after prior approval from consultants / architects (If not considered by electrical vendor). |
| 657 | If any Grill / Diffuser / Ducts etc used other than the size given in BOQ, then SQMTR rate shall be applicable wrt size and gauge thickness and price approval for Non BOQ item shall be received from consultant / architect before proceeding. |
| 658 | In Case if any items are required other than the BOQline item, which may require as per site requirement, then the same shall be quoted, approved from client / consultant and then only it shall be supplied to meet the project requirement. Any testing required at site will be included in bidders scope and no additional payment will be entertained. |
| 659 | Wherever Drain Pump is required for draining the condensate water, the drain pump shall be added to machine cost and the same shall be supplied to site including necessary fittings and connections if not added as a separate item. |
| 660 | Vendor to Provide all Civil Opening Dimension including Duct / FA Fan provision / Fan Openings / Supporting Arrangement detailing etc for fans if required any minor brick wall opening etc as required including plastering shall be considered in the HVAC bidders scope. Civil work must be taken care by specialised civil agency under scope of bidder. |
| 661 | Civil Wall opening requirement marking etc shall lie in the Hvac bidder scope for the ducts / fixing of fans etc. Bidder shall also ensure that proper packing and finishing of walls will be done in co ordination with client. However Civil Pedestals,Wall Opening etc shall be done by client for which bidder to provide detailing. |
| 662 | The Duct routing / sizes shown is for indicative purpose. Powder coating for exposed ducting to be provided as and wherever required and colour to be as per client / architect requirement. Any modification required at site to suit false ceiling height etc shall be done in co ordination with other vendors so that proper height is maintained for other services. No additional cost will be entertained |
| 663 | The bidder has to follow the above important notes , In addition they have to follow the tender specifications given by the client. Whichever specs is stringent will have to be followed by the bidder and the same needto be noted. |
| 664 | IITM 8TH FLOOR LOW SIDE |
| 665 | SITC of RECTANGULAR duct as per SMACNA including all support, necessary fittings, etc as required along with powder coating to meet the colour selected by the architect / client to have a smooth finish. |
| 666 | 24G Sheet |
| 667 | 22G Sheet |
| 668 | 20 G Sheet |
| 669 | 18 G Sheet (Plenum box) |
| 670 | Flexible Ducting to be used for connecting Collar & Grill as applicable as per site condition |
| 671 | 150 mm Dia |
| 672 | 200 mm Dia |
| 673 | Canvas/Damper |
| 674 | Supply & fixing of fire retardant synthetics canvass connection (To Suit) |
| 675 | Supply and fixing ofMouth Damper |
| 676 | Supply and fixing of Volume Control Damper - Manual |
| 677 | Supply of Fresh Air Damper - Manual |
| 678 | Providing Ducting for Fresh air to all the CSU as required along with insulation (Extension Piece if required) |
| 679 | Supply ofFire Dampers as required for return air ducts (Size to suit) and it shall be a fire damper type with all necessaryapprovals obtained as per std. (Preferably Fusible link type) |
| 680 | SITC ofhorizontal continuous grill/diffusers with the following sizes. (Grill Colour shall be meeting as per architect / client requirement). All supply air grill / diffuser shall have a control damper. |
| 681 | Supply Air diffusers / Grill for round duct / rectangular duct as required with dampers |
| 682 | Supply Air Grill With Damper (15⁰ Deflection) |
| 683 | Return Air Grill |
| 684 | 3 Slot Supply Diffuser with Damper |
| 685 | 3 Slot Return Diffuser |
| 686 | Square Diffuser with collar Damper (For Supply) - 150 mm x 150 mm |
| 687 | Square Diffuser (For Return) - 150 mm x 150 mm |
| 688 | Square Diffuser with collar Damper (For Supply) - 225 mm x 225 mm |
| 689 | Square Diffuser (For Return) - 225 mm x 225 mm |
| 690 | Square Diffuser with collar Damper (For Supply) - 300 mm x 300 mm |
| 691 | Square Diffuser (For Return) - 300 mm x 300 mm |
| 692 | Square Diffuser with collar Damper (For Supply) - 375 mm x 375 mm |
| 693 | Square Diffuser (For Return) - 375 mm x 375 mm |
| 694 | VARIABLE AIR VOLUME BOX - VAV : |
| 695 | Supply, Installation, testing and commissioning of VAV boxes.VAV box shall be with Acoustically insulated for low noiseoperation , Mechanically sealed. Occupational sensor / Thermostats etc as required will be a part of VAV supply and the same shall be included in the price quoted in VAV. Interconnection including cables for VAV, Thermostat, Occupational sensor etc or as required in complete should be a part of the VAV supply. The VAV shall be controlled by the panel (Panel & required Cable cost) to be considered by the bidder and VAV shall be controlled by a 24 V circuit. All step down arrangement shall be considered in the VAV panel which will be fixed in theCSU room. Integration of VAV to CSU/AHU VFD will be in HVAC Bidder scope. Any cost foot the same shall also be considered by the bidder. |
| 696 | CSU 01 - 16.0 TR |
| 697 | VAV- 275 CFM ( Ideation Room ) |
| 698 | VAV- 2300 CFM ( Work Station ) |
| 699 | VAV- 3350 CFM ( Work Station ) |
| 700 | CSU 02 - 16.0 TR |
| 701 | VAV- 330 CFM ( Disc.Rooms 1 - 4 ) |
| 702 | VAV- 350 CFM ( Disc.Room 5 ) |
| 703 | VAV- 450 CFM ( 4 Pax ) |
| 704 | VAV- 730 CFM ( Admin Room ) |
| 705 | VAV- 2625 CFM ( Work Station ) |
| 706 | AHU - 20.0 TR |
| 707 | VAV- 950 CFM ( Conference Room 1 ) |
| 708 | VAV- 1000 CFM ( Conference Room 2 &3 ) |
| 709 | VAV- 1300 CFM ( Executive Cabin) |
| 710 | VAV- 2450 CFM ( Lab Simulation Room & Server Room ) |
| 711 | VAV Electrical Control Panel along with necessary cabling etc as required for controlling respective VAV with CSU/AHU as per drawing and its interconnecting cable for VFD controlling, Occupation sensor etc in complete. |
| 712 | INSULATION |
| 713 | Acoustic Insulation |
| 714 | Supply & fixing of acoustic insulation with 10 mm thick open cell nitrile rubber |
| 715 | Rectangular Duct or as required |
| 716 | Thermal Insulation |
| 717 | Thermal insulation with min 13mm thick closed cell nitrile rubber with a wrap over the ducting as required for rectangular ducting. (In few cases inside acoustic insulation will also be there and bidder to consider the thermal insulation of ducts over the above) |
| 718 | Rectangular Duct or as required |
| 719 | MSStructures for support (Except Ducting as Duct Support to be considered in ducting works) |
| 720 | Drain Line (UPVC including all joints / fittings / bends / pasting etc in total) along with required Insulation and the same to be connected to the nearest drain line provision, Drain line shall be insulated properly to avoid any sweating and to be connected to the nearest drain line available available) - This includes all the indoor units of the project in toto including VRF - AHU / Chilled water indoor units etc). Vendor to consider complete drain line of the project in total. |
| 721 | Miscellaneous like transportation / supervision / Minor Civil Work etc |
| 722 | IMPORTANT NOTES : |
| 723 | It is Vendors responsibility to study the drawing and Inspect the site before quoting for the project. The vendor shall verify the heat load, satisfy themselves and shall provide guarantee for the project executed by them and ensure that the room temp is maintained within 23+or-1 Deg C with 55%RH. |
| 724 | It is very important that the vendor shall take approval for all the make / materials etc with COERS / IITM / Architect before procuring and they have to confirm the make to be supplied in the initial stage itself. Bills will not be processed for materials which are not approved by IITM / COERS |
| 725 | All measurement above are indicative and the quantity shall be billed and paid on actual measurement basis |
| 726 | GST % are given as indicative and Vendor shall ensure the correct % while quoting |
| 727 | Electrical cables i.e. All Power Cables between IDU s and ODUs if any, Main Incoming Panel required for the Units, Incoming Cables etc if any are not covered in this pricing |
| 728 | The above BOQ is based on the drawing we submitted and is indicative which is bound to change as it is given for reference purpose. |
| 729 | RA Grill shall be fitted as per site requirement so as to reduce the noise from CSU. Bidder to ensure the same |
| 730 | VAV - VFD Communication scope shall be with low side Bidder. However any requirement on high side (CSU Supply) shall be indicated by low side bidder on case to case basis during finalisation. |
| 731 | All control cable and Power cable required for VAV shall be in HVAC low side Supplier scope |
| 732 | For Return Air, in Meeting Rooms etc, if required Z type / U Tupe attenuator along with grills to be considered. GI sheet with acoustic insulation measurement shall be considered in Sqmtr and payment will be considered accordingly in sq. mtr s, Bidders to ensure RA boxing is done for individual areas / Units to avoid any mixing and also ensure sufficient return air is provided to all the units for better functioning. |
| 733 | CHW is assumed to be Supplied to CSU/AHU at 8 DEG C, Bidder to verify the same. |
| 734 | SA Grill / Diffuser will have a control damper near the grill and wherever required the same shall be provided for RA grill / diffuser also as the case may be. |
| 735 | Vendor to Provide all Civil Opening Dimension including Duct / FA Fan provision / Fan Openings / Supporting Arrangement detailing etc for fans if required any minor brick wall opening etc as required including plastering shall be considered in the HVAC bidders scope |
| 736 | Bidder to provide NO/NC Contact interlock for all the CSU/AHU Units supplied which will be linked to FAS so that in case of any FAS, the unit shall be switched off. Requisite interlocking cables etc and co ordination with FAS vendor shall be done by hvac bidder. Cost for interlock shall be considered by HVAC Bidder including cables etc |
| 737 | The bidder has to follow the above important notes , In addition they have to follow the tender specifications given by the client. Whichever specs is stringent will have to be followed by the bidder and the same needto be noted. |
| 738 | CHILLED WATER PIPING : |
| 739 | Supply and installationincluding supports, Saddles fittings fixing of all necessary accessories as per IS 1239/IS 3589 |
| 740 | CLASS C PIPES |
| 741 | Ø 75 mm Dia |
| 742 | Ø 40 mm Dia |
| 743 | Ø 32 mm Dia |
| 744 | Ø 25 mm Dia |
| 745 | SUB HEADING - CHILLED WATER PIPE INSULATION - Including Bends/Valves etc |
| 746 | Insulation shall be of min 38 mm Thick and of density 60Kg/Cumtr (Thermal conductivity of less than 0.035 W/(m.K) along with Aluminium cladding of around 0.7 mm thick over the nitrile rubber / equivalent. Insulation shall be done with class O material and bidder to follow the latest standard of EN 14706,77,14304,12667/ BS 476. The price quoted below should be inclusive of bends / valve insulation etc considered in Piping |
| 747 | Ø 75 mm Dia |
| 748 | Ø 40 mm Dia |
| 749 | Ø 32 mm Dia |
| 750 | Ø 25 mm Dia |
| 751 | SUB HEADING VALVES & INSTRUMENTS |
| 752 | Supply / Installation / testing Commissioning of the following: |
| 753 | BUTTER FLY VALVE / BALL VALVE To SUIT |
| 754 | Ball Valve or Butterfly valve to suit requisite size (up to 50mm preferably Ball valve can be used) having internally moulded rubber lined body, EPDM Seal material with Pressure rating PN 10, Class # 150 Flanges, ANSI, in position complete with flanges, bolts, nuts, gaskets etc with insulation(Note Valves to be provided with spool pieces on either side for easy connection of pipe), wherever maintenance is required for easy cleaning and removal of pipes. Less than 50mm Dia, Ball valve can also be provided with PN 10 rating minimum or with increased rating as required at site. |
| 755 | (Ø 75) mm Size For Headers,CSU & FM Connection |
| 756 | (Ø 40) mm Size For Sub Headers |
| 757 | (Ø 32) mm Size For Sub Headers |
| 758 | (Ø 25) mm Size For HWM & Cassette Connection |
| 759 | Balancing Valve for Flow Control with pressure rating of class # 150, ANSI & insulation in position complete with flanges, bolts, nuts, gaskets etc for Outlet line . |
| 760 | (Ø 75) mm Size For Headers |
| 761 | 2 Way 24 V Pressure Independent valve with Actuator Motor Balancingcum flow control measurement Valve (Normally close with spring return) for CSU/AHU/Cassette/HWMreturn line of chilled water system (Heavy duty Class # 150, cast iron Body, suitable transformers, controllers etc as required along with complete insulation). The valve shall be of EPIV type with flow measurement and the cables required for measuring and transmitting to IITM BMS for energy monitoring etc will be in Bidders scope. |
| 762 | (Ø 75) mm Size For CSU\"s |
| 763 | (Ø 25) mm Size For HWM\"s & Cassette\"s |
| 764 | Mild Steel Y Type Strainer to suit for CSU/AHU/Cassette/HWMWith Stainless Steel Filter Screen of 3- 5mm Perforation X 24G so as to suit. Flanged End Connection As Per BS 10 with Pressure rating of Class # 150, ANSI & insulation as per specifications . |
| 765 | (Ø 75) mm Size For CSU\"s |
| 766 | (Ø 25) mm Size For HWM\"s & Cassette\"s |
| 767 | SUB HEADER - PRESSURE GAUGE & TEMPERATURE GAUGE (CHILLED WATER) |
| 768 | Supply, installation, testing and Commissioning of 150 mm Dia dial type pressure gauge in the water lines with brass ball valve of suitable Dia, siphon, SS tubing, socket and having range (0-10 bar) as required. |
| 769 | Supply, installation, testing and Commissioning of Industrial dial type (150mm Dia ) thermometers in thechilled water lines(Range should be optimistically selected) |
| 770 | FLOW METER : (Make Shenitech) |
| 771 | Chilled water flow meter for BTU (1 no for each Header) to suit. The flow meter shall be capable to interlink with the existing BMS system and should support measurement of Energy (Preferably In TR Consumed Per HR or in KWH of cooling) and the same shall be recorded and stored in BMS, Communication Protocol - Modbus / Cables , I/O, Termination Bidder scope. Cost for the same to be considered by bidder. |
| 772 | MSStructures for support |
| 773 | Miscellaneous like transportation of units / Supervision of units erection / Minor Civil works etc |
| 774 | IMPORTANT NOTES : |
| 775 | It is Vendors responsibility to study the drawing and Inspect the site before quoting for the project, The bidder shall guarantee for the performance in toto. Any coordination between vendors as required for completing the work successfully will be in HVAC Bidder scope. All materials supplied shall be with IITM Approved make only and vendor to co ordinate with client for getting approval from IITM before supplying the same. |
| 776 | It is very important that the vendor shall take approval for all the make / materials etc with COERS / IITM / Architect before procuring and they have to confirm the make to be supplied in the initial stage itself. Bills will not be processed for materials which are not approved by IITM / COERS. Any testing at site required to prove the quality of work must be bidder scope. |
| 777 | All measurement above are indicative and the quantity shall be billed and paid on actual measurement basis and any items as required at site all be quoted by bidder and shall be claimed extra at actuals at the approval of architect / client. Any Minor civil work like breaking wall / plastering work etc shall be considered by the bidder in their scope and cost to be included in Miscellaneous works. All Civil work must be taken care by specialised civil agency under scope of bidder. |
| 778 | GST % are given as indicative and Vendor shall ensure the correct % while quoting |
| 779 | The above BOQ is based on the drawing we submitted and is indicative which is bound to change as it is given for reference purpose. |
| 780 | All control cable and Power cable required for Flow Meter shall be in HVAC bidder scope and the same need to be accounted in the above pricing. Make as per the approval RP. |
| 781 | SITC of requisite Chilled water supply and return along with the valves, insulation, strainers etc as required for the system |
| 782 | Flow Meter shall be integrated to the existing BMS for Energy Monitoring, Bidder to include the cost for the same. |
| 783 | Flow meter for individual units are mandatory to measure the energy monitoring. Bidder to consider a separate flow meter or it can be integrated with 2 way control valve as required. The data from flow meter to be transferred to the BMS by the bidder for which all suitable cables, controls etc to be considered by the bidder. |
| 784 | VALVES / INSTRUMENTS etc shall be insulated as required toavoid any sweating and the cost quoted above shall be inclusive of the insulation cost |
| 785 | The bidder has to follow the above important notes , In addition they have to follow the tender specifications given by the client. Whichever specs is stringent will have to be followed by the bidder and the same needto be noted. |
| 786 | Plumbing BOQ |
| 787 | Providing / Modification & Fixing concealed / Open UPVC pipes as the case may be , of approved make with Astral / Asirvad / Supreme / Equivalent make including all fittings like coupling, union, MTF, T Joints, Elbows, solvents for pasting / joining etc at all levels including making holes in walls / floor, making them good withcutting, threading, joining & sealing the pipes with Teflon thread sealing tape, hydraulic testing etc. complete as specified & directed.Min design pressure shall be of 10 Kg/Cmsq or to suit site condition. (Considered for Rest room & Canteen Line as required). Any support required shall also be considered by bidder in their cost. |
| 788 | 25 mm. dia. |
| 789 | 32 mm. dia. |
| 790 | 50 mm Dia |
| 791 | Providing & fixing CPVC hot water supply pipe from geyser outlet or as required, including all specials (elbow, tee, union), clamps, solvent cement jointing, testing & commissioning complete. (Considered for hot water supply line). Work should be completed in toto.Min design pressure shall be of 10 Kg/Cmsq or to suit site condition |
| 792 | 15 mm. Dia or to suit |
| 793 | Providing and fixing of Stop Valve of Brass / Stainless Steel including necessary socket union nut and complete fittings required for gate valve / ball valve type of following size. Approved make orEqvt or as approved by IITM) |
| 794 | 25 mm |
| 795 | 32 mm |
| 796 | 50 mm |
| 797 | Providing / Modification and fixing of Mechanical Water Flow meter Sant / Kranti/ Eqvt make with strainer of following sizes including necessary socket union nut, mating flanges as required in complete (Optional but price is mandatory). BMS integration through Modbus/ or as per existing system of connecting flow meter on water consumption along with all requisite cables etc will be considered in bidders scope |
| 798 | SITC ofcomplete shower point including hot & cold water supply lines with 2 no\"s Mixingvalves (15 mm), concealed shower mixer/diverter, overhead shower with arm, all pipe fittings, supports, chase cutting/making good, accessories, pressure testing & commissioning. |
| 799 | Providing and fixing of wash basin (Design as per Arch Selection) including all civil work and fittings as required to complete the work in full. The selection will be as per architect requirement and make will be of Approved make Eqvt. ( 4 Nos for Canteen). Each Wash Basin will have a Angle valve / CE Infra Red Basin Tap along with its flexible / fixed connecting pipes as required. Drain line will be of similar UPVC pipe with 10 Bar min pressure and it has to be considered along with all fittings including bends / elbows / T joints / Solvent pasting etc. Wash basin drain line in toto including any fittings / connections etc as required to be considered and the same to be connected to the solo lift sump collection tank. Cost to be considered in this line item. |
| 800 | Counter Top Basin -Approved make |
| 801 | Bowl Kitchen Sink - Approved Make : (C857381) |
| 802 | Supplying and fixing of Angle Valves to all the wash basin inlet connection with all necessary fittings. Approved make or Eqvt. |
| 803 | Supplying / Fixing of Essential Soap Dispenser with Holder of approved make or Eqvt. |
| 804 | Waste Trap Basin as required with Cosmo / Grohe Make of min 1 1/4 inch size or as required. approved make or Eqvt. |
| 805 | SITC of minimum 50 litres HDPE or (to suit) waste water collection tank. This tank should have provision for regular cleaning along with high and low level sensors. This sensor will be connected to the Solo lift pump where in the pump will be operated based on the levels. Required control panel/level switch/sensors / auto mode / manual mode operation provision etc shall be provided in the control panel with earthing / change over switch for pumps etcto be considered by bidder. The complete set has be supplied by the bidder in toto and any additional requisite materials like cables etc as required for operating and controlling the pumps shall be considered by the bidder in totality for effective operation. )Overall cost for the above to be quoted) |
| 806 | SITC with all necessary fittings of Solo Lift / SFA Pump capable to deliver 100 Lpm at 15 Meter head (or as required) including all accessories like NRV, Valves etc. The pump outlet will be connected to the main header drain at corridor which will lead to the shaft drain. (One no for Canteen with standby). In case natural drain provision is available this item may be considered as optional. Electrical panel as required for the pump along with its requisite control connection to be considered by the bidder. |
| 807 | Drain Line Modification work for the above work in complete along with modification of inspection chamber work as required for Canteen (In case of floor drain is available). To be quoted as an optional item. |
| 808 | Miscellaneous like Shifting, Transporting, Demolitions and clearing works, Civil works, Provision of drain gate, Flexible drain Line as required, Channel drain etc, as and wherever applicable. |
| 809 | NOTE: |
| 810 | Vendor shall inspect the site and ensure that they are completely clear on the job scope and specification. It is very important that the vendor shall take approval for all the make / materials etc with COERS / IITM / Architect before procuring and they have to confirm the model number of the fittings etc to be supplied in the initial stage itself. Site inspection as required shall be carried out by the bidder as required and bidder to satisfy themselves before quoting on all the makes etc. |
| 811 | All SW Drain Pipe shall be capable to withstand a minimum pressure of 10Kg/Cmsq / Fresh water Pipe shall be capable of 10 KG/CmSq or as required but min 10 Kg/CM sq. to be maintained. |
| 812 | Price will be paid as per actual measurement basis at site and for the actual work done. No extra payment for any reason will be entertained without client / architect approval. |
| 813 | The above BOQ indicates few components as selected by Architect / Client. For all the product, it is the bidders responsibility to get all part number / model numbers approved for this project prior to supply along with the models. |
| 814 | Complete Civil work along with any accessories like union / bends / couplings / Paste including any other fittings as required etcto complete the above work shall be considered by the bidder in full and job to be quoted accordingly. No separate price shall be given for fitting items. Any additional requirement as per site condition shall also be mentioned and quoted by the bidder so that the work is completed in full by the bidder. Wall chasing and rectification of blockworks and plastering with Civil work must be taken care by specialised civil agency under the scope of bidder for total works mentioned above. Any water proofing and finishing works with coordination with civil vendor to be considered by bidder. No additional cost will be paid for the same and bidder to include in above price for all the scope mentioned |
| 815 | Any items which are not mentioned in BOQ and required at site shall be provided by vendor on client / Consultant approval only. This must be ensured by bidder during bidding stage itself . Only exceptional cases allowed as per the tender condition. |
| 816 | The drain pipes shall be with air tight / leak proof joints and the same shall be connected up to to the shaft line with required sloping to meet standards. For Canteen it is assumed that a drain pump will be provided with std by along with all fittings / pipes etc and the same shall be connected to the shaft line min header drain. In case if drain at floor level is available, then same shall be used and the other line item indicated will be only a RO item.Inspection points as required to be provided in critical bends for easy maintenance in future. |
| 817 | Any civil work like Breaking/Plastering Etc Shall be considered by the bidder. Cost to be included in above price. |
| 818 | The bidder has to follow the above important notes , In addition they have to follow the tender specifications given by the client. Whichever specs is stringent will have to be followed by the bidder and the same needto be noted. |
| 819 | FA BOQ |
| 820 | Scope includes Testing and Commissioning of system with Preparation of \"As Fitted Drawings\" and submission of 3 Sets of hard copies and 1 Set of soft copy. |
| 821 | Erection Cost shall be included with all necessary accessories required for Erection in all aspects should be included in the Offer. |
| 822 | If any item is missed out, the tenderer is duty bound to quote for the same. The additional items shall be listed and quoted as an attachment with a covering note. Any claim for omissions after the contract is awarded shall be rejected. |
| 823 | Successful bidder to prepare the shop drawingsfor Client / Architect approval before deliver the materials and execute the works at site |
| 824 | Scope includes integration with Public Address System, Access Control Door System and Fire Fighting System for Flow Switch |
| 825 | Fire Detection Alarm System as per IS 2189:2008 |
| 826 | The scope of this section covers the design and supply and Erection of the following as per technical specifications and data sheets . |
| 827 | Note: Shop drawings to be prepared for approval before execute the work and order the materials |
| 828 | Supplying and fixing of 1 Loop Addressable analogue panel complete with battery charger, SMF battery, Auto dialler, Network Card etc located Near Reception Area, 8th Floor Level |
| 829 | Supplying and fixing of Analogue Addressable Multi technology - Optical + Heat Smoke Detectors |
| 830 | Supplying and fixing of Analogue addressable Short circuit isolators |
| 831 | Supplying and fixing of Analogue addressable Manual Pull / Call Points |
| 832 | Supplying and fixing of Analogue addressable Loop sounders or ordinary loop sounders with control modules. The cost of Control Module to be included |
| 833 | Supplying and fixing of Analogue Addressable Control Modules for HVAC, Access Control Doors, Public Address System and Spares |
| 834 | Supplying and fixing of Input Modules required for Sprinkler flow Switches |
| 835 | Supplying and fixing of Response Indicators |
| 836 | Supplying and fixing of Fully featured Voice alarm / announce system integrated with the Fire alarm system and communicating with the PA system for broad casting evacuation procedures during alarm etc. |
| 837 | Panic bar with microswitch and sounder to be connected to intruder alarm panel - Panic device shall be of DORMA make PHA 2000or equivalent, single point locking with external trim with PHT 3905 door handle or equivalent to be approved for singe shutter doors. |
| 838 | Note: If PC will be given by Client and Fire Alarm System Graphic Software installation will be done by successful vendor at free of cost |
| 839 | Cabling Works |
| 840 | Care has been taken in the preparation of this to take care of the different types of cables that may be required by vendors. If in case over and above this any other type of cable is necessary the same shall be indicated at the time of initial offer itself.Offered rates are to be inclusive all works that maybe required for cabling work like making holes and making good the damage, chasing walls if necessary, cable clamps and consumables. Only cable trays will be provided by other agency. |
| 841 | Supplying, Laying 2 Core x 1.5 Sq.MM twisted multi strand copper conductors, PVC -FRLS insulated overall braided shielded armoured PVC - FRLS sheathed cables. |
| 842 | 2 Core Polycab |
| 843 | Glands and lugs suitable for 2 Core cables |
| 844 | Miscellaneous Works |
| 845 | Integration the Proposed Fire Detection Alarm System Panel at 8th Floor Level and Existing Fire Detection Alarm Panel at Ground Floor provided by base builder for common areas |
| 846 | Integration of Access Control and Public Address System with Fire Detection Alarm System with all necessary accessories required for Erection in all aspects should be included in the Offer. |
| 847 | PA BOQ |
| 848 | Scope includes Testing and Commissioning of system with Preparation of \"As Fitted Drawings\" and submission of 3 Sets of hard copies and 1 Set of soft copy. |
| 849 | Erection Cost shall be included with all necessary accessories required for Erection in all aspects should be included in the Offer. |
| 850 | If any item is missed out, the tenderer is duty bound to quote for the same. The additional items shall be listed and quoted as an attachment with a covering note. Any claim for omissions after the contract is awarded shall be rejected. |
| 851 | Successful bidder to prepare the shop drawingsfor Client / Architect approval before deliver the materials and execute the works at site |
| 852 | Public Address System |
| 853 | Approved Makeor equivalent |
| 854 | The scope of this section covers the design and supply of the following as per technical specifications and data sheets. |
| 855 | Supplying and fixing of Recessed / Surface mounting Box type indoor speakers - 15Watts RMS with all necessary accessories required for Erection in all aspects should be included in the Offer. |
| 856 | Supplying and fixing of Recessed mounting indoor speakers - 6Watts RMS with ceiling ring suitable to the Architect\"s choice with all necessary accessories required for Erection in all aspects should be included in the Offer. |
| 857 | Supplying and fixing of Surface mounting indoor speakers - 6Watts RMS suitable with all necessary accessories required for Erection in all aspects should be included in the Offer. |
| 858 | Supplying and fixing of Central working and standby amplifiers suitable for the speaker output load plus 20% spare capacity as specified |
| 859 | Supplying and fixing of Central electronic exchange cabinet and Master control station at inside Public Address System Rack near Reception |
| 860 | Supplying and fixing of Gooseneck microphones with pre amplifiers for making announcements at Reception Table. The zone selection provision shall be made available at Reception Table and the cost for the same to be included. The minimum number of Zone shall be 4 |
| 861 | Supplying, fixing Desk Top annocement Micro Phone at Reception Table |
| 862 | Supplying, fixing of player with DVD, Wi-Fi, USB Port devices etc |
| 863 | Supplying and fixing of TR91H Premium True Diversity UHF Wireless Microphone System with all necessary accessories required for Erection in all aspects should be included in the Offer. |
| 864 | Supply and fixing of 15U Wall mounted rack with glass/ metal front door, steel rear door, power supply and all other accessories required for Erection in all aspects should be included in the Offer. |
| 865 | Cabling Works |
| 866 | Make: Finolex, Delton, RR Kabel, Lapp Kabel, Unifilex, Telifex,or equivalent |
| 867 | Care has been taken in the preparation of this to take care of the different types of cables that may be required by vendors. If in case over and above this any other type of cable is necessary the same shall be indicated at the time of initial offer itself.Offered rates are to be inclusive all works that maybe required for cabling work like making holes and making good the damage, chasing walls if necessary, cable clamps and consumables. Only cable trays will be provided by other agency. |
| 868 | Supplying 2Core x 1.0 Sq.MM twisted multi strand tinned copper conductors, PVCFRLS insulated overall shielded armoured / Steel braided / Un armoured and PVC FRLS sheathed cables. |
| 869 | Armoured / Steel braided cables |
| 870 | 2Core Cable |
| 871 | Glands and lugs suitable for 2Core cables |
| 872 | Miscellaneous Works |
| 873 | Supplying, laying 20mm. Dia PVC Flexible hose in ceiling/Concealed in wall / partitions with necessary clamps, screws etc. |
| 874 | CCTV BOQ |
| 875 | Scope includes Testing and Commissioning of system with Preparation of \"As Fitted Drawings\" and submission of 3 Sets of hard copies and 1 Set of soft copy. |
| 876 | Erection Cost shall be included with all necessary accessories required for Erection in all aspects should be included in the Offer. |
| 877 | If any item is missed out, the tenderer is duty bound to quote for the same. The additional items shall be listed and quoted as an attachment with a covering note. Any claim for omissions after the contract is awarded shall be rejected. |
| 878 | Successful bidder to prepare the shop drawingsfor Client / Architect approval before deliver the materials and execute the works at site.Note : The location ofequiments to be done as per consultation with client. |
| 879 | IP Based CCTV System - Project series from Approved makes of materials |
| 880 | Note: Before delivery of materials at site, the successful Vendor to submit their Standardisation Testing and Quality Certification, Under MeitY, Government of India for their quoted Cameras |
| 881 | Note: IP Cameras required as per attached camera location layouts, the cameras shall be cover the entire premises. (Vision range to be marked in the drawing for approval before execute the work and order the materials) |
| 882 | Supply, installation, testing and commissioning IP Based CCTV System with the following. Please quote the necessary quantities against each items and also add any items required to complete the system |
| 883 | Cameras |
| 884 | Supply and Installation of 5MP Full HD IR fixed Dome Camera with 1/3\" Progressive scan CMOS not less than 5MP Vari Focul lens of 2.8mm (Lens shall be to suit site conditions) with H.265+ Compression maximum distance of 30Mtrs IR Range, Digital WDR, 3D DNR, night vision, 25/30fps, Suitable for PoE / 12Volts DC |
| 885 | Networkable Video Recorder |
| 886 | Note: The NVR should have a storage for 30Days with 25 Frames per second and event based recording |
| 887 | Supply and Installation of 16 Channel IP Based Networkable Video Recorder configurable with H.265+ Compression. |
| 888 | Supply and Installation of 32 Channel IP Based Networkable Video Recorder configurable with H.265+ Compression. |
| 889 | Supply and Installation of 6TB Surveillance HDD Segate |
| 890 | Supply and Installation of 42\" LED Large Format Display with all necessary mounting kits and necessary HDMI Cables for connecting the display with NVR |
| 891 | Network Passive Components |
| 892 | Supplying, erecting, connecting and commissioning of 10/100/1000 24 Port switch with 4 SFP uplink ports Gigabit Managed POE Switch suitable power range with 20% extra |
| 893 | Supplying, erecting, connecting and commissioning of 24Port Cat 6, Angular Unloaded Jack Panel - Blue Colour Outlets |
| 894 | Supplying, erecting, connecting and commissioning of Cat 6, RJ 45 Information Outlets at Jack panel end |
| 895 | Supplying, erecting, connecting and commissioning of Cat 6, 7\"Lockable Type Patch Chord at Rack Side - Blue Colour |
| 896 | Supplying, erecting, connecting and commissioning of Cat 6, RJ 45 Connector at Field End |
| 897 | Supplying, fixing weather proof back box with top cover |
| 898 | Supplying, fixing of Height adjustable SS Supporting materials for fixing Camera |
| 899 | Supplying and laying the Cat 6 UTP LSZH Giga speed unshielded twisted pair cable with 23 AWG Solid copper conductors in already laid PVC Conduits / Aluminium Raceways at Field Side (305.0Mtrs Per Box) |
| 900 | Note: Care shall be taken in pulling the cables in to the conduits. The conduits shall be thoroughly cleaned of moisture, dust, dirt or any obstruction by forcing compressed air through the conduits |
| 901 | ACCESS CONTROLBOQ |
| 902 | Scope includes Testing and Commissioning of system with Preparation of \"As Fitted Drawings\" and submission of 3 Sets of hard copies and 1 Set of soft copy. |
| 903 | Erection Cost shall be included with all necessary accessories required for Erection in all aspects should be included in the Offer. |
| 904 | If any item is missed out, the tenderer is duty bound to quote for the same. The additional items shall be listed and quoted as an attachment with a covering note. Any claim for omissions after the contract is awarded shall be rejected. |
| 905 | Successful bidder to prepare the shop drawingsfor Client / Architect approval before deliver the materials and execute the works at siteNote : The location ofequiments to be done as per consultation with client. |
| 906 | Access Control System |
| 907 | Approved Make orequivalent |
| 908 | The scope of this section covers the design and supply of the following as per technical specifications and data sheets. Facility shall be made in the system to provide for door open too long alarms with the help of magnetic contacts and buzzers. |
| 909 | The requirements for access control system are as follows: a.Each and every door shall have an Entry and Exit with Proximity Card Reader with anti-pass back enabled, magnetic contact and alarm.b.The total users are about 150 to 200Nosc.All doors to have on the inside emergency push button for manually opening the doors in case of an emergency. This push button shall be housed in a glass break unit in close to the proximity exit card reader. |
| 910 | Networkable Single / Double Door Controller capable of controlling entry and exit of door with TCP/IP Connectivity, PSU and Battery Back up For Biometric Reader and Proximity Card Reader |
| 911 | Two Door Controller |
| 912 | Supplying, fixing, connecting and Commissiong Biometric system - Face Recognition Reader with Proximity Card and Numerical Key Pad Lock Reader for IN and OUT Purpose as well as Time and Attendance. |
| 913 | Push switch with mounting box for Out Purpose |
| 914 | Blank high definition proximity Cards - compatible with nylon neck lanyard with nickel-plated steel swivel hook and rigid plastic / vinylcard holder |
| 915 | Electric Strike latch |
| 916 | Flush mounting Electromagnetic lock |
| 917 | Green break glass units for access control emergency door release Exit request push button specified for fire alarm system but non addressable type |
| 918 | Buzzer type Alarm |
| 919 | Magnetic contact / switch |
| 920 | Security management software |
| 921 | Time and Attendance Software are required to print all the reports as per client requirement |
| 922 | Cabling Work |
| 923 | Approved Makeor equivalent |
| 924 | Make - Low Voltage System : Amp |
| 925 | Care has been taken in the preparation of this to take care of the different types of cables that may be required by vendors.If in case over and above this any other type of cable is necessary the same shall be indicated at the time of initial offer itself.Offered rates are to be inclusive all works that maybe required for cabling work like making holes and making good the damage, chasing walls if necessary, cable clamps and consumables.Only cable trays will be provided by other agency. |
| 926 | ( Cable Sizes to be mentioned by respective vendor, Please give rate for Armoured cable) |
| 927 | Note: All Electricals cable shall be FRLS and Low Voltage Cables shall be Low Smoke Zero Halogen |
| 928 | From Control Panel to Control Panel. (Assuming all control panels located at centralized locations) |
| 929 | Form Door Control Panel to Reader |
| 930 | From Door Control Panel to EM Lock |
| 931 | From Controller to BUZZER(2C) |
| 932 | From Controller to Door Position Sensor(2C) |
| 933 | Glands & lugs suitable for above cable |
| 934 | Powder coated box 12\"x12\"x2\" with 12 way ELMEX type connectors on DIN rail for terminating the above mentioned cables. The box shall have a openable cover on four screws, gland plates on all four sides. |
| 935 | Suitable back box only to be mounted on wall, partition, etc. for access control reader. The box to be of similar make as the switch socket accessories or powder coated as required. |
| 936 | Structural Supports |
| 937 | Supply of structural steel sections for fabrication of support along the wall/roof 25x25x3mm, 50x50x6mmangles, 100x50x6mm C channels etc along with all the hardware required for fixing, grouting, one coat of red oxide and two coats of synthetic paint. |
| 938 | Miscellaneous Works |
| 939 | Integration of Access Control and Fire Alarm System. |
| 940 | EXIT SIGNAGESBOQ |
| 941 | If any item is missed out, the tenderer is duty bound to quote for the same. The additional items shall be listed and quoted as an attachment with a covering note. Any claim for ommissions after the contract is awarded shall be rejected. |
| 942 | Scope includes Design, Material Supply, Testing and Commissioning of system with Preparation of \"As Fitted Drawings\" and submission of 3 Sets of hard copies and 1 Set of soft copy. |
| 943 | Erection Cost shall be included with all necessary accessories required for Erection in all aspects should be included in the Offer. |
| 944 | Exit signage |
| 945 | Emergency Exit (300mmx150mm single side) Auto Glow Type |
| 946 | Fire Exit (300mmx150mm single side) Auto Glow Type |
| 947 | Exit (300mmx150mm single side) Auto Glow Type |
| 948 | Manual Call Point (300mmx150mm single side) Auto Glow Type |
| 949 | Fire Exit Direction (300mmx150mm double side) Auto Glow Type |
| 950 | Evacuation Plan with Auto Glow |
| 951 | In Case of Fire, Use Staircase unless instructed otherwise 200mm x 300mm Non Glow |
| 952 | SPRINKLER BOQ |
| 953 | SprinklerSystem |
| 954 | Supplying, installing, Modifying as required, testing and commissioningof M.S. Black ERW Heavy grade (C class) Pipes confirming toIS 1239 Pt - I Heavy grade with painting, suitable type of supports ( for above 50 mm Dia, shall be fabricated by M.S. Channel / Angle / Flats etc), anchor fasteners, bolts nuts , clamps, \"U\" bolts, Malleable specials such as Reducers, Tees, elbows, flanges. Including cutting, Welding, fixing in / on ceiling by using suitable supports etc, as per drawings. The quoted rate shall also include for chasing / chipping walls, making bore holes in wallsand making them good with filler material and finished in cement mortar etc. complete. Painting of pipe to include proper preparation and priming and 2 coats of paint. Supports to be painted in factory itself. Necessary protection of other vendor works and existing infra during fabrication , weiling and painting to be considered by bidders quoting . |
| 955 | SITC of Sprinkler line withsprinklers as per required no\"s preferably as indicated in the drawing. The price quoted shall be inclusive of all works like welding, shifting, supplying header pipes etc and to complete the work in full. |
| 956 | 80 mm nominal Dia |
| 957 | 65 mm nominal Dia |
| 958 | 50 mm nominal Dia |
| 959 | 32 mm nominal Dia |
| 960 | 25 mm nominal Dia |
| 961 | BUTTERFLY VALVE |
| 962 | Supplying, Installing, testing and commissioning CI butterfly valves as per BS 5155 ( PN 16) slim seal standard lever operated type with required flanges, nuts, bolts etc. complete. |
| 963 | 80 mm Dia |
| 964 | FLOW SWITCH |
| 965 | Flow switches for sprinkler system piping. Flow switch shall have a paddle made of flexible material of the width to fit within the pipe bore. The terminal box shall be mounted over the paddle/ pipe through a connecting socket. The switch shall be potential free in either NO or NC position as required. The switch shall be able to trip and make/ break contact on the operation of a sprinkler head. The terminal box shall have connections for wiring to the Fire alarm panel. The seat shall be of stainless steel. The control wiring to BMS from flow switch as required along with communication to be considered by Bidder in the switch cost itself. |
| 966 | The flow switch shall work at a minimum flow rate of 40 lpm. Further, it shall have a \"Retard\" to compensate for line leakage or intermittent flows. It shall be UL / FM approved make for sprinkler system operation. Existing Flow rates and pressure of the existing supply to be ensured by bidder during site visit before quoting . |
| 967 | 80 mm Dia to Suit |
| 968 | BALL VALVE |
| 969 | Supplying, installing, testing and commissioning of Gun metal chrome finished Ball valveswith fittings of screwed end type. |
| 970 | 25 mm Dia (For drain) |
| 971 | 50 mm Dia (For Flushing) |
| 972 | 65 mm Dia (For Flushing) |
| 973 | FLEXIBLE PIPE |
| 974 | Stainless steel corrugated flexible pipe(hose) for dropping sprinklers below false ceiling, pipe shall be UL Listed ,16 bar pressure rating and 25 mm Dia with supports, fasteners, union / reducer collar, clamps etc. as required. (Rate Only) |
| 975 | 1500 mm length |
| 976 | 1000 mm length |
| 977 | 700 mm length |
| 978 | BULB TYPE |
| 979 | Supplying, installing, testing and commissioning conventional Sprinkler quartzoid bulb type with 15mm screwed end connection of 68 deg. C. temperature rating, K 80 and orifice shall not be less than 6mm.Sprinklers shall be UL Listed / FM approved with Chrome finished. |
| 980 | Pendent sprinkler 68°c |
| 981 | Concealed type sprinkler 68°c |
| 982 | ROSETTE PLATE |
| 983 | Supply & fixing of approved type rosette plates (Recessed type, in two piece) for Sprinklers in cornice area. |
| 984 | The Rosette shall be fabricated by M.S. plate of 2mm thick and the finish shall be powder coated and colour shall be as approved by architects / clients. (Rate Only) |
| 985 | Supplying, installing, testing and commissioning dial type Stainless Steel Pressure Gauge (100 mm) with SS casing ,SS bourdon tube suitable for working pressure of 250 PSI, including nipples, etc as required. (Rate Only) |
| 986 | Dry Powder Fire Extinguishing System : |
| 987 | Supplying, installing, testing and commissioning along with necessary supporting arrangement of Ceiling mounted modular type ABC (Dry Chemical Powder) fire extinguisher, capacity 10 Kg / 12 Kg, ISI marked, conforming to IS:15683, with automatic sprinkler type release mechanism, complete with initial charge and accessories as required.(For server and UPS rooms) |
| 988 | Portable Fire Extinguisher : |
| 989 | Supplying, installing, testing and commissioning of ISI marked 6 Kg ABC type (Dry Chemical Powder) fire extinguisher, conforming to IS:15683 (As per latest NBC Norms), complete with wall mounting bracket and initial charge along with floor stand where ever required to be considered as required. Location & ID marking to be considered in bidders scope. In case of floor mounting done near glazing , the stand must be included. Location & ID marking also to be considered in bidders scope. |
| 990 | Supplying, installing, testing and commissioning of ISI marked 2 Kg ABC type (Dry Chemical Powder) fire extinguisher, conforming to IS:15683 (or to be as per latest NBC), complete with wall mounting bracket and initial charge. In case of floor mounting done near glazing , the stand must be included. Location & ID marking also to be considered in bidders scope. |
| 991 | Structural support / Channels forsupportingpiping & etc shall be considered by the bidder |
| 992 | Miscellaneous like Transportation /Scaffolding / Freight, Leading of Material if any / Getting Approvals from Authorities etc as applicable |
| 993 | Notes : |
| 994 | Vendors shall inspect the site and revert in case of any ambiguity before finalisation & the payments will be made for actual measurable quantities only. |
| 995 | It is very important that the vendor shall take approval for all the make / materials etc with COERS / IITM / Architect before procuring and they have to confirm the make to be supplied in the initial stage itself. Bills will not be processed for materials which are not approved by IITM / COERS |
| 996 | Vendor Shall check for Flow switch / Valves etc. as required at site and to provide only if necessary based on client requirement. Hydrant System hose reel is not considered as it is assumed to be available at site. Vendor to check n the same and quote. |
| 997 | Any items required to be quoted apart from BOQ shall be informed to Client / Consultant and approval has to be taken for pricing before bidding and during site visits or during tech clarifications |
| 998 | Upright Sprinklers have not been considered . However in case if required same shall be supplied as per the Rate mentioned above |
| 999 | Any Minor Civil work as required like breaking wall / plastering etc shall be done by bidder. Civil work must be taken care by specialised civil agency under scope of bidder and cost to be included in the above quote. No additional payment will be made at any circumstance |
| 1000 | We have not considered Hydrant system assuming there is already a provision and builder has provided 1 no of Hose reel with Valve. Hence the same need to be checked by bidder and suggest only if required. Any approval as required from govt will be under the scope of bidder for which any modification required in site shall be done by the bidder |
| 1001 | The bidder has to follow the above important notes , In addition they have to follow the tender specifications given by the client. Whichever specs is stringent will have to be followed by the bidder and the same needto be noted. |
| 1002 | NETWORKING BOQ |
| 1003 | SECTION – I : ICT NETWORK |
| 1004 | DATA / TV / PRINTER / RS / ACD / VOICE : CAT6 U/UTP Cables (305 Meter) LAB / WIFI / UPLINK : CAT6A U/UTP Cables (305 Meter) |
| 1005 | Supplying, Laying, termination, testing and commissioning in the existing conduit / Duct, Labelling for the identification of Category 6 U/UTP Cable 23AWG - GREY (LSZH), jacket, 4 pair count, as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1006 | Supplying, termination, testing, commissioning and Fixing & Labelling for the Identificationof Category 6 U/UTP I/O Module - BLUE - DATA / TV / PRINTER (both Panel & User side), as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1007 | Supplying, termination, testing, commissioning and Fixing & Labelling for the Identificationof Category 6 U/UTP I/O Module - GREEN - RS/ACD (both Panel & User side), as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1008 | Supplying, termination, testing, commissioning and Fixing & Labelling for the Identificationof Category 6 U/UTP I/O Module - YELLOW - VOICE (both Panel & User side), as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1009 | Supplying and testing of Category 6 U/UTP28AWG Slim Stranded Patch Cable 0.5M(LSZH) - BLUE - DATA / TV / PRINTER (Panel side) as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1010 | Supplying and testing of Category 6 U/UTP28AWG Slim Stranded Patch Cable 2M(LSZH) - BLUE - DATA / TV / PRINTER (User side) as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1011 | Supplying and testing of Category 6 U/UTP24AWG Stranded Patch Cable 0.5M(LSZH) - GREEN - RS/ACD (Panel side) as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1012 | Supplying and testing of Category 6 U/UTP24AWG Stranded Patch Cable 2M(LSZH) - GREEN - RS/ACD (User side) as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1013 | Supplying and testing of Category 6 U/UTP24AWG Stranded Patch Cable 0.5M(LSZH) - YELLOW - VOICE (Panel side) as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1014 | Supplying and testing of Category 6 U/UTP24AWG Stranded Patch Cable 2M(LSZH) - YELLOW - VOICE (User side) as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1015 | Supplying, Erection, termination, testing and commissioning in inside the Wall mount / Floored Rack, of Category 6 24 Port Un loaded Straight Patch panel supporting with rear cable manager ,as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1016 | Supplying, Laying, termination, testing and commissioning in the existing conduit / Duct, Labelling for the identification of Category 6A U/UTP Cable 23AWG GREY (LSZH), jacket, 4 pair count, as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1017 | Supplying, termination, testing, commissioning and Fixing & Labelling for the Identificationof Category 6A U/UTP I/O Module - GREY - LAB/WIFI/UPLINK (both Panel & User side), as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1018 | Supplying and testing of Category 6A U/UTP24AWG Stranded Patch Cable 0.5M(LSZH) - GREY - LAB/WIFI/UPLINK (Panel side) as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1019 | Supplying and testing of Category 6A U/UTP24AWG Stranded Patch Cable 2M(LSZH) - GREY - LAB/UPLINK (User side) as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1020 | Supplying, termination, testing, commissioning and Fixing & Labelling for the Identificationof Category 6A U/UTP FIELD TERMINATION PLUG - WIFI (User side), as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1021 | Supplying, Erection in the existing concealed box / modular of Single Port Faceplate. The rate shall be include necessary accessories like screw, proper labelling with colour code, etc ., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1022 | Supplying, Erection in the existing concealed box / modular of Dual Port Faceplate. The rate shall be include necessary accessories like screw, proper labelling with colour code, etc ., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1023 | Supplying, Erection in the existing concealed box / modular of Quad Port Faceplate. The rate shall be include necessary accessories like screw, proper labelling with colour code, etc ., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1024 | Supplying, termination, testing, commissioning and Fixing of Indoor / Outdoor Back box complete with all respects Complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1025 | FIBER UPLINK / BACKBONE CONNECTIVITY |
| 1026 | Supplying, Laying, testing and commissioning in the existing conduit / Duct, Labelling the identification of 12F Indoor OM4 6XLC Duplex Pre-Terminated LSZH OFC Cable - 20MTR, as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1027 | Supplying, Erection, termination, testing and commissioning in inside the Wall mount / Floored Rack, termination of 24F Pass-Through Panel with 12XLC OM4 Duplex Adapter with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1028 | Supplying and Tested of LC - LC Duplex OM4 Multimode LSZH Patch cord - 3mtrs, as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1029 | Supplying, Laying, testing and commissioning in the existing conduit / Duct, Labelling the identification of 12 CoreSingle Mode OS2 LSZH OFC Cable - Indoor / Outdoor Unitube Armoured, as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. (HDPE pipe included) |
| 1030 | Supplying, Erection, termination, testing and commissioning in inside the Wall mount / Floored Rack, termination of 24Fiber LIU 1U LC TYPE SM OS2 Fully loaded with pigtails, adapters, splicetray, smouv as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1031 | Supplying and Tested of LC - LC 3mtr Single mode OS2 LSZH Patch Chords, as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. |
| 1032 | RACK ACCESSORIES |
| 1033 | Enclousers ( Network / Switch Rack) Height: 42U H - Width: 800mm Depth:1200mmSupply and fixing of 42U floor mounted Closed Rackwith Standard Accessories like butterfly clamp , vertical managers and all necessary accessories• ROHS Compliance and as per specification and as directed by the Engineer -in-Charge. |
| 1034 | Server /IT Rack mount power distribution unit, 1Ph, 230V, 32A, 50/60Hz, Zero U standard with 12 X Indian Round Pin 5/15A, (Inlet Plug Not Installed, Recommended IEC30932A 2P +E), 16A MCB X 2 Circuits- PDU Rating 7.3KVA/Bottom feed-3Mt/ Black |
| 1035 | LOCAL ITEMS / CONSUMABLES / GENERAL SERVICES |
| 1036 | Copper/Fiber - Fluke Testing with calibrated meter and submit 25yrs performance warranty |
| 1037 | Cable tag, Label sheet, Numbering tag |
| 1038 | Documentation/Project Management |
| 1039 | ACTIVE EQUIPMENTS - SWITCHES - ACCESS / CORE (DATA/VOICE/WIFI/ACD) |
| 1040 | ACTIVE EQUIPMENTS - FIREWALL |
| 1041 | ACTIVE EQUIPMENTS - WIFI AP - WIRELESS |
| 1042 | Total Amount C/o to Summary G in Rs………….. |
| 1043 | ACTIVE EQUIPMENTS - IPPBX - VOICE |
| 1044 | Supply, Erection, Testing and Commissioning of IP-PBX with 64 Extns and expandable up to 24Ports, 2 Trunks, 2 DKP lines. |
| 1045 | Supply, Erection, Testing and Commissioning of IP Phone Business Model - 240*64 Pixels Graphical LCD with Backlit, LED for Incoming/Ongoing Call, Mute and Hold, Intuitive User Interface with Icons, Multiple Languages and Caller ID with Name and Number |
| 1046 | AV BOQ |
| 1047 | Reception |
| 1048 | Professional Display 75” 4K HDR professional display with 24/7 operation,portrait/tilt, Pro-Mode, Airplay and Chromecast |
| 1049 | Wall Bracket Customized wall bracket with adjustable screws |
| 1050 | Installation& Commissioning |
| 1051 | Installation Labour, Project Management, Design and As Built Drawings (Reproducible), Operation and Maintenance Manuals - including Equipment Manuals |
| 1052 | Visitor 4 Pax |
| 1053 | HDMIPatchCord 18 Gig HDMI 2.0 4K @ 60Hz and HDR Certified - 3\" |
| 1054 | HDMIPatchCord 18 Gig HDMI 2.0 4K @ 60Hz and HDR Certified - 15\" |
| 1055 | Installation&Commissioning |
| 1056 | Installation Labour, Project Management, Design and As Built Drawings (Reproducible), Operation and Maintenance Manuals - including Equipment Manuals |
| 1057 | Discussion Room |
| 1058 | ShieldedTwisted PairCable 23 AWG -4 Pair Sheiled CAT 6A (F/UTP) Cable |
| 1059 | RJ45Plug Shielded RJ-45 Plug Kit for Shielded Twisted Pair Cable |
| 1060 | Installation&Commissioning |
| 1061 | Installation Labour, Project Management, Design and As Built Drawings (Reproducible), Operation and Maintenance Manuals - including Equipment Manuals |
| 1062 | Ideation |
| 1063 | USBCCable USB-C® 5 Gbps Cable |
| 1064 | ShieldedTwistedPair Cable 23 AWG -4 Pair Sheiled CAT 6A (F/UTP) Cable |
| 1065 | RJ45Plug Shielded RJ-45 Plug Kit for Shielded Twisted Pair Cable |
| 1066 | Installation&Commissioning |
| 1067 | Installation Labour, Project Management, Design and As Built Drawings (Reproducible), Operation and Maintenance Manuals - including Equipment Manuals |
| 1068 | ConferenceRoom-8Pax |
| 1069 | ShieldedTwisted PairCable 23 AWG -4 Pair Sheiled CAT 6A (F/UTP) Cable |
| 1070 | RJ45Plug Shielded RJ-45 Plug Kit for Shielded Twisted Pair Cable |
| 1071 | Installation&Commissioning |
| 1072 | Installation Labour, Project Management, Design and As Built Drawings (Reproducible), Operation and Maintenance Manuals - including Equipment Manuals |
| 1073 | ConferenceRoom-8Pax |
| 1074 | ShieldedTwisted PairCable 23 AWG -4 Pair Sheiled CAT 6A (F/UTP) Cable |
| 1075 | RJ45Plug Shielded RJ-45 Plug Kit for Shielded Twisted Pair Cable |
| 1076 | Installation&Commissioning |
| 1077 | Installation Labour, Project Management, Design and As Built Drawings (Reproducible), Operation and Maintenance Manuals - including Equipment Manuals |
| 1078 | ConferenceRoom-1&2 |
| 1079 | Professional Display 65” 4K HDR professional display with 24/7 operation,portrait/tilt, Pro-Mode, Airplay and Chromecast |
| 1080 | InteractiveDisplay 98\" 4k IR Touch Technology 20+20= 40 watts speaker & Android 13 8gb ram 64gb rom, OCTO Core processer, EDLA Certified play store Newline Cast, Newline Broadcast & Display Management & Teach Infinity 2 White board with recording software for Windows. Ai Interactive panel withGPT enabled white board software |
| 1081 | MovableTrolley Customized Movable trolly |
| 1082 | AllinOneVideo Bar Premium all-in-one video bar for large conference spaces |
| 1083 | Remote Bluetooth Remote |
| 1084 | Maintancence Services 3 Year Poly+ Studio X72 AVBor equivalent |
| 1085 | TouchController TC10 Touch Controlleror equivalent |
| 1086 | PowerCord Trio C60 Power Supply with Power Cord and CAT-5 INDIA |
| 1087 | Maintancence Services 3 Year Poly+ TC10or equivalent |
| 1088 | IPMicrophone Poly IP Table Microphoneor equivalent |
| 1089 | UCBar Polycom Studioor equivalent: Audio/Video USB Soundbar, withauto track 120-deg FOV 4K Camera, USB stereo speakerphone, BT speakerphone, Wi-Fi device |
| 1090 | ExpandableMic. Poly Studio X50/X52/X70/USB Table Microphone |
| 1091 | Maintenance services 3 Year Poly+ Studio USB video baror equivalent auto track 120 FOV 4K Cam USB stereo BT speakerphones remote |
| 1092 | DecoraPlate Extender 18G Uncompressed HDMI 2.0 / USB-C Auto Switching 4K60 and USB 2.0 High speed extender set with client hub on both ends |
| 1093 | NetworkSwitch 8 Port Network Switch |
| 1094 | ShieldedTwisted PairCable 23 AWG -4 Pair Sheiled CAT 6A (F/UTP) Cable |
| 1095 | USBCCable USB-C® 5 Gbps Cable |
| 1096 | HDMIPatchCord 18 Gig HDMI 2.0 4K @ 60Hz and HDR Certified - 3\" |
| 1097 | HDMIPatchCord 18 Gig HDMI 2.0 4K @ 60Hz and HDR Certified - 6\" |
| 1098 | Installation&Commissioning |
| 1099 | Installation Labour, Project Management, Design and As Built Drawings (Reproducible), Operation and Maintenance Manuals - including Equipment Manuals |
| 1100 | ConferenceRoom-9Pax |
| 1101 | ProfessionalDisplay 65” 4K HDR professional display with 24/7 operation,portrait/tilt, Pro-Mode, Airplay and Chromecast |
| 1102 | WallBracket Customized wall bracket with adjustable screws |
| 1103 | UCBar Polycom Studioor equivalent: Audio/Video USB Soundbar, with auto track 120-deg FOV 4K Camera, USB stereo speakerphone, BT speakerphone, Wi-Fi device management, remote, Cable: 5m USB Type-A to Type-C, Power: India BIS. |
| 1104 | ExpandableMic. Poly Studio X50/X52/X70/USBor equivalent Table Microphone |
| 1105 | Maintenanceservices 3 Year Poly+ Studio USB video bar auto track 120 FOV 4KCam USB stereo BT speakerphones remote |
| 1106 | DecoraPlateExtender 70M 4K HDBaseT Single gang Decora USB-C wall plate extends AV up to 4K and USB2.0 High Speed data |
| 1107 | USBCCable USB-C® 5 Gbps Cable |
| 1108 | HDMIPatchCord 18 Gig HDMI 2.0 4K @ 60Hz and HDR Certified - 3\" |
| 1109 | ShieldedTwistedPair Cable 23 AWG -4 Pair Sheiled CAT 6A (F/UTP) Cable |
| 1110 | RJ45Plug Shielded RJ-45 Plug Kit for Shielded Twisted Pair Cable |
| 1111 | Installation&Commissioning |
| 1112 | Installation Labour, Project Management, Design and As Built Drawings (Reproducible), Operation and Maintenance Manuals - including Equipment Manuals |
| 1113 | Executiveroom |
| 1114 | InteractiveDisplay 65” 4K HDR professional interactive display |
| 1115 | WallBracket Customized wall bracket with adjustable screws |
| 1116 | UCBar All in one Video Bar |
| 1117 | ExpandableMic. Poly Studioor equivalent X50/X52/X70/USB Table Microphone |
| 1118 | WallMountBracket Poly Studio X52/V52or equivalent Wall Mount |
| 1119 | Maintenanceservices 1yr Partner Poly+ Studio X52or equivalent |
| 1120 | Remotecontrol Poly Studio G/X/V Bluetooth Remote Controlor equivalent |
| 1121 | DecoraPlateExtender 70M 4K HDBaseT Single gang Decora USB-C wall plate extends AV up to 4K and USB2.0 High Speed data |
| 1122 | USBCCable USB-C® 5 Gbps Cable |
| 1123 | HDMIPatchCord 18 Gig HDMI 2.0 4K @ 60Hz and HDR Certified - 3\" |
| 1124 | ShieldedTwistedPair Cable 23 AWG -4 Pair Sheiled CAT 6A (F/UTP) Cable |
| 1125 | RJ45Plug Shielded RJ-45 Plug Kit for Shielded Twisted Pair Cable |
| 1126 | Installation&Commissioning |
| 1127 | Installation Labour, Project Management, Design and As Built Drawings (Reproducible), Operation and Maintenance Manuals - including Equipment Manuals |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail