| Sl. No. | Item Description |
| 1 | Dismantling of brick tiles or terracing tiles single layer laid on roof jointed & pointed in cement mortar, complete all as specified and directed. |
| 2 | Demolition mud in roofs, any thickness, including plastering and leeping etc complete all as specified and directed |
| 3 | Demolition of un-reinforced cement concrete in any position complete all as specified and directed. |
| 4 | M&L for Cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection, 75mm thick, surfaces finished even and fair without using extra cement as in plinth protection including provision of construction joints complete all as specified and directed. |
| 5 | M & L PCC (1:2:4) type B-0 using 12.5mm graded stone agg as in haunching, kerb in roof, sunken or similar work complete all as specified & directed. |
| 6 | M&L for Cement concrete (1:5:10) type E-2 using 40mm graded stone aggregate as in filling in sunkan slab or asin sub base, mass concrete, complete all as specified and directed. |
| 7 | M&L for 50 mm thick cement concrete (1:2:4) type B-1 using (20 mm gradedcrushed stone aggregate) as in roof, sub base of flooring,surface finished rough to receive floor topping, complete all as specified and directed. |
| 8 | M&L for 15 mm thick rendering over concrete surface of sunken floorin CM 1:3 on wall as well as sunken floor finished even and smooth without using extra cement using WPC complete all as specified and directed. (WPC measured and paid separetely) |
| 9 | M&L for rendering/screeding 10 mm thick cement plaster on roof surfaces in cement mortar (1:4) finished even and fair and using with water proofing compound complete all as specified and directed |
| 10 | M&L for water proofing treatment to sunken/roof surface includingparapet wall comprising with the following course of treatment/ specifications form bottom to top:-(a) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per sqm over a coat of bitumen primer @ 0.30 ltr per sqm including preparation of roof surfaces complete all as specified and as directed. (b) One layer of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing.Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer\"s instructions.(ii) A minimum overlap shall be 75mm length wise and 100 mm width wise ofpolymeric membranes respectively and sealed all overlaps and joints as manufacturer\"s instructions. |
| 11 | M&L for two coat of aluminium paint over APP membrane, complete all as specified and directed. |
| 12 | Supply only integral water proofing compound, complete all as specified and directed. |
| 13 | Dismentling of floor tiling withcement mortar bedding (but not backing) removing seviceable tiles to store and rubbish off the premises complete all as specified and directed |
| 14 | M & L Glazed Ceramic coloured tiles in vertical surface 350 x 250 x 7mm/450 x 300 x 7 mm thick primium quality over and incl 10 mm thick rendering in CM 1:4 on vertical surfaces, set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match colour of tiles complete all as specified & directed. |
| 15 | M & L Non - skid Ceramic tiles coloured 7 to 8 mm thick (square/ rectangular),primium quality area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and incl screed bedding 15mm thick in cm(1:6), complete all as specified and directed. |
| 16 | Taking down cement plaster or terrazzo from brick walls of any description, racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 17 | M&L for Rendering/plastering, 15 mm thick in cement mortar (1:4) on brick or concrete surfaces, surfaces finished even and smooth without using extra cement, complete all as specified and directed. |
| 18 | M&L for 15mm thick rendering in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed. |
| 19 | M&L for 5mm thick rendering in cement mortar (1:3) on concrete surfaces, finished even and smooth without using extra cement as in ceiling, complete all as specified and directed. |
| 20 | M&L for Preparation of new plastered wall surfaces and applying two coats of cement base paint over a coat of chalk white primer, complete all as specified and directed. |
| 21 | Preparation of new surfaces of wall and applying two coats of white lime wash (white washing) on walls including corneces, pillars complete all as specified and directed. |
| 22 | M&L for Preparation of newly plastered surfaces of ceiling & applying three coats of white wash complete all as specified and directed. |
| 23 | Preparation of old decorated surfaces of wall and applying one coat of white lime wash (white washing) on walls including corneces, pillars complete all as specified and directed. |
| 24 | M&L for Preparation of old decorated surface of wall and applying one coat of cement based paint including corneces, pillars etc complete all as specified and directed. |
| 25 | M&L for Preparation of old decorated surfaces on ceiling and applying one coat of white lime wash including cornice and pillars etc complete all as specified and directed. |
| 26 | Taking downchowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 Square metre each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified and directed. |
| 27 | All as per item No. 26 above herein before but size exceeding 1.5 Square metre and not exceeding 4 Square metre each, complete all as specified and directed. |
| 28 | S&F Solid PVC door frame of size 50 mm x 47 mm made of 5 mm plain colour PVC sheet reinforced with mild steel square tube complete all as specified in clause 8B.3.1 and shown on page 150 of MES Schedule Part-II (2010), complete all as specified and directed. |
| 29 | S&F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004), complete all as specified and directed. |
| 30 | S&F for PTMT tower bolts, 200 mm long and fixed with steel screws, complete all as specified and directed. |
| 31 | S&F for PTMT handle 125mm long fixed with steel screws, complete all as specified and directed. |
| 32 | S&F for PTMT butt hinge, 100mm long,fixed with steel screws with brass/bronze hinge pin, complete all as specified and directed. |
| 33 | S&F factory made double rebate box type side hung steel window with glazed and mesh shutters with pintal hinges & 2 Nos 150 mm mild steel tower bolts to each shutter, steel handle with & withoutglazing bars, one side two shutters with glazing bars & other side glazed shutter with glazing bars including 10mm mild steel guard bars dovetailed or welded and with framed with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEJZ/TD-06/07 & CEJZ/TD-07/07. NoteWiremesh & glass will be measured separtely. |
| 34 | S&F Factory made box type steel ventilator with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEJZ/TD-1019/08 sheet 1/3 to 3/3, complete all as specified and directed. |
| 35 | S&F Mild steel framed work of as in grills/guard bars shouldered with steel window/ ventilator frames, complete all as specified and directed. |
| 36 | M&L for Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over primed steel surfaces, complete all as specified and directed. |
| 37 | M&L for one coats of synthetic enamel paint, including preparation of old painted steel opaintr steel bases surface of any description over 10 cm width or girth, complete all as specified and directed. |
| 38 | M&L for one coats of synthetic enamel paint including preparation of old painted wood or wood bases surface of any description over 10 cm.width or girth, complete all as specified and directed. |
| 39 | S&F 3mm thick, plainsheet glass ordinary quality and glazing,with oil putty or with wooden beads(supplied alongwith shutters), in squares n.exc 0.50 Sqm, complete all as specified and directed. |
| 40 | S&F stainless steel wire cloth0.36 mm nominal dia of wire and average width of aperture not more than 1.18 mm and fixed with stainless steel wire staples complete all as specified and directed |
| 41 | Taking up or down existing steel water tubing, 15mm bore alongwith connections fixed/laid in any situation, complete all as specified and directed. |
| 42 | Taking up or down existing steel water tubing, 20mm bore alongwith connections fixed/laid in any situation, complete all as specified and directed. |
| 43 | S&F galvanised steel water tubes 15 mm bore medium grade, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and as directed by Engr-in-Charge. |
| 44 | S&F galvanised steel water tubes 20 mm bore medium grade, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and as directed by Engr-in-Charge. |
| 45 | Fixing only, after cleaning old steel water tubing, 15mm bore and connections in new or old position using new fittings, complete all as specified and directed. |
| 46 | Fixing only, after cleaning old steel water tubing, 20mm bore and connections in new or old position using new fittings, complete all as specified and directed. |
| 47 | M&L for GI steel water tubing, 40mm bore medium grade galvanized with all fittings and fixedto walls and celling or laid in floor, complete all as specified and directed. |
| 48 | S&F in repair Wash hand basin, flat back 550x400 mm vitreous china (white) including PTMT waste fittings, 32mm bore size, PVC, 32mm bore, angle iron/cast iron brackets of required size as directed & making good disturbed surfaces to match with the existing, complete all as specified and directed. |
| 49 | S&F in repair 15mm bore pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and directed. |
| 50 | S&F in repair 600x450 mm beveled edge looking mirror of selected quality glass and backing with 6mm thick AC building board and fixed to wall with PVC rawl plugs with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 51 | S&F Vitreous china white squatting pan orrissa pattern of size 580mm x 440 mm with integral foot rests including necessary lime concrete and 100 mm bore cast iron ‘P’ or \"S\" trap with 550 to 600 mm long neck for connecting WC to branch piece with cement joints, fixed as in repair, complete all as specified and directed. |
| 52 | S&F in repair Viterous China wash down water closet pan (pedestal pattern), white incl. Seat and cover & CP jet(excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed |
| 53 | S&F PVC low level flushing cistern (white) of 10 liters capacity with inlet ball float valve, PVC flush pipe and necessary fixing arrangements and connecting to water pipe and WC etc and fixed in repairs, complete all as specified and directed. |
| 54 | S&F in Repair to Viterous China bowl urinal flat back, size of 465 x 355 x 265 mm white (miniumum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe)including providing and fixing plugs, bedding urinal agianst wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing aroiund urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipee. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed |
| 55 | Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed. |
| 56 | S&F in repair stop cock/Angle cock 15 mm cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe etc, complete all as specified and directed. |
| 57 | S&F in repair Bib tap long body of CP brass, 15mm bore, fancy type long bodyscrewed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed. |
| 58 | S&F 15mm bore stop valves/angle cock of cast copper alloy, screwed down, high pressure with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup (concealed type) fixed in repairs, complete all as specified and directed. |
| 59 | S&F PVC connection 15mm size with PTMT nuts of length 450mm, complete all as specified and directed. |
| 60 | S&F PVC waste pipe, 32mm bore suitable to waste coupling pipe attach with rubber ring joints fixed to waste coupling of sinks/WHBs complete all as specified and directed. |
| 61 | S&F in repair Towel rail, 19mm dia brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs, complete all as specified and directed. |
| 62 | S&F 1000 litres capacity rotational moulded, triple layer polythene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in positionon roofs including fittings & dismantling existing water storage tank, including S&F 20mm bore PTMT ball valve high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed. |
| 63 | Taking down eaves gutters and rainwater pipes(any size or pattern), including all fittings, heads, shoes, bends, swan-necks etc complete all as specified and directed. |
| 64 | S&F 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls, complete all as specified and directed. (fitting measured separately). |
| 65 | S&F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solventincluding jointing to waste pipe in run lead as in repairs, complete all as specified and directed. |
| 66 | S&F 75 mm bore PVC (SWR) junction double, (double T), equal or unequal in repair, complete all as specified and directed. |
| 67 | S&F 75 mm PVC (SWR) junction single, (Single T) equal or unequal in repair, complete all as specified and directed. |
| 68 | S&F 75 mm bore PVC (SWR) bends any radius with access doorfixed to walls including distance pieces and stack clamps, complete all as specified and directed. |
| 69 | S&F PVC (SWR) vent cowl of 75 mm size, complete all as specified and directed. |
| 70 | S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls including distance pieces and stack clamps, complete all as specified and directed. |
| 71 | S&F 110 mm bore PVC (SWR) bends/shoe any radius with access door fixed to walls including distance pieces and stack clamps, complete all as specified and directed. |
| 72 | S&F PVC (SWR) vent cowl of 110 mm size, complete all as specified and directed. |
| 73 | S&F 110 mm bore PVC (SWR) junction double, (double T), equal or unequal in repair, complete all as specified and directed. |
| 74 | S&F 110 mm PVC (SWR) junction single, (Single T) equal or unequal in repair, complete all as specified and directed. |
| 75 | S&F 125mm dia CP brass shower rose with swivel joints, any colour including shower arm 15mm dia, 195mm long with bend of 45 degree with flange of CP brass as in repair, complete all as specified and directed. |
| 76 | Demolition of brick work built in cement mortar of any specification and in any position complete all as specified and directed. |
| 77 | M&L Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and directed |
| 78 | M&L brick work with sub class \"B\" bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and directed |
| 79 | All as per item 78 above here-in-before but using old bricks retrieved from dismantling underhere-in-before including cleaning and removal of mortar from old bricks etc including demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc complete all as specified and directed |
| 80 | S&F in repair Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed. |
| 81 | M&L for cleaning the blockage of bathroom/kitchen/Toilet by cleaning the nanhi traps / gully traps of all the mud / sludge and getting out washing throughly traps, CI waste pipe by opening the cleaning eyes and depositing the sludge in a pit of suitable size at a distance not exceeding 100m from the gully trap and covering the same with the soil obtained from excavation of pit including excavation and earth work complete all as specified and directed. |
| 82 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting outin soft/ loose soil all as specified and directed by Engr in charge. |
| 83 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed |
| 84 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil all as specified and directed. |
| 85 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in any type of soil all as specified and directed. |
| 86 | Removing surplus soil to a distance not exceeding 100 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as spd and directed. |
| 87 | M&L for hardcore broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick,wateredand rammed to a true surface all as specified and directed. |
| 88 | M&L for PCC 1:3:6 type C2 using 40mm graded aggregate in foundations, filling and mass concrete complete all as specified and directed |
| 89 | M&L for RCC nominal mix 1:2:4 type B1using 20mm grade aggregate in foundations, including rafts, footings,foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed |
| 90 | M&L for RCC nominal mix 1:2:4 type B1using 20mm grade aggregate in columns, pillars, piers, posts and struts complete all as specified and directed |
| 91 | M&L for RCC nominal mix 1:2:4 type B1 using 20mm grade aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed |
| 92 | M&L for RCC nominal mix 1:2:4 type B1 using 20mm grade aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed |
| 93 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces complete all as specified and directed |
| 94 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces complete all as specified and directed |
| 95 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces complete all as specified and directed |
| 96 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces complete all as specified and directed |
| 97 | M&L for formwork to edges of roof slabs n exc 20cm wide for rough finished surfaces complete all as specified and directed |
| 98 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 99 | M&L for mild steel TMT bars6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 100 | M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required as in reinforcement and binding with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed |
| 101 | M&L for Rendering/plastering, 10mm thick in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth (without using extra cement) includingPreparation of new plastered surfaces wall and applying two coats of white wash complete all as specified and directed. |
| 102 | M&L for 40mm thick cementconcrete type B-1, 1:2:4 using 20mm graded aggregate in sub base in floors complete all as specified and directed. |
| 103 | S&F light shade Vitrified ceramic tiles 9-10mm thick (Square/ rectangular) polished area of each tiles n.exc 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20 mm thick screed bed or bedding layer of cement mortar(1:6) for laying floor finishes complete all as specified and directed |
| 104 | M&L forlight shade Vitrified tile 10mm thick polished, area of tile n exc.0.36 sqm as in Skirting set and jointed in cement slurry over and including 15mm thick screed in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed |
| 105 | S&F Factory made box type steel ventilator with glazing bars dovetailed or welded,grills/guard bars shouldered with steel ventilator frames and with one shop coat of zinc chromate primer complete all as specified and directed. |
| 106 | Taking down Shutters of any description exc 1 sq. m and n exc 2 sq. m each complete all as specified and directed. |
| 107 | S&F for Pressed Steel Frames for doors1.25 mm thick MS sheet of profile (105X60)mm for doors and windows frames with one or more rebates including necessary fixing lugs, hinges, lock, strike plates, shockabsorber 20mm dia,60mm MS conduit for housing of a drop bolt etc. treating of internal surfaces of chowkhats with coal tar or black paintccomplete all as specified and directed |
| 108 | S&F for Pressed Steel Frames for doors1.25 mm thick MS sheet of profile (125X60)mm for doors and windows frames with one or more rebates including necessary fixing lugs, hinges, lock, strike plates, shockabsorber 20mm dia,60mm MS conduit for housing of a drop bolt etc. treating of internal surfaces of chowkhats with coal tar or black paintcomplete all as specified and directed |
| 109 | M&L for PCC (1:3:6) type C-1 using 20 mm gradedstone agg .as in filling steel frames etc including necessary form work complete all as specified and directed |
| 110 | Material and labour forPCC (1:2:4) type B1 with using 20 mm graded stone agg as inbed blockhold fast block complete all as specified and directed |
| 111 | S&F 35 mm thick, 2nd class hard wood, plain framed, panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered particles board medium density wood particle board with comercial face veneers, size of members as specified in clause 8.24 (a) of MES Schedule Part-I section-II complete all as specified and directed. |
| 112 | S&F 35 mm thick, 2nd class hard wood, glazed and skeleton shutters open rebated and prepared to receive glass,gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etc, size of members of shutters as specified in SSR part-I section 8, clause 8.24 (a) of MES Schedule Part-I Section-8, complete all as specified and directed |
| 113 | S&F 200 mm mild steel barrel tower bolt, stove enamelled black, with bright bolt complete all as specified and directed |
| 114 | S&F 150 mm mild steel pressed handles, oval type stove enamelled black complete all as specified and directed |
| 115 | S&F for 250 mm Mild Steel sliding door boltsplate type, stove enamelled black, with bright boltnot less than 12 mm dia with and including a minimum 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed |
| 116 | S&F300mm, Mild steel ordinary rat tail rod patttern springs includding roller and roller plate complete all as specified and directed |
| 117 | M&L for Preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed |
| 118 | S&Fstainless steel wire cloth0.56 mm nominal dia of wire and average width of aperture not more than 1.18 mm and fixed with stainless steel wire staples complete all as specified and directed |
| 119 | S&F butt hinges, medium weight, cold rolled mild steel, 100mm, complete all as specified and directed. |
| 120 | S&F 150mm long aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed. |
| 121 | S&F for 150mm aluminium handles, cast type, anodised complete all as specified and directed. |
| 122 | S&Ffor 15mm bore stop valves/ angle valve CP of cast copper alloy, screwed down, high pressure with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup, complete all as specified and directed. |
| 123 | S&F for CP Bib tap, 15mm bore, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed. |
| 124 | S & FCP WHB mixer (Cera cat No: F2002461 Basin Mixer ) 15mm bore. With out popup waste system with 450mm long braided hoses Complete all as specified and directed by Engineer in Charge. |
| 125 | S&F for Rotational moulded Polyethylene water storage tank of 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position including 20mm PVC float valve high pressure with polythene float valve complete allas specified and as directed |
| 126 | S&F 600mmX450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board of commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers with alround aluminium beading all as specified and directed by Engineer-in- charge |
| 127 | S&F Vitreous china wash down water closet pan (pedestal pattern)white/coloured cascade type 655X355X735mm (monolithic flush cistern type) CERA Cat No: S1013207s single picece wc with soft slim close seat cover ,Hinges fixing accessories set including flush cistern with S-Trap of size 220mm all as per manufacturing instructions and all asspecified and directed. (Make:Cera/Jaguor/Parryware ) |
| 128 | S&F Wash hand basin, flat back 550x400mm vitreous china (white) including PTMT waste fittings, 32mm bore size, waste pipe, PVC, 32mm bore, angle iron/cast iron brackets of required size as directed & making good disturbed surfaces to match with the existing complete all as specified and directed. |
| 129 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 130 | S&F CP tubular towel rail, 20mm dia, D type, 60cm long between flanges as fixed all as specified and directed. |
| 131 | S&F for 15mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed |
| 132 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches complete all as specified and directed. |
| 133 | M&L for 75mm thick cementconcrete type B-1, 1:2:4 using 20mm graded aggregate in plinth protections complete all as specified and directed. |
| 134 | S&F 18/19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work complete all as specified and directed |
| 135 | S&F for continuous (piano) hinges, mild steel bright finish or electro galvanised with flap (when open) 40 mm, fixed with steel screws complete all as specified and directed. |
| 136 | S&F for hasp and staple of aluminium anodized, safety type, 100mm long, fixed with screws complete all as specified and directed. |
| 137 | S & F in Hollow PVC wall lining consisting of 5mm thick single side prelam PVC sheet instead of plain colour sheet inclusive of solvent cement and fixing on PVC frame as per specified in MES schedule part-I & II complete all as specified and directed by Engineer in Charge . |
| 138 | S & F in Gypsum Board 8 mm thick in ceiling fixed with screw 60x60cm placed in ceiling (Angle 25mm X 25mm, Main tee 38mmX23mm, Sub tee 23mmX23mm) incl aluminium anodised/powder coated snap grid frame 605X605 mm for false ceiling incl hanging arrangement hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 139 | M & L for non skid coloured ceramic endura tiles heavy duty for outdoor 7 to 8 mm thick, area of each tile exceeding 0.06 sq m but not exceeding 0.11Sq min floors set and jointed in neat cement slurry and pointed in white or coloured cementto match over include 15 mm thick cement screed in CM 1:6 including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as specified and as directed. |
| 140 | S&F Granite (of any type) work 18-20mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified & directed. |
| 141 | S&F sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified & directed. |
| 142 | M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate ) as in foundation filling, sub base for floors/ hard standing etc, complete all as specified and directed. |
| 143 | S&F Welded steel wire fabric of weight not exc 4.0 kg/sqm fixed to wood or steel members, complete all as specified and directed. |
| 144 | M/L of two coats of synthetic enamel paint over a coat of red oxide on new steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth complete all as specified & directed. |
| 145 | S&F Mild steel framed work of Fe-290 Gde-E-165 as in doors or gate of angle or other section with gusset plates,rails, braces etc and fixingitems, complete all as specified and directed. |
| 146 | M&L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment used, excluding laying ofsand cushioning complete allas specified and as directed. Note :- Sand will be measured and paid seperately |
| 147 | M&L sand filling under floors or in foundations including watering and consolidation complete allas specified and as directed. |
| 148 | M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed. |
| 149 | M&L for cement concrete 1:2:4 type B1 using 20mm graded aggregate as in lintels upto1.5m clear span,cills,steps; seismic and other similar bands, coaping, plinth courses, benching, water troughs and the like including weathering,slightly rounded or chamfered angles and throating and necessary formwork complete all as specified and directed |
| 150 | M&L for cement concrete 1:2:4 type B1 using 20mm graded aggregate as in landings, cover slabs (for man holes etc.)chullah hoods,chajjas, water troughs, mangers, shelves and similar articles with plain faces and necessary formwork complete all as specified and directed |
| 151 | M&L for cement concrete 1:3:6 type C-2 in concrete bed to 150mm dia drain pipes including packing under, and haunching againstthe sides of pipes after they are laid and tested; in complete all as specified and directed. |
| 152 | M&L for 150mm dia bore of reinforced concrete pipes,class NP3, laid and jointed complete with collars complete all as specified and directed. |
| 153 | M&L for cuttingintoexistingmanholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed. |
| 154 | M&L Complete removal of existing treatment of wall suface andplaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and as directed. |
| 155 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces completeall as specified and directed by Engineer in Charge |
| 156 | M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface completeall as specified and directed. |
| 157 | Demolition cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 158 | M&L for provide squash court sports wooden flooring (Maple wood) surface boards use in made of klin seasoned (moisture contain of approximately 14% at the time of dispatch), treated \"Maple wood\" finished with 21 mm thick, 57 to 83 mm wide and random length in tongue and groove shape. The edges of the boards will have a finger lock groove and the bottom side with air pass groove and treated with special anti-termite and water-resistant lacquer. Maple wood is the hardest of hard woods and is the recommended wood for squash court. All major tournments are played on maple wood floor only the under frame made of commercial quality pine wood runners of 70 mm x 45 mm, treated with anti-termite solution and fixed on the bottom side with 10 mm thick air cushioned pads, fixed through the two wings at 350 mm x 350 mm installation, IPS subfloor treated with a vapor barrier to be placed on the leveled IPS subfloor before laying the under frame. The runners having air cushion pads to be placed on the vapor barrier in perfect level at 350 mm in 1 direction. The surface board to be screwed to the runner through the tongue only and will lock the screwed tongue by the groove of adjoining board. Ends of the boards will be locked by inserting the wooden fingers through the edge grooves and fixed with suitable adhesive. An expansion of 8 to 10 mm to be left open between the wooden flooring and the surrounding tiled area/ walls finishing, After laying the flooring, the floor boards will be levelled to a uniform surface and appied a thin coat of water-based police on the face complete all as specified and directed. |
| 159 | S&F for sound boards, description (7 feet x 17 inch) - 3 Nos, Tin board of 22 guage fixed in all necessary fittings complete all as specified and directed |
| 160 | Taking down carefully existig copper / alumn point wiring for light / fan / bell / socket 5/15 Amp points complete withfitting and fixtures such as switches, sockets, c/ rosess, holders and bracket fittings with battens / conduits / wires,T/L fittings and making good the disturbed surfacesof walls and roofs etc.and to match with existing colour complete all as specified and directed. |
| 161 | Taking down carefully unserviceable main switches and distribution boards with fuses/ MCB\"s (single phase or three phase) of any capacity all as specified and directed. |
| 162 | S&FPoint wiring complete with 1100 volts grade PVCFRLSinsulated unsheathed cable of copper conductor, multi stranded of size 1.5 Sqmm, single core, drawn through & including PVC rigid concealed conduit, medium grade of suitable size (not less than 20mm dia) duly ISI marked with all accessories such as bends, reducers, spacers, saddles, junction boxes, bakelite sheets, sizes for mounting switch/sockets, fan regulators etc complete with and including continuous earth wire of size 1.5 Sqmm, single core, PVC FRLS copper conductor, insulated, unsheathed, stranded (Green colour) connected to common earth dolly complete all as specified and directedforfollowing : (a)One light/fan/bell/Bldg security light point controlled by one single pole one way switch. |
| 163 | All as per item No. 162 here-in-before but One 3 pin 5 Amp socket outlet point controlled by one switch on Independent board, complete all as specified and directed. |
| 164 | All as per item No. 162 here-in-before but One 3 pin 5 Amp socket outlet point controlled by one switch on sameboard, complete all as specified and directed. |
| 165 | All as per item No. 162 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 2.5 Sqmm PVC FRLS insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 2.5 Sqmm green colours PVC FRLS insulated, unsheathed, stranded copper conductor cable, complete all as specified and directed. |
| 166 | All as per item No. 162 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 4.0 Sqmm PVC FRLS insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 4.0 Sqmm green colours PVC FRLS insulated, unsheathed, stranded copper conductor cable, complete all as specified and directed. |
| 167 | S&F 6 amps, single pole, one way switch urea back piece (IP20), 240V, 50Hz, white in colour, duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 168 | Supply and fixing of switch piano flush button single pole one-way 15 Ampere complete all as specified and directed. |
| 169 | Supply and fixing of socket outlet 5 Ampere, 2 and 3/5 pins, flush type 250 volts AC complete all as specified and directed. |
| 170 | S&F Socket outlet, UNI, 2 in one10 Amps & 20 Amps, white in colour, duly ISI markedcomplete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 171 | S&F Ceiling rose surface type, 240 volts, 50 Hz, 6A, Pilot 3 plate, white in colour, bakelite 65 x 50mm, 3 terminals dulyISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 172 | S&F batten holder, 240 volts, 50 Hz, 6A, white in colour, duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 173 | Supply and fixing LED light fitting 1 x 20 Watt, 220V, AC decorative type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 174 | S&F LED bulb of 9 watt, B22 base, 6500K all as specified and directed. |
| 175 | S&F Factory made single phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 8 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail. suitable for use on 240V, 50Hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as specified and directed. |
| 176 | S&F MCB SPN, 40A - 63Amps, 240 volts, \"C\" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning, complete all as specified and directed. |
| 177 | S&F MCB SP, 32 Amps, 240 volts, \"B\" series, 10KA duly ISI marked, in the MCB DB, complete with connection testing and commissioning, complete all as specified and directed. |
| 178 | M&L for Sub main wiring with two single core 2x6 sqmm FRLS insulated and unsheathed stranded copper conductoralongwith earth wire 6.0 sqmm drawn in FRLS rigid conduit connected to main board complete all as specified and directed (Two runs cable and one number earth wire and suitableFRLS conduit shall measured together as unit length). |
| 179 | Supply & Fix in repair sub main wiring of 6 sqmm PVC insulated unsheathed FRLS cable multistranded copper conductor with earth wire of 6.0 sqmm PVC insulated unsheathed FRLS cable multistranded copper conductor including PVC conduit pipe 25 mm diaall as specified and directed. Note:-Two run of single core 6 sqmm cable and one run single core 6.0 sqmm cable for earth wire and including conduit pipe 25 mm dia shall measured as one length). |
| 180 | S&F exhaust fan heavy duty copper winding with louvers complete of sweep size 300mm, 900 RPM, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection, complete all as specified and directed. |
| 181 | Cutting holes making good the distributed surface, grouting nuts for fixing of Exhaust fans complete all as specified and directed. |
| 182 | S&F LED sleeky bldg street light (Lens) fitting toughened glass of 35 watts, 6000K, including GI bracket bend to shape made out of GI pipe light grade of 25 mm, size up to 1.2 mtr long etc complete with MS clamps made of 25x3mm MS plate, duly painted with two coats of aluminium paint with nuts/ bolts/ washers and all fixing arrangements to wall/ pole, including connecting up with 2 core copper flexible wire of size 23/00.0076 all as specified and directed. Make- KCSAD,Philips/ Bajaj/ Havells. |
| 183 | Supply and fixing of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with highefficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and directed. |
| 184 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and directed. |
| 185 | S & F fan regulator electronic step type socket size and making all necessary connections complete all as specified and directed. |
| 186 | Supply and fix wall mounted fan of size 400 mm sweep AC single phase 230V.Make of fan Crompton/ Bajaj/ Khaitan/ Havells all as direted by Engineer-in-charge. |
| 187 | S & F MCB single pole neutral(SPN) 240 volts, 40 Amps, 10 KA complete all as specified and directed. |
| 188 | Earthing complete with galvanized steel plate elecrode of size60 cm x 60cm x 6.0 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC ( 1:3:6 ) type C-2using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to spoxsed steel surfaces. excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009)complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail