| 1 | Repair/maintenance and servicing & Over hauling of water cooled/ air cooled DG Set including replacing engine oil, greasing and oiling, checking of valve & nozzle, changing of diesel filter, oil filter,Piston,CR bearing,Liner,Fuel Pump checking of defective parts complete, re-commissioning and testing complete allas specified and directed for the following capacities:- |
| 2 | 30 KVA at Averipatti |
| 3 | 10 KVA at Jhakri |
| 4 | 50 KVA at Karcham |
| 5 | 30 KVA at Poari |
| 6 | 50 KVA at Pooh |
| 7 | 160 KVA at Pooh |
| 8 | 10 KVA at sumdo |
| 9 | 30 KVA at sumdo |
| 10 | 12 BHP -01Nos . Diesel engine pumpset at sumdoNote :- Spare parts like filters, engine oil and other spares shall be measured and paid separately as supply only under relevant items of Sch \"A\"/BOQ.Fixing/ labour charges for replacement of spares deemed to be included in the unit rate quoted. |
| 11 | Supply only element diesel filter with gasket of existing size and model complete all as specified and directed. |
| 12 | Supply only element oil filter with gasket of existing size and model complete all as specified and directed. |
| 13 | Supply only inner and outer air cleaner element of existing size and model complete all as specified and directed. |
| 14 | Suppply only element bypass filter with gasket of existing size and make complete all as specified and directed. |
| 15 | Supply only Liner for DG setof existing size and model complete all as specified and directed. |
| 16 | Supply only Piston forDG Set of existing size and model complete all as specified and directed. |
| 17 | Supply only CR Bearing forDG Set of existing size and model complete all as specified and directed. |
| 18 | Supply only Fuel Pump forDG Set of existing size and model complete all as specified and directed. |
| 19 | Supply only Assembly forDG Set of existing size and model complete all as specified and directed. |
| 20 | Supply only lubrication oil SAE-40 (20w-40 grade) complete all as specified and directed.Make : Servo/HP/BPCL/Castrol) |
| 21 | Dismantling/In situ Cleaning and calibration of the fuel tank of various capacities, by using \"K\" oil and remove sludge accumulated inside the tank, replacment of feul tank strainer, cap and unserviceable fuel indicatior including refixing after repair/welding the leakage portions complete all as specified and directed by Engr-in-Charge |
| 22 | S&F connecting and testing battery lead (Heavy duty) PVC insulated with multi stranded copper conductor single core of size 25 sqmm one side fixed with clamp and other side fixed with brass battery terminal for 2 mtr length suitable colour coding for phase and earth complete all as specified and directed |
| 23 | S&F in replacement of battery maint free type 65Ah complete all as specified and directed .Make: Exide/Amaron/TATA |
| 24 | S&F in replacement of battery maint free type 100Ah complete all as specified and directed . Make: Exide/Amaron/TATA |
| 25 | Disconnecting & taking out the non-functional voltage stabilizer of any description and in any position & opening of servo operated oil cooled voltage stabilizer of cap 30 KVA , single/three phase, 50 Hz and draining out of transformer oil, replacement of UNSV/defective wiring parts as per existing sizes, dimmerstat, carbon brush, servo motor of existing capacity, control card, etc and complete servicing including filteration & refilling of transformer oil with top-up of new oil if required, reassembling, connecting and testing complete all as specified and directed by Engr-in-Charge |
| 26 | All as per item No. 16 here in before but capacity 100 KVA, three phase |
| 27 | All as per item No. 16 here in before but capacity 150 KVA, three phaseNote for Item No. 16, 17 & 18:- Replacment of spare parts/accessories shall be measured & paid seperately as \"Supply Only\" on relevant items. |
| 28 | Supply only Dimmerstat as per existing size and make complete all as specified and directed |
| 29 | Supply only Servo control motor Cap 10 Kgs, 60 RPM & 240 volts for existing voltage stabilizer as per existing size and make complete all as specified and directed. |
| 30 | Supply only Push Buttons for adjustment of voltage complete all as specified and directed |
| 31 | Supply only Carbon brush as per existing size and make complete all as specified and directed. |
| 32 | Supply only voltmeter digital type, 0-500 volts, 96mm x 96mm square size including wiring, suitable for voltage stabilizers complete all as specified and directed.Make: AE/L&T/Seimens |
| 33 | Supply only indicator lamp pilot type (RYB) complete all as specified and directed. |
| 34 | Supply only selector switch suitable for voltmeter, 3 way, ON/OFF type complete all as specified and directed.Make : GEPC/PAAS/Concord/Vaishno/Legrand Lexic |
| 35 | Supply only AVR card as per sample complete all as specified and directed. |
| 36 | Supply only Transformer oil EHV conforming to IS-335 of 1983 having high dielectric strength not less than 50KV in drums/barrel complete all as specified and directed. |
| 37 | S&F in replacement of Heating element, 3 KW, ISI marked, copper sheathed, nickel plated suitable for any type, make, size of solar water heaters, complete all as specified and directed. |
| 38 | Servicing of window/split AC 1.5/2 TR capacities any make by opening the indoor/outdoor unit, cleaning the air filter, condenser including complete bodyof the unit with brush and air blower, washing with cleaning detergent & fresh water, greasing fan motor, rectification of loose electric connections and replacement of unserviceable knobs of electrical items complete all as directed(Note : Replacement of spare parts will be measured and paid separately under relevant items of BOQ under Supply only.) |
| 39 | Supply only starting capacitor 80-100 mfd as per the existing make |
| 40 | Supply only running Capacitor 36 mfd as per the existing make |
| 41 | Supply only starting relay as per the existing make |
| 42 | Supply only Over load protector as per the existing make |
| 43 | Supply only thermostat as per the existing make |
| 44 | Supply only Air Filter as per the existing make |
| 45 | Removing the existing defective / short circuited hermetically sealed compressor unit from the ACs and replace with the same company rewoundsealed compressor unit of appropiate make / model for 1.5 TR AC complete all as specified and directed |
| 46 | Servicing, maintenance and repairsto Refrigerator / Deep Freezerof capacity 280 to 386 Ltrs of any make and model including periodical cleaningto condenser coil and compresser, Replacement of defective spares will be measured and paid separately under relevant items as under complete all as specified and directed Note : Replacement of spare parts will be measured and paid separately under relevant items of Sch \"A\" |
| 47 | S&F in replacement Starting Relay complete all as specified. |
| 48 | Removing the existing defective/short circuited hermetically sealed compressor unit from the Refrigerator, Replacement of the same with company rewound sealed compressor unit of appropriate make / model for Refrigerator cap: 280 to 380 ltrs complete all as specified and directed |
| 49 | Gas charging with refrigerantto ACs/water cooler/Deep freezer /Refrigerator including arresting of existing leakage by brazing work complete and all as specified and directed |
| 50 | M&L for servicing, cleaning of water purifier 8/10 LPH, any make & model complete all as specified and directed.Note: Replacement of following items shall be measured & paid separately as \"Supply only\" |
| 51 | Supply only Sediment filter |
| 52 | Supply only Carbon filter |
| 53 | Supply only UV filter |
| 54 | Supply only Membrane |
| 55 | Supply only Pre-filter candle |
| 56 | M&L for servicing, cleaning of Industrial type RO plant 50 to 100 LPH, any make & model complete all as specified and directed.Note: Replacement of following items shall be measured & paid separately as \"Supply only\" |
| 57 | Supply only pressure regulator |
| 58 | Supply only Sediment Pre-filter |
| 59 | Supply only Carbon filter |
| 60 | Supply only RO membrane |
| 61 | Supply only Post Caron inline filter |
| 62 | Supply only Pressure pump booster |
| 63 | S&F in replacement of Rigid steel conduit, welded complete all as specified and directed. |
| 64 | S&F in replacement of Cable PVC insulated and FR PVC round sheathed copper conductor 2 core AC 1100 Volts grade 1.5 sqmm size and required flexible conduit etc all as specified and directed. |
| 65 | S&F in replacement of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including connecting to junction box andfixing of light fitting to existing GI bracket painted in silver colour & steel clamps complete with accessories suitable for fixing to the RCC LT Pole of 9 mtr complete all asspecified anddirected. |
| 66 | Painting to existingof steel poles 11/9 Mtr long long with one coat of synthetic enamel paint in alternate strips of blackand yelow colours 30 cm height each total 05 Nos commencing form the top of PCC coping incuding painting of coss arms, nut bolts, clamps etc as fixed on pole with tow coats of aluminium paint and marking pole No with paint as per approved pattern, complete all specified (Numbring shall be hand written only, size of letter 100X10mm (Heightxwidth)) |
| 67 | Material and labour for providing PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in platform, filling and mass concrete, coping etc complete all as specified ansd as directed. |
| 68 | Supply only constant current led driver suitable upto 35 watt LED bollard/post of lantern light complete all as specified and directed. |
| 69 | Supply only constant current led driver suitable for 45 to 60 watt LED street light complete all as specified and directed. |
| 70 | Supply only constant current led driver suitable for 70 to 100 watt LED street/flood light complete all as specified and directed. |
| 71 | Supply and fixing in replacement LED Flood light 100 Watt 230 V AC with high pressure die cast aluminum hosing and heat resistant complete with driver,corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. all as specified and directed. |
| 72 | Supply and fixing in replacement LED Flood light 70 Watt 230 V AC with high pressure die cast aluminum hosing and heat resistant complete with driver,corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. all as specified and directed. |
| 73 | S & F in replacement ofLED bollard fitting 7.5 watt 230 volts AC outdoor type suitable for ground/wall mountedcomplete all as specified and directed |
| 74 | M&L in replacement for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth strip25x4 mmprotected by GI pipe light grade 40mm dia, 20 mm medium grade for watering with funnel including test point up to 7.5 meter from earth pit, common salt, charcoal dust and connected to test point by means of bolts and nuts washers made out of GI all as shown in Electrical plate No 3 of SSR part I includingnecessary earth work and excavation in any type of soil, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type mix cover slab with 6mm dia MS bars at 100mm dia both ways with MS hook 6mm dia MS bars etc. complete all as specified and directed by Engr-in-charge.Note: 1. Suitable quantity of charcoal, common salt, funnel, GI pipe required for watering, pit & CI pit cover etc is deemed to be included in quoted rate and lead wire used beyond 7.5m from pit cover will be measured separately.2. On testing after completion if the desired resistance is not obtained the earthing shall be re-done at no extra cost. |
| 75 | S & F in replacement of solar street light fitting 12 watt having high efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller and Aluminium Extruded body & specially programmed to automatically control the dimming and brightness of light, which increases the backup time, etc including fixing on existing pole complete all as specified and directed |
| 76 | S & F in replacement of solar street light fitting 15/16 watt having high efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller and Aluminium Extruded body & specially programmed to automatically control the dimming and brightness of light, which increases the backup time, etc including fixing on existing pole complete all as specified and directed. |
| 77 | S&F in replacement of battery maint free type 110Ah suitable for solar light fitting complete all as specified and directed. |
| 78 | Supply and fix in replacement of 2 core 1.5 Sqmm PVC FRLS insulated multi copper cable for connection of street light complete all as specified and directed. |
| 79 | Supply and fix in replacement PVC conduit pipe 20 mm medium grade ISI marked complete all as specified and directed by Engr-in-Charge |
| 80 | Supply and Fixed in replacement, street light fitting 30 Wnew generation energy saving and enviromental friendly long life made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom opening seperate driver compartment with IP66 protection and impact resisitance of IK08 complete all as specified and directed by Engr-in-Charge.Make :-Havells / CG / Wipro |
| 81 | Supply and Fixed in replacement, street light fitting 45 Wnew generation energy saving and enviromental friendly long life made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom opening seperate driver compartment with IP66 protection and impact resisitance of IK08 complete all as specified and directed by Engr-in-Charge.Make :-Havells / CG / Wipro |
| 82 | Supply and fix in replacement with solar LED Gate lightin aluminium die cast with morden artistic design and whiteof suitable size complete all as specified and directed by Engr-in-Charge.Make - Havells or eqvt in CG/Wiprro |
| 83 | Supply and fix in replacement with LED Gate light Round in aluminium die cast with morden artistic design and white PC diffuser suitable with LED Lamp B22 including3 core PVC copper wire of suitable size complete all as specified and directed by Engr-in-Charge.Make - Havells or eqvt in CG/Wiprro |
| 84 | Supply and fix in replacement ofLED bollard light fitting8/10 watt new generation, energy saving, enviromental friendly, long life aesthetically designed aluinium landscpe IP 65 luminaire for diffused lightig with high power LED as light source including3 core PVC copper wire of suitable size complete all as specified and directed by Engr-in-Charge.Make - CONEBLS8WLED830PSYMTOPC of Havells or eqvt in CG/Wiprro complete |
| 85 | Supply and fix in replacement of decorative gate light Moon 200 (OPAL), made up of high grade unbreakable polycarbonate material suitable of retrofit LED lamp B22 base complete all as specified and directed.Make -Opal LHFXBON1TN5Q014 of Havells or eqvt in CG/Wiprro complete |
| 86 | Supply and fix in replacement of All-in-one Solar Street street Light of 20 W LED NG series AIO solar street light is made with high efficiency mono crystalline solar PV module, lithium Ferro phosphate battery with in-built BMS technology, high efficacy LED, MPPT solar charge controller and aluminum extruded body and is specially programmed to automatically control the dimming and brigthness of light, which increases the backup time and system volt 12V/24V. Including Powder coated MS Round Pole of 5 mtr height, necessary excavation and PCC Work & removal of soil complete all as directed.Make : Cat No -SOLAR AIO 20 W of Havells and eqvt in Philips and Wipro |
| 87 | Supplying, laying, jointing & testing in replacement of cable XLPE insulated as per IS 7098(Part-I)-1988, marked, screened, PVC sheathedarmoured electric power cable ( heavy duty) with aluminium conductor for working voltage upto and including 1100 Volts croos sectional area 10 Sqmm 4 core with aluminium stranded, laid in trenches / fixed on pole / wall / passed through pipe complete all as specified and directed by Engineer - in - Charge, Make : Havells / Polycab / Plaza / KEI / GLOSTER. Note :- Road cutting involved any to be made with PCC. |
| 88 | All as per item No - 78 but 16 Sqmm 4 Core |
| 89 | All as per item No - 78 but 25 Sqmm 4 Core |
| 90 | Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr in depth in any type of soil for laying underground cables / erection of steel tubular poles / stay pit etc all as specified and directed by Engineer - in - Charge. |
| 91 | Returning and filling in two parts (i) using riddled soil obtained from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil complete all as specified and directed. |
| 92 | Removing excavated surplus material to a distance n exc 50m and depositing where directed at level n. exc 1.5m above the starting point in any type of soil complete all as specified and directed by Engineer - in - Charge. |
| 93 | M & L for laying dry bricks old size with sub class \"B\" made of burnt clay best quality locally available with permissible tolerance , laid straight in trench for protection of cable all as specified and directed by Engineer - in - Charge. |
| 94 | Supply and Fix terminal box made out of PVC Sintex box with hinged door and locking arrangements of size 240x130x95 mm including four way connector, fixed on pole with necessary clamps complete all as directed.Make - Sintex |
| 95 | Schedule of Credit |