| 1 | Excavation in trenches,n exc 1.5 m wide and n exc 1.5 m in depth; for foundation laying of cables ,etc or for shafts,wells,cesspits,manholes,pier holes,etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/lose soil complete all as specified and directed. |
| 2 | Returning, filling in including spreading,levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil under floor complete all as specified and directed. |
| 3 | Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 4 | Material and labour for clean dry sand in trenches/ducts for cushioing to cable protection complete all as specified and directed. |
| 5 | Supply and laying common burnt clay building bricks, sub-class ‘B’ designation 75 complete all as specified and as directed. |
| 6 | Taking out old cable cover (Bricks) of any sizefrom any location , keeping in safe custody and relaying with same brick for using cable cover protection of any location complete all as specified and directed. |
| 7 | Taking down old unserviceable, undergroundcable of any sizefrom any locationcomplete all as specified and directed. |
| 8 | Supply and fixing galvanised iron tubing 40 mm bore, light grade with all fittings & fixture as in cable protection laid in trenches/floor or on the Pole etc. complete all as specified and directed. |
| 9 | Supply and fix in repair XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volt grade, cross sectional area 70 Sqmm 3.5 core . |
| 10 | Supply and fix in repair XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volt grade, cross sectional area 25 Sqmm 4 core. |
| 11 | Supply and fix in repair XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volt grade, cross sectional area 16 Sqmm 4 core . |
| 12 | Supply and fix in repair XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volt grade, cross sectional area 10 Sqmm 2 core. |
| 13 | M&L in repair straight through joint, heat shrinkable type suitable for LT under ground cable of size 16 sqmm to 25 sqmm, 3.5/4 core complete all as specified and directed. |
| 14 | Supply and fix in repair 70 watt LED street light fitting made up of pressure die cast aluminum housing with toughened glass and high powered individual LEDs with secondary optics, constant current driver with in built protection against lightning ,over voltage & short circuit, IP66 Protection andfixing on 40 mm dia of bracket complete all as specified and directed. |
| 15 | Supply and fix in repair 45 watt LED street light fitting made up of pressure die cast aluminum housing with toughened glass and high powered individual LEDs with secondary optics, constant current driver with in built protection against lightning ,over voltage & short circuit, IP66 Protection andfixing on 40 mm dia of bracket complete all as specified and directed. |
| 16 | Supply and fix in repair 120 watt LED flood light fitting made up of pressure die cast aluminum housing with toughened glass and high powered individual LEDs with secondary optics, constant current driver with in built protection against lightning ,over voltage & short circuit, IP66 Protection complete all as specified and directed. |
| 17 | Supply and fix in repair Power contactors MNX 100 Amp coil voltage 230V AC complete all as directed by Engr-in-charge. |
| 18 | Supply and fix in repair \"C\" series TPN MCB 63 Amp, 10 KA all as specified & directed. |
| 19 | Taking down high mast light of size 12/15/16 mtrfrom its base wih help of crane , cleaning, greasing and overhauling of all movavable parts like pullies, steel wire, chain ,winches etc, replace unserviceble light if required ,and refix the mast on its original positioncomplete all as specified and directed by Engineer-in-Charge.Note: -(i)Including chareges- Labour charges, crane charges , graesing and overhaling.(ii)Excluding charges- Serviceable flood light. |
| 20 | Rewinding of three phase electric motor 1.5 HP for highmast system of suitable size complete all as directed. (with copper wire) Note :- Cost of copper binding wire is included in quoted rate. |
| 21 | M&L for cleaning the swaged steel tubural street light poles 9meters height including GI pipe of street light fitting and prepare surfaces cleaningincluding scrapping up of old corroded paint dirt/dust/ rust carefully and applying two coat of aluminium paint over one coat of metal primer and marking of zebra crossings up to a height of 1.0m above the coping with black andyellow strips of synthetic enamel paint including writing of pole numbers and two coats colour washing of PCC coping complete all as specified and directed by Engineer-in-Charge. |
| 22 | Same as item No. 21 but the swaged steel tubural street light poles 11 meters height complete all as specified and directed by Engineer-in-Charge. |
| 23 | Supply and fix in repair earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. |
| 24 | Supply and fix in repair PVC insulated, unsheathed 1.5 sqmm 3 core industrial copper cablee for 230 Voltage complete. Make Polycab/Havells/KEI |
| 25 | Taking down unsv light fitting from 9/11 mtr electric pole and S&F Drivers for LED street lights 45W/60/70W, 230 Volts, 50 HZ existing make and after replace unsv driver with new refix again existing place complete all as directed and specified by Engr-in-charge. |
| 26 | Taking down unsv light fitting from 9/11 mtr electric pole and S&F Drivers for LED Flood lights 100W/120W, 230 Volts, 50 HZ existing make and after replace unsv driver with new refix again existing placecomplete all as directed and specified by Engr-in-charge. |
| 27 | Supply and replace aluminium lugs suitable for 25 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed.Make : Sona cable sockets / swastic /dowells |
| 28 | - ditto -above but for 16 Sqmm Sqmm, Make : Sona cable sockets / swastic / Dowells |
| 29 | Takingdown old unsv solar light fittings from pole of any size and replacement of unsv lithium Ion battery 12Ah to 24 AH with new battery for existing make or capacity for functionng light and refix in same place and check to serviceable light fittinig to Engr in charge for his entire satisfication as specified and as directed. |
| 30 | Supply and fix in replacement energy efficient, environmently friendly, long life aesthetically designed LED garden light with pressure die cast powder coated housing with PC diffuser,IP-65/66 protection, high output LED 8/10 W as light source with FRP junction box forconnection of lightcomplete all as specified and as directed. |
| 31 | Cutting of bituminous/PCC/PQC road for laying of pipe line notexceeding 1.5 m depth/ width including making good to disturbed portion to match with the existing road / path with PCC. |
| 32 | S & F in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor twin core cable flat or circular of size 6.0 sqmm complete. |
| 33 | Material & Labour for PCC 1:3:6 type C2 using 40mm graded aggregate as in copping/collar of garden light poles and foundation etc complete all as specified and directed. |
| 34 | Supply and fix HOT moulded (FRP) jucntion box for street light pole with locking arrangementt with IP -65 protection of size 200x150x100 with 32 Amp 4 way heavy duty terminal block withtwo steel bracket to fix with pole and aluminium bus bar of rating 200Amps completeall as specified and directed by Engr - in - charge. |