| Sl. No. | Item Description |
| 1 | Dismantling AC Corrugated Sheets as in Roofing including Ridge or Similar Pattern Roof Coverings, complete all as specified and as directed. |
| 2 | Demolition existing Roof Padding including Roof Treatment complete carefully by cutting, chiseling, etc. and cleaning the surfaces by scrapping, booming, bruhing, etc. and removing the rubbish from Site to a distance exc 50.00 Metre but not exc. 100 Metre, complete all as specified and as directed. |
| 3 | Dismantling of Wall and Ceiling Board (Fibre, Pulp, Insulation etc.) or Insulation Board/Slab /Blankets, any thickness including Cover Fillets, complete all as specified and as directed. |
| 4 | Dismantling Wrought Iron or Mild Steel Work, viz. MS Flat Iron (Wind Tie) and Similar Work including MS Bolts, Nuts, etc., complete all as specified and as directed. |
| 5 | Dismantling Timber Scantlings, 40 Sqcm and over in Section, in any Position, in Unframed Work, complete all as specified and as directed. |
| 6 | Dismantling Timber Fillets, Rails, Posts, Rafters, Purlings, etc., under 40 Sqcm in Section, in any Position, as in unframed Work, complete all as specified and as directed. |
| 7 | Demolition Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc, but excluding Ashlar Facings, dressed Stone Work and Pre-cast Concrete Articles of any descriptions, complete all as specified and as directed. |
| 8 | Taking down Cement Plaster of any descrip-tion on Brick Walls, Concrete Surfaces includ -ing racking out joints, hacking for key, scrubb -ing down with Water, remove dust, debries/ rubbish, etc., complete all as specified and as directed. |
| 9 | Taking down chowkhats or frames with shutters (without taking off shutter from frames) of any sizes nexc 1.5 Sqm complete all as specified and directed. |
| 10 | Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm and n.exc 4 Sqm each complete all as specified and directed. |
| 11 | Demolition of Cement Concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 12 | Demolition of Reinforced Cement Concrete of any description and in any Position not otherwise specifically provided for, complete all as specified and as directed. |
| 13 | Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing), and removing rubbish off the Premises, complete all as specified and as directed. |
| 14 | Taking up or down Steel Water Tubing 15mm dia (bore) including Connections and Fittings, Segregating Serviceable Pipes & Fittings, Stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed. |
| 15 | Taking up or down Steel Water Tubing 20mm dia (bore) including Connections and Fittings, Segregating Serviceable Pipes & Fittings, Stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed. |
| 16 | Excavating in post holes (or similar holes) each n. exc. 0.5 cum, getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25 cm watering and removing surplus soil to distance n. exc 50 m and making good surface complete all as specified and directed. |
| 17 | Surface dressing not exc. 150mm deep and getting out in Soft/Loose Soil, complete all as specified and as directed. |
| 18 | M&L Moorum/red bajri filling in floors or pavings , laid in lyers 30 cm in thick spread , levelled and rammed including watering complete all as specifiedand directed by Engr-in-charge. |
| 19 | M&LHardcore (broken stone or boulders) of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 20 | M&LSand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 21 | M&LPlain Cement Concrete 1:3:6 (40 mm graded crushed stone aggregate) type C2as in foundation filling and mass conc, etc., complete all as specified and as directed. |
| 22 | M&L Plain Cement Concrete type C-1, (1:3:6) (40mm graded crushed stone aggregate) as in Coping bed plate,hold fast etc,block benching,channeling slightly rounded or chamfered angle and throating including form work and finishing all exposed faces of cement concrete complete all as specified and as directed. |
| 23 | M&L Anti Termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed |
| 24 | M&L Anti Termite Treatment of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed |
| 25 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, crumple joints, ridge cover, etc fixed with self tapping screws etc; complete all as specified and as directed. |
| 26 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge, fixed with self tapping screw complete all as specified and directed. |
| 27 | M&L for providing cement concrete type B-0 (Using 12.50mm graded stone aggregate) as in padding and benching & filleting all as specified and directed. |
| 28 | Materials and labour for 10mm thick cement plaster in 1:4 surface finished even and smooth with WPC as per manufacture instruction complete all as specified and directed. |
| 29 | M&L Water Proofing Treatment on existing cleaned RCC Roof with the following Specifications and Manufacturer\"s instructions, complete all as specified and as directed :-(a) Preparing and cleaning of fully drysurface as per IS:3067-1966.(b) Applying Bitumen Primer conforming to IS-3384-1986 over the Cleaned Plastered Surface @ 0.40 Litre per Sqm.(c) Applying a layer of APP based Polymeric Membrance; 3.0mm thick (minimum) weighing 3.60 Kilogram per Square Metre (reinforced) with Polyster Non Woven Fabric weighing not less than 160 Grams per Square Metre by Torch application. The overlaps shall be minimum 100mm on the Transverse direction and 75mm on Longitudinal direction.(d) Applying one coat of Aluminium Paint @ 0.11 Litre per Sqm over APP based Polymeric Membrane. |
| 30 | M&L Cutting out existing cracks in concrete surfaces forming grooves of 25mm x 40mm size, cleaning the groove thoroughly with blower, applying primer coat of the mix of IPH CC Resin & Hardner in equal proportion with suitable brush to form a film on the surface of groove, filling the groove with putty made by mixing IPH CC Resin, Hardner and admixture in the proportion of 1:1:4 and finally applying the sealing coat of the same mix and in the manner primer coat is applied with following min. coverage per running metre length of groove :-Material Priming CoatPutty FillingSeal CoatResin 60 Gms100 Gms 40 GmsHardner 60 Gms100 Gms 40 GmsAdmixture-400 Gms- |
| 31 | M&L False ceiling with \"E\" board \"Classic\" , reinforced, designer series, board with HPSC of size 600 mm x 600 mm x 4 mm thick fixed on aluminium powder coated snap grid to support the boards/tiles with aluminium anodised main \"T\" section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and aluminium angle 25mm x 25mm x 1.40mm as on edges/sides including hanging arrangements with 6mm dia GI hooks and clampand applying two coats of oil bound distemper over a coat of alkali resistant primer on exposed surfaces complete all as specified and as directed. |
| 32 | M&L mild steel Work in Tubular Trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conform-ing to IS:1161-1979 grade St.-240, complete all as specified and as directed. |
| 33 | M&L Rolled mild steel section as in main and cross beams, hip and jack rafters, wind tie & purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-410-W (Gde-E-250) quality A complete all as specified and directed. |
| 34 | S&FMild Steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment (Fe-290 Gde-E165) complete all as specified and directed. |
| 35 | S&F16-20mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 11cm but nexc 15cm long complete all as specified and directed |
| 36 | S&F5-10mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 05cm but nexc 10cm long complete all as specified and directed |
| 37 | S&F Mild steeltubes 40 mm bore (Medium Graded) with all fittings & fixedto walls and ceiling for holding clamps of false ceilingcomplete all as specified and as directed. |
| 38 | S&F Mild steel angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 39 | Fixing only PVC coated chain link fencing mild steel galvanised 3.00mm dia (minimum weigth 3Kg/Sqm) of wire and spacing 75mm x 75mm including line wires to any standards, rails and straining bolts including provision of binding wire complete all as specified and directed.Note :- Line wire ,binding wire and bolts/nuts shall be measured and paid separetaly under relevant item of BOQ |
| 40 | Supply only PVC coated chain link fencing mild steel galvanised 3.00mm dia (minimum weigth 3Kg/Sqm) of wire and spacing 75mm x 75mm including 8mm dia round bar as in line wires to any standards, rails and straining bolts including provision of binding wire complete all as specified and directed. |
| 41 | Supply only Mild steel round Bars 8 mm dia , cut to length, bent to shape required including crank-ing, bending and bindingwithgalvanised Steel Wire not less than 0.90 mm and stapleas in line wirecomplete all as specified and as directed. |
| 42 | M&L fly ash bricks pulverizes using class designation 75 bricksstraigth or curved on plan exc 6m mean radius built in CM (1:6) cmplete all as specified and directed. |
| 43 | Labour only Brick Work using Except bricks obtained from demolition, Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:4, complete all as specified and as directed. |
| 44 | M&L Brick Work with class designation 75, Half-Brick thick, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed. |
| 45 | M&L for 5 mm thick rendering on brick or concrete surfaces of wall in CM 1:3 and finished even and smooth without using extra cement complete all as specified & directed. |
| 46 | M&L Rendering15mm thick in Cement Mortar 1:6 on Brick Walls finishing Surfaces, finishing plastered surfaces Even and smooth without using Extra Cement complete all as specified and as directed. |
| 47 | M&L 15 mm thick rendering in cement mortar (1:4) on fair faces of brick or concrete externalsurfaces in two layers (each 10+5 mm thick) finished even and fair without using extra cement using water proofing compound on top layeras per manufactures instruction on external wall surface completeall as specified and directed. |
| 48 | M&L Applying polymer modified cement mortar rendering 20mm thick in CM 1:3 on wall duly mixing polymer modifier \"Nitobond SBR of M/s Forsoc Chemical India (Pvt) Ltd\" or \"Hind Styrene BR of Hindcon Chemical Ltd\" or equivalent as per list of makeIndustries @ 7 Litre per bag of cementcomplete finished even and smooth without using extra cement as per manufacturer\"s specification complete all as specified and directed. |
| 49 | \"Supply only\" liquid water proofing compound (ISI marked) complete all as specified and directed.Make:- STP NO 1/ PEDILITE(DR FIXIT)/ FOSROC/ CICO/ SIKA/ Icannano |
| 50 | S&F Welded steel wire fabric weight not more than 4Kg/Sqm fitted by mild steel nails complete all as specified and directed. |
| 51 | M&L for Pressed steel frames for doors with one or more rebates size of frame 125 x 60 mm including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed.Note:- Pressed Steel Frame should be filled with PCC 1:3:6 Type C-0 (Using 12.50mm graded stone aggregate) and cost of PCC shall be deemed included in quoted rate |
| 52 | M&L for Pressed steel frames for doors with one or more rebates size of frame 105 x 60 mm including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed.Note:- Pressed Steel Frame should be filled with PCC 1:3:6 Type C-0 (Using 12.50mm graded stone aggregate) and cost of PCC shall be deemed included in quoted rate |
| 53 | M&L mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (anealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 54 | M&L mild steel TMT Bars 8 mm dia , cut to length, bent to shape required including crank-ing, bending and bindingwith and including Mild Steel Wire (annealed) not less than 0.90 mm, as in stirrups spacers and binders complete all as specified and as directed. |
| 55 | 1 M&LReinforced cement concrete (Nominal Mix) type A-1 (1:1.5:3) (Using 20mm graded crushed stone aggregate) as in Beams, cantilevers, bressumm-ers, lintels & shelves over 1.5m spanetc complete all as specified and directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 56 | M&L Use and waste for formwork to Sides and Soffits of Floor or Roof Beams, Beam Haunchings, Girders, Bres-Summers, Lintels, Cantilevers, Shelves including supports, overhangs, etc. also splays between floors and beams, etc., flat, rough finished surfaces of concrete, complete all as specified and as directed. |
| 57 | M&L Plain Cement Concrete type B-1, (1:2:4) (20mm graded crushed stone aggregate) as in Coping bed plate,hold fast etc,block benching,channeling slightly rounded or chamfered angle and throating including form work and finishing all exposed faces of cement concrete complete all as specified and as directed. |
| 58 | S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides fitted to cowkhats complete all as specified and directed |
| 59 | S&F for 2nd class hardwood 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats as specified in SSR Part-I 2009. |
| 60 | S&F for Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 61 | S&F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. Square tube,fixing in opening as per Specifications and Drawings shown in MES Schedule Part-II, complete all as specified and as directed. |
| 62 | S&F for Factory Made Solid PVC Moulded Door Shutter With Wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site complete all as specified and directed. |
| 63 | M&L 1.50mm thick power coated aluminium , three track sliding window with three nosshutters made ofaluminium section as per drawing no CWE/KOL/TD-33 of section no 1F-1F including necessary jointing cleats, glazing clips, rubber neoprene packing, roller,locking arrangement, handles 2 Nos , anodised aluminium snap beading screws etc. including Tinted glass with sheet glass 4.80mm thick , pin head type and glazing in squaresexc 0.5 sq. M in half pane and including stainless steel wire cloth 0.36mm nominal dia of wire and average width of aderture 1.40mm in half pane. Complete all as specified and as directed.Note Nos :-All window memberincluding fitting & fixture i.eframe, track, shutter frame, etc shall be deem toincluded quoted rate. Only measure opening size of window. |
| 64 | S&F Powder coated aluminium ventilators with louvers and glazing including frame of section over all size of window 600X450mm complete with following specification.(a) Alu frames of size 45x45x1.2mm (b) Rail & Stile 45x45x1.2mm thick (c) 4.80mm thick frosted sheet glassNote :- All ventilators/louvers memberincluding fitting & fixture shall be deem toincluded quoted rate. Only measure opening size of ventilators/louvers |
| 65 | M&L Drapery rod made ofelectric resistance welded MS pipe of 20mm dia having a coating of corrugated virgin PVC extrusionandcover with ABS plastic complete all as specified and directed. |
| 66 | S&FEnd Stopper, Decorative typefor drapery rod and includingclosed type stainless steelbrackets fixed on wall complete all as specified and directed. |
| 67 | S&F Stainless Steel Butt Hinges, size of Hinges 100mm, medium weight, Cold Rolled and fixed, complete all as specified and as directed |
| 68 | S&FAluminium anodised, barrel tower bolts of extruded section, 200 mm long and fixed with steel screws complete all as specified and directed. |
| 69 | S&F 300mm long Aluminium alloy, anodised, Sliding Door Bolt with Hasp, Staple (Bolt type) and Fixing Clips of Sheet, Cast or Extruded Sections and Fixing Bolts and Sliding Bolts of Extruded Sections or Cast-Aluminium alloy and fixed, complete all as specified and as directed. |
| 70 | S&F Aluminium alloy Handle 150mm long, Extruded Section, Fabricated type, anodized and fixed, complete all as specified and as directed. |
| 71 | S&F Floor door stopper of steel body and overall length of cover plate 150 mm and tongue anodised with hard drawn steel spring as in repair complete all as specified and directed. |
| 72 | M&L 18/19 mm thick Medium density fibre board, exterior grade, fixed to timber framework with screws complete all as specified and directed. |
| 73 | S&F Continous (piano) mild steel, bright finish or electro galvanised Width of flaps (When open) 30mm complete all as specified and directed. |
| 74 | S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of brass polished bright finishedcomplete all as specified and as directed. |
| 75 | S&FMild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete complete all as specified and as directed. |
| 76 | M&L mild steel Framed Work such as Grills, Gratings, etc. with ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework of Water Tanks and Similar Work, conforming to Fe-290, Gde-E-165, complete all as speci-fied and as directed. |
| 77 | M&L Cement Concrete type D2 (1:4:8) using 40mm graded aggregate 75mm thick in Sub-bases, finishing concrete surfaces fair and even, complete all as specified and as directed. |
| 78 | M&L Cement Concretetype C2 (1:3:6) using 40mm graded crushed stone aggregate 75mm thick as in Plinth Protection, etc. laid in alternate Bays, finished Concrete Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed.Note:- Construction joints will be provided at interval of 2.5m length and filled with bitumen 80/20 mix with sand in ratio of 1:3 and cost of the same shall be deemed included in quoted rate |
| 79 | M&L 100mm thick PCC (1:4:8) type D-2 (Using 40mm graded stone aggregate) as in sub base for path/hard standing cement complete all as specified. |
| 80 | M&L Cement Concrete type B0 (1:2:4) (12.5mm graded aggregate) 25mm thick, in Flooring, finishing concrete surfaces fair and even, complete all as specified and as directed. |
| 81 | M&L joint free non skid ceramic coloured tiles 7-8mm thick (square/rectangular) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm in floor set and jointed in in neat cement slurry and pointed in cloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 82 | M&L Non-skid Ceramic Coloured Tiles, 7.0mm to 8.0mm thick (square/rectangular), area of each tile exc 0.18 sqm but not exc 0.38 sqmin Floors, etc. Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over 15mm thick screed bed (1:6) in cement mortarcomplete all as specified and as directed. |
| 83 | M&L Non-skid Ceramic Coloured Tiles, 7.0mm to 8.0mm thick (square/rectangular), area of each tile exc 0.18 sqm but not exc 0.38 sqm on Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over and including 10mm thick backing layerin cement mortar (1:4) complete all as specified and as directed. |
| 84 | M&L Glazed Ceramic Coloured Tile 450 x 350 x 7.0mm thick on Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over and including 10mm thick backing layerin cement mortar (1:4) complete all as specified and as directed. |
| 85 | M&L Granite (of any type) Work (Table rubbed and polished) 18 to 20 mm thick, in Steps, Cooking Platforms and like, Set in Screed bed of 20mm thick in Cement Mortar 1:4 including Pointing in White Cement 1:2 using Marble Dust with admixture of Pigment to match with Shade of Granite including Cutting and Polishing including half round edges, complete all as specified and as directed. |
| 86 | S&F CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11fittings fixed on Walls, Ceiling or laid in Floors or any other Situation,etc up to four stories height of bldgs. complete as all specified and as directed. |
| 87 | S&F CPVC pipes 25 mm outer diameter of SDR 11 & plain CPVC SDR 11fittings fixed on Walls, Ceiling or laid in Floors or any other Situation,etc up to four stories height of bldgs. complete as all specified and as directed. |
| 88 | M&L Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth in brick walls etc complete all as specified and as directed. |
| 89 | S&F in repair Vitreous China wash down water closet pan (ISI Marked, Ist Quality) including P or S trap (pedestal pattern), white or in matching colour of tiles (excluding flushing cistern and flush pipe) including plastic water closet seat, white or in matching colour , closed pattern with flat bottom, and cover and mild steel chromium plated or aluminized hinging device and wash down water closet complete all as specified and as directed. |
| 90 | S&F Vitreous China Wash Hand Basin 550x400mm in size, White (Flat Back or Angle Back Type) with 32mm dia Brass Chromium Plated Waste Fitting, a pair of Cast Iron Brackets duly painted including Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 including taking down/out unserviceable Wash Hand Basin and connected Items, complete all as specified and as directed. |
| 91 | Supply and fixing in repair 10 litre capacity low level PVC flushing cistern (any colour), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete as directed. |
| 92 | S&F in repair PVC (SWR)Pipe 110mm bore (dia), single socketed, in any length with Rubber Ring Joints fixed to Walls, ceilings and floors with pvc clamps complete all as specified and as directed. |
| 93 | S&F in repair PVC (SWR) Soil, Waste and Ventilating Pipe 110mm bore (dia), Type \"B\" double socketed, in any length with Rubber Ring Joints fixed to Walls, complete all as specified and as directed. |
| 94 | S&F in repair PVC (SWR) bend any radius 110mm bore complete all as specified and directed. |
| 95 | S&F in repair PVC (SWR) junction single (single T) equal or unequal 110mm bore complete all as specified and directed. |
| 96 | S&F in repair UPVC (SWR) Nahani/Floor Trap 75mm bore (dia) Outlet, Plain with Grating and Jointing with Solvent Cement, as in repair complete all as specified and as directed. |
| 97 | S&F3-in-1 wall mixer for Hot & Cold water supply with telephonic shower arrarengement, brass chromium plated fancy type, screwed down for 15mm boreiron pipe incl necessary fittings & fixtures etc.as in repaircomplete all as specified and directed. |
| 98 | S&F Central hole for Hot and Cold water supply basin mixer, brass chromium plated screwed down for iron pipes,including necessary fittings etc as in repair , complete all as specified and as directed. |
| 99 | S & F in repair for 15mm bore brass chromium plated Angular Valve with Wall Flange complete all as specified and directed. |
| 100 | S&F Brass chromium plated fancy type bib cockscrewed for 15 mm bore of pipeetc. as in repair complete all as specified & directed. |
| 101 | S & F in repair for brass chromium plated two in one tap with Wall Flange screwed for 15 mm bore pipe complete all as specified and directed |
| 102 | S&F Brass chromium plated long body bib cock with Wall Flangescrewed for 15 mm bore pipeas inrepair complete all as specified and directed |
| 103 | S & F work in repair for ABS body chrome plated shower rose 125mm size including fixing to steel pipe or union complete all as specified and directed |
| 104 | S & F in repair for shower arm 240mm long round shape with flage including fixing to steel pipe or union complete all as specified and directed |
| 105 | S&F Tublar Towel Rail 20mm dia, ‘D’ type 600mm long between Flanges Brass Chromi-mum Plated and fixed-in-repairs, completeall as specified and as directed. |
| 106 | S&F PVC bathroom cabinet box with mirror, shutter type of size 500X400 fixed on wallswith wooden plugs and and chromium plated brass screw and cup washer as in repaircomplete all as specified & directed. |
| 107 | S&F Kitchen sink of overall size 495 mm x 420 mm and bowl size 410 mm x 330 mm x 160 mm depth, made out of 1 mm thick stainless steel sheet, with plugs, washers, 32 mm dia PVC waste pipe, bedding in cement mortar including fixing cast iron cantilever brackets (of suitable size), connecting union and making good with cement mortar 1:3 to match with the existing surfaces etc complete all as specified and as directed. |
| 108 | S&F stainless steel utencil plate rack (size 24\"\" x 30\"\" x 10\"\") using 0.8mm thicksheet with all fittings accessories complete as directed. |
| 109 | S & F in repair for chromium plated Health faucet with 8mm Dia, 1.2 Meter long flexible tube and wall hook with N.R.V (Back Flow Preventer) complete as directed. |
| 110 | S&F PVC connection 15mm size with PTMT nut of length 450mm complete all as specified and directed. |
| 111 | S&F Rotational Moulded Polyethylene (HDPE) Water Storage Tank 1000 Litre Capacity (Cylindrical Vertical with Closed Top), Black in Colour, Three Layered Construction, hoisted and fixed in Position all specified in MES Schedule Part-I including provision of 25mm x 100mm GI nippples with check nuts for inlet, outlet wash and overflow pipe,Ball Valve 25mm dia having mini -mum weight 210 Grams, high pressure with epoxy coated Aluminium Rod and high density Plastic Ball including Lowering of old/unserviceable Water Storage Tank of any description, complete all as specified and as directed. |
| 112 | M&L Cement Concrete type B2 PCC (1:2:4) using 40mm graded aggregate 150mm thick in Sub-bases, finishing concrete surfaces fair and even, complete all as specified and as directed. |
| 113 | M&L 20mm thick Wearproof topping as specified (incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner) complete all as specified and as directed. |
| 114 | \"Supply only\" metallic hardner (ISI marked) complete all as specified and directed. |
| 115 | M&L Preparing new Surfaces of wall and applying Three Coats of White Wash, complete all as specified and as directed. |
| 116 | M&L preparing new plastered surfaces of wall and and applying Two Coats of Distemper Oil Emulsion over a coat of primer over andapplied over and including 2mm thick water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and as directed. |
| 117 | M&L Complete removal of existing Treatment of old decorated Surfaces of Walls andapplying Two Coats of DistemperOil Emulsionover a coat of primer applied over and including 2mm thick water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 118 | M&L Preparing new plaster surfaces and Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work/new work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed. |
| 119 | M&L Complete removal of old decorated surfaces and Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work/new work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed. |
| 120 | M&L Preparing new Wood and Wood Based Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Pink Primer, complete all as specified and as directed. |
| 121 | M&L Preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel plaint over a coat of red oxide all as specified and directed by Engineer-in-Charge. |
| 122 | M&L Preparation of new steel surfaces of any description, n exc. 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel plaint over a coat of red oxide all as specified and directed by Engineer-in-Charge. |
| 123 | M&L preparation ofold painted steel surface over 10cm width or girth not otherwise described and applying a coat of synthetic enamel paint complete all as specified and directed. |
| 124 | M&L Preparing surfaces end of steel post materials new of any description and girth not otherwise described and treating with tar or coal tar black paint at ends of post back of chowkats etc area tarred exc. 0.10 Sqm but n.exc 0.50 Sqm each. Including sanding with clean sharp sand after tarred complete all as specified & directed. |
| 125 | Taking down point wiring (light, fan, socket and power complete including fixtures and fittings such as switches ceiling roses, pendents , regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody for refixing or for taking credit (credit for above items should be made as per conditions separately) and making good distrubed surfaces of walls, floors, etc. including cleaning all and specified and directed. |
| 126 | M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium dutywith all accessories including fabricated 1.6 mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets,regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified including Cutting chase, pinning in making good to facings where required and pointing in cement mortar 1:3 for one light or fanpoint controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. |
| 127 | All as per item No.128.00 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge. |
| 128 | All as per item No.128.00here-in-before but one 3 pin 5 ampsswitch socket outlet on the independent board with other switch complete all as specified and directed by Engineer-in-charge. |
| 129 | All as per item No.128.00 mentioned here-in-before but using 2.5 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board including 2.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead complete all as specified and directed by Engineer-in-Charge. |
| 130 | All as per item No.128.00 mentioned here-in-before but using 4 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board or for AC Starter including 4 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth leadcomplete all as specified and directed by Engineer-in-Charge. |
| 131 | M&L for point wiring with PVC insulated unsheated stranded copper conductor cable FRLH/S of size 1.5 sq mm in and including PVC casing caping of required width with all necessary fittings with sunk cast iron /pressed steel terminal box of1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 1.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light / ceiling fan/exhaust fan / bell controlled by one switch , one way complete all as specified and directed by Engineer incharge. |
| 132 | All as per item No.133.00 mentioned here-in-before but 3 pin 5 amps socket out let point same board with other switches of cables of 1.5 sqmm |
| 133 | All as per item No.133.00 mentioned here-in-before but for one 5 amp switch socket combination on independent board with cables of 1.5 sqmm size |
| 134 | All as per item No.133.00 mentioned here-in-before but using 2.5 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board including 2.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead complete all as specified and directed by Engineer-in-Charge. |
| 135 | S&F Switch piano, flush type, SP, one way, 5/6 Amps 230/240 Volts, white/ivory finish complete all as specified and directed. |
| 136 | S&FSwitch socket combination multipurpose 2 in 1, 5 pin 6 Amps 230/240 volt flushtype complete all as specified and as directed. |
| 137 | S&FSocket outlet 3/5 pin, 6 Amps, 240 volt flushtype complete all as specified and as directed. |
| 138 | S&FSwitch socket combination multipurpose 2 in 1, 6 pin 15 Amps 230/240 volt flushtype complete all as specified and as directed. |
| 139 | S&F Ceiling rose surface bakelitethree terminals 240 volts complete all as specified and as directed. |
| 140 | S&F bell push flush type 5 Amps 230V complete all as specified and directed by Engineer-in-Charge. |
| 141 | S&F call bell, ding dong AC 230 volt single pole (ding dong type) complete all as specified and directed by Engineer-in-Charge. |
| 142 | Supply and fixing ceiling Fan regulator step type240 Volt complete all as specified and directed by the Engr-in-Charge. |
| 143 | S&F A C starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewire with 6 module box with cover plate and frame complete all as specified and directed by Engineer-in-Charge. |
| 144 | S&F 9W LED bulb, 6500k, PF>0.9, CRI>80 lumen efficacy warmlight/ natural white alongwith PVC Lamp holder complete all as specified and directed by the Engr-in-Charge. |
| 145 | S&F Energy efficientLED fittings of capacity 1 x 10W suspended type / wall mounted type complete with LED tube Lamp and fitting with copper flexible PVC cable of 0.50 sq mm twin core not more than one metre in length complete all as specified and as directed. |
| 146 | S&F Energy efficientLED fittings of capacity 1 x 20W suspended type / wall mounted type complete with LED tube Lamp and fitting with copper flexible PVC cable of 0.50 sq mm twin core not more than one metre in length complete all as specified and as directed. |
| 147 | S&F building security light pressure die cast housing with individual LEDs with modular secondary optics security light luminaires 35 watt LED with 32mm dia light grade GI pipe bent to shape of 45\"\" 1.5 mtr long and nuts bolts including fixing arrangement after taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge. |
| 148 | Taking down unserviceable rusted / damaged MCB DBs of any type and way along with any type MCB and keeping serviceable MCB in safe custody in re-use in the work and making good to the distubed surfaces of walls etc. complete all as specified and as directed. |
| 149 | S&F Sheet metal enclosure for DB\"s when MCBs to be used 4 way single pole and neutral double door with 200 amps ratedbus bar complete 240 volts complete all as specified and as directed. |
| 150 | S&F Sheet metal enclosure for DB\"s when MCBs to be used 8 way single pole and neutral double door with 200 amps ratedbus bar complete 240 volts complete all as specified and as directed. |
| 151 | S&F Sheet metal enclosure for DB\"s when MCBs to be used 12 way single pole and neutral double door with 200 amps ratedbus bar complete 240 volts complete all as specified and as directed. |
| 152 | S&F MCB 6 to 32 Amps, SP, 240 Volts , \"C\" curve breaking capacity 10 kAcompleteall as specified and as directed. |
| 153 | S&FMCB 32 Amps, DP 240 Volts ,C- Curve breaking capacity 10 KA including necessary connection complete all as specified and as directed. |
| 154 | S&F MCB DP 40 to 63 amps 240 volts 10KA breaking capacity complete all as specified. |
| 155 | Taking down old burnt/unserviceable submain wiring with aluminum/copper conductor PVC insulated cable of any size drawn through PVC casing caping/ PVC Conduit pipeincluding GI wire accessories etc. and making good disturbed surfaces of walls, floors, etccomplete all as specified and directed. |
| 156 | M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 4.0 Sqmm as earth lead drawninto rigid non metalic PVC conduit of size 20 mm dia including all fittings complete all as specified and as directed.Note:- Two runsof 4 Sqmm conductor as main wireand one run of 4 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit. |
| 157 | S&F sub main wiring two run of single core PVC insulated unsheathed stranded copper conductor of size 6 sqmm & one run of PVC insulated unsheathed stranded copper conductor of size 6 sqm as earth lead drawing into rigid non metalic PVC conduit of size 20mm diacomplete all as specified. Note:- Two runsof 6 Sqmm conductor as main wireand one run of 6 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit. |
| 158 | S&F sub main wiring two run of single core PVC insulated unsheathed stranded copper conductor of size 10 sqmm & one run of PVC insulated unsheathed stranded copper conductor of size 10 sqm as earth lead drawing into rigid non metalic PVC conduit of size 20mm dia complete all as specified. Note:- Two runsof 10 Sqmm conductor as main wireand one run of 10 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit. |
| 159 | Taking down and refixing of electric water heater storage type of any capacity in same position or other position and connection complete all as specified and directed |
| 160 | Taking down and opening out the blades of ceiling fan/wall mounted fan/ exhaust fan of any sweepfor cleaning and refixing of fan at same location or any other situationafter minor repair complete all as specified and as directed. |
| 161 | Materials and labour Earthing complete with galvanised steel earth plate electrode 60 Cm x 60 Cm x 6.00 mm thick buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, wire projected by 15 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 Cm c/c both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-Icomplete all as specified and as directed. |
| 162 | Materials and labour Earthing complete with galvanised steel earth plate electrode 60 Cm x 60 Cm x 6.00 mm thick buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 25 x4mm dia as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, strip protected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 Cm c/c both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-Icomplete all as specified and as directed. |
| 163 | Excavation in trenches not exc. 1.5 Metre wide and not exc. 1.50 Metre in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes, cable etc. not exc. 10 Sqm on plan and not exc. 1.50 Metre in depth and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 164 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 Cm as in soft/loose soil complete all as specified and directed. |
| 165 | Removing excavated material ( soils of any type) n exc. 50 mand depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 166 | Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge.Note:- Thickness after punning down shall be measured for payment. |
| 167 | Materials and Labour Cutting existing road / path etc for taking out cable and proction pipe and making good the disturbed surfaces with cement concrete type C2 ( 1:3:6,) using 40mm graded crushed stone aggregates) of suitable depth complete all as directed by Engineer-in-Charge. |
| 168 | M&L for25mm bore GI tubes medium grade in trenches with all fixing accessoires (clamps, nut, bolt and washer etc) complete all as specified and directed. |
| 169 | M&L for80mm bore GI tubes light grade for cable protectionwith all fixing accessoires (clamps, nut, bolt and washer etc) complete all as specified and directed. |
| 170 | Supply and laying in trenches Bricks, sub class \"B\" over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge. |
| 171 | Taking out unserviceable UG cables of any type and any sizes from trenches etc and removing from the site of work complete all as specified and directed.Note:- (i) Serviceable bricks obtained shall be stacked properly for re-use. (ii) Excavation and earth work shall be measured and paid separately under relevant item of these schedule. |
| 172 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 16 Sqmm 4 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge. |
| 173 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 25 Sqmm 4 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge. |
| 174 | Supply and fix 25mm bore Gun metal, globe or gate valves (ISI marked) ( Class-I) with iron wheel head, screwed both ends complete as specified and as directed. |
| 175 | M&L for Cutting, drilling & tapping ofexisting CI/DI pipe line for addn/ altn or for taking down of branch connection/ insertion of pipe by necessary tools with out damaging the pipe line as required of 25mm to 80 mm dia complete all as specified. |
| 176 | S&F Aluminium strip 20x3.15mm with Insulator and fixing screws etc for roof conductors and down conductors above ground complete all as specified and as directed. |
| 177 | S&F Galvanised iron strip of size 25 x 4 mm with saddles and fixing screws etc buried in ground complete all as specified and as directed. |
| 178 | S&F Air termination aluminium single pointed rod 12 mm dia, 300 mm long complete all as specified and as directed. |
| 179 | Supply and fix test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos 8mm dia 25mm long hex head screw complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail