| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources,Portland Pozzolana / Ordinary Portland /Portland Slagcement,admixtures in recommended proportions as per IS: 9103 to celerate /retard setting of concrete, to improve durability andworkabilitywithout impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering, finishing andeinforcement as per direction of the engineer-in-charge;for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade withminimum cement content of 330 kg /Cum. |
| 10 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources,Portland Pozzolana / Ordinary Portland /Portland Slagcement,admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability andworkabilitywithout impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge;for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level Concrete of M25 grade withminimum cementcontent of 330 kg /cum |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 12 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 13 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 14 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Sal wood |
| 15 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 16 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 17 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 18 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick |
| 19 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 100mm |
| 20 | Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. |
| 21 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. - Hot finished welded type tubes |
| 22 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.- In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works |
| 23 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 24 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/Sqm including grouting the joints with white cement and matching pigments etc. The iles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 1200 mm |
| 25 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 75mm |
| 26 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 27 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5°75 mm bend |
| 28 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend |
| 29 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 30 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per Sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) |
| 31 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per Sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws completeGutter (600 mm over all girth) |
| 32 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 33 | 15 mm cement plaster on rough side of single or half brick wall of mix: - 1:6 (1 cement: 6 coarse sand) |
| 34 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre |
| 35 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm) |
| 36 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : - Two or more coats on new work |
| 37 | French spirit polishing : - Two or more coats on new works including a coat of wood filler |
| 38 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 39 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. - Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 40 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 41 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. - In cement mortar |
| 42 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below |
| 43 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 44 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 45 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 46 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 47 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 48 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 mm |
| 49 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings withne step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes |
| 50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall25 mm nominal dia Pipes |
| 51 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work,50 mm nominal dia Pipes |
| 52 | Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length, 15 mm nominal bore |
| 53 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 54 | Providing and fixingwall hung bowl Water closet Jaquar or equivalent make , Model-(J-ARS-WHT-39951UFSM) with fiting as complete specified and directed by Engg-in-Charge. |
| 55 | Providing & fixing concealed cistern Jaquar or equivalent make ,Model No.- J-JCS-WHT-2400) complete set with flush control plate make of Jaquar or equitable or equitable Continental Prime in the wall with all fittings and fixtures complete specified and directed by Engg-in-Charge. |
| 56 | Providing & fixingCounter topfixed wash basin Jaquar or equivalent make model no. JDS-WHt-25907N as per specified and directed by Engg-in-Charge. |
| 57 | Providing and fixing Jaquar or equivalent make model no. J-ARI-CHR-39053 Angle valve as per specified and directed by Engg-in-Charge. |
| 58 | Providing and fixingBib cock Jaquar or equivalent make Model no. (J-ARI-CHR-39037) as per the direction of Engineer-in-charge. |
| 59 | Providing and fixingWash basin spout with Concealed body Jaquar or equivalent make Model no. (J-ALD-CHR-441) as specified and directed by Engg-in-Charge. |
| 60 | Providing & fixing urinal Ceramic - Vitreous China of size (375x320x620mm) with fixing accessoriesJaquar or equivalent make Model No.- (URS-WHT-13253N) specified and directed by Engg-in-Charge. |
| 61 | Providing and fixing Urinal flush/stop cock with Concealed bodyJaquar or equivalent make model No. (J-ALD-CHR-083/J-ARI-CHR39083K ) as per specified and directed by Engg-in-Charge. |
| 62 | Providing and fixing wall hung SS Soap Disppenser Jaquar or equivalent make of Model No(.AKP-BCH_35735p)as per specified and directed by Engg-in-Charge. |
| 63 | Providing and fixing ISI marked S.S. handles with necessary screws etc all complete as specified and directed by Engg-in-Charge.300 mm |
| 64 | Providing & fixingToilet Cubicle (of following standard dimension which includes 600mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12mm thick solid compact laminate panels tested by Shriram Test House. Finish of the compact laminate should be Suede/ *Raw as per fire retardant BS-476/97 standard. The product should have Green Guard Certificate.This also includes providing and fixing in position necessary hardware made out of Stainless steel (Grade 304) as per manufacturer\"s specifications & Architects instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset with Occupancy indicators, (4) Coat hooks with Door stopper (5) U-Channels, (6) Adjustable foot/pedestal, (7) Top rail with Corner conntector (8) Rubber noise deafening tape, (9) Screws & wall Plugs.The top fitting should consist of SS round top rail which will get fixed with pilasters, with SS panel tube holder, SS corner bend (connected with top rail) will be used on the corner of cubicle in absence of brick wall, SS wall fixing is used only on the wall which will hold the ss top rail.All screws will of 304 Grade in stainless steel with satin finish. All pilasters are supported by stainless steel Bottom Cladding. The base of the stainless steel bottom cladding will be anchored to the floor with a clearance height upto 150mm.Toilet cubicle with standard dimension of 2025mm height x 1000mm width 1550mm depth wich inclues 600mm doors size width. |
| 65 | Providing and fixing ISI marked S.S. pedistal for Cabinet with necessary screws etc all complete as specified and directed by Engg-in-Charge.100 mm |
| 66 | Providing and laying Vitrified tiles in Wallin different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/Sqm including grouting the joints with white cement and matching pigments etc. The iles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed vitrified floor tiles polished finish of sizeSize of Tile 600 x 1200 mm |
| 67 | Providing and fixing 50 mm thick sandwich roof puff panel(factory made only) as per specification as follow.A) Outer sheet;0.50 mm (TCT)precoated galvanizedtrapezoidal steel sheet havingminimum 30mm crest depth, polyester top coat & alkyd backer. Zinc coating shall be120gsm as per IS-277.Top coatpolyester 15-18 microns over5-7 micronepoxy primer B) Insulation: High density puff insulation C) InnerSheet:Colour coated galvanized , slightly ribbed.Thickness0.50 mm (TCT) minimum 15-18 micron top coatpolyestercoating , Zinc coating120g/Sqmas per IS-277 Grade of steel:Minimum 240 Mpa (both sheets).Sheetshould haveprotective guard film of 25 micronminimum to avoid scretchesduringtransportations and shouldbe suppliedinsinglelengthupto12 meteroras desired by Engineer-in Charge.The sheet shall be fixed using self drilling/selftappingscrews with EDPMseal, completed uptoany pitch in horizontal/vertical or curved surfaces excluding the costpurlins, rafters andtrusses and includingcutting to size and shapewhereverrequired.Work to be executed as per theinstructions of Engineer-in-Charge. |
| 68 | Providing and fixing wall hung SS Paper Holder With Flap Recessed Type Jaquar or equivalent make of model No. (AKP-35753PS) as perspecified and directed by Engg-in-Charge. |
| 69 | Provided and fixing 3mmAcrylic Demarcation board for Toilet doorswith necessary screws etc all complete as specified and directed by Engg-in-Charge. |
| 70 | Providing and fixing SS Grab bar 300mm Long Jaquar or equivalent make model No. (CN-1101S ) as per specified and directed by Engg-in-Charge. |
| 71 | Providing and fixing 3M TM Scotchal Electro Cut Dusted crystal (Acid etched look-7725SE-314) / Frosted crystal (Sand Blasted look-7725SE-324) Graphic Film over the designated locations with wet applications at all floors in any design and pattern complete as per the direction and satisfaction of Engineer-in- charge. (No deductions shall be made for the blank areas in the pattern). (For Technical details refer Item specification). |
| 72 | P/F S CI 100mm dia trap of approved make complete as per direction of Engineer-in-charge |
| 73 | P/F P CI 100mm dia trap of approved make complete as per direction of Engineer-in-charge |
| 74 | P/F C.P. bottle trap for wash basin 32mm Size with 250mm and 190mm long wall connection pipes and wall flange of Jaguar Make (Cat ALD-769L Size 250x190) etc. complete or equivalent as per satisfaction of Engineer-in-charge |
| 75 | Providing and fixing C.P. brass waste for sink or washbasin etc. complete as per the direction of EIC.40 mm dia. |
| 76 | Providing & fixing SS grating 100mm dia of openable type complete as per direction of Engineer-In-Charge |
| 77 | Providing and Fixing 10 MM frameless self standing toughened glass of required height and length with mirror polished edges ,fixed as per specified lay out with patch fittings fixed as and where required ,specially ordered Stainless steel patch fittings as legs,tees,junctions,angles,glass to glass connectors,wall to glass connectors,L angle connectors,2 way glass connectors with SS patti with double sided bolt including all Stainless steel bolts with nuts etc used as and where required as per layout plan,glass to be of required length with proper support with all gaps filled with silicon sealent ,Glass to have holes/cut outs to accomodate patch fittings,all complete as per entire satisfaction of Engineer in charge (NET AREA OF GLASS TO BE MEASURED FOR PAYMENT PURPOSE) |
| 78 | Providing and Fixing health faucet with 1.2 m long pvc tube Chrome Finish and wall hook of Jaguar Make (Cat ALD-563) etc. complete orequivalent as per satisfaction of Engineer-in-charge. |
| 79 | Providing and fixing 18 mm thick commercial Board in partitions paneling and for other works including fixing with necessary screws, nails etc. as per the direction and satisfaction engineer-incharge. |
| 80 | Providing and fixing 6 mm thick plywood in partitions paneling and for other works including fixing with necessary screws, nails etc. as per the direction and satisfaction engineer-in-charge. |
| 81 | Providing and fixing 6 mm thick beveled edge looking mirror of superior glass (of approved quality) in required size and shape fixed with SS stud etc complete as per satisfaction of EIC. |
| 82 | Providing and fixing CPVC Gate valve 25mm complete as per the direction of Engineer-in-charge. |
| 83 | Providing and fixing CPVC Gate valve 20mm as per the direction of Engineer-in-charge. |
| 84 | Deduct for taking away of C.P. brass/Brass bib cock, stop cock, long body bib cock, long nose bib cock, angle valve, ball valve, close hole basin mixer, C.P. waste in basin/ sink and the like received from dismantling. The material so received shall be the property of contractor after dismantling duly weighed/measured before removing from the site in the presence of Engineer-incharge or his authorised representative all complete. (Rates mentioned shall be fixed above/below % age quoted by the contractor shall not be applicable on this item) |
| 85 | Deduct for taking away of aluminium butt hinges, sliding door bolts, tower bolts, pull boly lock, handle, door stopper, casement stay, tee chanals, plates, frames, shutters, partition, tubular sections etc. and the like received from dismantling. The material so received shall be the property of contractor after dismantling duly weighed/ measured before removing from the site in the presence of Engineer-in-charge or his authorised representative all complete. (Rates mentioned shall be fixed above/below % age quoted by the contractor shall not be applicable on this item) |
| 86 | Deduct for taking away of steel work in frames, shutters, trusses, channels, beams, Tee, angles, bolts, washers etc. and the like received from dismantling. The material so received shall be the property of contractor after dismantling duly weighed/ measured before removing from the site in the presence of Engineer incharge or his authorised representative all complete. (Rates mentioned shall be fixed above/below % age quoted by the contractor shall not be applicable on this item) |