| Sl. No. | Item Description |
| 1 | Sch \"A\" Part -I (B/R work) |
| 2 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground, posts embedded in natural ground complete all as specified and directed. |
| 3 | Dismantling old chain link fencing wire mesh, any type complete all as specified and directed. |
| 4 | Dismantling wrought iron or mild steel work of any description and removal from site complete all as specified and directed. |
| 5 | Dismantling old GI wireany type complete all as specified and directed. |
| 6 | Excavating in post holes in soft/loose soil each n exc 0.5 cum, getting out, and returning filling in and ramming with concrete around, and removing surplus soil to a distance n exc 50 m complete all as specified and directed. |
| 7 | M&L PCC (1:3:6) type C-2 using 40 mm grade stone aggregate as in foundation, filling and mass concrete all as specified and directed. |
| 8 | M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in coping and around MS post above GL and wall of trough including necessary form work complete all as specified and directed. |
| 9 | M&L MS works as in Posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets for securing wire mesh etc) including all necessary drilling bolting or riveting etc and similar work confirming to Fe 290 Gde E-165, complete all as specified and directed. |
| 10 | Fixing only New/Old chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and directed. |
| 11 | Supply only chain link MS Galvanised fencing, any size or type complete all as specified & as directed. |
| 12 | S&F Mild & steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n.exc. 5 cm and 5 to 10 mm dia complete all as specified & as directed. |
| 13 | M&L MS round bars 10 mm dia as in stiffener for straightening chain link fencing complete all as specified and directed |
| 14 | S&F in repair Galvanised 2 strand steel barbed wire 2.24 mm barbed with 2 mm dia barbs @ 75 mm spacing straining and fixing including securing or lying at crossing with and provision of galvanised MS staples or steel pins incl dismentling of old barbed wire complete all specified and directed |
| 15 | M&L for Broken glass coping in cement mortaar (1:3) on top of walls complete all as specified and directed. |
| 16 | M&L preparation of new steel surfaces and applying two coat soft synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 17 | Demolition of brick/stone masonry, built in cement mortar including all quoins, arches, pillars etc but exluding ashlars facings, dressed stone work and pre-cast concrete articles all as directed. |
| 18 | M&L brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6 meter mean radius with old size bricks builtin CM 1:6,complete all as specified & as directed. |
| 19 | Taking down cement plaster any description on brick or stone walls/RCC walls surfaces etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified & as directed. |
| 20 | M&L Rendering 15 mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished fair and even complete all as specified and directed. |
| 21 | M&L Three coat of white wash on wall including preparation of new plastered surfaces all as specified and directed. |
| 22 | M&L for cleaning of blocked/ chockedpipe line of 100 mm dia from floor or gullytrap or from cleaning eyes, up to Ist manhole in any depth by rodding or by mechanical means and well flushing the complete line up to Ist man hole including removing of sludge/ waste to low lying areas within 200 m distance and burring the same properly to the entire satisfaction of Engineer- in- Charge, with and including taking out and re-fixing of manhole covers duly set in cement mortar 1:4 as and where required complete all as specified and directed.Note for item No. 22 to 26 : All blockages/complaints to be cleared within 24 Hrs. If any blockage is not cleared within 24 Hrs, a panelty of Rs 250/- per a/u shall be imposed to the cotractor for every day of delay. |
| 23 | Ditto all as above but of size 150mm dia |
| 24 | M&L for cleaning of blocked WC, Gully trap, Floor trap and Nahani trap incl cleaning branch piece from trap to connecting bend or junctioncomplete all as directed. |
| 25 | Taking off existing cover of septic tank, cesspool, soak well, soak pit or manhole and Cleaning of septic tank including connecting chamber by pumping out sludge water incl taking out mud sludges from tank to remove a distance exc 50 mtr and not exc 100 mtr, filled in the trenches not less than 01 mtr deep from ground level and incl refilling the trenches with excavated earth to cover sludges placed, all as directed by Engineer-in-charge. |
| 26 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for cesspit, manhole etc,and getting out in soft/loose soil even in foul position complete all as specified and directed. |
| 27 | Returning, filling in incl spreading leveling watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as directed. |
| 28 | Removing excavated material (Soil) n exc. 50m and depositing where directed at a level n exc 1.5 m above the starting point |
| 29 | Demolition and breaking up of existing drain pipe (SGSW/ PVC/ RCC etc) set in cement mortar of internal dia of pipe 150 mm complete all as directed. |
| 30 | M&L PCC (1:4:8) type D2 (using 40 mm graded aggregate) as in concrete bed to 150 mm bore drain pipe incl packing under hunching against the sides of pipes after pipe laid and tested complete all as specified and as directed. |
| 31 | M&L for150mm dia Reinforced concrete pipes, class NP2, laid and jointed completewith collars |
| 32 | M&L for 150 mm bore PVC (SWR) pipe laid in trenches and jointedwith cement mortar complete all as specified and as directed. |
| 33 | S&F in repair 75mm PVC (SWR) multi floor trap with grating including jointing with solvent cement and making the surface good complete all as specified and directed. |
| 34 | S&F in repair 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls as rain water pipe and similar work complete all as specified and directed. |
| 35 | Ditto all as above but of size 75mm |
| 36 | Demolition of reinforced cement concrete as in cover slabs of manhole or septic tank, soak pit all as complete all as specified & as directed. |
| 37 | M&L for RCC (1:2:4), type B1 (using 20mm graded aggregate) Precast cement concrete as in cover slab for man hole and similar article with plain face. Set in CM 1:4 complete all as specified & as directed. |
| 38 | S&F deformed or twisted TMT bar 6 mm to 8 mm diacut to length, bent to shape required, incl cranking bending and binding with MS wire (annealed) not less than 0.9mm or securing with clips complete all as specified & as directed. |
| 39 | M&L for non-skid ceramic tiles 7 to 8mm thick area of each tile exceeding 0.06 sqm but n.exc 0.11 sqm in floors etc including 15mm thick screed or bedding layer in cm 1:4 for laying floor finish, set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling of floor or wall tilling including cement mortor bedding (but not backing) removing serviceable tiles from site and rubbish off premises complete all as specified and directed |
| 40 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6 meter mean radius with old size bricks built in CM (1:4),complete all as specified & as directed. |
| 41 | M&L Rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces finished fair and even complete all as specified and directed by Engr-in-charge. |
| 42 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-charge. |
| 43 | M&L for PCC (1:2:4) type B-1 using 20 mm grade stone aggregate as in coping, weathering, slightly rounded or chamfered angles and throating, as directed including necessary form work complete all as specified and directed. |
| 44 | M&LPCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundations, filling, mass concrete and sub base of floor etccomplete all as specified and directed. |
| 45 | M&L PCC (1:2:4) type B-2 using 40 mm graded stone aggregate as in floor etc 100 mm thick finished even and fairlaid in alternate bays, with spike rolling to surfaces or making impression of expended metal whilst the concrete is green complete all as specified and directed. |
| 46 | M&L for precast machine pressed cement concrete interlocking paver blocks of any shape and size confirming to IS 15658-2006 of 60 mm thick M-35 grade, glossy type with grey cement andno pigment laid dry over and including a layer of 25 mm thick sand cushioning complete all as specified and directed. |
| 47 | Cutting into existing manholes for connecting new drains, making good existing benching for and forming branch channel (1/2 round or 3/4section) in cement concrete (1:2:4) type B-l smooth finished, and reforming benching as required complete all as specified and directed. |
| 48 | Sch \"A\" Part -II (E/M work) |
| 49 | Labour only for stretching, tightening, fixing and connecting ACSR conductor and GI wire of existing HT/LT overhead line any size and type, between pope to pole, approximate span length 45 to 50 Mtrs complete all as specified and directed for the following conductors :- |
| 50 | 2 Conductors with / without GI wire |
| 51 | 5 Conductors with / without GI wire |
| 52 | 6 Conductors with / without GI wire |
| 53 | M&L in repair/ replacementg for LT line PVC Spacers spiral type for the following:- |
| 54 | Spacer for two wire |
| 55 | Spacer for three wire |
| 56 | Spacer for four wire |
| 57 | M&L in repair for stay assy comprising of MS stay plate of size 23cmx23cmx6mm thick, stay rod with nuts 215cm ling 20mm dia, MS/GI stay bow 40cm lingh with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm of suitable length, loop insulation size 65x90mm clearance of hole 16mm & other accessories including excavation earth work & PCC work complete all as per SSR Pt-1 plate No-1 complete all as specified and directed. |
| 58 | Supply, laying & testingXLPEinsulatedarmoured heavy duty electric cable with aluminium conductor, 1100V grade, cross sectional area as given below:- |
| 59 | 3.5 core 120 sq.mm. |
| 60 | 3.5 core 95 sq.mm. |
| 61 | 3.5 core 70 sq.mm. |
| 62 | 3.5 core 50 sq.mm. |
| 63 | 4 core 35 Sqmm. |
| 64 | 4 core 25 sq.mm |
| 65 | 2 core 16 sq.mm. |
| 66 | 2 core 10 sq.mm. |
| 67 | Supply and laying sand river for cushioning with layers of sand 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified & directed. |
| 68 | Supply and layingbrick protection cable cover using sub class ‘B’ brickslaid flat adjacent to each other across the length of cable laid dry complete all as specified & directed by Engr-in-charge. |
| 69 | S&F in replacement galvanized pipe 80 mm bore light grade in trenches/road/nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. |
| 70 | All as per item above but size 50 mm bore light grade GI pipe |
| 71 | All as per item above but size 40 mm bore light grade GI pipe |
| 72 | M&L for Horizontal Boring of holes under road, pavement, hard standing by trenchless technology of required dia and necessary machine suitable for 0.4 mpa working pressure complete all as specified and directed. |
| 73 | S&F in replacement of following accessories installed in existing panel (Indoor/Outdoor) including making in coming/out going electric connections complete all as specified and directed |
| 74 | MCCB rating 250 Amp FP, Breaking capacity 36 kA,including over load and short circuit protection, 415 Volts. |
| 75 | -do- but rating FP 200 Amp, 36 kA |
| 76 | -do- but rating FP 160 Amp, 36 kA |
| 77 | –do- but rating FP 125 Amp, 25 kA |
| 78 | –do- but rating FP 100 Amp, 16 kA |
| 79 | –do- but rating FP 63 Amp, 16 kA |
| 80 | –do- but rating TP 100 Amp , 16kA |
| 81 | MCCB Four pole 630 Amp, 50kA Thermal magnitc adjustable type including over load and short circuit protection, 415 Volts complete all as specified and directed. |
| 82 | MCCB Four pole 400 Amp, 36/35kA, Thermal magnitc adjustable type including over load and short circuit protection, 415 Volts complete all as specified and directed. |
| 83 | S&F Onload Change over switch of capacity 100 A, 4 Pole, 415 Vols, 50 Hz, with Panel Mounted rotating handle, including dismantling old unserviceable change over switch by disconnection all incoming and outgoing electrical connection from existing indoor LT Panel complete all as specified and directed. |
| 84 | M&L earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level and covered surrounded from all sides with mixture of charcoal and common salt in alternate layers upto 15cm above top of plate and electrode connected to galvanized iron strip 32x6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and includingnecessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber (chamber size not less than 300x300x300mm interier diamentions), RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc. complete all as specified and directed.Note - The unit rate includes earth strip and new GI protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point. |
| 85 | All as per above but Copper electrode 300mmx300mmx3.00 mm thick and copper strip 25mmx3mm thick complete all as specified and directed. |
| 86 | Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron, UL listed, CPRI Tested at 25 KA fault current for one second and is provided with universal clamp made of SS earth enhancing compound shall be of 50kg/pit (resistivity is less than 0.12 Ohm meter) tested as per IEC 62561-7. The above arrangements shall be provided with heavy duty earth poly plastic pit cover of 6000 kg load bearing capacity (Size:270 x 240 x 200mm) and FRLS-H insulated copper conductor of size 6 sqmm, single core cable drawn through and including medium grade rigid PVC conduit upto 7 mtr incl cutting and chases on wall / floor and making good using PCC workcomplete all as specified and directed. |
| 87 | M&L for preparation of old painted surcaces using polish and painting one coats of aluminium paint on exposed surfaces to steel tubular 4 pole structure of 11 mtr including crossarms, Bracket etc including 5 Nos. of strip / bands painted with post office red and nevy blue colour (300 mm each) in alternate layer from coaping, marking of pole number with black synthetic enamel paint 2.5 cm height including in 6\" dia circle complete all as directed. |
| 88 | Ditto all as per item no 72 but LT/HT 2 pole structure. |
| 89 | Ditto all as per item no 72 but LT/HT pole 11 mtr single pole |
| 90 | Ditto all as per item no 72 but LT pole 9 mtr single pole |
| 91 | S&F in repair PVC Junction box of size 350x250x150 mm with Aluminium bus bars 04 Nos fixed on pole with the help of MS nuts bolts and MS clamps-2 Nos of size 40mm X5mm thick with one No MCB SP 6 Amp capacity includes making suitable hole on pole to take out connections to fitting if required at site and PVC insulated sheathed multistranded copper conductor 3 core 1.5 Sqmm for making connection from junction box to security light fitting complete including cable glands for incoming and outgoing cables complete all as specified and directed. |
| 92 | M&L for overhauling to outdoor/indoor type LT panel/feeder pillar box of any size/make including insulating to bus bars with shrinkable PVC sleeves of colours red, yellow, blue and black repair of worn out/US cables including replacement of door rubber beedings, nuts, bolts washers, hinges, thimbles/lugs, cable glands as requirement of site including carry out necessary welding work and make te system functional and testing on load complete all as specified and as directed at site by Engr-in-charge. |
| 93 | M&L for painting to indoor/outdoor type LT panel/FP box of size not more than 1.8 m height internally as well as external surfaces complete with one coats of synthetic enameled paint of approved quality including preparation of old surfaces, writing of bus bars & outgoing/incoming locations with white paint gridth upto 2” (50mm) complete all as specified and directed. |
| 94 | Supply and erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screw as specified of type 410 SP-31, 9 Meter long, including marking alternate yellow and black strips 30cm height - total - 5 Nos with two coats of aluminium paint over a coat of zinc chrome primer above embedded portion at GL, complete all as specified and directed. (Note - Earth work and PCC for foundation channels, clamps, nuts and bolts to be measured and paid for separately). |
| 95 | M&L in replacement for bracket made out of GI tubing 40 mm dia, light grade 1.5 mtr long including fixing with MS clamps -2 Nos made out of 50mm wide 5mm thick flat iron with MS nuts bolts 75 mm long 12 mm dia with-4 Nos & flat washer (3mm thick) 01 No for each including painting with aluminium paint over one coat of red oxide to the MS clamps & bracket etc complete all as specified and directed. |
| 96 | Supply, installation, testing and commissioning electrical cubical control panel board (KIOSK TYPE) Double door, CPRI approved an ISO 9001 factory assembled made out door pedestal type feeder pillar box wheather and vermin proof fabricated of 3.0mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB\"s including and Mounting measuring instrument such as Volt meter, Ammeter, Selector switchs, CT\"s -03 Set, Phase indicator lamps with holder, toggle switches and MCBs etc including incoming and outgoing cables connections with suitable cable glands and end termination including grouting of feeder pillar box 60 cm above ground level by providing 105 cm long angle iron size 50x50x6mm welded onall four corner embedded in PCC (1:2:4) using 20mm graded upto 45cm complete all as specified and directed. |
| 97 | LT Panelshall be consisting the following :-(a)4 Nos electrolytic aluminium bus bars high conductivity aluminium alloy proper insulated of 1 ½ times of the incoming capacity with provision of extension and mounting on porcelain support(b)MCCB FP 250 amps, 36 KA, 415 volts, 50Hz (Adjustable type) = 01 No (Incoming)(c)MCCBFP 160 amps, 25 KA , 415 volts, 50Hz (Thermal magnetic release and overload 80-100%) - 02 Nos (Outgoins) (d)MCCB FP 100 amps, 25KA , 415 volts, 50Hz (Thermal magnetic release and overload 80-100%) - 02 Nos (Outgoins) (e)Digital Panel mounted Amp meter 96 mm square type complete with selector switch complete with suitable size of CT\"s - 01 Set(f)Digital Panel mounted Volt meter 96 mm square type complete with selector switch - 01 Nos (g)Insulated Aluminium bus bars of suitable size shall be provided from the main bus bar to the out going MCCBs.(h)RYB indicating lamp, LED type - 01 sets.(i) Cost of PCC for foundation is deemed to be included in quoted rate by the contractor.(j) Drawing shall be approved by GE before placing the order. |
| 98 | Supply, installation, testing and commissioning electrical cubical control panel board (KIOSK TYPE) Double door, CPRI approved an ISO 9001 factory assembled made out door pedestal type feeder pillar box wheather and vermin proof fabricated of 3.0mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB\"s including and Mounting measuring instrument such as Volt meter, Ammeter, Selector switchs, CT\"s -03 Set, Phase indicator lamps with holder, toggle switches and MCBs etc including incoming and outgoing cables connections with suitable cable glands and end termination including grouting of feeder pillar box 60 cm above ground level by providing 105 cm long angle iron size 50x50x6mm welded onall four corner embedded in PCC (1:2:4) using 20mm graded upto 45cm complete all as specified and directed. |
| 99 | LT Panelshall be consisting the following :-(a)4 Nos electrolytic aluminium bus bars high conductivity aluminium alloy proper insulated of 1 ½ times of the incoming capacity with provision of extension and mounting on porcelain support(b)MCCBFP 160 amps, 36 KA, 415 volts, 50Hz (Adjustable type) = 01 No (Incoming)(c)MCCBFP 100 amps, 25 KA , 415 volts, 50Hz (Thermal magnetic release and overload 80-100%) - 02 Nos (Outgoins) (e)Digital Panel mounted Amp meter 96 mm square type complete with selector switch complete with suitable size of CT\"s - 01 Set(f)Digital Panel mounted Volt meter 96 mm square type complete with selector switch - 01 Nos (g)Insulated Aluminium bus bars of suitable size shall be provided from the main bus bar to the out going MCCBs.(h)RYB indicating lamp, LED type - 01 sets.(i) Cost of PCC for foundation is deemed to be included in quoted rate by the contractor.(j) Drawing shall be approved by GE/Engr-in Charge before placing the order. |
| 100 | S&F in replacement of security light fittings suitable for LED 70 watt 110 Lumens/watt IP65/IP66 housing cast Aluminium with lens complete with all accessories as directed. |
| 101 | S&F in replacment of security light fittings LED 45 watt with secondary lens luminaries IP 66, 5700K, with inbuilt surg diverter complete with all accessories as directed. |
| 102 | S&F in replacement of security light fittings suitable for LED 60 watt 110 Lumens/watt IP65 housing cast Aluminium with lens complete with all accessories as directed. |
| 103 | S&F in replacement of security light fittings suitable for LED 90 watt with lens complete with all accessories as directed. |
| 104 | S&F in replacement of Flood light fittings suitable for LED 120 watt IP 66 with lens complete with all accessories as directed. |
| 105 | S&F in replacement of Flood light fittings suitable for LED 150 watt IP 66 with lens complete with all accessories as directed. |
| 106 | S&F LED flood light luminaries of 200W, with pressure die cast aluminium housing with sealed toughened glass cover in frame, IP 65 protection and with all fixing arrangement, nuts, bolts and washer connecting to electric system with 2.5 Sqmm PVC Aluminium stranded conductor 2 core up to require length and to be fixed on 11 Mtr long pole including taking down old unserviceable fitting any type and description complete all as specified and directed. |
| 107 | S&F LED Solar street light fitting 12 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed. (Excavation & earth work shall be measured separately) |
| 108 | Taking down defective 25/36/40/45/60 Watt LED light fitting/SV/MH fittings, street light fitting mounted on pole/bldg on bracket disconnecting, testing all components, dismantling of defective components such as choke, igniters, holders, capacitors, and providing PVC cable for wiring lamps, including cleaning of cover, connection with supply and testing the street light fitting after fixing new components and including trimming of branch if obstacle for lights to illuminate the area and then mounting to its original position and making the fitting functional all as specified and directed. |
| 109 | Taking down defective 90/120 Watt led fitting mounted on 11 mtr long Semi high mast consisting of LED flood light fittings (Approx 4 to 6 Nos), street light fitting, mounted on 11/13mtr long high mast pole on bracket/round ring, disconnecting, testing all components, dismantling of defective components such as driver of LEDs and cleaning of cover, connection with supply and testing the street light fitting after fixing new components and then mounting to its original position and making the fitting functional all as specified and directed. |
| 110 | Taking down defective 250/400 Watt LED light fitting/SV/MH light fittings, High mast light fitting through motorised/manual system, mounted on 21 mtr long high mast pole on bracket/round ring, disconnecting, testing all components, dismantling of defective components such as choke, igniters, holders, capacitors, and providing new PVC cable for wiring lamps, including cleaning of cover, connection with supply and testing the street light fitting after fixing new components and then mounting to its original position and making the fitting functional all as specified and directed. |
| 111 | Supply only Driver for LED fitting 30 watt as per existing Make & Model |
| 112 | Supply only Driver for LED fitting 45 wattas per existing Make & Model |
| 113 | Supply only Driver for LED fitting 60 watt as per existing Make & Model |
| 114 | Supply only Driver for LED Flood fitting 100 watt as per existing Make & Model |
| 115 | Supply only Driver for LED Flood fitting 120 watt as per existing Make & Model |
| 116 | Supply only street light MCPCP for LED fitting 45 wattas per existing Make & Model |
| 117 | Supply only street light MCPCP for LED fitting 60 wattas per existing Make & Model |
| 118 | Supply only street light MCPCP for LED fitting 70 wattas per existing Make & Model |
| 119 | Supply only street light MCPCP for LED fitting 90 wattas per existing Make & Model |
| 120 | Supply only flood light MCPCP for LED fitting 120 wattas per existing Make & Model |
| 121 | Supply only PVC electric cable with insulated aluminium conductor (stranded) with inner sheathingof PVC tape and overall PVC sheathed 1100 volts grade, heavy duty, 16 sqmm twin core,weather proof flat with accessories, complete all as specified and directed. |
| 122 | All as per above but of size 10 Sqmm two core. |
| 123 | All as per above but of size 06 Sqmm two core. |
| 124 | All as per above but of size 04 Sqmm two core. |
| 125 | S&F in repair of u/s timer switch with new AlphaRex3, D22 Astro 1 channels astronomical digital timer switches including necessary connection complete all as specified & directed. |
| 126 | S&F in repair power Contactor 3 Phase with AC coil 220 volts, 32 Amp, CN432 T01 typeincluding making all connections complete all as specified & directed. |
| 127 | Servicing by means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter, bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for 63 KVA DG Set (Make:Kirloskar) Engine No.4H3445/120542, Machine No.JC/WC/6205/SIL/867K, Alternator No. ES3AO13B165088 at Pump House No. 4 at RTS & Depot Saharanpur including testing and commissioning. Note : (a) Spare parts shall be measured and paid separately under mentioned item of Sch \"A\". |
| 128 | Supply of lubricating Oil filter element with seal |
| 129 | Supply of Fuel filter element with seal |
| 130 | Supply of Air filter element |
| 131 | Supply of \"V\" belt make Funnder/good year (4PK-1158 EPDM Poly \"V\" Belt) |
| 132 | Supply of Hose pipe, including nut, bolts and clamps |
| 133 | Supply of Oil bypass filter element with seal |
| 134 | Supply of lubricating oil, grade 15W40 (K-oil premium) |
| 135 | Supply of inhibitor non corrosive coolant including mixed with distilled water as recommended ratio. |
| 136 | Servicing by means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for 30 KVA DG Set (Make:Kirloskar) Engine No.3H3025/1320572, Machine No.JKWL/30/SIL/8363K, Alternator No. 653C013B2506Hat Pump House No.2and at Cl-I hospitalat RTS & Depot Saharanpur including testing and commissioning. Note : Spare parts shall be measured and paid separately under mentioned item of Sch \"A\". |
| 137 | Supply of lubricating Oil filter element with seal |
| 138 | Supply of Fuel filter element with seal |
| 139 | Supply of Air filter element |
| 140 | Supply of poly\"V\" belt make Funnder/good year for 3H3025 Model, part No 4H 1493.01.0.00 in user manual of Kirloskar |
| 141 | Supply of \"V\" belt make Funner/good year A-55 |
| 142 | Supply of Hose pipe, including nut, bolts and clamps |
| 143 | Supply of Oil bypass filter element with seal |
| 144 | Supply of lubricating oil,cgrade 15W40 (K-oil premium) |
| 145 | Supply of inhibitor non corrosive coolant including mixed with distilled water as recommended ratio. |
| 146 | Taking down self starter assembly from (20 KVA DG Set) its position and repairing the same by replacement of carbon brush pinion etc reassembling of all parts refixing in position testing, commissioning complete all as specified and directed |
| 147 | Taking down dynamo 12 volt from the existing position, dismantling the same and repairing by turning of commutator replacing the armature, carbon brush varnishing the coil reassembling the parts and refixing in position testing and commissioning complete all as specified and directed. |
| 148 | M&L for repairs of battery charging unit including replacement of non functional step down transformer, its electrical connections, relays, terminal connections etc all as specified and directed by Engr-in-charge including one coat of synthetic enamel spray paint colour as approved by EIC, after cleaning dust dirt, oil and grease etc (Painting shall be carried out at site) |
| 149 | M&L in replacment of DSR digital regulator, for 30 KVA DG Set in the panel including connecting its electrical connections to relays, contactor 3P, CT 100/5, MCCB, bus bar, selector switch and phase indication neon lamp, all parts should be cleaning and removing the carbon, tighting the bolts and nuts for all parts including lugs and auxiliary electric connection, replace the rusted/damaged bolts, nuts, washers, phase separtor and lugs incl disconnection the electric supply and making connection all as specified and directed by Engr-in-Charge. |
| 150 | S&F in repair brass battery terminal heavy duty complete suitable for 12 volts Battery. |
| 151 | S&F PVC insulated multistranded copper wire lead for connecting battery of size 25 Sqmm complete all as directed |
| 152 | Supply onlydistilled water for batteries complete all as specified and as directed. |
| 153 | M&L for cleaning away all grass, vegetation, saplings, shrubs, undergrowth, roots and trees up to 50 cm girth from the area surrounding of E/M installations, under HT< over head lines, 4/2 pole structures, transforemer, installations, yards,surrounding valve chamers and removing the rubbish upto a distance 50 mtr outside the periphery of the area under clearance and dressing the area etc complete all as specified and directed. |
| 154 | M&L for cutting of tree branches of any sizes and dia,not less than 2 Mtr around the LT/HT OH line which obstructing the power supply/ maintenance of electric supply as well as illumination in area including repair of damage broken ACSR conductor, GI wire and jumpers and disposed exc 50 mtr away clearing area and testing of line, complete all as specified and directed. Note : (i) Span length is aproximate 40 to 50m. |
| 155 | Supply only for Filling/top up of insulation oil confirming IS-335, complete all as specified and directed. |
| 156 | Supply only Insulation electric tape roll 20 mm 25 mtr long complete. |
| 157 | Disconnecting carefully old unserviceable Ammeter from panel board and Supply & Fix of new 96 mm size square digital type ammeter of range 0-100 Ampere with set of CTs of suitable rating complete all as specified and directed. |
| 158 | Disconnecting carefully old unserviceable Voltmeter from panel board and Supply & Fix of new 96 mm size square digital type Voltmeter of range 0-500 Volt complete all as specified and directed. |
| 159 | S&F in replacement of LED type RYB indicating lamps on existing panel board including necessary fixing and connecting arrangement complete all as specified and directed |
| 160 | S&F in replacement of selector switch suitable for ammeter/ voltmeter including making electrical connection complete all as specified and directed. |
| 161 | S&F vertical type air break gang operated triple pole, mechanically operated, outdoor type with all fittings, accessories, mounted on and including HT 11 KV porcelain insulators and steel channel frame GI Operating rod 25 mm dia of suitable length worked from ground includinglocking arrangements, with 7 livers Naval brass lock, suitable for 200 Amps current rating complete. (set of three) |
| 162 | M&L for High tension/Low tension cable fault checking by high tension cable fault testing machine complete all as specified and directed |
| 163 | S&F and testing end termination jointing kit suitable for 1100V, 16-50 sqmm x 3.5/4 coreXLPE cable heat shrinkable joint complete with jointing material & assessories complete all as specified and directed |
| 164 | S&F and testing end termination jointing kit suitable for 1100V, 70-120 sqmm x 3.5/4 coreXLPE cable heat shrinkable joint complete with jointing material & assessories complete all as specified and directed |
| 165 | S&F cable jointing kit 11 KV (earthed) grade cable for straight through termination (Heat shrinkable) type joint complete with jointing material and all accessories for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 sqmm complete all as specified and directed. |
| 166 | S&F cable jointing kit 11 KV (earthed) grade cable for end termination (Heat shrinkable) type joint complete with jointing material and all accessories for 3 core XLPE armouredaluminium conductor cable of size 95to 120 sqmm complete all as specified and directed. |
| 167 | M&L for pin insulator porcelain type vitreous white brown including one galvanized mild steel spindle two galvanize iron washers and one galvanized iron nut 100 mm height, 65mm dia for 1100 V grade, complete all as specified and directed. |
| 168 | M&L for shackle type porcelain vitreous white, brown including one galvanized mild steel straps, washers, bolts and nuts 100 mm height, 115 mm dia, section of strap 31 x 5 mm for 1100 V grade, complete all as specified and directed. |
| 169 | Supply only Insulator pin type porcelain vitreous, white brown or green 150mm height and 150mm dia including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nutfor conductor working pressure 11000 volt grade, complete all as specified and directed. |
| 170 | Supply only Insulator disc type porcelain vitreous, white, brown or green 145 mm height and 255 mm dia ball and socket type single disk assembly for tension with tension clamp for conductor working pressure 11000 volt grade, complete all as specified and directed. |
| 171 | M&L in repair of Air termination single poined aluminium rod 12mm dia and 300 mm long complete all as specified and as directed |
| 172 | M&L in repair of test terminal block made of gun metal or phosphorus bronze size 75x75x25mm incl 3 nos, 8 mm ida 25mm long hex Head screw complete all as specified and as directed |
| 173 | S&F in repair of Earth continuity conductor aluminium strip 25x3mm with saddles and fixing screws etc in wall all complete as specified and directed |
| 174 | S&F in repair of earth continuity conductoror main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strip 32x6 mm complete all as specified and directed |
| 175 | Dismentling of ACSR conductor, service feeder or distribution spans complete all as specified and directed |
| 176 | Supplying, Stringing, Tightening, Fixing & connecting any type of ACSR conductor of any size for over Head LT/HT Line including aluminium binding wire or aluminium tape of suitable type clamps/ connector or other jointing material complete all as specified and directed. |
| 177 | M&L for stringing in replacement of steel wire 4 mm dia 8 SwG as continuous earth wire and grading incl cradal hexagonal binding properly with channel/Angles etc complete all as specified |
| 178 | Supply installation commisioning and testing high mast timer Panel outdoor typetotal enclosed weather proof dust vermin proof MS Sheet iron clad of 3.15 mm thick powder coated with inter connecting with copper wire and MS angle frame of40x40x5 mm complete comprising of the following :-INCOMINGS(a) MCB 4 POLE 415 V 63 A -01 No.OUTGOINGS(a) MCB 6-32 Amp - 1 No(b) 40 Amp TP Contactor -03 No (d) Digital type Ammeter including CTs and selector switch-01 No (e) Digital type Voltmeter and selector switches 0.500 - 1 No (f) Indicator RYB - 1 Set (g)Push Button and auto manual switch (Raise and low switch) (g) Timer- 1 No |
| 179 | M&L in replacement of unserviceable can type resin filled (Alpx3) capacitors with built-in terminal connectors on top and mounting stud on the bottom heavy duty 440 V Un all as per existingtype suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capacity. :- 25 KVAr |
| 180 | 15 KVAr |
| 181 | 10 KVAr |
| 182 | 5 KVAr |
| 183 | M&L in replacement of unserviceable digital power factor controller 4/6 step type with provision of manual and automatic mode operation conforms to IEC 61010-1, high accuracy, IP 41terminals with manual and automatic mode ooperationall as per existing type suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capapcity. |
| 184 | M&L in replacement of unserviceable capacitor switching unitcapcitor duty contactor consisting of mounting block and contactors, for switching capacitors, suitable to be installed directly on 3 pole, 9 to 40 A contactors all as per existing type suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capapcity. |
| 185 | M&L in replacement of unserviceable capacitor switching unitcapcitor duty contactor consisting of mounting block and contactors, for switching capacitors, suitable to be installed directly on 3 pole, 50 to 65 A contactors all as per existing type suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capapcity. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail