Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Material and labour for Annual comprehensive Maintenance for a period of 06 Months and servicing of DG Set of capacity 380 KVAMake Cummins comprising Diesel Engine , AMF Panel & Control panel for the following job by carrying out the following jobs as given below:-(a) Draining out engine oil from the chamber cleaningthe chamber thoroughly and refilling the oil panwith new engine oil to it’s required level, (b) Draining out of diesel from tank, cleaningthe tank thoroughlyand refilling the drained out diesel(c) Supply and replacment of fuel filter set(d) Supply and replcement of lubricating oil filter set(e) Supply and replacement By pass filter set(f)Checking & cleaning air cleaner(g) Check and topping up coolant level(h) Checking the starting batteries and filling with electrolyte/Distilled water to maintain the required specific gravity. Cleaning of Battery terminals & applying petroleum jelly to battery terminal posts & brass connectors(j) Checking and clearning exhaust system including removing of deposited carbon in exhuast pipe.(k) Adjustment /setting of V Belt and fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories asprescribed by the manufacturer(l) Checking, cleaning and servicing of self starter, Alternator, sensors etc.(m) Testing of DG set at connected load all as directed by the Engr in charge. (n) Replacement of burnout Copper/aluminium thimbles existing size by crimping with crimping tool properly completely. |
| 2 | Note (a) Petroleum jelly, waste cloth, seal, gaskets etc are to be provided by the contractor and the cost is deemed to be included in quoted rate. (b) Coolent for topping up and Engine oil, Fuel filter, oil filter, bypass filter, water filter wii be measured and paid saparetly under relevant items.(c) Engine oil /Spares/filters of make reccomended by OEM will only be used for servicing of DG set. Material and Labour for ‘B’ check servicing of all as per manufacturer instructions, includingcost of following ‘B’ check spares and minor spares required for carrying out the check like nut, bolts, washers,gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolant in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolant from engine and near by spare parts of engine of make Cummins and Alternator make-Stamford and capacity 380 KVA, installed at CZW, complete including testing after repair for its smooth functioning :-(a)Lubricating oil filter - 01 No(b)Filter for Coolant- 01 No(c)Fuel filter- 02 Nos(d)Water Filter - 01 No(e)Minor spares and waste cotton for cleaning - 01 KitNote :1.Quoted rate deemed to be included fuel filter kits and lubricating oil filter kits and minor spares required for check. 2.Engine oil, Coolant for radiator, distilled water and new air filter element shall be measured and paid separately under relevant items of this schedule. |
| 3 | All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar and capacity, 200 KVA, installed atABOD Adm - 01 Set. (a)Lubricating oil filter - 02 Nos(b)Fuel filter - 02 Nos(c)Minor spares and waste cotton for cleaning - 01 Kit |
| 4 | All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar and capacity, 160 KVA installed atFAD Adm Area/Security lights-01 Set and at ABOD NBC Shed-01 Set.(a)Lubricating oil filter - 02 Nos(b)Fuel filter - 02 Nos(c)Minor spares and waste cotton for cleaning - 01 Kit |
| 5 | All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar and capacity, 125 KVA installed at Filteration plant near \"D\" Block-01 Set.(a)Lubricating oil filter - 02 Nos(b)Fuel filter - 02 Nos(c)Minor spares and waste cotton for cleaning - 01 Kit |
| 6 | All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar Bliss and capacity, 125 KVA installed at CPWD PH-01 Set. (a)Lubricating oil filter- 01 No(b)Fuel filter - 01 No(c)Minor spares and waste cotton for cleaning - 01 Kit |
| 7 | All as per item No 01 here-in- above but make of alternator and Engine is Crompton Greves and capacity, 125 KVA installed at AC PlantFAD Depot Area. (a)Lubricating oil filter- 01 No(b)Fuel filter- 02 Nos(c)Minor spares and waste cotton for cleaning - 01 Kit |
| 8 | All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar Green and capacity 100 KVA, installed atFAD-01Set and 41 Veh-01 Set. . (a)lubricating oil filter- 02 Nos(b)Fuel filter kit Secondary Element - 01 No(c)Fuel filter kit primary Element- 01 No.(d)Minor spares and waste cotton for cleaning - 01 Kit |
| 9 | All as per item No 01 here-in- above but make of Engine & Alternator is Kirloskar Bliss and and capacity 100 KVA, installed at Signal Centre Server room - 01 Set. (a)Lubricating oil filter- 01 No(b)Fuel filter- 01 No(c)Minor spares and waste cotton for cleaning - 01 Kit |
| 10 | All as per item No 01 here-in- above but make of Engine is Kirloskar and Alternator make-Jyoti and capacity, 75 KVA installed at 51 Sub Area-01 Set. (a)Lubricating oil filter- 01 No(b)Fuel filter- 02 Nos(c)Minor spares and waste cotton for cleaning - 01 Kit |
| 11 | All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar and capacity, 62.5 KVA installed at 222 ABOD- 01 Set. (a)Filter for lubricating oil - 01 No(b)Fuel filter kit- 01 No |
| 12 | All as per item No 01 here-in- above but make of alternator and Engine (4R1040) is Kirloskar and capacity 50 KVA, installed at Office Area - 01 set. (a)Lubricating oil filter - 01 No(b)Fuel filter kit- 01 No |
| 13 | All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar and capacity, 40 KVA installed at MAP CPWD Pump House-01 set. (a)Filter for lubricating oil - 01 No(b)Fuel filter kit- 01 No |
| 14 | All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar and capacity, 20 KVA installed at NOI- 01 set. (a)Filter for lubricating oil - 01 No(b)Fuel filter kit- 01 No |
| 15 | All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar and capacity, 15 KVA installed at ADG NEI- 01 set. (a)Filter for lubricating oil - 01 No(b)Fuel filter kit- 01 No |
| 16 | All as per item No 01 here-in- above but Diesel Fire Pump of105HP/76BHP any make : Kirloskar and capacity, installed at 222 ABOD/14 FADFire Pump House-01 set. (a)Filter for lubricating oil - 01 No(b)Fuel filter kit- 01 No (Note : Job Include servicing of Pump complete testing and commissioning all as specified and directed. |
| 17 | Supply only engine oil grade 20W40 against \"B\" check servicing and as per the capacity of engine model and as per manufacturers recommendation complete all as directed. |
| 18 | Supply only coolantagainst \"B\" check servicing for radiator of water cooled engines of any make/capacity and as per manufacturers recommendation complete all as directed. |
| 19 | Supply and top up / replace distilled water for battery or radiator of engine usedcomplete all as directed. |
| 20 | Material and labour for replacement of unserviceable tachometer with electronic type tachometer of any capacity complete all as directed. |
| 21 | Removing existing unserviceble battery and supply and fix lead acid battery maintenance free 12 volts 180AH of make : EXIDE Xpress/SF/LUMINIOUS fully charged complete all as directed. |
| 22 | Removing existing unserviceble battery and supplied and fixed lead acid battery maintenance free 12 volts 130 AH as per cat part No FXPO-MHD1300 of make EXIDE Xpress fully charged complete all as directed. |
| 23 | Dismantling unserviceable battery charging dynamo from DG set of rating 1 x 12 / 2 x 12 Volts complete repairs and servicing including replacement of bushes, bearings, Carbon brushes, rectifiers, rewinding of field magnet coil / rotor armeture coils and any other minor parts required all as directed and fixing on engine including testing/commissioning complete for DG set having any capacity complete all as directed.Note :Replacement of rotor armature coil if required shall be measured and paid seperately. |
| 24 | Replacement of rotor armature coil suitable for battery charging dynamo of DG set complete all as directed. |
| 25 | Dismantling self starter of DG set for repairing the starter by replacing carbon brushes, brush holder, bearings, solenoid coil, replacement of burnt armature, rewinding of Fd coils, replacement of pinion gears etc, complete servicing and refixing after repair including testing/commissioning complete for DG Set any capacity complete all as directed.(Note : Quoted rate is exclusive of solenoid coil, armeture coil, and pinion gear. If this items are required, they will be measured and paid separately as supply only under relevant items. |
| 26 | Supply only solenoid coil suitable for DG set self starter |
| 27 | Supply only armeture coil complete with shaft suitable for DG set self starter |
| 28 | Supply only pinion gear suitable for DG set self starter |
| 29 | Dismantling old unserviceable battery charging dynamo of rating 12 volts and supply and fixing new battery charging dynamo same as per existing model suitable for fixing on DG set, 1500 rpmincluding testing after installation complete all as directed. |
| 30 | Dismantling old unserviceable battery charging dynamo of rating 24 volts and supply and fixing new battery charging dynamo same as per existing model suitable for fixing on DG set, 1500 rpm including testing afterinstallation complete all as directed. |
| 31 | Dismantling old unserviceable Self starter of Diesel engine and supply and fixing new self starter of working voltage 12 volt/24 Volt DC and same as per existing model suitable for fixing on engine set including testing afterinstallation complete all as directed. |
| 32 | Material and labour for Removing existing defective wiring of DG set AMF panel, rewiring with multistranded single core PVC insulated copper conductor wire, 2.5 sqmm for AC/DC supply connections to all control system and devices and testing of AMFpanel afterrepair complete all as directed.Note : Unserviceable spare like power contactor, auxilary contactor, Digital meters, relays, indication lamps, rotary selector switches etc shall be measured and paid separately as supply only under relevant items.Note :PVC insulated copper conductor wire, 2.5 sqmm for AC/DC supply connections is deemed to be included in quoted rate. |
| 33 | Supply only power contactor 4 pole, 415 volt, AC1 rating160 Amps suitable for AMF panel board complete all as per existing make & model complete all as specified and directed. |
| 34 | Supply only power contactor 4 pole, 415 volt, AC1 rating 100Amps suitable for AMF panel board complete all as per existing make & model complete all as specified and directed. |
| 35 | Supply only power contactor 4 pole, 415 volt, AC1 rating 16 Amp to 40 Amps suitable for AMF panel board complete all as per existing make & model complete all as specified and directed. |
| 36 | Supply only EC2 AMF logic relays, suitable for DG set AMF panel board. |
| 37 | Supply only overload relay suitable for AMF/LT panel board all as per existing make & model complete all as specified and directed. |
| 38 | Supply only SMPS automatic battery charger 12 volt suitable for DG set AMF panel board. |
| 39 | Supply only SMPS automatic battery charger 24 volt suitable for DG set AMF panel board. |
| 40 | Supply only multifunctionmeter flush mounting accuracy class 1.0in AMF panel . |
| 41 | Supply only Air filter element suitable for DG set Engine of make Cummins and capacity380 KVA installed atABW. |
| 42 | Supply only Air filter elementsuitable for DG set Engine of make Kirloskar and capacity200 KVA installed atABOD. |
| 43 | Supply only Air filter elementsuitable for DG set Engine of make Kirloskar and capacity160 KVA installed atABOD NBC Shed and at FAD Adm DG Set. |
| 44 | Supply only Air filter elementsuitable for DG set Engine of make Kirloskar and capacity125 KVA installed at Filteration plant-01 Set |
| 45 | Supply only Air filter elementinner and outer suitable for DG set Engine of make Crompton Greaves and capacity 125 KVA installed at AC Plant FAD Depot 01 Set. |
| 46 | Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity 100 KVA installed at Singal Centre-01 Set |
| 47 | Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity 100 KVA installed at FAD depo-01 Set & Veh-01 Set |
| 48 | Supply only Air filter elementsuitable for DG set Engine of make Kirloskar and capacity 75 KVA installed at Sub Area-01 Set and New Filter plant-01 Set. |
| 49 | Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity62.5 KVA installed at Sewage Treatment plant |
| 50 | Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity62.5 KVA installed at ABOD Depot Area. |
| 51 | Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity50 KVA installed atOffice. |
| 52 | Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity 40 KVA installed at CPWD Pump House. |
| 53 | Supply and fix in repair \"V\" belt ribbed of radiator fan belt suitable for DG Set 62.5 KVA to380 KVA complete all as specified and directed. |
| 54 | Supply and fix in repair \"V\" belt ribbed ofbattery charging dynomo belt,suitable for DG set 62.5 KVA to 380 KVA complete all as specified and directed. |
| 55 | Supply and fix in repair \"V\" belt ribbed ofwater pump belt all suitable for DG set 62.5 KVA to 380KVAcomplete all as specified and directed. |
| 56 | Supply and fix in repair \"V\" belt ribbed ofradiator fan belt/ battery charging dynomo belt/water pump belt suitable for DG set15 KVA to 20 KVA any type complete all as specified and directed. |
| 57 | Material and labour for draining out coolant water from radiator, dismantling radiator, repair of radiator for leakage if any, cleaning the radiator set with dilute Hydro Chloric Acid, kerosene, fresh water and refixing the same with new rubber hose with clamps filling with coolant with distilled water and checking for its proper function on DG set all as directed and specified.Note : Coolant and distilled water shall be measured and paid separately under relavant items. |
| 58 | Material and labour for dismantling the unserviceable FIP from DG set engine and taking it to auth workshop for cleaning, overhauling/servicing and calibration with prescribed overhauling kit of any capacity DG set with replacement of unserviceable parts/spares as required for repair of injectors, re-fixing the FIP and checking the same for its smooth functioning on DG set complete all as directed by Engineer in charge. Note : Necessary spares required for repairing and servicing of FIP incude in quoted rates & Transportation to workshop complete. |
| 59 | Labour only for attending breakdowns of DG sets/AMF panels through skilled technician from reputed service centre of DG sets with necessary tool kits, checking Engine and alternator for defects, carryout necessary repairs works to rectify the defects without major overhauling/opening of Engine or Alternators, replace of external spare to repair/rectify the defects and testing DG set for its smooth functioning on full load complete all asdirected. Note :1.Necessary spares required to rectify the defects shall be measured and paid separately as supply only under relavant items.2.The complaint shall be attended and rectifed within 24 hours from time of reporting by Engr-in-Charge or his authorised representative.3. Any Major defects shall be reported on priority to Engr-in-Charge to avoid undue delay in fuctioning of installation. |
| 60 | Supply only rubber hose pipe set (Hose oil/Hose radiator/CR Hose/Makeup Hose) suitable for DG sets of capacity ranging from 40 KVA to 75 KVA all as per existing sample with GI clamps and Nut bolt, washers for DG set complete all as directed. |
| 61 | Supply only rubber hose pipe set (Hose oil/Hose radiator/CR Hose/Makeup Hose) suitable for DG sets of capacity ranging from 100 KVA to 200 KVA all as per existing sample with GI clamps and Nut bolt, washers for DG set complete all as directed. |
| 62 | Supply only rubber hose pipe set (Hose oil/Hose radiator/CR Hose/Makeup Hose) suitable for DG sets of capacity 380 KVA and above all as per existing sample with GI clamps and Nut bolt, washers for DG set complete all as directed. |
| 63 | Supply and fix MCCB with Thermal - magnetic release of 80-100 Amps, 3 Pole, 415V, 25 kA, Ics=100%Icuwith adjustable over load settingand adjustable short circuit setting including all accessories and taking down old unserviceable one.Note:- Any modifications for fixing the MCCB\"s in the existing AMF Panel orLT Panel reqd, the cost for this modificationsalong with cable lugs or thimbles & spreader. |
| 64 | Supply and fix MCCB with Thermal - magnetic release of 250 Amps, 4 Pole, 415V, 36 kA, Ics=100%Icuwith adjustable over load settingand adjustable short circuit setting including all accessories and taking down old unserviceable one. |
| 65 | Supply and fix MCCB with Thermal - magnetic release of 125-160 Amps, 4 Pole, 415V, 25 kA, Ics=100%Icuwith adjustable over load settingand adjustable short circuit setting including all accessories and taking down old unserviceable one. |
| 66 | Supply and fix in repair ON LOAD change over switch, 4 pole, 415 Volts, 200 Amps capacityopen execution typecomplete all as directed. |
| 67 | Taking out from DG set,transportation to repairs to injector including cleaning of nozzels complete all as directed. Note : One No Injector incl nozzels to be measured as one job & rates for transportation to workshop and back is included in the quoted rates. |
| 68 | Repairs to turbo charger complete all as directed. |
| 69 | Cleaning of DG set fuel tank of capacity upto 100 KVA by draining out residual oil and removal of sludge from bottom of the tank complete all as directed. |
| 70 | All as per Item No. 69 but capacity exceeding100 KVA but not exceeding 200 KVA |
| 71 | All as per Item No. 69 but capacity exceeding 200 KVA but not exceeding 380 KVA |
| 72 | Repairs to automatic voltage regulator (AVR) including replacement of electronic printed circuit board (PCB) and wire connections of alternator of any capacity complete all as specified and directed. |
| 73 | Supply and fix repair/ replacment of battery charger fixed on panel board of 12V/24V DC from 230V ACas existing complete all asincluding replacement of electronic printed circuit board (PCB) and wire connectionscomplete all as specified and directed. |
| 74 | Supply and fix in repairs solenoid switch with fuel shut off valve compatible to auto mainsfailure panel for remote operation complete all as specified and directed. |
| 75 | Supply and fix in repairs battery terminal leads of 2AWG (35sqmm) copper wire single core PVC insulated 1.5m long of colour coding red or black complete withbrass terminals fixed at site with petroleum jelly complete all as specified and directed. |
| 76 | Supply and fix centrifugal gear driven,Cast iron body water pump assembly suiatable for 62.5 KVA to 200 KVAKirloskar Diesel Engine Cooling system complete all as specified and directed. |
| 77 | Supply and fix Cast iron body pressure fuel pump assembly suiatable for 62.5 KVAto 200 KVA of existing make and model complete all as specified and directed. |
| 78 | Supply and fix in repairMCB TP 25 to 63 A, 415V,50Hz, C series breaking capacity 10kA all as specified and directed. |
| 79 | Material and labour for servicing of Newely installed Diesel Engine Generator set of 100 KVAby taking down oil sump after draining unserviceable enigne oil from drain plug and storing in a container, cleaning the sump and refilling Engine oil, running testing and refilling as top up for proper level, greasing the movable parts and cleaning complete body after repairing all oil / fuel leakages complete all as specified and directed.Note:- Servicing to be carried out by service engineer of OEM/auth rep of OEM &Engine oil shall be measured and paid separately under relevant item of this schedule. |
| 80 | Material and labour for servicing of Newely installed Diesel Engine Generator set of 15 KVAby taking down oil sump after draining unserviceable enigne oil from drain plug and storing in a container, cleaning the sump and refilling Engine oil, running testing and refilling as top up for proper level, greasing the movable parts and cleaning complete body after repairing all oil / fuel leakages complete all as specified and directed.Note:- Servicing to be carried out by service engineer of OEM/auth rep of OEM &Engine oil shall be measured and paid separately under relevant item of this schedule |
| 81 | Material and labour for servicing of Newely installed Diesel Engine Generator set of 250 KVA make Greaves CPCB IV+ by taking down oil sump after draining unserviceable enigne oil from drain plug and storing in a container, cleaning the sump and refilling Engine oil, running testing and refilling as top up for proper level, greasing the movable parts and cleaning complete body after repairing all oil / fuel leakages, include all type of filters and topping up urea tank complete all as specified and directed.Note:- Servicing to be carried out by service engineer of OEM/auth rep of OEM &Engine oil, filters any type shall be measured and paid separately under relevant item of this schedule |
| 82 | Supply and fixingin repairs battery charger for 12 V battery in sheet metal enclosure having voltmeter and ammeter of capacity 10 Amps with two Nos lead with terminal clamps complete all as specified and directed. of AMF panel of make as per existing complete all as specified and directed. |
| 83 | Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 70 Sq mm 3.5 core including taking down complete all as specified and directed |
| 84 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m deep, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed |
| 85 | Removal of excavated material / soils to a distance n exc 50m and depositing where directed at a level not exceeding 1.5m above the straight point complete all as specified and directed. |
| 86 | Returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm in soft / loose soil complete all as specified and directed. |
| 87 | Material and labour sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. |
| 88 | Supply and fix bricks using sub class‘B’ bricks (old size) for cable protection laid flat and dry in trenches over cable perpendicular to direction of cable, complete all as specified and directed. |
| 89 | Material and labour for repairing, welding doors to main body include AMF Panel board, hinges fitting, replacement of lock, handleand making good for the canopy of DG set /panel baord off capacity including painting with exixting colour after surface preparation complete all as specified and directed by Engineer in charge |
| 90 | Dismentaling of defective Alternator from DG set of capacity 62.5 KVA to 200 KVA from DG set by opening coupling shaft and taking out carefully rotor and windingsby disconnecting the internal connections.Removing cabon bushes , replacement of unserviceable bushes , nuts & bolts, cutting the burnt winding and re-winding the same with suitable size of super enameled copper wire as pr existing gauge, insulating the winding connection by using fire proof sleeve and fire fire proof tape, varnishing the coil, keeping the coils in Sun light/ oven for removing moisture , painting of Alternator body outside , marking MES/SM No etc , refixing the alternator with engine with proper alignment of coupling and shaft, and connecting electric connections internal and outside properly, making the all connections with suitable coppr lugs , meggering the Alternator, testing the load of alternator complete all as specified and directed.Note : (i) Winding wire for making coils will be measured and paid seperately.(ii) Contractor is required to submit test report for repaired alternator duly signed by Engr-in-Charge.(iii) Rates for transportation of Alternator from site to Workshop and return back from workshop to be included in quoted rates.(iv) Necessary load test be crried out in presence of Engr in charge and T&P required for the job isincluded in the quoted rates. |
| 91 | Supply only super enameled copper conductor wire suitable gauge and size as per requirement for rewinding of Alternator of capacity 62.5 KVA to 200 KVA complete all as specified and directed. |
| 92 | Supply and fixing as in repair metal fuel injector pipe of make Lucas TVS / Mico suitable for DG Set of make Kirloskar / Mahindra / Ashok Leylandof capacity 62.5 KVA to 380 KVAcomplete all as specified and directed |
| 93 | Supply and fixing as in repair metal flexible fuel pipe having both end benjo nuts or as per samplecomplete all as specified and directed |
| 94 | Supply and topping up of coolent for DG set in sealed container Make as recommended by OEM of DG Set complete all as specified and directed . |
| 95 | Repair to alternator of DG set 20 KVA to 100 KVA, servicing, greasing of alternator, cleaning the dust including replacement of defective rectifier of suitable capacity, testing complete of alternator for out put voltage and load etc complete all as specified and directed . |
| 96 | Repair to alternator of DG set 125 KVA to 380 KVA, servicing, alternator, cleaning the dust including replacement of defective rectifier of suitable capacity, testing complete of alternator for out put voltage and load etc complete all as specified and directed . |
| 97 | Material and labour for dismantling of radiator assembly from the DG set suitable for 62.5 to 125 KVA including transporting to the civilworkshop for necessary repair, checking leakage, brazing, cleaning with suitable cleaning agent and filling coolent and fixing back to the DG set complete including testing and commissioning complete all as specified and directed.Note:- (i) Transportation of radiator to the workshop and back shall be provided by the contractor and the cost thereof shall be deemed included in unit quoted rate. |
| 98 | Material and labour for dismantling of radiator assembly both primary & secondry from the DG set suitable for 200 KVAincluding transporting to the civilworkshop for necessary repair, checking leakage, brazing, cleaning with suitable cleaning agent and filling coolent and fixing back to the DG set complete including testing and commissioning complete all as specified and directed.Note:- (i) Transportation of radiator to the workshop and back shall be provided by the contractor and the cost thereof shall be deemed included in unit quoted rate. |
| 99 | Material and labour for dismantling of radiator assembly both primary & secondary from the DG set suitable for 380 KVA including transporting to the civilworkshop for necessary repair, checking leakage, brazing, cleaning with suitable cleaning agent and filling coolent and fixing back to the DG set complete including testing and commissioning complete all as specified and directed.Note:- (i) Transportation of radiator to the workshop and back shall be provided by the contractor and the cost thereof shall be deemed included in unit quoted rate. |
| 100 | Material and labour for servicing of self starter 12/24V of DG Set any make and capacity include cleaning and replacement of bushes complete all as specified and directed. |
| 101 | Supply and fix Fuel filter assembly of make LUCAS/TVS suitable for DG Set of any make of rating 62.5 KVA to 125 KVA complete all as specified and directed. |
| 102 | Supply and fix Fuel filter assembly of make LUCAS/TVS suitable for DG Set of any make of rating 200 KVA to 380 KVA complete all as specified and directed. |
| 103 | Supply and fix Radiator Cap of DG Set include chain complete all as specified and directed. |
| 104 | Supply and fix Micor processor based controller fixed in DG of capacity 62.5 to 125 KVA of make as existing include testing and commissioning complete all as specified and directed. |
| 105 | Taking down old and Supply and fix Micro processor based controller fixed in DG of capacity 200 KVA of make & Model as existing include testing and commissioning complete all as specified and directed. |
| 106 | Taking down old and Supply and fix Micro processor based ECPG controller fixed in DG of capacity 380 KVA of make & Model as existing include testing and commissioning complete all as specified and directed. |
| 107 | Supply and fix Micor processor based Relay card fixed in DG of capacity 62.5 to 125 KVA of make as existing include testing and commissioning complete all as specified and directed. |
| 108 | Supply and fix Brass Battery terminal Heavy duty having nuts & bolts complete all as specified and directed . |
| 109 | Material and labour for complete Overhauling of engine of DG Set 160KVAmake : KirloskarModel : including dismantling of Head assy, Pistons, Cylinder linner, crankshaft, Radiator complete and kept aside in safe custody, Head assy,crankshaft, cylinder linear send for workshop for necessary repair work, reassembling the same after replacement of under mentioned parts as per requirement, tuning cleaning of distributors, greasing / oiling assembling / testing all as per requirement of engine complete all as specified and directed:-Note:- (i) Unit rate of this item includes the dismantling of engineand transportation of same to workshop and back.(ii)After completion of work necessary laod test be carried out and T&P required for laod testing be included in quoted rates.(iii) Any other items required after opening engine , the contractor should inform GE before start work.(iv) Initally DG set run at no load for min 2 Hrs after that gradually load will increased. (iv) Any other minor items of amount RS 1000/- or T&P or cleaning materials required at site be included in the quoted rates. |
| 110 | Supply only Cylinder Linear (6 Nos) |
| 111 | Supply only Piston Assy |
| 112 | Supply only Piston Ring |
| 113 | Supply only C R Bearing |
| 114 | Supply only Head Gasket |
| 115 | Supply only Gasket Kit |
| 116 | Supply only Engine Valve |
| 117 | Supply only Valve Valve Guide |
| 118 | Supply onlyValve Seat |
| 119 | Supply only Valve oil Seal |
| 120 | Supply only Lube oil filter |
| 121 | Supply onlyFuel Filter |
| 122 | Supply only Lube oil 15W40 |
| 123 | Supply only Copper washer |
| 124 | Supply onlyHose Pipe |
| 125 | Supply only U Ring Kit |
| 126 | Supply onlyAir Filter |
| 127 | Material and labour for complete Overhauling of engine of DG Set 200KVAmake : KirloskarModel :including dismantling of Head assy, Pistons, Cylinder linner, crankshaft, Radiator complete and kept aside in safe custody, Head assy,crankshaft, cylinder linear send for workshop for necessary repair work, reassembling the same after replacement of under mentioned parts as per requirement, tuning cleaning of distributors, greasing / oiling assembling / testing all as per requirement of engine complete all as specified and directed:-Note:- (i) Unit rate of this item includes the dismantling of engineand transportation of same to workshop and back.(ii)After completion of work necessary laod test be carried out and T&P required for laod testing be included in quoted rates.(iii) Any other items required after opening engine , the contractor should inform GE before start work.(iv) Initally DG set run at no load for min 2 Hrs after that gradually load will increased. (iv) Any other minor items of amount RS 1000/- or T&P or cleaning materials required at site be included in the quoted rates. |
| 128 | Supply onlyCylinder Linear (6 Nos) |
| 129 | Supply only Piston Assy |
| 130 | Supply onlyPiston Ring |
| 131 | Supply onlyC R Bearing |
| 132 | Supply only Head Gasket |
| 133 | Supply only Gasket Kit |
| 134 | Supply only Engine Valve |
| 135 | Supply only Valve Guide |
| 136 | Supply only Valve Seat |
| 137 | Supply only Valve oil Seal |
| 138 | Supply only Lube oil filter |
| 139 | Supply only Fuel Filter |
| 140 | Supply only Lube oil 15W40 |
| 141 | Supply only Copper washer |
| 142 | Supply only Coolant |
| 143 | Supply only Linear O Ring |
| 144 | Supply only Air Filter |
| 145 | Material and labour for filling Diseal Exhaust fluid (Urea) required for DG Sets having CPCB IV+ catagory. |
| 146 | Material and lanour for Strip opening of 12.5 HP to 15HP 3 phase AC Non clog submersible pumpset any type taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tapeall as specified and directed and re-assembling the motor and testing compelete of the following rating:-Note : Rates include all required T&P shall be supplied by the contractor include transportation of motor from site to workshop and back to site after necessary repair works. |
| 147 | Replacement of tungstun mechanical shaft seal for sewage pump applicationas per OEM . |
| 148 | Replacement of oil seal in non clog submersible sewage motor pump set of any rating as per OEM . |
| 149 | Replacement of DE roller bearingas per OEM . |
| 150 | Replacement of NDE ball bearingas per OEM . |
| 151 | Replacement of set of O rings . |
| 152 | Reparing of impeller shaft in non clog submersible sewage pump set of any capacity by metal filling, machining, turningand lathe work in wksp complete include testing and ciommissioning. |
| 153 | Supply and filling insulation oil as per OEM . |
| 154 | Material and lanour for Strip opening of 25 HP 3 phase AC Non clog submersible pumpset any type taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tapeall as specified and directed and re-assembling the motor and testing compelete of the following rating:-Note : Rates include all required T&P shall be supplied by the contractor include transportation of motor from site to workshop and back to site after necessary repair works. |
| 155 | Replacement of oil seal in non clog submersible sewage motor pump set of any rating as per OEM . |
| 156 | Replacement of DE roller bearingas per OEM . |
| 157 | Replacement of NDE ball bearingas per OEM . |
| 158 | Replacement of set of O rings. |
| 159 | Reparing of impeller shaft in non clog submersible sewage pump set of any capacity by metal filling, machining, turningand lathe work in wksp complete include testing and ciommissioning. |
| 160 | Supply and fix CI/GI bend of suitable size including suitable for non clog pump complete including nuts & bolts, rubber gasket complete. |
| 161 | Supply and fix MS chain closed type of size 12mm including round ring insert on every mtr include chain lock, Nuts & Bolts fixed on non clog sewage submersible pump complete all as specified and directed . |
| 162 | Repairing of existing starter/panel by disconnecting existing burn out cable/ wiring and replaced with 1.5 Sqmm single core copper conductor or suitable size as per existing cable include replacement ofDigital Volt meter, Digital Amp Meter alongwith CTs, relays, making connection, replacement of cable lugs of suitable size, repair/replacement of locking arrangement include painting with two coat of synthetic enamel paint complete all as specified and directed. Note : Repalcement of contractor, relay, MCCBs, Volt Meter & Amp Meter will be measured & paid seperately. |
| 163 | Supply and fix in replacement of Voltmeters having LED display, accuracy class 1.0,0.5, Input voltage measurement rane 50-520VAC, Au supply 80-300 VAC/DC, flush mounting type 96x96mm complete including fixing in panel board complete all as specified and directed. |
| 164 | Supply and fix in replacement of Amp meters having 3 line LED display, accuracy class 1.0,0.5, Input voltage measurement rane 50-520VAC, Au supply 80-300 VAC/DC, ST secondary site selectable 1A/5A, flush mounting type 96x96mm complete including fixing in panel board complete all as specified and directed. |
| 165 | Supply and fix Copper Spreaders link Terminals(set of 8) of voltage upto 690V AC, suitbale for 250 Amps MCCBs complete all as specified and directed. |
| 166 | Supply and fix in replacement of Multifunction meters having 3 line LED display, accuracy class 1.0,0.5, Input voltage measurement rane 50-520VAC, Au supply 80-300 VAC/DC, ST secondary site selectable 1A/5A, flush mounting type 96x96mm complete including fixing in panel board complete all as specified and directed. |
| 167 | Supply and fixing in repair Star Delta Starter in sheet metal enclosure suitable for 15 HP motor, 3 Phase, 415 Volt. complete all as specified and directed. |
| 168 | Supply and fixing in repair DOL Starter suitable for 1 to 5 HP 440 Volt. complete all as specified and directed. |
| 169 | Supply only Contactor ML/MNX or equivalent of 16/25Amps, 415 volts complete all as specified and directed. |
| 170 | Supply only Contactor ML/MNX or equivalent of 32/40Amps, 415 volts complete all as specified and directed. |
| 171 | Supply only delay timer relay suitable for starter up to 25HP complete all as specified and directed. |
| 172 | Supply only single phase preventer to protect motor for phase failure complete all as specified and direced. |
| 173 | Supply and fix Indicator lamp LED type of RYB colour , 230 Volts.complete all as specified and directed. |
| 174 | Material and lanour for MCCB TP NL LT 415 volt 50 Hz, AC 125 amps 25 KA with thermal magnetic release for OL & SC protectioncomplete all as specified and directed. |
| 175 | Material and lanour for MCCB TP NL LT 415 volt 50 Hz, AC 250 amps 25 KA with thermal magnetic release for OL & SC protection complete all as specified and directed |
| 176 | Supply only Thermal Over load relay ofrating 6- 10 Amps, 3Ph, 415 Volts, as existing complete all as specified and directed . |
| 177 | Supply only Thermal Over load relay ofrating 20- 33 Amps, 3Ph, 415 Volts, as existing complete all as specified and directed . |
| 178 | Supply only Electronic timer switch 3 to 120 Sec of 240/415V, 50 Hz , as existing complete all as specified and directed |
| 179 | Material and labour for replacement oftimer switch as existing for running air compressor alternately include electric connections complete all as specified and directed. |
| 180 | Supply and fix in replacement of cast iron suice valve 100 mm dia both side flanged PN-1.6 conforming to IS 14846 (ISI marked) with stainless steel spindle and iron wheel non raising type including, nuts and bolts. complete all as specified and directed. |
| 181 | Supply and fix in replacement of cast iron non return valve 100 mm dia both side flanged (ISI Marked) confirming to IS 5312 (Pt-I) including nut & bolts.complete all as specified and directed. |
| 182 | Supply and fix in replacement of stainer valve 100 mm dia both side flanged (ISI Marked) confirming to IS 5312 (Pt-I) including nut & bolts.complete all as specified and directed. |
| 183 | Material and labour fortaking outcompost /manure from drying filter beds of size 4000X4000X1800mm (04 Nos) by digging / srapingthe all material manually and loading the material into civil truck and sprayed / dumped the manure outside of MOD land whereno disturbanceto human beings will occur and make manurefree up tothe filter media of drying bed complete all as specified and directed. |
| 184 | Taking outchokedmedia filter made from sand, and gravels from drying filter beds of size 4000X4000X1800mm(04 Nos) by digging /scrapingand collect thematerial manually/Special T&P avoid any damage to the drying bedsand make heap properlyfordepositing complete all as specified and directed. |
| 185 | Material and labour for Cement concrete in 1:2:4 type B-1,(using 20 mm graded crushed stone aggregate) as in foundation filling and mass concrete including dismantling of existing concrete complete all as specified and directed. |
| 186 | Taking out the sewage water sample from Raw sewage water/Treated sewage water from STP and carry out the test for 12 parameters as per indian standardspecifications (IS-3025 (Part- 1, 17, 16, 58, 44, 35, 39, 34, 31) & (IS- 1622) from Govt approved lab or NABL accreded lab complete all as specified and directed. |
| 187 | Taking down old UNSV pipe and Supply and fix PVC pipe (SWR pipe) of pressure rating 6 kgf/cm2 laid in trenches with all fittings laid in trenches/fixed to walls complete of size 75mm dia. complete all as specified and directed. |
| 188 | Taking down old UNSV pipe and Supply and fix PVC pipe (SWR pipe) of pressure rating 6 kgf/cm2 laid in trenches with all fittings laid in trenches/fixed to walls complete of size 150mm dia. |
| 189 | Taking down old valve and Supply & fixing Butterflyvalve flanged type, confirming to IS 14846 suitable for 150 mm bore pipe complete all as specified. |
| 190 | Taking out the acummulated sludge/mud mixed and Cleaning/desludging of raw sewage in under ground sump well up to the depth of 8 Mtr inclduing screening chamberand various sewage pumping installation by closing main incoming manhole and pumping out raw sewage to neat drain by using portabale non clog pump set, cleaning of raw sewage sump by manually or mechanically using (spl T&P such as movable sewage cleaning tanker) scrapping inside wall and bottom by steel wire bush to remove rawmaterial and transport it to out side the STP complex & outside cantonment areafor disposal at low lying area up to the distance of 10 Kms at his own arrangment where the sanitary hazard do not take place and as per guidelines of civil authority all as directed for disposal. Thereafter cleaning/washing of interirer surface of UG sump using high grade bleaching powder and lime mixed water incl painting with two coat of cement based paint complete in all respect all as specified and directed by Engineer-in-charge.Detail of Locations : D & E Block Sewage sump Note : 1. Sludge to measured after dewatering /semi drying. 2.Necessary saffety eqpt/ saffety measure to be taken during execution of work. |
| 191 | Cleaning of sewage pipe lines in any depth (0.60 m to 6.00 mtr) of size 100/150/200/300 mm bore laid in trenches by HydraulicJet pressure machine as required at site flushing the line to make fully functional line upto entire satisfaction of Engr-in-charge and removing sludge outside cantonment area with in 10 Kms distance for disposal at low lying area at his own arrangment where the sanitary hazard do not take place and as per guidelines of civil authority all as directed and covering the same.(NOTE: Unit rate quoted by the bidder shall include taking out sludge from line (liquid/semi-liquid/solid), Extraction of Sludge, removing incl loading / unloading & tranportation, excavation and returning filling etc.) |
| 192 | Material and lanourfor cleaning/lifting of sludge by taking out submersible non clogging pump sets from sewage well including dismantling all connections and keeping aside for reinstalling after comprehensive cleaning of sewage treatment plant reservoirs at Phase-II area such as collection cum equalization tank, CC tank, tube settler tank and clear water sump by dewatering and removal of existing sludge from various chambers and scrapping off after draining out waste/sludge and depositing to a suitable location as directed at site, cleaning of all reservoirs mentioned above using bleaching powder and wire brush and wiping off properly including sun drying before re commissioning at site complete all as specified and as directed. Note: Proper shut down shall be taken before commencement of subject work |
| 193 | Material and lanour for lifting of submersible non clogging pump set ofcapacity upto 12.5 HP from sewage well including dismantling all connections and keeping aside for reinstalling after comprehensive cleaning of sewage well by extracting complete sewage settlements/sludge/mud/waste particles and disposal at a distance not exceeding 50 metre from the sewage pump house complete to the entire satisfaction of Engr-in-charge complete all as specified and as directed. |
| 194 | Taking out old UNSV MS Angle/ channel/ Sheet from Open well & Jack well sumps and supply & fabricated MS Covers from 50x50x6mm thck MS Angle Iron frame, MS sheet of size 3mm thick, MS rods, (Fe.290.Gde-E-165) include handle for lifting completeinclude painting with one coat of Red oxide paintand two coat of synthetic enamel paint as per existing size complete all as specified and directed. (Note : Job include cutting corroded structure by welding, fabrication of new structure by welding, cutting and fixing with suitable arrangements). |
| 195 | Material and lanour for Scrubbing cleaning the exterior surface of OH sewage pump house at STP, 0.9 MLD outer surface complete as existing colour and applying two coats of cement base paint on the outer surfaces and two coats of synthetic enamel paint on electric panel and MS structure , pipe line, air lines etc as per existing colour code include marking with white colour include DI/MS sewage line etc complete all as specified and directed |
| 196 | Material and lanour for Scrubbing cleaning the exterior surface of UG sump and applying two coats of cement base paint on the outer surface and two coats of synthetic enamel paint on ladder fitted from ground to reservoir or MS structure & applying two coat of lime on inner surfaceof wallscomplete all as specified and directed. (Sewage Sump at D & E block) |
| 197 | Material and labour for Dismantling of centrifugal /Non clog submersible sewage pump from inline pump set assembly in theunderground sumpby chain pulley or other mechanical devices and opening of pump, cleaningthe unwanted materials such as brick bats/ stone /cloth pieces/any solid/semisolid /any type foreign materialfrominner portion of the pumpsby opening theall nuts and bolts and refixing and fully alignthe complete pumps on the same existing place and make trouble free as directed by Engineer-in-charge. (Note:- the requiredmaterial such as Grease, cotton waste, Nut , bolt and washer to be deemed in the same job work). |
| 198 | Supply and fixing in replacement of ribbed V Belt of existing size for air blowers complete all as specified and directed. |
| 199 | Taking down old UNSV light fittings andSupply and fixing LED flood light 100watt 230 VAC outdoor type with thermal management inmultiple optics and equipped with IP66 protection, with impact and corrosion resistant include MS bracket , nuts & bolts fixed on wall or OHT pillar, or MS Structure complete with driver and lamp include pipe bracket and MS frame complete all as specified and directed. |
| 200 | Taking down old UNSV fittings and Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 201 | Taking down / up unserviceable XLPE LT cable of size up to 16 Sqmm to 50Sqmm 3-1//4core complete all as specified and directed by Engineer-in-charge. (Note: Earth work to be measured and paid under relavent item of this schedule) |
| 202 | Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade corss-sectional area 50 Sq mm 3.5core complete all as specified and directed by Engineer-in-charge. (Note: Excavation & Thimbles to be measured and paid under relavent items of this schedule) |
| 203 | Taking down existing 2 to 4 core UG cable disconnect from panel board, proper dressing, replacement of cable lugs of appropriate size and refixing the same in porperly complete all as specified and directed. |
| 204 | Material and labour for PCC 1:3:6 type C-2,(using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete including dismantling of existing concrete complete all as specified and directed. |
| 205 | Material and lanour for taking out existing filter media from Iron removal plant or Pressure fillter of cap 6000 GPH of any description carefully and removing out to distance 50 Mtrs away from pump house, including cleaning, washing inside of filter including painting Inside & Outside, replacement of UNSV PVC threaded hose pipe, rubber washers, Nuts & Bolts , testing and comissioning complete all as specified and directed. |
| 206 | Supply and fix and leveling gravel of size 20 x 12mm thickness as per OEM design complete all as specified and directed. |
| 207 | Supply and fix and leveling gravel of size 12 x 6mm thickness as per OEM design complete all as specified and directed. |
| 208 | Supply and fix and leveling gravel of size 6 x 3mm thickness as per OEM design complete all as specified and directed. |
| 209 | Supply and fix and leveling gravel of size 3 x 1.5mm thickness as per OEM design complete all as specified and directed. |
| 210 | Supply, laying andand levelling Activated carbon (Arthritic coal) as per OEM design for forming media filter of filter complete all as specified andas directed . |
| 211 | Supply and fix and leveling fine sand of size 0.45mm to 1mmas per OEM design complete all as specified and directed. |
| 212 | Servecing of Rotary air blower Make : Swam Pneumatics capacity 700 CuM/Hrs, Pressure 6500 WG Speed 1600 RPM with 30 HP Motor complete in various location, servicing, repairing and replacement ofparts, calibration, oil replacement, Complete all as specified and as directed . |
| 213 | Supply and fixPVC threaded pipe 15mm dia include clips as per sample for filters . |
| 214 | Note for item No. 146To 213 :(a) The cleaning will be done as per mechanisedprocess and results will be verified by the competant authority. (b) The notice for the interruption of sewage boosting/sewage treatment shall be intimated to the concerned Engineer In Charge prior to execution of the work and and the process shall be completed within 24 hours of begining the work to avoid inconvenience in the effected areas. In case the contractor fails to complete the complete cleaning process and resuming the services within 24 Hours , panel recovery ofRs 5000.00 per day will be recovered for the job effected forwhich the contractor shalll not have any extra claim whatsoever from the Dept..(c)The unit rates quoted by the contractor shall be deemed to be inclusive of Writing date of cleaning in white letters of size as directed on black background.(d) Rates include T&P, any charges include permission from GHMC or municipal corp and staging requiredfor the job in the quoted rates against BOQ items nothing extra not to be paid on this account.(e)Necessary saffety equipments, saffety measure should be strictly maintained by the persons employed in the work during execution of work as per norms or as directed or required at site during execution of work.Competent person should be present during execution of work.(f) The complete work will be carried by or in persons supervision of qualified engineer or other professional agency for doing such type of work rates to be included in the quoted rates. (g) All waste material/ sludge /mud/ muddy sand retrieved after repair/ cleaning worksto be removing from site and dispossed off in low lying area out side the cantt.Rates of transportation to be included in the quoted rates. If contractor fails to doing the job a panel recovery of Rs 3000.00 will be recovered from the job effected forwhich the contractor shalll not have any extra claim whatsoever from the Dept..(h)Cleaning of sewage sumps be carried out though mechinical means by hydrolic suction machines and strictly \"NO MANNUAL\" cleaning be permitted as per policy. Rates for spl T&P be included in the quoted rates. |
| 215 | Taking down old UNSV UG cable and Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade corss-sectional area 16 Sq mm 4core complete all as specified and directed . |
| 216 | Taking down old UNSV and Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 6 sqmm complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail