| 1 | M&L for repair and maint of Gyserfor (any type/ make/size of geysers)/complete servicing of geyser including dismantling electric and water connection of the geyser, taking down from its position on ground,dismantling geyser complete such as removing tank from its outer body, removing apparatusplate/ syphon assembly from the tank, glass wool, descaling the geyser inner tank, testing its thermostat, heating element , and leakage from tank , reassembling the geyser,replacement of unserviceable parts such as heating element, thermostat, indication lamp, plug top , three core wire, rubber gasket, inner tank, outer cover, glass wool, split plate/ Bottom cover plate,apparatus plate/ syphon assembly if required and all other connected items (Spares will be measured and paid seperately under relevant item of the Sch as Supply only ) testing the geyser and installation of the geyser into its original positionand connecting all electric and water supply connection etc., complete all as specified and directed by Engineer-in-Charge .Note: (a) All repair shall be carried out by the contractor at his own expenses for efficient functioning.Contractor is advised to visit the site to ascertain the model and manufacturer of system before quoting his rates.(b) Rate quoted by the contractor shall deemed to be included for making good the worn out nut bolts, washers, union socket, flanges and screws etc. |
| 2 | Supply only in replacementHeating element 240 V ACsingle phase of capacity 2 KW (Circular/Triangular) for any type make size of Geysers (as per site requirement) , complete all as specified and directed by Engineer-in-Charge . ( Make Theeta/Escorts/ISI marked) |
| 3 | Supply only in replacementHeating element 240 V ACsingle phase of capacity 1.5 KW (Circular/Triangular) for any type make size of Geysers (as per site requirement) , complete all as specified and directed by Engineer-in-Charge . ( Make Theeta/Escorts/ISI marked) |
| 4 | Supply only in replacementHeating element 240 V ACsingle phase of capacity 2 KW including thermostat for Geysers of Make Bajaj/ Racold/Usha/ Venus, complete all as specified and directed by Engineer-in-Charge . ( Make Theeta/Escorts/ISI marked) . Note: Contractor is advised to visit the site and check for element before quotting the rate so that the contractor can ascertain the type of element that need to be fitted on Ground. |
| 5 | Supply only in replacement thermostat switch, ISI marked forGeysers of any capacity size type & make (as per site requirement)etc, complete all as specified and directed by Engineer-in-Charge. |
| 6 | Supply only in replacement indicating lamps 230 volts square/roundforGeysers of any capacity size type & make (As per site requirement) etc, complete all as specified and directed by Engineer-in-Charge. |
| 7 | Supply only in replacement flexible cable conductor 3 core, 2.5 sqmm and connecting electrically to Geysers of any capacity size type & make etc, complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supply only as in replacement Geysers inner tank made out of 16 gauge stainless steel sheet for 25 litre capacity Geysers of anytype & make etc , complete all as specified and directed by Engineer-in-Charge.Note: The tank shall be tested at site and should be able to withstand the requisite hot water pressure. Necessary testing equipments shall be arranged by the contractor. |
| 9 | Supply only as in replacement Geysers inner tank made out of 16 gauge stainless steel sheet for 50 litre capacity Geysers of anytype & make etc , complete all as specified and directed by Engineer-in-Charge. Note: The tank shall be tested at site and should be able to withstand the requisite hot water pressure. Necessary testing equipments shall be arranged by the contractor. |
| 10 | Supply only as in replacement syphon assembly (as per site requirement) made out of stainless steel with water inlet and outlet, rubber gasket, nuts, bolts, washer and complete accesories of required size for 25 litre Geyser of any size , type , make etc, complete all as specified and directed by Engineer-in-Charge. |
| 11 | Supply only as in replacement syphon assembly (as per site requirement) made out of stainless steel with water inlet and outlet, rubber gasket, nuts, bolts, washer and complete accesoriesof required size for 50 litre Geyser of any size , type , make etc, complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supply only as in replacement outer cover made out of MS sheet for 25 litre Geyserduly fitted with side cover and bottom cover plates complete painted with one coat of synthetic enamel (white) paint over one coat of red oxide primer after preparing the surface , complete all as specified and directed by Engineer-in-Charge. |
| 13 | Supply only as in replacement outer cover made out of 22 Gauge MS sheet for 50 litre Geyserduly fitted with side cover and bottom cover plates complete painted with one coat of synthetic enamel (white) paint over one coat of red oxide primer after preparing the surface, complete all as specified and directed by Engineer-in-Charge. |
| 14 | M&L forbrazing / soldering workwith copper brass alloy to rectifyleakage/cracked of inner copper/Stainless Steel container of storage type electrically operated water heater (Geyser) & testingof inner shell up to the entire satisfaction of the Engr-in- Charge includingreassembling / reinstallingat site etc complete all as directed. |
| 15 | Supply and fix as in replacement PVC Nylon thread connection ( hot and cold type) 45/60 cm long with nut at both ends suitable for 15 mm bore pipe suitable for geyser, complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply only as in replacement glass wool in Geysers vesselof any sizeand capacity, complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply and fix as in replacement non return valve 15mm for geysers (as per site requirement), complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply and fix as in replacement Stop valve cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe of bore 15 mm Chromium plated fancy type complete fixed as in repair, complete all as specified and directed by Engineer-in-Charge.Make : Seiko/GEM/Kingston/SS |
| 19 | Supply and fix as in replacementBib tap cast copper alloy chromium plated, fancy type, with capstain head handle screwed down screwed for iron pipe and fixed fo 15mm bore pipe after taking down of old brass bib tap, complete all as specified and directed by Engineer-in-Charge.Make : Seiko/GEM/Kingston/SS |
| 20 | Supply and fix as in replacement pressure release valve on top ofGeysers, complete all as specified and directed by Engineer-in-Charge. |
| 21 | Supply and fix as in replacement SPN enclosure with two pin and earth metal plug incl MCB SP 20 Amp , complete all as specified and directed by Engineer-in-Charge. |
| 22 | Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 2 way single door type, complete all as specified and directed by Engineer-in-Charge. |
| 23 | Supply and fix in replacement plug top 15 Amp suitable for Geysers of capacity 25/35/50 ltr, complete all as specified and directed by Engineer-in-Charge. |
| 24 | Shifting of geyser of capacity 25/35/50 litre incl anchor bolt ( 12mm X 100mm long)for fixing of geyser on wall , complete all as specified and directed by Engineer-in-Charge. Note: Anchor Bolt should be grouted with Hammer drill only. Rate of anchor bolt (12mm X 100mm long) is deemed to be included in the unit rate quoted by the contractor. |
| 25 | Supply only as in replacement of defective bottom cover plate( Set of 2) for geyser ofany type, make and size with screws of suitable size as per site requirement made out of 20 gauge MS sheet, complete all as specified and directed by Engineer-in-Charge. |
| 26 | Material and labour for writing (MES AGE (I) R&D Manali)with paint or in sticker, complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply and fix in replacementRubber Gasket as per site requirement for 25/35/50 ltr geyser, complete all as specified and directed by Engineer-in-Charge. |
| 28 | Taking down copper/aluminium point wiring(light,fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting holder etc. removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conitions separately) and making good distrubed surfaces of walls, floors etc., complete all as specified and directed by Engineer-in-Charge. |
| 29 | M&L for Point wiring for One light point controlled by one, one way switch with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm widthwith MS sheet metal sunken switch/Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface, complete all as specified and directed by Engineer-in-Charge. Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate. |
| 30 | M&L for Point wiring for One 3 pin 5 amp socket out point on the same board with other switches with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm widthwith MS sheet metal sunken switch/Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface, complete all as specified and directed by Engineer-in-Charge. Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate. |
| 31 | M&L for Point wiring for One3 pin 5 amps socket out let point on independent board with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm widthwith MS sheet metal sunken switch/Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface, complete all as specified and directed by Engineer-in-Charge. Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate. |
| 32 | M&L for Point wiring for one socket outlet 15 amp on independent boardwith2.5Sq.mmcopper conductor cableand with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire , to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm widthwith MS sheet metal sunken switch/Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface, complete all as specified and directed by Engineer-in-Charge.Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate. |
| 33 | S &F Switch piano flushtype single pole one way 5 amps, complete all as specified and directed by Engineer-in-Charge. |
| 34 | S&F bell push switch fiush type 5 amp , complete all as specified and directed by Engineer-in-Charge. |
| 35 | S &F Socket out let 2 in one, 5/3 pin 5Amp, complete all as specified and directed by Engineer-in-Charge. |
| 36 | S &F Switch socket combination 5 Amps 5 pin flush type, complete all as specified and directed by Engineer-in-Charge. |
| 37 | S &F Switch socket combination 5 in 1, 5 pin5/15 Amps flush type universal, complete all as specified and directed by Engineer-in-Charge. |
| 38 | S &F Ceilingrose, surface bakelite 65x50 mm three terminal, complete all as specified and directed by Engineer-in-Charge. |
| 39 | S&F BELL ding dong AC 230 volt single pole , complete all as specified and directed by Engineer-in-Charge. |
| 40 | S &F Lamp holder, PVC/Polycarbonate type insulated body with back plate for angle holder suitable for fixing of LED Bulbs of any wattage 230 Volts, complete all as specified and directed by Engineer-in-Charge. |
| 41 | M & L MODULAR(GANG BOX) Switch socket outlet 3 pin 5 amp\" flush type, complete all as specified and directed by Engineer-in-Charge. |
| 42 | M & L MODULAR(GANG BOX) Switch socket outlet 3 pin, 15 amp, flush type, complete all as specified and directed by Engineer-in-Charge. |
| 43 | S &F for LED bulb/lamp of7/9 Watts Cool Daylight make, complete all as specified and directed by Engineer-in-Charge. |
| 44 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed by Engineer-in-Charge. |
| 45 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and directed by Engineer-in-Charge. |
| 46 | S & F Ultra bright glass 20W LED tubelight with very high efficacy suited for installation in existing, complete all as specified and directed by Engineer-in-Charge. |
| 47 | Taking down old and UNSV DBs SPN/TPN complete with MCB TPN/SPN/SP, complete all as specified and directed by Engineer-in-Charge. |
| 48 | S&F in repair MCB DB 8 Way Sheet metal enclosure factory made for DBs single pole and neutral double door 240 voltswith 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces, complete all as specified and directed by Engineer-in-Charge. |
| 49 | S&F MCB,DP 415 Volts , 40-63 Amps, complete all as specified and directed by Engineer-in-Charge. |
| 50 | S&F MCB SPN, 240 Volts , 32-40 Amps, complete all as specified and directed by Engineer-in-Charge. |
| 51 | S&F MCB, TPN, 415 Volts , 63 Amps, complete all as specified and directed by Engineer-in-Charge. |
| 52 | S&F MCB singal pole 240 Volts , 6 to 32 Amps , complete all as specified and directed by Engineer-in-Charge. |
| 53 | Material and labour for sub main wiring complete with 2 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLSH type, PVC insulated, unsheathed, flexible, multi strandedduly colour coded cable drawn through and including PVC conduit of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size including concealedinwalls/roofs/ ceilings/floors etc and including 01 run of 6 sqmm single core, copper conductor cable 1100 volts grade, FRLSH type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade including removing old unserviceable item, complete all as specified and directed by Engineer-in-Charge. Note : -Two run of 6.0 sqmm cable and one run of 6.0 sqmm cable and one run of PVC conduit concealedinwalls/roofs/ ceilings/floors etc will be measured as one unit. |
| 54 | Material and labour for sub main wiring complete with 2 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLSH type, PVC insulated, unsheathed, flexible, multi strandedduly colour coded cable drawn through and including PVC conduit of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size including concealedinwalls/roofs/ ceilings/floors etc and including 01 run of 4 sqmm single core, copper conductor cable 1100 volts grade, FRLSH type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade including removing old unserviceable item complete all as specified and directed.Note : -Two run of 4.0 sqmm cable and one run of 4.0 sqmm cable and one run of PVC conduit concealedinwalls/roofs/ ceilings/floors etc will be measured as one unit. |