| 1 | Supplying and fixing following way, single pole and neutral,sheet steel,MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator)( a )16 way, Double door |
| 2 | Supplying and fixing following rating doublepole 240 V isolator in the existing MCBDB complete with connections, testing and commissioning etc as reqd. (a)40 Amp |
| 3 | Replacement of 5 A to 32 A rating, 240/415 V, 10 kA, \"C\"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single pole |
| 4 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface medium class PVC conduit with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required( a ) Group C |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface recessed steel/PVC conduit as reqd. (a) 2x1.5 Sq mm |
| 6 | (b) 3x1.5 sq mm |
| 7 | {c}4x1.5 sq mm |
| 8 | {c}6x1.5 sq mm |
| 9 | (a) 2x2.5 Sq mm |
| 10 | (b) 3x2.5 sq mm |
| 11 | {c}6x2.5 sq mm |
| 12 | (d) 3x6 Sqmm |
| 13 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(a) 20 mm dia |
| 14 | (b) 25 mm dia |
| 15 | Supply aqnd fixing following piano type switch / socket on the existing switch box / cover including connections etc as reqd.(a)5/6 amps switch |
| 16 | (b) 5 Amp 3pin Socket |
| 17 | © 15 Amp Switch |
| 18 | (d) 15 Amp 6pin Socket |
| 19 | Supply and Fixing of 400 mm sweep wallfan i/c connection, testing etc as reqd. |
| 20 | Providing and fixing 20 watt LED tube fitting i/c connection with 1.0 sq mm copper wire as reqd. |
| 21 | Supplying and fixing of switch box of Suitablesizes on surface or in recess with suitable size of phenolic laminated sheet cover in front etc. as required. |
| 22 | Supply and Fixing of 1200 mm sweep ceiling fan i/c connection, testing etc as reqd. |
| 23 | Supply and Fixing of electronic regulatorforceiling fan i/c connection, testing etc as reqd. |
| 24 | Dismantling and re-laying/fixing of various power cable from space to be vacated(Old Pkg room) to power room i/c proper saddling etc as reqd. |
| 25 | Replacementof 100 Amp 4 pole on load change over switch in sheet steel enclosure i/c connection, testing etc complete as reqd. (M/S HPL/Havells/S.s make) |
| 26 | Providing & installingglow sign board approx 4\" height & 25\" length with provision of insidelighting arrangement with LEDs & of suitable thickness acrylic sheetalongwith suitable MS angle iron/ MS square pipe framework for holding the compete assembly including necessary internal wiring etc complete as required. |
| 27 | Dismantaling of 2x1.5 TR split AC along with indoor andoutdoor units in PGM office1st floor and shifting to conference hall at 23rd floor with the help of labours/technician etc as required. |
| 28 | Servicing and ITC of 1.5 TR SAC unit in conference hall complete as reqd. |
| 29 | Providing copper refrigerant pipe of size 1/2\" & 1/4\" with insulation foam i/c brazing etc as reqd. |
| 30 | Charging of R-22 refrigerant gas in the SAC unit i/c leakage testing by nitrogen gas complete as reqd.. |
| 31 | Supply and Fixing of 3x2.5 sqmmround flexible copper cable i/c connection, testing etc as reqd. |
| 32 | SITC of public address system in the conference hall at second floor CTO building Gorakhpur with following configuration - 1 no chairman unit, 2 nos column speaker, 1 no 240 watt amplifier and necessary cabling etc complete as required. (Make :- Ahuja CMA 5400 or similar superior make). |