| 1 | SH-I (Air conditioning) |
| 2 | Supply , Installation, Testing and Comissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB).Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 deg C (out door ambient temperature).Inverter Type-hot & cold 1.5 TR with 3 star BEE rating |
| 3 | Supplying and fixing of good quality of Powder Coated MS frame setof MS Sheet to accomodate the condenser( Out door) unit for fixing on the wall with suitable diameter and length of Anchor fast bolts and making good etc as per site requirement. |
| 4 | SH-I (Air conditioning) |
| 5 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 6 | Group C |
| 7 | P/F following sizes of PVC casing and capping of superior qualityon surface complete i/c cutting finishing fixing on existing wall /partition etc complete as required. |
| 8 | 25mm |
| 9 | 38mm |
| 10 | P/F following sizes of PVC trunking of superior qualityon surface complete i/c cutting finishing fixing on existing wall /partition etc complete as required.(ISI mark) |
| 11 | 50 mm x 50 mm |
| 12 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. |
| 13 | 3 x 1.5 sqmm |
| 14 | 6 x 1.5 sqmm |
| 15 | 3 x 4 sqmm |
| 16 | 6 x 4 sqmm |
| 17 | 2 x 6 sqmm |
| 18 | 4 X 10 sqmm |
| 19 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. |
| 20 | 1 or 2 Module (75mmX75mm) |
| 21 | 3 Module (100mmX75mm) |
| 22 | 4 Module (125mmX75mm) |
| 23 | 6 Module (200mmX75mm) |
| 24 | 8 Module (125mmX125mm) |
| 25 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 26 | 5/6 amps switch |
| 27 | 15/16 amp switch |
| 28 | 3 pin 5/6 amp socket outlet |
| 29 | 6 pin 15/16 amp socket outlet |
| 30 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 31 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s (but without MCB\"s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 32 | 4 way (8 + 12), Double door |
| 33 | Supplying and fixing following rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 34 | Single pole |
| 35 | Four Pole63 Amp MCB |
| 36 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 37 | 63 amps |
| 38 | SITC of following type prewired surface / recess mounted (minimum colour code 840) LED light fixture & integrated electronic driver(wherever required) suitable to operate on 240 volts 50 HZ AC supply including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. (Preferred make Philips/ Wipro/ Havells/ Crompton/ Bajaj/ Osram/ Surya or Similar Superior Make) |
| 39 | 600mm x 600mm (Nominal dimension) 36 watts Surface Type Metallic CRCA Powder Coated Housing High efficiency Diffuser Cover having minimum lumen efficacy as 100 lumens/watt complete with accessories as required |
| 40 | Surface Type LED Round/SquarePanel / Downlighter 12/15 wattshaving minimum lumen efficacy as 100 lumens/watt with accessories etc. as required |
| 41 | Surface Type LED Batten 40 wattswith Exruded Aluminium housing Suitable for Wall & Conduit Mounting having minimum lumen efficacy as 100 lumens/watt with accessories as required |
| 42 | Extruded Aluminium 2 ftLEDBatton10/12 watt having minimum lumen efficacy as 100 lumens/watt with accessories as required |
| 43 | SITC of 1200 mm sweep energy saver ceiling fan including wiring the down rod of standard length (upto 30 cm)with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.(M/s Orient ES-49 or similar superior make, Other preferred makes Crompton Greaves/Usha /Khaitan /Bajaj/ Havells) |
| 44 | SITC of 250 mm sweep Ventilating fan with plastic body and louvers i/c connection with 2x1.5 sqmm cu. Conductor FR PVC cable etc as required at site. (M/s HAVELLSmodel Venti Air-DX White or similar superior make, Other preferred makes Crompton Greaves/Usha/ Khaitan/Bajaj/Orient) |
| 45 | SITC of 200 mm sweep Ventilating fan with plastic body and louvers i/c connection with 2x1.5 sqmm cu. Conductor FR PVC cable etc as required at site. (M/s HAVELLSmodel Venti Air-DX White or similar superior make, Other preferred makes Crompton Greaves/Usha/ Khaitan/Bajaj/Orient) |