| 1 | Excavating in trenches, n exc 1.5 m wide, or n exc 10 sq m on plan, depth exc 1.5 m but n exc 3.0 mfor foundation, etc. or for laying of cables, poles , pipes etc. and getting out in soft/loosesoil complete all as specified and directed.Note :- Entire excavation shall be carried out manually only. No machinery such asJCB / excavator shall be used for excavation to avoid damage of existing electric supply / water supply / signal assets. This aspect shall be noted while quoting the Bid. |
| 2 | Excavating in trenches not exceeding 1.5 metre wide, exceeding 1.50 m but not exceeding3.00 metre in depthand getting out in hard/dense soil all as specified and directed.Entire excavation shall be carried outmanually only and not through excavator/JCB to avoid damage of existing electric supply/water supply/signal assets. This aspect may be noted while quoting the bid. |
| 3 | Returning, filling inincludingspreading, levelling, wateringandwellramminginlayersnotexceeding25 cms complete allasspecifiedanddirected. |
| 4 | Removal of surplus soil not exceed to a distance of 50M where directed at a level not exc . 1.5M above the starting point |
| 5 | Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty,galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 10 sqmm 4 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable glandjoint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed. Note : Earth works, sand cushioning,bricks,GI pipes etc will be measured and paid under respective items. |
| 6 | M&L for laying of DWC pipe inner dia 120 mm and outer dia 103 mm comfirming toIS 16205 for protection of LT UG cable of size 25 sqmm all as specified and directed by Engr-in-charge |
| 7 | S&F intrench/on wall in repairs GItubing light grade 50 mm dia for road crossing and cable protection etc complete all as specified and directed by Engr In Charge. |
| 8 | S&F steel tubularswaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410-SP-31 (9.0 metres long) and shifting of conductors and insulators etc including painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and interally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer including marking of pole number with black paint in yellow circle complete all as specified and directed.(Note:- Necessary earth work, PCCcoping will be measured and paid for separately under respective items.) |
| 9 | S&F LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make : Havells /Crompton/Philips |
| 10 | S&F street light junction box made up of 3 mm thick CRCA Sheet steel enclosure front openable including MS Fixing clamps made up of 32 x 6 mm MS flat duly painted, GI nuts, bolts and washers of suitable size and the size of junction box shall not be less than 30 cm x 27 cmx 15 cm having200 Amps rated aluminium bus bar of length not less 15 cm longfor 3 phase 4 wire system mounted on Porcelain/epoxy insulators and provn of one MCB SP 2.5 to 6.0 Amps with locking arrangement complete all as specified and directed. |
| 11 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for foundation of pole complete all as specified and as directed |
| 12 | M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate including use and waste of form work for pole coping/ any description all as directed. |
| 13 | Earthing complete with galvanizedsteel pipe electrode size 40 mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 metre below normal ground level with top edge of the earth plate not less 1.5 metre below normal ground level connectedwith and including GI strip of size 32x 6 MM by means of bolts and nutscheck nut and washer of galvanized iron with & including PCC pit in PCC 1:2:4 type B-1, precast RCC cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 7.5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point, and testing on completion including taking down old unsv earthing, complete all as specified and directed. Note :- (i) RCC pit cover shall becast of RCC (1:2::4) type B , 80 mm thick reinforcement with 8 mm TOR steel @ 100 c/c in lie if CI cover and the rate includes in the unit rate . (ii) Earth electrode shall be protected upto test point using necessary arrangement with suitable size GI pipe and the rate includes in the unit rate.(iii) Earth pit Cover shall be painted in Red paint over a primer and the rate included in the unit rate. |
| 14 | M&L for sub main wiring with 3 core PVC insulated stranded copper conductor 2.5 sqmm served with an inner sheathing of PVC tape, 1100voltsgrade heavy dutycabledrawn through and including PVC rigid Conduit and fixed on wall /poles etc and connected to light fittings all as specified.Note : One runs of 3 Core PVC cable 2.5 sqmm & one run of PVC conduit will be considered as one unit. |
| 15 | S&FLT Street Light Control panel board, Outdoor type,double door, cubical type, padestal mounted, overall size not less than 600 x 450 x 250 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3 mm thick CRCA sheetsuitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with 99 % copper bus bar of200 Amp rating for 3 phase and neutral,4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Setincluding necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar ofGI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coatingin siemens grey colour and supply and fixing the following incoming and out going accessories all as approved andcomprising as under : Incoming :- (a)MCCB 4 Pole, Micro processor release, breaking capacity 36 kA at 415V, 50Hz,63 Amp415V (Make : L & T Cat No CM92153OOOOX1 or equivalentin Legrand/Schneider) - 01 No. (b) Indicator Lamps (LED type) showing R,Y, B phase - 01 set. Outgoing :- (a) 3 pole street light power contactor with astronomical timer relay 24 hrs, fuses, complete suitable for 32A capacity - 01 No including necessary O/L, SPP & S/C protection relay complete for street light connection .(b) Angle iron base frame of required size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legsand made out of ISA50 x 50 x 6 mm thick angle iron duly painted - 01 No. |
| 16 | M&L GI Pipe Bracket made out of Galvanised Iron Tubing 40mm bre (dia), medium grade, 1.20 Metre long bent to shape as per specified for fixing Sreet Light fitting including suitable size of clamps and applying two coats of Aluminium Paint over a coat of Aluminium Primer complete all as specified and as directed. |
| 17 | Supply, installation, fixing and commissioning ofAdjustable type Inverter AC, 2 Ton, 5 Star - 245 Volts Vectra Elegant split type air conditionerof Cooling Capacity2 TR)BEE & minimum 4 star rated, multi adjustable mode, High ambient cooling, supper dry, turbo cooling , Anti Microbial air filter, Eco friendly refrigent, 100 % copper, wide voltage range operation,with cordless remote control unit Cooling Arrengement and,suitable for wall mounted single phase 230/250 volt AC including breaking necessaryfor fixing indoor and outdoor unit on stand and making good to distrubed surfaces with cement morter to match with existing colour after commissioning, making connection between indoor and outdoor unit with copper tubing with proper insulation and makingnecessary connection unplasticised PVC pipe medium duty 20 mm dia for draining out condensed water all as required including necessary connection complete. Note:- (i) Rate to be included cost of bracket, drain pipe, hole in brick wall etc.(ii) Cost of copper tubing for indoor and out door unit deemed shall be including quoted rate as per O.M. Make: Hitachi / Blue Strar / Voltas / L.G |
| 18 | Note :- Air Conditioning Unit shall have following technical specification :-(a) Model Type Voltas 185 V Vectra Elegant (b) Voltage range :- AC shall operate on voltage range from 110 V to 285 Volts (c)Min Coolong capacity - 2425 W(d) Max Cooling capacity - 5300 W(e) Rated Cooling capacity 100 % - 4850 W(f) Electricity Consumtion (Annual Based on 1600 Hours BEE Norms ) - 751.21 KWH/Year(g) Nos of fan speed - Auto/turbo/High/Med/Low (h) Fan Motor Type - BLDC(j) Expansion Device - EVV(k) Valve Size - 12.7 mm/6.35 Gas/Liquid (l) Refrigerant - R-32(m) ODU Dimension (wxhxd) - 83.5 X55.5X29.5 CM(n)Compressor Type - High EER Twin Rotary - BLDC (o) copper pipe - 3.5 Mtr (p) ODU code - 4513350(q) IDU code - 4553290 |
| 19 | S&F Voltage Stabilizer for automatic operation , single phase naturally air cooled indoor type & designed for input variation between 90 V to 300 V with output voltage stabilized at 230V with accuracy of +/- 2.5% and of capacity 4 KVA Make :- Voltas Cat NO. VA4090 - 4 KVA-90V-300V or Eqvilent make of V-Guard / LG |
| 20 | S&F Sheet metal enclosure for distribution boards double door, suitable for fixing MCBs 240 volts with 200 Ampsrated bus bar, SPN, 8 ways, supplied and fixed including making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge.Make ABB/Legrand/C&S |
| 21 | S&F Sheet metal enclosure for distribution boards single door, suitable for fixing MCBs 240 volts with 200 Ampsrated bus bar, SPN, 2 ways, supplied and fixed including making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge.Make ABB/Legrand/C&S |
| 22 | MCB suitable for 6 to 32 Amps, 240 Volt AC supply single pole and neutral with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge.Make ABB/Legrand/C&S |
| 23 | S&F 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. Make ABB/Legrand/C&S |
| 24 | M&L for submain wiringwith 2 runs of4.0 Sqmm (nominal area) size main cable & 1 runs of 4.0 Sqmm size earth continuity conductor single core PVC insulated unsheathed FRLSH multistranded copper conductor 1100 volt grade ISI marked cable drawn through & including suitable size of heavy duty non metalic rigid PVC concealed conduit ISI marked & conduit fittings/accessories, fixede concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified & directed.Note :-(i) 02 runs of 4.0 Sqmm size main cable, 01 run of 4.0 Sqmm size earth continuity conductor cable & Conduit with accessories shall be measured as one run length for payment purpose.(ii) Cost of cutting/leaving forming chases for conduits and making goodin CM 1:4 shall be included in quoted rate of this item. |
| 25 | S&F Electric chimney with FRP housing,toughened glass front panel ,baffle filter,push button control,energy efficient motor with top having size 900 mm,air flow 1350 Cum/hr,life time warranty complete with hanging/fixing accessories including chimney exhaust pipe extended upto 12 feet with cowl cover including fixing clamps and accessories complete all as specified & directed by Engr-in-charge.Make : FABER Model : ZENITH FL SC AC BKor Equivalent Make/Model in KAFF CASTO/Glen Model/Crompton/HindwareSpecifications :(i) Wall Mounted Chimney(ii) Chimney size : 900 mm(iii) Air Suction Capacity : 1350 CMH(iv) Product Weight - 13.5 Kg(v) Dimension of Product : 89.9 cm x 36.9 cm x 97.9 cm(vi) On device control type : Touch Control(vii) On Device control :Gesture Sensor Touch control(viii) Power Consumption : 250 Watts(ix) Voltage Rating : 220 Volt(x) Frequency : 50 Hz |
| 26 | M&L for point wiring for power point controlled by one way switch with 2.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) including 2.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) as continues earth wire in green colourto coomon earth dolly laid/drawn into and includingnon metalic PVC concealed conduit (medium duty, ISI marked not less than 20 mm dia) with all fittings such as tee, bends etc all as per IS terminated in& including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular Switches, sockets, regulators etc with and including modular cover plates with frame of requisite modules all as specified and as directed:Notes:- (i) Cost of cutting/leaving forming chases for conduit, sinking for metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed for include for modular metal flush boxes of requisite module and modular cover plate with frame of requisite module of colour as approved by GE |
| 27 | One multi pin socket 15/16Amps,Independent. |
| 28 | S&F switch Modular type, 16 Amp, 1 module single pole one way, 230 Volts, Modulartype complete all as specified and as directed by Engr- in -charge. |
| 29 | M&L socket outlet 3 Pin6/16 Amps modular type, 2/3 pin combined 2 module230 Voltscomplete all as specified and directed by Engr-in-Charge. |
| 30 | S&F sheet metal enclosures with socket,plug top complete with one single pole MCB -240 Volt- 20 AMP complete all as specified and as dircted by Engr-in-charge.Note : For AC Point. |
| 31 | S&F Ice making machine of capacity 90 Ltrs ,Self standing ,made out of Stainless Steel Body , Air Cooled with Eco Friendly Refrigerant R-404A working on Single Phase Power Supply 43 Kgs/24 hrs rated capacity and 25 Kgs Ice Storage Bin complete all as specified and as directed as per Engineer-in-charge. |