| Sl. No. | Item Description |
| 1 | Excavation in trenches n.exc 1.50m wide and n.exc 1.50m depth for foundation etc or for shafts, walls, cess-pits, manholes, pier holes, pipe line etc n.exc. 10 sqm on plan and n.exc. 1.50m in depth, getting out in any type of soil complete all as specified and as directed. |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thickin soft/loose soil complete all as specified and as directed. |
| 3 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed. |
| 4 | S&F in repairs 110 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trenches complete all as specified and directed. |
| 5 | Demolition by breaking up drain pipes (salt glazed stoneware or AC/RCC) 150mm dia jointed in cement mortar and taking out of trenches and removing the debris including concrete bed and haunching from the trenches complete all as specified and directed. |
| 6 | Demolition by breaking up drain pipes (salt glazed stoneware or AC/RCC) 200mm dia jointed in cement mortar and taking out of trenches and removing the debris including concrete bed and haunching from the trenches complete all as specified and directed. |
| 7 | M&L for 150mm bore/inner dia Double wall corrugated (DWC) pipe (SN-4) with intergral socket and all necessary fttings, laid in trenches jointed confirming to IS 16098 (Part 2) complete all as specified and as directed. |
| 8 | M&L for 200mm bore/inner dia Double wall corrugated (DWC) pipe (SN-4) with intergral socket and all necessary fttings, laid in trenches jointed confirming to IS 16098 (Part 2) complete all as specified and as directed. |
| 9 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work, PCC benching/coping, precast concrete articles etc complete all as specified and as directed. |
| 10 | M&L for brickwork with fly ash bricks,straight or curved on plan exc 6m mean radious,built in cement mortar 1:4complete all as specified and as directed. |
| 11 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 12 | M&L for cement concrete type C2 1:3:6 (using 40 mm graded stone aggregate)in foundations, filling and mass concrete, sub base complete all as specified and as directed. |
| 13 | M&L for PCC 1:2:4 type B-0 (using 12.50 mm graded stone aggregate) as in benching, coping etc including necessary form work complete all as specified and as directed. |
| 14 | M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surface fininished even and smooth without using extra cement with integral water proofing compound in the proportion as per manufacturers instructions complete all as specified and as directed. |
| 15 | Demolition of reinforced cement concrete of any description and in any position complete all as specified and as directed. |
| 16 | M&L for pre-cast RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in manhole cover slab, drain cover and fixed in position including necessary form work and set in CM 1:6 complete all as specified and as directed. |
| 17 | S&F mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, footing, roof beam, plinth beam, slab,chajjas and similar work hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 18 | Supply and laying readymix bituminous Patchmate n exc 150mm depth as in road cutting and making good to surfaces complete all as specified and directed. |
| 19 | M&L forPVC (SWR)gully trap 125/110 mm, setting and jointing with solvent cementgully trap 75mm dia meter of out let, plain withCP grating including jointing with solvent cementcomplete all as specified and directed. |
| 20 | Cleaning, removing sludge and dewatering gully trap upto 1st Manhole using a mechanical pump and disposing of the waste at a distance exceeding 1 KM but not exceeding 1.50 KM before connecting to sewage line and making functional complete all as specified and directed. |
| 21 | M&L for 60 mm thick machine pressed precast conctete interlocking paver block in glossy finishwith grey cement and pigment , any shape and size confirming to IS 15658-2006, M-35 Grade laying over and including 50 mm thick stone dust/sand cushion complete inlcuding dismantling of old paver block complete all as specified and directed. |
| 22 | M&L for 75mm thick cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in floor finished even and fair complete all as specified and directed. |
| 23 | M&L for construction RCC Septic tank (Conventional) designed to carry sewage and sullage water,with effective depth of 1.50 meter and overall depth of 3 meter for 100 users including excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete as specified and shown in drawings TD Drg No CEJZ/TD/987 Sheet 1/2 & 2/2complete. |
| 24 | Demolition of cement concreten.exc 15 cm depth ofany description and in any position not otherwise specifically provided (below or above ground level) including removal of concrete debrisfrom site up to 500 metre complete all as specified and directed. |
| 25 | M&L for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete and sub base of floor complete all as specified and directed. |
| 26 | Formwork to faces of walls,retaining walls,abutments parapets and staircase railing and similer work including attached pillasters,buttresses etcvertical or to batter for fair and smooth finishedcomplete all as specified and directed |
| 27 | M&Lfor RCC M-25 (design mix) as in walls, reatining walls, drainage, basement walls, ballest walls and the like any thicknes; above top of footing; including attached pilasters and buttresses all as specified and directed. |
| 28 | Surface dressing n exc 15 cm deep in soft/loose soil complete all as specified and directed. |
| 29 | Excavation over areas in any type of soil nexc 1.50m deep and getting out complete all as specified and as directed. |
| 30 | M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed includingwatering as required complete all as specified and directed. |
| 31 | M&L for hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 32 | M&L for RCC M-25 (Design mix) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and the like complete all as specified and directed. |
| 33 | M&L for RCC M-25 (Design mix)as in slabs supported on walls, ,chajjas, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 34 | M&L for RCC M-25 (Design mix)as in roof beam, plinth beam,roof beam, lintel beams and columns complete all as specified and directed. |
| 35 | M&L for RCC M-25 (Design mix)as inColumns, footing, pillars, piers, posts and struts complete all as specified and directed. |
| 36 | S&F Mild steel TMT bars 5 mm dia and over up to and incl 10 mmdia as in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, footing, roof beam, plinth beam, slab,chajjas and similar work hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 37 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc. complete all as specified and directed. |
| 38 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc complete all as specified and directed. |
| 39 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 40 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed. |
| 41 | M&L for granite (of any type) tiles 20mm thickmechine cut,bedded and jointed with gray cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone incl grinding and polishing over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed. |
| 42 | M&L for 15 mm thick rendering in CM 1:6 onbrick work or concrete surfaces, surfacesfinished even and smooth without using extra cement complete all as specified and directed. |
| 43 | M&L for glazed ceramic coloured tiles450mm x 300 mmsize6 to 7mm thick in dados or skirting over and including rendering 10mm thick in CM (1:4), jointed in neat grey cement slurry and pointed in white or colour cement to match the tiles complete all as specified and directed. |
| 44 | M&L for Non skid ceramic tiles coloured, 7 to 8 mm thick (Square / rectangular ) area of each tile exceeding 0.11 Sqm but n. exc 0.18 Sqm,over and including 20mm thick screed bed in CM (1:6) in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles complete all as specified and directed. |
| 45 | S&F wash hand basins, vitreous china,of size 550x400mm (flat back, or angle back type)including cutting for and pinning in ends of brackets or erecting stand exclusive of fixing of supply and waste pipe etc complete all as specified and directed. |
| 46 | S&F padestal pattern Vitreous china wash down water closet pan white including trap, PVC white seat cover white, connection to drain (or out going pipe ) and to flushing pipe antisyphone pipe etc complete all as specified and directed. |
| 47 | S&F PVC valveless, syphonic action type flushing cistern,low/high level white with inlet ball valve float and handle including brackets complete fixed in repair capacity of flush 10 ltrs complete all as specified and directed. |
| 48 | S&F PVC waste pipes of 40/32mm bore suitable for wash hand basins/sinks/urinals outlet complete all as specified and directed. |
| 49 | S&F 75 mm bore PVCfloor traps plain with grating and 300 mm long out let including jointing and etc complete all as specified and directed. |
| 50 | S&F PVC pipe of 40 mm dia,in any length including reuired bends and in any position such as walls, ceiling or laid in floor or trenches etc. complete all as specified and directed. |
| 51 | S&F PVC bends 75mm bore, any radius complete all as specified and directed. |
| 52 | S&FPVC (SWR) pipes ofdia 110 mm single socketed in any length with rubber ring joints laid in trenches or in floors of dia 110 mm complete all as specified and directed. |
| 53 | S&FPVC (SWR) pipesof dia 75 mm single socketed in any length with rubber ring joints fixed to wallsof dia 75 mm complete all as specified and directed. |
| 54 | S&F Bib taps (push type) cast copper alloychromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe of 15mm bore complete all as specified and directed. |
| 55 | S&F fancy type chromium plated two way bib cock of 15mm bore,screwed for iron pipe or brass ferrule etc complete all as specified and as directed. |
| 56 | S&F pillar taps (swan neck), fancy typecast copper alloy with capstan heads, chromium plated, screwed down, high pressure with or without lettered “hot” or “cold” with long screwed shanks and fly nut screwed for iron pipe of 15mm bore,complete all as specified & directed. |
| 57 | S&F stop/angle cock cast copper alloy high pressure,angle valve type, chromium plated suitable for 15mm bore steel pipecomplete all as specified and directed. |
| 58 | S&F health faucet 15 mm diawith flexible pipe of 1.25m length including abs wall hook forEWC complete all as specified and as directed. |
| 59 | S&F PVC connections of 450mm long suitable for 15mm dia iron pipe including PTMT nuts complete all as specified and as directed. |
| 60 | S&F 15mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including testing complete all as specified and as directed. |
| 61 | All as per serial item No. 60.00 above but 20mm bore. |
| 62 | S&FGun -metal,globe or gate valves 15mm ,with iron wheel head ,screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 63 | S&F 20mm boreball valve highpressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed. |
| 64 | S&F rotational moulded polythylene 1000 Ltr capacity water storage tank (double layer)(cylindrical/vertical with closte top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed. |
| 65 | S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm vide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed. |
| 66 | S&F bevelled edge mirror of 5 to 6 mm thick selected quality glass of size 600 x 450 mm mounted on 6mm thickAC building board or commercial plywood andfixed to wooden plug with chromium Plated brass screw and cup washers complete all as specified and as directed. |
| 67 | S&Fbrass chromium plated towel rail, 60 cm long, 20mm bore complete all as specified and as directed. |
| 68 | S&F SS Toilet paper holder complete all as specified and as directed. |
| 69 | S&FPVC door frames of sizes 50 x 47 mm made out of 5 mm prelam PVC sheet reinforced with MS Square tube in opening of suitable size complete all as specified and directed. |
| 70 | S&Ffactory made (Prelam on both sides) solid panel PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall covered with heat moulded prelam PVC \"C\" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for styles and prelamPVC sheets for top rail, lock rail and bottom rail in either side and as gap insert for top rail and bottom rail pannelling of prelam PVC sheet to be filled in the MS welded/sealed to the styles and rails with suitable PVC sheet beading and jointed together wiht solvent and fixing in the frame at site as per specification and drawing complete all as specified and directed. |
| 71 | S&F 100mm long butt hinges medium weight cold rolled mild steel complete all as specified and as directed. |
| 72 | S&F 150 mm long Aluminium anodizes barrel tower bolts of extruded section complete all as specified and as directed. |
| 73 | S&F Mild steel pressed handles 150 mm, oval type, stove enamelled black complete all as specified and as directed. |
| 74 | M&L for 75 mm thick PCC 1:3:6 type C-2 (using 20mm graded stone aggregate) as in plinth protection Finishing surfaces of concrete topping even and fair (without using extra cement) including making joint at every 3 mtr interval and at corner and filled with mixture of bitumen and sand and finished even and fair and laid in alternate bays complete all as specified and directed. |
| 75 | M&L for preparation of newly plastered surfaces of wall and applying two coat of Ist quality exterior weatherproof water base emulsion paint over a coat of primer of same make on wall as specified and directed pillasters, cornices etc scrapping down , brooming down or steel wire brushing, and washing with water after completion of precoat treatment applying two coats of Anti fungal Weather coat paint (Exterior emulsion) white or tinted over a coat of primer (X2) complete all as specified and directed. Note :-(a) Each stage i.e preparation of surfaces, application of primer, application of first coat.application of second coat will be got passed from Engr-in-Charge/GE.(b) Written Warranty for four years or as per manufacturer\"s instructions, whichever is more is required to be furnished by contractor for this item. |
| 76 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistance primer complete all as specified and directed. |
| 77 | M&L for preparation of new plastered surfaces of walls and applying three coats of white wash on ceiling surfaces complete allas specified and directed. |
| 78 | S&F anodised aluminium window, ventilator shutters with frame, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. and fixed in position complete allas specified and directed. |
| 79 | M&L for 1mm thick wall care putty over prepared surface to achive the surface even and smooth for painting complete allas specified and directed. |
| 80 | M&L for sand filling under floors or interlocking tile or in foundation including watering and consolidation complete all as specified and directed. |
| 81 | M&L for 60mm thick machine pressed precast concrete interlocking paver blockfixing with grey cement and pigmentsofcolour and shape as approved by GE and confirming to IS 15658-2006 of M-35 Grade set , laid over 50 mm (average) thick dust sand cushioning,filling of joints with sand & compaction using surface vibrator after filling of joints lain in any pattern as decided by Engineer-In-Charge including packing of sides by cement concrete finishing surfce even and smooth complete all as specified and as directed. Note : Sand cushioning shallbe measured and paid separately . |
| 82 | S&F factory made kerb stone 1:2:4 (using 20mm graded stone aggregate) cement concrete in position to the required line, level and curvature, jointed and set in cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 83 | S&Freinforced concrete pipes 150 mm bore, class NP2 , laid and jointed complete with collars, andconcrete bed to drain pipesincluding packing under and haunching against the sides of pipes after they are laid and tasted; in cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) including demolition and breaking up salt glazed ware stoneware pipes, complete all as specified and directed. |
| 84 | M&L for providing complete water proofing treatment on inaccessible roof surfaces (horizontal and vertical surfaces) through authroised applicator of manufacturers comprising:-(a) Cleaning of new concerete surfaces properly and drying the surfaces and applying 10mm thick renderingover a coat of cement slurry mixed with WPC (b) Applying a tack coat of Industrial bitumen grade of 85/25 at the rate of 1.2 Kg per Sqm including cleaning surfaces (1st coat for bonding material below membrane and 2nd coat on top of membrane. Each coat will be paid seperately.)(c) Applying a coat of Oxidised bitumen based solvent primer @ 0.30 Kg/Sqr mtr (d) 3mm thick APP (Ataclic Polypropylene) modified water proofing membrane with polyestar core, overlaps, sealed and bonded to the surfaces with torch application (e) Applying two coats of bituminous aluminium paint @ 200gm per sqr mtr (min) in two coats as per manufactueres instructions complete all as specified.Note: Cost of water proofing compound shall deemed to be included in unit rates quoted by contractors. |
| 85 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in cills, steps, seismic and other similar bands, plinth courses, string courses, parapets and railing upto 60 cm in height, coping, kneelers, apex stones bed plates, etc and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary use and waste of form work complete all as specified and directed. |
| 86 | S&Fmild steel work (Tubular, square/rectangular hollow section) as in purline, rafter and wind ties, cleat roof trusses etcincluding securing bed plate, plat iron fillets for securing wire mesh etc including all necessary drilling bolting or riverting, etc, and similar work conforming to IS 1161-1979 dge St-240 complete all as specified and directed. |
| 87 | M&L for preparation of new steel surfaces of any description ,over 10 cm width or girth and applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed. |
| 88 | S&F Pre-painted galvalum aluminium zinc coating steel based corrugated steel sheet 0.50mm thick (total coated thickness) of any colour having tensile strength of 550 Mpa minimum, yeild strength, it shall becoated with hot dip alloy of 55% aluminimum, 43.5% zinc,1.5% Silicon and finished with resin coat on both surface @ 150 gm/ sqm of coating as specified and shall be fixed with hot dip galvanised, self drilling and self tapping screws neoprened and EDPM washers as in roof covering complete all as specified and directed. |
| 89 | Supply,laying and testing and commisioning LT underground cable 1100 volts grade, XLPE insulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ducts, on poles etc of size 4 core x 16 Sqmm complete all as specified and directed. |
| 90 | Supply, laying and jointing Gl pipe \"light grade\" 40 mm bore in trenches/under floors or roads/along poles/ on wall incl clamps for protection of cables incl fittings complete all as specified and directed. |
| 91 | M&L for clean and dry sand (un-washed) in trenches incl spreading and levelling for cushioning of UG cable complete all specified and directed. |
| 92 | Supplying and laying reinforced precast concrete cable cover, class LV, type 1 flat, size 250mm x 150mm x 40mm complete all as specified and as directed. |
| 93 | M&L for point wiring with FR LSH PVC insulated PVC unsheathed electric cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area drawn in & Including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good and matching disturbed surface of wall with existing surface of wall (cutting except on ceiling for fan point only, on ceiling instead of PVC conduit surface casing caping will be used) & 1.5 sqmm green FR LS H PVC insulated unsheathed copper conductor as earth wire connected to earth dolly by providing lugs including galvanised boxes and bakelite sheet for mounting switches, sockets, fan regulators etc for the following:- Make of PVC conduit/Casing Caping Plaza/Finolex/Polycab/Kalinga/Jindal/Asian.(a) One light point controlled by one switch |
| 94 | (b) One Exhaust fan point controlled by one switch |
| 95 | (c)One 5 Amp socket outlet point control by one switch on same board with other switch |
| 96 | S&F switch piano flush button single pole one way 6 Amp 240 volt complete all as specified and directed. |
| 97 | S&F socket outlet flush type 5 pin, 6 amps, 230 volts complete all as specified and directed. |
| 98 | S&F ceiling rose surface bakelite three terminal complete all as specified and directed. |
| 99 | S&F integrated LED tube light fitting 1x18/20 Watt, 6000K complete fitting with all accessories duly connection with three core flexible copper cable duly fixed on two nos Each of PVC square boxes complete all as specified and directed. Make:- Havells Cat No. LHEXBLP7PN1W018/ Bajaj cat Pt No. BCLSB 18WH Or Make/Brand as specified in Particular Specification as approved by GE. |
| 100 | S&F integrated LED tube light fitting 1x9/10 Watt, 6000K complete fitting with all accessories duly connection with three core flexible copper cable duly fixed on two nos of Each PVC square box complete all as specified and directed.Make: Havells Cat No. LHEXBLP7IN1W009 Bajaj Cat Pt No. BCLSB 10 WH Or Make/Brand as specified in Particular Specification as approved by GE. |
| 101 | S&FLED street light fittings 1x35 Watt, 5700K complete fitting having pressure dia cast aluminium housing with heat resistant toughened glass & IP 65/66protection Each fixed on and including sufficient length and appropriate size Gl bracket with all accessories duly connection with three core flexible copper cable complete all as specified and directed.Make:- Havells Cat No.LHEXAYP7PN6K030 Crompton Cat No. LSTO-25-CDL, Bajaj Cat No. BCLST 25W LED IV2 Or Make/Brand as specified in Particular Specification as approved by GE. |
| 102 | S&Fdouble door SPN DBs 8 way of powder coated DB\"s suitable for MCB\"s fitted with bus bar, Neutral link, Earth bar and Din ral complete all as specified and directed. |
| 103 | S&FMCB SPN 6 to 32 amps 10 KA, \"B\" series including connection with suitable size aluminium/copper lugs complete all as specified and directed. |
| 104 | S&F MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, \"B\" series including connection with suitable size aluminium/copper lugscomplete all as specified and directed. |
| 105 | S&F exhaust fan 250mm sweep, AC single phase 230 Volts, non metallic type, complete with louver including electric connection with suitable size copper conductor Each cable, clamps, nuts, bolts etc including making hole of appropriate size in the existing brick wall and making good the disturbed wall and matching with the existing surface of wall complete all as specified and directed by Engr-in-Charge. Make: Havells Model: Ventil Air-DX white or equivalent in /Bajaj/Crompton Or Make/Brand as specified in Particular Specification as approved by GE. |
| 106 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cmx 6.3 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground Each level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.5 of MES SSR parts-I and including excavation & earth work in any type of soil, disposal of soil, providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type C-1 with 40 mm thick RCC 1:2:4 type B-1 cover reinforced with 8mm dia MS TMT bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia Gl light grade and 15mm dia light grade pipe for earth lead protection and testing on completion including testing after completion complete all as specified and directed |
| 107 | S&F UPS single phase 30 minute backup AC input 160 to 260 V and out put 230 ± 1% of capacity 6 KVA, INPUT :- 110-280 VAC @50% Load, ; 176-280 VAC @100% Load, Single phase with Ground, Frequency Range- 56 Hz- 64 Hz, Power Factor- 0.98 @ Nominal Voltage (100% Load), Input Current Harmonic distrortion THD (i)- 8%, OUTPUT :-Nominal Voltage- 220/230/240 VAC, AC Volatge Regulation- ±1% (Battery Mode), Frequency Range- Synchronized Mode: 46 Hz- 54 Hz or 56 Hz- 64 Hz, Batter Mode: 50 Hz±0.1Hz or 60 Hz±0.1Hz, Current Crest Ratio- 3:1 (Max), Harmonic Distortion- ≤3% THD (Linear Load), Transformer Time (AC to DC)- Zero, Transformer Time (Inverter to Bypass)- 4ms (Typical), Wave Form (Battery Mode)- Pure Sine Wave on AC input mode and 54 VDC on Battery Mode, EFFICIENCY :- On full charged battery- Line Mode: 95%/ ECO mode: 99.5%/ Battery Mode: 92.0%, INDICATORS :- LCD Panel- Load level, Battery level, AC mode, Battery Mode, Bypass Mode, and fault Indiactor via LCD, PHYSICAL :- Dimensions Product (DxWxH)- 465x190x318 (in mm), Net Weight product (Kgs.)- 15.5 kg, ENVIRONMENT :- Operation Humidity/ Temp.- 0 to 95% Relative Humidity (Non-Condersing)/ 0-50°C, MANAGMENT :- Communication Interface- RS232 and USB, SNMP Card/ MODBUS card (Optional) complete all as specified and directed.Make/ Model- Microtek/6 KVA192VDC Max Life Online UPS 6KVA / Or Make/Brand as specified in Particular Specification as approved by GE. |
| 108 | S&F battery bank for UPS with suitable stand including electrical connection complete all as specified and directed. Make :Exide (Or Make/Brand as specified in Particular Specification as approved by GE) SMF Battery for 30 Minutes Backup Battery 12V26 Ah :- 16 Nos complete all as specified and directed. |
| 109 | M&L for sub main wiring with two runs of single core FR LS PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including non metallic rigid PVC conduit of not less than 25 mm dia casing caping on wall and making good the disturbed surface, including FR LS PVC insulated unsheathed 4 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly from main distribution board complete all as specified and directed by Engr-in-Charge. Make of PVC conduit/Casing Caping:- Plaza/Finolex/Polycab/Kalinga/Jindal/Asian Make Of wire - Make - Plaza,Finolex,Anchor, Havells, Nicco, RPG, KEI, Polycab, Gloster, RR KabelNote:- Two run of 4 Sqmm cable, one runs of 4 Sqmm cable and one run of PVC casing caping will be measured as one unit |
| 110 | M&L for sub main wiring with two runs of single core FR LS PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn in and including non metallic rigid PVC conduit of not less than 25 mm dia casing caping on wall by cutting chases of wall and making good the disturbed surface, includingPVC insulated unsheathed FR LS 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly from main distribution board complete all as specified and directed by Engr-in-Charge. Make of PVC conduit/Casing Caping:- Plaza/Finolex/Polycab/Kalinga/Jindal/Asian Make Of wire - Make - Plaza,Finolex,Anchor, Havells, Nicco, RPG, KEI, Polycab, Gloster, RR KabelNote:- Two run of 6 Sqmm cable, one runs of 6 Sqmm cable and one run of PVC casing caping will be measured as one unit |
| 111 | S&F double door SPN DBs four wayof powder coated DB\"s suitable for MCB\"s fitted with bus bar,Neutral link,Earth bar and Din ral complete all as specified and directed. |
| 112 | S&F MCB SP 6 to 32 amps 16 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed. |
| 113 | S&F MCB SPN 63 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed. |
| 114 | Dismantling non-clog submersible pump of any descritpion/capacity and shifting/refixing in position complete all as specified and directed by Engr-in-Charge. |
| 115 | Taking down GI tubing pipe exc 75 mm but nexc 150mm bore and shifting/refixing in position complete as directed by Engr-in-Charge |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail