| 1 | M&L for demolition of Reinforced Cement Concrete [reinforcement cut as required to facilitate demolition] of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 2 | M&L for excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 3 | M&L returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 4 | M&L for removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 5 | M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams, and similar work for rough finished flat surfaces complete all as specified and as directed. |
| 6 | M&L for Formwork to sides of pillars, posts, struts, piers, columns, and coping beam stanchions complete all as specified and as directed. |
| 7 | M&L for Form work in lintel beams, roof beams and bend of rough finished concrete surfaces complete all as specified and directed. |
| 8 | M&L for Plain Cement concrete typeC2 1:3:6 (using 40 mm graded stone aggregate) in foundations,filling and mass concrete complete all as specified and as directed. |
| 9 | M&L RCC M30 grade (Design Mix) using 20mm graded stone aggregate as infoundations including rafts, footings, foundation beams, plinth beams; bases for coloumns, etc basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 10 | M&L RCC M30 grade (Design Mix) using 20mm graded stone aggregate as incolumns, pillars, piers, post and struts etc complete all as specified and as directed. |
| 11 | M&L RCC M30 grade (Design Mix) using 20mm graded stone aggregate as in beams, cantilevers, bressummers, coping, lintel beam,bend etc complete all as specified and as directed. |
| 12 | M&L for TMT bars 10mm dia and over cut to length, bent to shape required incl cranking, bending, spirally for hooping for columns, hooking end and binding with and incl mild steel wire not less than 0.9mm dia or securing with clip quality confirming to TMT bars complete all as specified and directed. |
| 13 | M&L for plain cement concrete type B1 (1:2:4) using 20mm graded stone aggregate as in copings cavings, bed plats and embeding swan neck fencing post, etc incl weathering slightly rounded or chamfered angles and throating as directed complete all as specified and directed. |
| 14 | M&L for demolition of precast concrete block walling built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed. |
| 15 | M&L precast cement concrete block masonry with solid block, exc 10cm in width in PCCtype C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:4) all as specified. |
| 16 | Taking down cement plaster on brick or stone wall and racking out joints hacking for key sucrubing down with water etc complete all as specified and as directed. |
| 17 | M & L for rendering 5 mm thick in cement mortar 1:4 over a backing coat of 10mm thick in CM 1:6 (Total 15 mm thick) on concrete or brick masonry surfaces and finishing the top surface even and fair without using extra cement complete all as specified and as directed. |
| 18 | M & L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new plastered surfaces complete all as specified and as directed. |
| 19 | M & L for complete removal of existing treatment and Preparation ofplasteredwall surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and as directed. |
| 20 | M&L for dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 21 | M&L for MS work incl embedding in concrete and screwing bolts, posts and struts in fencing including cutting tops to shape as directed drilling holes notching for wire etc flat iron fillets (for securing wire mesh etc incl all necessary drilling, bolting or rivetting, etc and similar work conforming to Fe-290-Gde E-165 complete all as specified and directed. |
| 22 | M&Lin repairs for galvanised, 2 strand steel barbed wire 2mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of stranded rails straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, staple or steel pins etc as directed each line wire to be measures complete all as specified and as directed. |
| 23 | Supply and fix puched tape concertia coil of 610 mm, openable/ stretchabe to 6.00 mtr round type, 51 spirals core wire made out of 2.5 mm high tensile steel wire galvanised with with tensile 1500 Mpa as specified in IS - 4454 including necessary wire for fixing coil on security compound wall to Y shaped MS angle complete all as specified and as directed. |
| 24 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering. Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing Fe 410-W(Gde-250) qualit\" \"A\" Grade complete all as specified and as directed. |
| 25 | M&L for preparation of new steel surfaces over 10cm width or grith and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 26 | M&L for preparation of old painted steel surfaces over 10cm width or grith and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |