| 1 | SCHEDULE \"A\" PART-I : BOQ OF WORKS FOR EXTERNAL ELECTRIC SUPPLY |
| 2 | Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 95.0 Sqmm, 3.50-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed. |
| 3 | Descriptionall as per serial item No- 1.01 here-in-before but for cable ofsize 50 Sqmm 3.5 core |
| 4 | Descriptionall as per serial item No- 1.01 here-in-before but for cable ofsize 35 Sqmm 3.5 core |
| 5 | Descriptionall as per serial item No- 1.01 here-in-before but for cable ofsize 25 Sqmm 4.0 core |
| 6 | Descriptionall as per serial item No- 1.01 here-in-before but for cable ofsize 16 Sqmm 4.0 core |
| 7 | Double wall corrugated HDPE pipe, orange colour, ISI marked, nominal size 50 mm dia with 38 mm inner dia, conforming to IS: 16205 Part-24, including connecting accessories i.e couplers, connectors, bends, sockets, for protection of electric cable, laying in trenches, duct or fixed to walls/ poles as required, complete all as specified and as directed.Make: Prince/ Finolex/ Astral/ RC Plasto/ Supreme. |
| 8 | Replacement old Bus bar chamber with new Bus bar chamber suitable for three phase and neutral supply, with openable door and having locking arrangement, outer size of chamber 400mmx380mmx190mm, made with of Mild Steel sheeting of 3.0mm thick, including Copper bus bars, each of size 320mmx20mmx 6mm thick with fixing arrangement along with insulators, fixing on steel pole with proper mild steel flat clamps, nuts , bolts and washers of required size and making connection of LT cables with thimbles, glands and making good the disturbedsurfaces including painting internally and externally with two coats of aluminium paint over one coat of red oxide primer, having water proof PVC sticker danger mark on bones and scalp,complete all as specified and as directed. |
| 9 | Replacement of old unserviceable sub main wiring with new sub main wiring in PVC conduit of 25mm dia for circuits/ submain wiring along with earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 6.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, using colour coding, drawn in and including any type of conduit/ new casing and caping, any size/ dia including all accessories concealed by chasing/ cutting or fixed with PVC plug and mild steel screws on the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed.Note: Cost of all three run of wire and one run of conduit of 25mm dia will be included in quoted rate. |
| 10 | Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-65, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, fixing in repairs, complete all as specified and as directed. |
| 11 | MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs, fixing in repairs, complete all as specified and as directed. |
| 12 | MCB, single pole and neutral, 40 Amps, 240 volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs, fixing in repairs, complete all as specified and as directed. |
| 13 | MCB, single pole and neutral, 63 Amps, 240 volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs, fixing in repairs, complete all as specified and as directed. |
| 14 | Factory made junction box, made with thermo polycarbonate, weather, water and vermin proof, dust proof, for outdoor use, having internal dimensions 350mmx250mmx100mm, suitable for road/ street lighting for 3-phase/ 4-core high wattage LED based lighting system for industrial applications, suitable for pole mounting,including 01 No. MCB single pole, 6 Amps and 03 Nos. aluminium bus bars of 100 Amps rating duly drilled holes for connections, cable glands, clamps etc for making necessary connections along with locking arrangement, including mild steel iron flat size 25x4mm having holes, nuts, bolts, washers, for fixing/ mounting on poles, painted with two coats of synthetic enamel paint over one coat of primer on internal and external surfaces, fixing in repairs, complete all as specified and directed. |
| 15 | Supply installation, commissioning, new LT feeder pillar box/ panel, in-replacement of old unserviceable LT panel/ feeder pillar box, complete all as specified and as directed by Engineer-In-Charge.Note: Detailed description and accessories/ equipments shall be as mentioned on serial page No- 24 of tender (CA) here-in-after. |
| 16 | LED street light fitting 30 Watt 230 Volt, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, connecting up with three core flexible copper conductor cable of suitable size, and including house service bracket for mounting light fittings. House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.Make: Havells cat part No- Superb Street Light 30 W 6500 K IP65 or equivalent in Phillips/ Bajaj/ Crompton. |
| 17 | Description all as per serial item No- 1.15 here-in-before but for LED street light fitting 50 Watt 230 Volt, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver.Make: Havells cat part No- Superb Street Light 50 W 6500 K IP65 or equivalent in Phillips/ Bajaj/ Crompton. |
| 18 | Description all as per serial item No- 1.15 here-in-before but for LED street light fitting 60 Watt 230 Volt, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver.Make: Havells cat part No- ENDURASUNBEAMGENXSL60WLED757SASYBOPC or equivalent in Phillips/ Bajaj/ Crompton. |
| 19 | Description all as per serial item No- 1.15 here-in-before but for LED street light fitting 70 Watt 230 Volt, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver.Make: Havells cat part No- ENDURASUNBEAMGENXSL70WLED757SASYBOPC or equivalent in Phillips/ Bajaj/ Crompton. |
| 20 | Description all as per serial item No- 1.15 here-in-before but for LED street light fitting 100 Watt 230 Volt, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver.Make: Phillips cat part No- LR02-112-XXX-57-G2 or equivalent in Havells/ Bajaj/ Crompton. |
| 21 | LED Flood light fitting 30 Watt 230 Volt, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, connecting up with three core flexible copper conductor cable of suitable size, and including house service bracket for mounting light fittings. House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.Make: Havells cat part No- JETAADORNFLS30WLED757SSYMTOTGV2 or equivalent in Phillips/ Bajaj/ Crompton. |
| 22 | Description all as per serial item No- 1.20 here-in-before but for LED flood light fitting 50 Watt 230 Volt, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver.Make: Havells cat part No- JETAADORNFLS50WLED757SSYMTOTGV2 or equivalent in Phillips/ Bajaj/ Crompton. |
| 23 | Description all as per serial item No- 1.20 here-in-before but for LED flood light fitting 100 Watt 230 Volt, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver.Make: Havells cat part No- Centura Neo LED Flood Light 100 W 6500 K IP66 or equivalent in Phillips/ Bajaj/ Crompton. |
| 24 | Description all as per serial item No- 1.20 here-in-before but for LED flood light fitting 120 Watt 230 Volt, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver.Make: Havells cat part No-JETAADORNNXTFLS120WLED757SSYMTOTGV2 or equivalent in Phillips/ Bajaj/ Crompton. |
| 25 | LED post top lantan light fitting 35 Watt 230 Volt, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, connecting up with three core flexible copper conductor cable of suitable size, and including house service bracket for mounting light fittings, complete all as specified and directed.Make: Havells cat part No- RUBYNXTPT35WLED757PSYMTOPC or equivalent in Phillips/ Bajaj/ Crompton. |
| 26 | Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor of 6.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0metre apart including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and directed. |
| 27 | Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor of 10.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0metre apart including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and directed. |
| 28 | Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor of 4.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0metre apart including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and directed. |
| 29 | Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron wire, size 4.0mm dia as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 20mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test pointetc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge.Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces. |
| 30 | Excavation in trenches, not exceeding 1.50mtr wide and not exceeding 1.50mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, complete all as specified and as directed. |
| 31 | Excavation in trenches, not exceeding 1.50mtr wide and not exceeding 1.50mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type hard rock, complete all as specified and as directed.Note: Stone retrieved from excavation shall be issued to contractor. |
| 32 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, any type of soil, complete all as specified and as directed. |
| 33 | Removing excavated soil not exceeding 50mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point, complete all as specified and as directed. |
| 34 | Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed.Note: Punned thickness shall be measured. |
| 35 | Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed. |
| 36 | Cutting the road depth up to 1.50mtrs below the ground the level and making trench of suitable width to laying 80mm bore galvanised pipe across the cross-section of the road I horizontally for passing electric cable including making good to road surface as per existing specifications or with plain cement concrete M-20 (1:1.5:3), type B-1 (using 20mm graded crushed stone aggregates), complete all as specified and as directed.Note: Cost of cutting the road, laying electric cable through galvanised iron pipe and material required for making good to road surfaces, shall be deemed included in the quoted rate. |
| 37 | Supply, installation, testing and commissioning in replacement of old unserviceable/ damaged automatic street light switch with new Automatic Street light switch of capacity 5.0 KW in three phase using infrared sensor based nature switch for automatic switching of street lights based on LUX level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminals enclosed in pole / wall mounted enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box (Make: Sintex) conforming to IP54, including mounting arrangementwith suitable size of FI clamps 02 Nos with complete accessories as under including taking down old street light switch, complete all as specified and as directed. (i) Contactor rating (AC3) single phase, 50-63 Amp : [Make : BCH/L&T/Schneider](ii) MCB 63Amps (SP),10 KA, 240 volts: [Make : Schinder/ Legrand/ L&T](iii) NATURESWITCH-01 [Make:HEALER (Model No. SWADEEP - 02EC5KW3P) or equivalent to Schneider/Hensal] |
| 38 | Replacement of old unserviceable/ damaged cable jointing kit with new cable jointing kit for Cable jointing kit for 1.10 KV (Earthed) grade cable for straight through/ termination, heat shrink type joint, complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 10 sqmm to 16 sqmm, 3.5-core/4.0-core, complete all as specified and as directed. |
| 39 | Descriptionall as per serial item No- 1.37 here-in-before but for cable ofsize 25 Sqmm to 50 sqmm |
| 40 | Tubes, \"light grade\" galvanised, 50mm bore, ISI marked including all fitting such as bends, socket, connectors, back nuts, etc, laid in trenches or under floors, complete all as specified and as directed. |
| 41 | Amount of Schedule of credit as mentioned here-in-after shall be deducted from quoted amount. |