| 1 | M&L for surface excavation over Hard/ dense soiln.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft soil complete all as specified and as directed. |
| 2 | M&L for excavating in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation etc and gettiong out in hard/dense soil complete all as specified and directed. |
| 3 | M&L for excavating in trenches n exc 1.5m wide andexc 1.5m and n exc 3.00m in depth for foundation etc and gettiong out in hard/dense soil complete all as specified and directed. |
| 4 | M&L Plain cement concrete 1:4:8 mix, Type D2 (using 40 mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and as directed. |
| 5 | M&L for RCC M-30 (Design mix)using 20 mm graded aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 6 | M&L for formworkin rough finished surface of concrete to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 7 | S&F TMT steel bars 10mm dia and over as reinforcement cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed. |
| 8 | M&L for TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups spaces and binder cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed. |
| 9 | M&L returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in hard/dense soil complete all as specified and directed. |
| 10 | M&L for removing excavated material of soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 11 | S&F in Mild Steel Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections etc of Fe-410-W (Gde-E-250) quality-Bcomplete all as specified and as directed. |
| 12 | M&L for MS Plates (plain or chequered) channels,square cut or notched (ordinary and counter sunk) forming holes, without any attachment incl fabrication, Fe-410-W (Gde-E-250) quality-B, complete all as specified and directed. |
| 13 | S&F for Mild Steel dia neck in 20mm rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised,exc 30cm long, complete all as specified and directed. |
| 14 | S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 15 | S&F in repair Mild Steel Rolled sections as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces of Fe 410-W (Gde E- 250) quality A , cleats etccomplete all as specified and as directed. |
| 16 | M & L Preparing new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 17 | M&L for Reinforced cement concrete (nominal mix) Type B0 1:2:4(12.5mm gradedaggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 18 | M&L for Non -skid cermaic coloured Heavy duty tiles of size 400X400X12mm thick, out door tilesin each floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 19 | S&F for 1.2 mm thick Galvalnised steel manufactured from hot dipped zinc coated high strength steel with 550 Mpa min yield strength and coating mass of Z275 (min 275 g/m2 total of zinc coating on both sides) with 12.33 kg/m2 min self weight for floor slab in ramp complete all as specified and as directed. |
| 20 | S&F forPre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as manufacturers instruction and as directed. |
| 21 | S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa asin ridges, hips, valley gutter, drip, and straight flashing, roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 22 | S & F Aluminium flat , wind ties of any size fixed with self tapping screws of size 40/50mm with integral EPDM washer screwed in roof covering, including all necessary drilling, bolting or riveting etc., and similar work complete all as specified and as directed. |
| 23 | S&F for aluminium anodised snap grid false ceiling of standard aluminium section such as wall angle of size 38mm x 25mm x 2.4mm weighing 0.36 Kg/Rm main/cross tees of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/Rm, grid size n.exc. 610 x 610mm suspended with 4mm dia GI wire at interval n.exc. 600mm centre to centre for main & cross tees fixed to roof slab roof truss fixed with suitable size MS hook and fastening bolts etc including \"E\" board classic 4mm thick oceanic sheet of size n.exc. 610 x 610mm size fixed in ceiling with clips to aluminium snap grid complete all as specified and as directed. |
| 24 | S&F 605 X 605mm grid hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of celing cleats made out of GI flat 40 x 3mm size 60mm long complete all as specified and as directed. |
| 25 | M&L for precast cement concrete block masonary with solid blocks type C1 1:3:6 using 20mm graded aggregate exc 10cm in width and setting in cement mortar 1:6 complete all as specified and as directed. |
| 26 | M&L forrendering 15mm thick plaster in CM (1:6) on brick/blockor concrete surfacesfinished even & smooth complete all as specified and as directed. |
| 27 | M&L forrendering 5mm thick plaster in CM (1:4) over a backing coatof 10 mm thick inCM 1:6 (Total15 mm thick ) on concreteor block masonry surfacesincluding mixing water proofing compound on top layeras per manufactures instructions(or 3%by weight of cement)and finishing the top surfaces even and fair completeall as specifiedand as directed.Note :Water proofing compound shall be measured and paid seperately under relevant item of this schedule as supply only. |
| 28 | Supply only water proofing compound ISI marked completeall as specified and as directed.( Note : WPC may apply as per manufactures instruction or 3% by thewt of cement) complete all as specified and as directed. |
| 29 | M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed. |
| 30 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 31 | S&F for power coated aluminium frame for doors, windows ventilators and partition with one or more rebates including joining cleat for fixing etc complete all as specified and as directed. |
| 32 | S&F for powder coated aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing, clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and as directed. |
| 33 | S&F for powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No) hinge type B-21 100mm long (2 No) suitable handle (1 No) complete all as specified and as directed. |
| 34 | S&F for Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed. |
| 35 | Supply only5.5mm thick sheet glass ordinary quality, in squares n. exc 0.5sqm each pane complete all as specified and as directed. |
| 36 | M&L for excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in & raming earth/ broken rubble mixed with earth around, in layers n. exc. 25cm, watering, & removing surplus soil to a distance n exc 50m & making good surface in soft/loose soil complete all as specified and as directed. |
| 37 | S&F MS framed work such as fencing post including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 38 | M&L PVC coated GI chain link fencing 3.5mm dia with 50mm x 50mm mesh including fixing of MS line wire / rod, flat iron & machine made hexagonal or square head bolts to fencing posts complete all as specified and as directed.(Note : MS rod,and MS bolts will be measured and paid seperately as supplied only) |
| 39 | Supply only mild steel screw bolts n exc 12 mm dia machine made with hexagonal or square head at one end and screwed the other or screwed both ends for fixing of chain link fencing complete all as specified and as directed. |
| 40 | Supply only 10 mm dia Roundbarsfor support to chain link fencing confirming to Fe-290 (Gde E-165) complete all as specified and as directed. |
| 41 | M&L for preparing new steel or iron surfaces of any description n exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 42 | M&L for excavating over areas, n exc 1.5 m deep and getting out in Soft/loose Soil complete all as specified and as directed. |
| 43 | M & L for 100 mm thick plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as sub base of flooring complete all as specified and as directed. |
| 44 | Supply and laying premium grade, heavy duty, anti skid floor tiles of approved make in size 400 x 400mm.The tiles shall have a minimum thickness of 10mm, set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floor over and including 20mm thick screed bed in CM (1:4) etc., complete all as specified and as directed.The tiles must conform to IS 15622 and IS 4457 standards. |
| 45 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & site / shape, made by table vibratory method using PU mould, laid in required colour & pattern over and icnludign 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 46 | M&L forPCC (1:2:4)type B1 using 20 mm stone graded aggregate as in coping at sides of paver blocks all as specified and directed. |
| 47 | Taking down & relaying of serviciable cable ofXLPE/ PVCinsulated electric power cable laid in trenches / duct with shaddling/ on pole including all necessary fixing arrangement such as lugs, glands end termination etc of following sizes complete all as specified and as directed by Engineer-in-Charge.Note:(i) Excavation earth work, replacement of unserviceable DWC pipe & end joint kits shall be measured and paid seperately.(ii) The quoted rate deemed to be inclusive of necessary clamping arrangement if laid on wall and termination of cables. |
| 48 | (a) 3.5/4 core 10 Sqmm to 35 Sqmm |
| 49 | (b) 3.5 core 50 Sqmm to 95 Sqmm |
| 50 | (c) 3.5 core 120 Sqmm to 240 Sqmm |
| 51 | Suppy and laying in trenches / fixed on walls / passing through pipes, jointing and testing of electric LT cables, XLPE insulated, PVC sheathed, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 Volts grade complete all as specified and as directed by Engineer-in-Chargefor the following size :-Note:(i) The rates shall be inclusive of Cable lugs at both ends of cable and end termination kits will be measured and paid seperately.(ii) Excavation earth, return and re filling shall be measured and paid seperately.(iii) Joint kit if required shall be measured and paid seperately. |
| 52 | (a) 4 Core 16 Sqmm |
| 53 | (b) 3.5 Core 25 Sqmm |
| 54 | (c) 3.5 Core 70 Sqmm |
| 55 | (d) 3.5 Core 120 Sqmm |
| 56 | (e) 3.5 Core 185 Sqmm |
| 57 | M & L for shifting of existing LT panel by disconnection of incomer and outgoing cables from LT panel securely, dismantling PCC foundation and shifting to new location with in 50 mtr radius as directed with PCC foundation and necessary grouting arrangement for fixing of LT panel in new location, connecting all disconnected cablesafter relaying and preparation to internal and external old steel surface of LT Panel Board completely removal of existing treatment by scraping or chemical and surface painted with two coats of synthetic enamel paint of approved colour and decrabonizing of LT panel bus bar with CTC solution complete all as specified and as directed.Note:(i) Relaying of cable and end termination work shall be measured and paid seperately.(ii) The quoted rate deemed to be inclusive of painting of panel, PCC foundation and necessary nut bolts for grouting arrangement. |
| 58 | Supply & Laying of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of following sizes, made up of polythylene including coupler & Bend with smoooth inernal and corrugated external surface for non pressue under ground cable complete all as specified and as directed. |
| 59 | (a) 40 mm |
| 60 | (b) 50 mm |
| 61 | (c) 77 mm |
| 62 | Excavation in trenches any type of soil (soft/loose/hard/dense) not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, pipe, laying of cable etc not exc 10 Sqmtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and as directed by Engineer-in-Charge |
| 63 | S & F for cable jointing kit for 1100Voltgrade cable for Straight through, heat shrinkabletype joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 10 to 16 Sqmm 3.5 core/ 4 core complete all as specified and as directed by Engineer-in -charge. |
| 64 | S & F for cable jointing kit for 1100Voltgrade cable for Straight through, heat shrinkabletype joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm 3.5 core complete all as specified and as directed by Engineer-in -charge. |
| 65 | S & F for cable jointing kit for 1100Voltgrade cable for Straight through, heat shrinkabletype joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 70 to 150Sqmm 3.5 core complete all as specified and as directed by Engineer-in -charge. |
| 66 | S & F for cable jointing kit for 1100Voltgrade cable for Straight through, heat shrinkabletype joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 185 to 240 Sqmm 3.5 Core complete all as specified and as directed by Engineer-in -charge. |
| 67 | S & F for cable jointing kit for 1100 Voltgrade cable for indoor / outdoor end termination joint kit, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 10 to 16 Sqmm 3.5 core as in repairs complete all as specified and as directed by Engineer-in -charge. |
| 68 | S & F as in repair for cable jointing kit for 1100Voltgrade cable for indoor / outdoor end termination joint kit, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm 3.5 core as in repairs complete all as specified and as directed by Engineer-in -charge. |
| 69 | S & F as in repair or cable jointing kit for 1100Voltgrade cable for indoor / outdoor end termination joint kit, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 70 to 120Sqmm 3.5 core as in repairs complete all as specified and as directed by Engineer-in -charge. |
| 70 | S & F as in repair for cable jointing kit for 1100Voltgrade cable for indoor / outdoor end termination joint kit, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 150 to 185 Sqmm 3.5 Core as in repairs complete all as specified and as directed by Engineer-in -charge. |
| 71 | M&L for dismantling of existing unserviceable steel tubular poles of any size including taking down light fitting securely complete all asspecified and as directed. |
| 72 | M&L for erection of GI Octgonal pole complete with GI base plate finial taper plug, bolts, nuts and screws with suitable bracketall as specifiedof height9 M including necessaryearth work, RCC foundation, copping etc and refixing of all existing fitting fixture retrieved from existing old electric pole complete all as specified and as directed. |
| 73 | M.&L for earthing complete with Galvanized -seel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mir deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 32x6mm connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 40 mm dia GI pipe light grade for protection of GI strip and 20mm dia GI pipe light grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I and testing and dismantling old earthing complete all as specified and as directed by Engineer-in -charge.Note: (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item(ii) The unit rate shall also includes for Wire mesh, funnel, excavation.returninng & filling. PCC chamber pit, RCC cover & test point. |