| 1 | Taking down carefully and removing loose and broken concrete by chiseling/ mechanically etc upto a depth of 60 to 150 mm from the roof slab, coloumn, beam and similar structural members cutting edges, cleaning the dismantled portion with wire brush etc to make the reinforcement naked and remove dust, dirt and other foreign particle etc and washing with clean water with pressure and removing rubbish off the premisesto a distance n.exc 50 mtrs and including necessary safety precautions and scaffolding up to a height of 15.0 mtrs complete all as specified. |
| 2 | S&F for Hard drawn steel wire fabric weight not exceeding 4 kg per square metre, cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia welding to existing reinforcement and including necessary safety precautions and scaffolding up to a height of 15.0 mtrs complete all as specified and as directed. |
| 3 | M/L for applying one coat of epoxy bonding coat as per manufacture\"s instruction to bind old concrete surfaces of soffit of slab, column, beam and similar structural members fornew gunited / cement surface. Make : IPH 21 EB of Harjas Coatings & Polymers / Nitobond EP of FOSROC or equivalent make in Dr. Fix it of Pidilite Industries / MC Bauchemie / BASFand including necessary safety precautions and scaffolding up to a height of 15.0 mtrs complete all as specified.and as directed. |
| 4 | M & L for pressure gunniting 40 mm average thickness at a pressure not less than 6kg/ sqcm to all affected RCC structures in cement mortar 1:3 duly modifying with mixture of Nitobond SBR of FOSROC @ 7 litres per 50 kg of cement or IPH-CC resin and IPC-CC hardner of make Harjas Coating & polymers in equal proportion @ 5% of weight of cement or equivalent in Pidilite industries Ltd(Rate included ) andincluding necessary safety precautions and scaffolding, Tools and plantscomplete all as per manufacturer\"s instructions and as directed. |
| 5 | M & L for non shrink, cementatious Micro concrete using Renderoc RG manufactured by M/s. Fosroc Chemicals India [P] Ltd. or its equivalent in Dr. Fixit or IPH-411 of M/s Harjas Coatings & Polymers modified with 12.5mm graded crushed stone aggregate in the ratio by weight (18kg aggregate: 25kg micro concrete) respectively duly modifying with mixture of Nitobond SBR of FOSROC @ 7 litres per 50 kg of cement or IPH-CC resin and IPC-CC hardner of make Harjas Coating & polymers in equal proportion @ 5% of weight of cement or equivalent in Pidilite industries Ltd(Rate included )as per manufacturer\"s instructions, as in sides and soffits of beams,jacketing of columns, ,roof slab and similar structural members including necessary form work for fair finished surfaces use and waste of water tight form work to facilitate pouring of micro concrete, including necessary demolition of RCC any descriptioncomplete all as per manufacturer\"s instructions and including necessary safety precautions and scaffolding up to a height of 15.0 mtrs complete all as specified and as directed. |
| 6 | M&L for applying polymer modified cement mortar rendering 15mm average thick in CM 1:3 on newly gunnited surfaces& Micro concreted surfaces duly mixing polymer modifier \"Nitobond AR\" of make: M/s Fosroc Chemicals India (P) Ltd. @ 10 Ltr per bag of cement or IPH-CC resin and IPC-CC hardner of make Harjas Coating & polymers in equal proportion @ 5% of weight of cement or equivalent in Pidilite industries Ltd(IPH CC resin measured and paid seperately)complete finished even and smooth without using extra cement all as specified and as per manufacturer\"s instructions and including necessary safety precautions and scaffolding up to a height of 15.0 mtrs complete all as specified and as directed. |
| 7 | M & L for applying curing compound of approved make as specified[Concure WB of M/s. Fosroc Chemicals India [P] Ltd. or its equivalent in Dr. Fixit or Harjas Coatings] on newly polymer modified cement mortar as ingunited surfaces & Micro concreted surfaces complete all as per manufacturer\"s instructions and including necessary safety precautions and scaffolding up to a height of 15.0 mtrs complete all as specified and as directed. |
| 8 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and as directed. |
| 9 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and fair without using extra cement complete all as specified and as directed. |
| 10 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed. |
| 11 | Rendering10 mm thick on fair faces of concrete surfaces in ceilings in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed.. |
| 12 | Preparing newly plastered surfaces of wall and applying two coats of oil bound distemperover a layer of 1mm thick putty and a coat ofprimer preparatingto make the surface to be plain and smooth before primer complete all as specified and directed. |
| 13 | Preparing newly plastered surfaces of wall and applying two coats of snowcem complete all as specified and directed. |
| 14 | Preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed. |
| 15 | Taking down Chowkats or frames exceeding 1.5 Sq. M but not exceeding 4 Sq. M each (Without taking off shutters from the frame) complete all as specified and as directed. |
| 16 | Taking down Chowkats or frames Not exceeding 1.5 Sq. M each (Without taking off shutters from the frame) complete all as specified and as directed. |
| 17 | M&L for mild steel framed work section as in door or gates of angle or other section with gusset plates,rails braces etcfor chowkhats and Shutterframe of steel gate of grade Fe-290 (Gde E-165)including necessary sheet andall necessary machine wks i.e. cutting, welding, grinding etc, complete all as specified and directed. |
| 18 | M&L for cement concrete 1:2:4 type B-0 (12.5mm graded aggregate) for bed block for fixing of chowkhats, cills ,pre-cast lintel n.exc 1.5mtr,coping,benching etc complete all as specified. |
| 19 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid cuboard & other Frames/Chowkhat of size 65 x 100(± 5 mm tolerence in dimension) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fastenersincl in this item of required dia and length complete as per direction of Engineer-in-Charge. |
| 20 | S&F Factory made single 35 mm thick extruded WPC (Wood Polymer Composite) solid moulded flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. |
| 21 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plaincolour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 22 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. complete all as specified and directed. |
| 23 | S&F Box type steel Window with 80x40x 1.25mmRHS frame with side hung shutters (double shutters for glass and gauze) with out sash bars jointed togetherwith andincluding grills using 12mm square bars @ 10cm C/C Ref TD No CEBZ/TD/14/ 2011 including boxtype hinges with steel handle and steel peg stay complete with glazing bars dovetailed and welded complete all as specified and as directed by the Engineer-in-Charge |
| 24 | S&F Box type steel Ventilator with 80x40x 1.25mmRHS frame with side hung shutters (double shutters for glass and gauze) with out sash bars jointed togetherwith andincluding grills using 12mm square bars @ 10cm C/C Ref TD No CEBZ/TD/14/ 2011 including boxtype hinges with steel handle and steel peg stay complete with glazing bars dovetailed and welded complete all as specified and as directed by the Engineer-in-Charge |
| 25 | Supply andfabrication of framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars;barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, cooler stand and similar work conforming to Fe.290.Gde-E-165 complete all as spd |
| 26 | S&F of 100mm SS butt hinges ISI marked and fixed with screws or welded to angle frame, complete all as specified and directed. |
| 27 | S&F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 28 | S&F of 200mm long barrel tower bolt aluminum anodized extruded section fixed with cadmium plated screws complete all as specified and directed. |
| 29 | S&F of 150mm aluminum handle cast D type anodized complete all specified and directed. |
| 30 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and directed. |
| 31 | S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed. |
| 32 | S&F 3mm thick sheet glass frosted/figuredandpin headedglazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed. |
| 33 | M&L for ATT ,providing and injecting chemical emulsion for Post Constructionalalong external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as spd |
| 34 | M&L for ATT , providing and injecting of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floorscomplete all as spd |
| 35 | Dismantling Asbestos Cement Corrugated or Semicorrugate in Roof covering, complete all as specified and directed. |
| 36 | Dismantling of Framed timber scantling 40sq cm and over in section in any position complete all as specified and directed. |
| 37 | Dismantling of Framed timber fillet, rails, post, rafters, purlin etcn. exc 40sq cmin section in any position complete all as specified and directed. |
| 38 | S&F of pre-painted 0.50mm thick Gavalume Aluminium Zinc coating GI based corrugated / semi corrugated / trapezoidal steel sheet of any colour having tensile strength 550 MPa and AZ 150 grade as in roof covering/cladding to walls, fixed with self tapping screws, complete all as specified and directed. |
| 39 | S&F pre-painted Galvalume Aluminium Zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength 550 MPa and AZ 150 grade as in ridge of roof covering, fixed with self tapping screws, complete all as specified and directed. |
| 40 | M&L for structural steel Fe-410-W(Gde-E-250) quality B for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket ) framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, complete all as specified and directed. |
| 41 | Preparation of New or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide primer complete all as specified and directed. |
| 42 | Demolition of cement concrete in ground floor including terrazo flooringand paving n exc 15cm thickness (below or above the ground level) built in cement mortar. complete all as specified and directed. |
| 43 | Dismantling for Stone slabs and tiles of any description or thickness in floors, aprons etc, laid dry and pointed in any mortar, complete all as specified and directed. |
| 44 | M&L 75 mm thick cement concrete type D 2 1:4:8 (using 40 mm graded stone agg) in sub base of flooring/ hard standing complete all as specified and directed. |
| 45 | M & L for Providing and laying 60mm thick factory made chamfered edge cement concrete rouber moulded paver block of M-35 grade with grey cement and pigments confirming to IS-15658 (2006) with approved colour design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using rubber mould, laid in required colour & pattern over and including 25mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;complete all as specified and directed |
| 46 | Demolition of brick/stone masonary built in cement mortar incl all quoins arches pillars etc complete all as specified and directed. |
| 47 | M&L for brick work with sub-class B bricksstraight or curved on plan exc 6 Mtr mean radius built in CM (1:6) complete all as specified and directed. |
| 48 | M&L for Stone slab ( Jodhpur stone) 50 mm thick dressed true and square, in 750mm widh of single stone asin plinth protection etc.punched dressed on exposed faces/edges rounded or chamfered and self faced other sideembedded andset jointedin mortar andover 15mm thick screedbedin cementmortar 1:6complete all as spd as directed |
| 49 | Taking down of existing damaged / loosed cement concrete/ brick tiles from roof / terrace to a depth of average 50 mm including taking down of existing APP membrance if any , cleaning with water and depositing of debris to a distance not exceeding 50m complete all as specified & as directed by Engineer-in-Charge |
| 50 | M&L for 15mm renderingincement mortar 1:4 mixed with WPC @3% by weight of cement shall be provided at green concrete complete all as specified & as directed |
| 51 | Supply only Integral waterproofing compound complete all as specified & as directed by Engineer-in-Charge |
| 52 | M&L for Bituminious Primer confirming toIS 3384 @ 0.40Litre per Sqm complete all as specified and directed complete all as spd |
| 53 | M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface of blown bitumenconfirming to IS 702-1988 grade 85/25 @ 1.2kg per sqm by forced application complete all as specified and directed |
| 54 | M&L for PCC 1:2:4 Type B-0 (using 12.5mm graded stone aggregate) average 40mm thick, well compacted with \"V\" shaped groove of 10 mm deep filled with mastic bitumen. Size of PCC panel with groove shall not exceeding 2 Sqm complete all as specified & directed. |
| 55 | M&L for 25mm thickprecast cement concrete type B01:2:4 (using 12.5mm graded aggregate ) as in jally with frame including all mould-ings as per design dircted by Engr in chage, set in CM 1:4 complete all as spd. |
| 56 | Dismantling posts or struts of RCC embedded in concrete base inany section including taking out embedded portion and making good disturbed groung complete |
| 57 | Dismantling of rusted U/Sfencing wire mesh any type complete |
| 58 | Excavation in post holes (or similar holes) each n. exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n. exc 50m and making good surface in hard/densesoil complete all as spd |
| 59 | M&L PCC 1:4:8 type D-2 (40mm graded stone aggregate) in fdn filling and man concrete complete all as spd |
| 60 | M&Lfor angle or tee, Joist, channel, sections, fixedindependently,without connectingplates,etc.(cutto ordinary length confirmto Fe 410 w Grade A as in fencing post includingY neck on boundary wall or fencing post complete all as specified and directed. |
| 61 | M&Lfor mild steelas in Flat for support or stays fixedfor chain link fencing , Holdfast and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 62 | S&F for Mild steel screw bolts (machine made) of length 10 to 15mm long and dia 11 to 15mm with hexagonal or square heads at one end and screwed the other to be fitted with washers and one hexagonal or square nuts complete allas specified & directed. |
| 63 | M&Lfor Chain link fencing incl line wires, any mesh, size and type to any standarards, rails straining bolts etc incl provn of binding wire. complete all as specified and directed. |
| 64 | S&Ffor Galvanised.2strand,steel barbedwire 2.24mm dia barbed with 2mm dia barbs at 75mm spacingsandstraining andfixingtoanytypeof standardrailsstraining bolts, including, securing or tyingatcrossingswithand provision of galvanised mild steelwire complete all as specified and directed. |
| 65 | S & Ffor concertina coil 600 mm dia of each coil and 10 Nos coil / round for 1 RM fixed with top of angle iron Y Section of boundarywall complete allas specified & directed. |
| 66 | M&L for Factory made Pre-cast cement concrete block type B1, 1:2:4 as in kerb stone made to shape as directedby Engr in charge( 300 x150x 450)and setting in mortar 1:4, complete all as specified and as directed. |