| 1 | Carrying out servicing/maint ofDG Set of Capacity more than 20 KVA but not more than 82.5 KVA set, \"Make : \" As availabIe at site\"including \"B\" check as per manufacturers manualthrough authorised dealer of DG set manufacturer of existing DG Make and testing of DG set completeall as specified and directed by Engineer-in-Charge. Note :- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separately as \"Supply only\" items as mentioned below and shall be of make- as available at site\"as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the quoted unit rate by the tenderer against item No.1(i)Any minor parts such as screws, washers, split pin , circlip etc shall be supplied by the firm, rate for the same shall be deemed to be included in the quoted unit rate.(ii) The Job shall be carried out after every four hundred hrs run of DG Set andshall be measured and paid separately(iii) The Item Include Servicing and cleaning of radiator and taking down fuel tank and cleaning and removing of scale and sludge. |
| 2 | Carrying out servicing/maint ofDG Set of Capacity more than 100 KVA but not more than 250 KVA set, \"Make : \" As availabIe at site\"including \"B\" check as per manufacturers manualthrough authorised dealer of DG set manufacturer of existing DG Make and testing of DG setcompleteall as specified and directed by Engineer-in-Charge. Note :- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separately as \"Supply only\" items as mentioned below and shall be of make- as available at site\"as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the quoted unit rate by the tenderer against item No.1 above(i)Any minor parts such as screws, washers, split pin , circlip etc shall be supplied by the firm, rate for the same shall be deemed to be included in the quoted unit rate.(ii) The Job shall be carried out after every four hundred hrs run of DG Set andshall be measured and paid separately(iii) The Item Include Servicing and cleaning of radiator and taking down fuel tank and cleaning and removing of scale and sludge. |
| 3 | Supply only Lub oil filters (Engine Oil Filters) |
| 4 | LF 16087 (Make:-Fleetguard / Greaves /Kirloskar) |
| 5 | LF3959(Make:- Fleetguard/Greaves /Kirloskar) |
| 6 | Oil filter OC 1654(500 ML)(Make:- Fleetguard/Greaves/Kirloskar) |
| 7 | Oil filter 500 Ml (Make:- Fleetguard//Greaves/Kirloskar) |
| 8 | Oil filter 1Ltr (Make:- Fleetguard//Greaves/Kirloskar) |
| 9 | Supply onlyDiesel filters (Fuel Filters) |
| 10 | FS 1275(Make:-Fleetguard/Greaves /Mahale) |
| 11 | FF5052(Make:- Fleetguard /Greaves /Mahale) |
| 12 | F F5031205 (Make:- Fleetguard/Greaves/Kirloskar) |
| 13 | Paper filter KX 409 Kit Set (500 ml) (Make:- Mahle/Greaves/Kirloskar) |
| 14 | Paper filter set1 ltr (Make:- Mahle/Greaves/Kirloskar) |
| 15 | Supply only Air clean element primaryNo-141109234243 (Make:- Greaves/Kirloskar/Fleet Guard) |
| 16 | Supply only Air clean element Secondary141109234242 (Make:- Greaves/Kirloskar/Fleet Guard) |
| 17 | Supply only HoseATS Coolent Pipe No-161228611146(make-Greaves) |
| 18 | Supply only HoseSS Br Pipe No-161228611136(make-Greaves) |
| 19 | Supply only Hose pipe & Flexible pipe complete set. (make-Fenner/Poly-F/ Roulunos). |
| 20 | Supply only Fan belt for water pump/ alternator No-AX 46/1198 Ld (make-Fenner/Poly-F/ Roulunos/Contitech). |
| 21 | Repair/servicingof radiator assembly with intercooler of DG Set of Cap more than 100 KVA but not more than 250 KVA set,\" after dismanteling and removing cooling fans, guard plates and lowering the same from engine after draining out coolantfrom radiator and scrapping / removing sludge / scale inside tank with acid including replacement MS tank (bottom portion) at rusted portion by cutting/ welding / brazing with 2mm thick copper plate including painting. Remounting the same at its original position and replacement of pre mixed coolent as per the ratio fixed by manufacturer and testing completeall as specified and directed by Engineer-in-Charge.(Note- Pre mixed coolant shall be measured and paid separately under relevant item of schedule)(ii) The Job shall be carried out after every four hundred hrs run of DG Set andshall be measured and paid separately. |
| 22 | Dismantling and opening of turbo charger assembly ofDG Set of Cap more than 100 KVA but not more than 250 KVA set, and repair/overhauling and replacement of turbo charger kit and all type ofspare partsincluding refixing, testing completeall as specified and directed by Engineer-in-Charge. (ii) The Job shall be carried out after everyfour hundred hrs run of DG Set andshall be measured and paid separately. |
| 23 | Dismantling and taking down alternator assembly from existing engine and transporting to workshop and carry out servicing / maintenance of alternator unit of capacity DG Set of Cap more than 20 KVA but not more than 82.5 KVA set per the phase work :- (a) Opening of Alternator and cleaning / removing dust from armature and field coil. (b) Cleaning of used / old lubricated substances drive/non drive end bearings. (c)Cleaning end checking of AVR unit (d) Checking and tightening of coupling bolts and replacement of rubber inserts.(e) M&L for carrying out heat varnishing for field and armature coil and kept in heating chamber for 48 hours for drying properly.(f)Replacement of Bearings as per existing size.(g) Reassembling complete unit and carrying out testing at workshop and transportation to installation and coupling with DG Set including necessary alignment, cable connections completeall as specified and directed by Engineer-in-Charge. (h) The quoted rates shall deemed to be included cost of transportation to and from station to authorized service centre and back. |
| 24 | All Asper item no 7 above but the cap Of DG Setmore than 100 KVA but not more than 250 KVA , Make : \" As available at site\" |
| 25 | Taking out carefully unserviceable fuel injector Nozzle& Injection pump assembly of DG Set of capacity 20KVA but not more than 100 KVA DG set , cleaning/ oiling/servicing fuel injector pump assembly, recalibration of Fuel Injector Pump and nozzleafter repairing unserviceable nozzles, re-assembling and fixing the same in position and testing the Fuel Injector Pump assembly completeall as specified and directed by Engineer-in-Charge. Note (i)Repairs/servicing / reassembling and testing of Fuelinjector& injection pump shall be carried out through an authorised service centre on fully automatic testing machine. (ii) The quoted rates against the item shall deem to include for fixing and replacing of the serviceable parts in position and replacement of unserviceable parts with new parts, such as nuts, bolts, washers, locking nuts,’O’ rings, nozzle, plunger, barrel, governor plunger, pressure regulator, weight carrier assembly, spring pack assembly,gear pump repair kit etc.New spare parts deemed to be included in the quoted rates. (iii) The quoted rates shall deemed to be included cost of transportation to and from station toauthorized service centre and Back.(iv) The Job shall be carried out after every four hundred hrs run of DG Set andshall be measured and paid separately. |
| 26 | All As per Srl Item No 9 above but the cap Of DG Setmore than 100 KVA but not more than 250 KVA , Make : \" As available at site\" |
| 27 | S&F in repair/ replacement ofSelf starter/Cranking motor, auto lock, 12/24Vof existing make or As available at siteon the 20 KVA to 100 KVADG Setand taking out u/s self starter from DG set completeall as specified and directed by Engineer-in-Charge. |
| 28 | S&F in repair/ replacement ofSelf starter/Cranking motor, auto lock, 12/24Vof existing make or As available at siteon the more than 100KVA but not more than 250KVADG Setcompleteall as specified and directed by Engineer-in-Charge. |
| 29 | S&F in repair/ replacement ofAlternater for battery charging, , 12/24Vof existing make or As available at siteon the 20 kVA to 100 KVA DG Setand taking out u/s self starter from DG set completeall as specified and directed by Engineer-in-Charge. |
| 30 | S&F in repair/ replacement ofAlternater for battery charging, , 12/24Vof existing make or As available at siteon the more than 100 KVA but not more than 250 KVADG Setand taking out u/s self starter from DG set completeall as specified and directed by Engineer-in-Charge. |
| 31 | S&F in repair/replacementof turbo charger assembly ofthe 20 kVA to 100 KVA DG Set make Sudhir CS500D5P or As available at site testing completeall as specified and directed by Engineer-in-Charge. |
| 32 | S&F in repair/replacementof turbo charger assembly of more than 100 KVA but not more than 250 KVA Set makeAs available at site testing completeall as specified and directed by Engineer-in-Charge. |
| 33 | S&F in repair /Replacement of water pump and replacement of water kit and water seal and connected item of20 KVA to 100 KVA DG Setas per make available at site completeall as specified and directed by Engineer-in-Charge. |
| 34 | S&F in repair /Replacement of water pump and replacement of water kit and water seal and connected item of more than 100 KVA but not more than 250 KVA DG Set as per make available at site completeall as specified and directed by Engineer-in-Charge. |
| 35 | S&F in repair/ replacement of control unit/ panelincluding all accessories and mounting incl base card of 20 KVA to 100 KVADG Seas per make available at site installed at Power House Make Sudhir completeall as specified and directed by Engineer-in-Charge. |
| 36 | S&F in repair/ replacement of control unit/ panelincluding all accessories and mounting incl base card of more than 100 KVA but not more than 250 KVA DG Set as per make available at site installed at Power House completeall as specified and directed by Engineer-in-Charge. |
| 37 | S&F in repair/ReplacementAVR unit suitable for DG set upto250 KVA capacity as per make available at site completeall as specified and directed by Engineer-in-Charge. |
| 38 | Supply only lubrication oil SAE-40 ( 15 W 40 grade CI 4) of Make:Castrol, Volvoline,Greaves completeall as specified and directed by Engineer-in-Charge. |
| 39 | Supply only Jute cotton waste (as per sample) for cleaning & day to day maintenance of silencer & DG set installed at different location at this station completeall as specified and directed by Engineer-in-Charge. |
| 40 | Taking down,repair and refixing to DGs soundproof doors broken hinges and handles of any make and size/Capacity including fixing with suitable size of broken door hinges with nuts,bolts or welding as per site requirements complete all as specified and directed by Engr-in-Charge. |
| 41 | M&L in repairfor complete wiring harness of required size with sleeves thimbles, lugs indicator lamp, push button and starting switch etc for DG set of any capacity completeall as specified and directed by Engineer-in-Charge. |
| 42 | S&F in repair/ replacement of any type of sensor/relayviz-o-viz triping relay cooling sensor, lubrication sensor or any type required for 100 KVA to 250 KVA ofas per sample or as per make available at site completeall as specified and directed by Engineer-in-Charge. |
| 43 | S&F Battery for starting of DG set of cap 150 AH with copper Lead & clampcompleteall as specified and directed by Engineer-in-Charge. |
| 44 | Supply & Filling of Coolent Antifreeze Capacity for radiators of 20 KVA to 250 KVA capacity DG set complete all as specified and directed (should be packed of 20 ltrs bucket Greaves completeall as specified and directed by Engineer-in-Charge.Cool)( Make:- Fleet Guard /Volvolane / Greaves |
| 45 | Supply and filling in Diesel Exhaust Fluid (D.E.F) compatible with existing DG Set completeall as specified and directed by Engineer-in-Charge. Make:Greaves/Kirloskar/Uricant |
| 46 | Repair/Attending break down of DG setto make completely functional in all respect to without replacing spare parts completeall as specified and directed by Engineer-in-Charge. Note:- The Item include any type of breakdown and sundry item cost deemed to be include in the quoted rate. |
| 47 | Note: The work under subject BoQ (item No. 1 to 30 ) is meant for maint and repair of DG Set in AF Stn Thoise/ Siachenunder GE(AF ) Thoise. The work shall be executed on ground on required basis but being remote station and extreme weather condition contractor must keep all essential spares ready as directed byEngineer to rectify the breakdown of DG Set.Contractor shall deploy sufficient resources to keep smooth working of DG Set in the AF station.In addition any breakdown shall be communicated to contractor or his representative by concerned Engineer-in-charge/JE E/M through phone call, text message, complaint slip and or in writing through site order book or through other means. Non complying of attending breakdown by contractor within 24 hours after notify the complaint, recovery @ Rs 2000/- per day shall be recovered from contractor\"s payment for each breakdown so notified. |