| 1 | Taking down cement or cement lime plaster on brick walls etc including backing, raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 2 | Material and Labourfor rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surface and finished even and smooth without using extra cement and applying two coats of oil bound distemper over and incl one coat of alkali resistant priming paint on newly plastered surfaces of wall complete all as specified and directed. |
| 3 | Material and Labourfor rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surface and finished fair and even without using extra cementand applying two coats of cement base paint including preparation of newly plastered surfaces of wall complete all as specified and directed. |
| 4 | Material and Labourfor rendering 10 mm thick on fair faces of brick work or concrete surfaces on ceiling in cement mortar 1:3. finishing even and smooth without using extra cement and applying three coats of white wash on ceiling including preparation of new plaster surfaces complete all as specified and directed . |
| 5 | Demolition of brickwork, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. |
| 6 | Material and Labourforbrick work with sub class \"B\" bricks (old size) straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4 complete all as specified and directed. |
| 7 | All as per Srl item No 06above but except bricks (old demolition serviceable bricks obtained fromshall be reused after necessary cleaning of mortar). |
| 8 | Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness ( below or above ground level) and disposing the rubbish to a distance exceeding 50 m but not exceeding 100 m away to low lying areas complete all as specified and directed. |
| 9 | Material and labour for 75mm thick PCC type B2, 1:2:4 ( using 40mm graded stone aggregate) in floors & pavings without using extra cement complete all as specified and directed. |
| 10 | Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 11 | Material and Labourglazed ceramic coloured wall tiles 450x350x7mm thick on vertical surfaces such as skirting and dados etc shade as approved by Engr-in-Charge set and jointed in neat cement slurry and pointed in coloured cement to match over & including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 12 | Material and Labourfor Non skid ceramic coloured tiles 7 to 8mm thick (Square/reactangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc shade as approved by Engr-in-Charge set and jountedin neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 13 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.Laid, bedded and pointed in any mortar; Complete all as specified and directed. |
| 14 | Material and Labourfor Machine cut Kota stone slab as in steps/ flooring 20-25 mm thick (size not less than 0.5 sqm each) over cement screed base of 15mm thick in cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 15 | All as per srl Item No 14 here-in-before but as skirting/dado over rendering 10mm thick in cement mortar 1:4. |
| 16 | Material and Labourfor PCC type B-2 (1:5:10) using 40 mm graded crushed stone aggregate 100mm thick as in apron and floor etc. complete all as specified and directed. |
| 17 | Material and Labourfor Cement concrete Machine pressed factory made interlockingtiles IS 15658-2006 of 60 mm thickness M-40 Grade, with neat cement slurry laid and jointed with grey cement slurry mixed with pigment with grey cement and no pigment as in floors complete all as specified and directed. |
| 18 | Material and Labourfor sand filling15mm thick for laying of interlocking block complete all as specified. |
| 19 | Material and Labourfor PCC 1:2:4 type B-1 (using 12.5 mm graded stone aggregates) as in roof kerb or mud stops,rounded or chamfered on edges and like including weathering slight rounded and throating complete all as specified and directed. |
| 20 | Material and LabourGranite (of any type) work (table rubbed and polished) 20mm thick in steps , jambs, pillars, window cills, cooking plateforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 21 | Taking down chowkhat with shuttering (without taking off shuttersfrom frame including grill & guard bars) sizeof shutter not exceeding 1.5 sqm each complete all as specified and directed. |
| 22 | Taking down chowkhat with shutters without taking off shutters from frame size of shutters exc. 1.5 but not exceed4 Sqm each complete all as specified and directed. |
| 23 | Taking down shutters of any description size of shutter not exc 1 sqm each complete all as specified and directed. |
| 24 | Taking down shutters of any description size of shutter exc 1 sqm but n.exc 2 sqm complete all as specified and directed. |
| 25 | Taking down Shutters of any description of size exceeding 1 sqm and not exceeding 2 sqm each complete and refixing in the same opening after easing and neccesary repair/adjustment all as specified and directed. |
| 26 | Supply and fixingpressed steel frame for doors with one or two rebates size of frame 125x60 mm including necessary fixing lungs hinges lock strike plate etc , filling PCC 1:2:4 type B-1 in frame complete all as specified and directed. |
| 27 | Supply and fixingfactory made 35 mm thick flush shutters solid core construction with block board core and plywood face panels incl neccesary fittings latches, mortice locks complete all as specified and directed. |
| 28 | Supply and fixing35 mm thick glazed and Skelton door shutters IInd class hard wood open rebated prepared to receive in SSR part-I class 8 (a) glass gage dividing in squares size of member complete all as specified and directed. NOTE : Glazing, wire gauge and painting shall be measured and paid for Separately. |
| 29 | Supply and fixingsolid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M S square tube, suppling & fixing in opening as per specifiaction & drawing complete all as specified and directed. |
| 30 | Supply and fixingFactory made solid panel PVC doorshutter 30 mm thick (style) con-sisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be cov-ered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain col-our PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 31 | Material and labour factory madeBox type steel window double (glazed & gauged) made of ERW tube P- section of size 60 mm x 25 mm double rebated outer frame comprise glazed skelton shutter door frame of ERW tube P-section size 50 mm x 20 mm with two Nos openable leaf cnsisting of two Nos of sash bar of T-sec 20 mm x 3 mm welded to frame with one No vertcale mullion of ERW of ERW box type T-section size of 60 mm x25 mm FI 2 mm thick welded / screwed to frame for fixing of wire guage/glass including fixture and fitting like as handle, tower bolt stopper , cleat, pintal hinges, holdfastprimer etc, all as shown on drg No.CEJZ/TD-06/07 and CEJZ/TD/07/07 as per existing size complete all as specified and directed. NOTE : Guard bar, Glazing, wire gauge and painting shall be measured and paid for Separately |
| 32 | Material and Labour for Box type steel ventilator made of ERW tube P-section of size 60mmx25mmouterframe ( single rebated), comprisesglazed shutter, frame of ERW tube and FI 2mm thick welded/screwed to frame for fixing ofsheet glassincluding fixture and fittingslike as Stopper, Cleat, Pintal hinges, holdfast etc all as shown on drg No CEJZ/TD1019/08 sheet 1/3 to 3/3 dt 01 May 2008 as per existing complete all as specified and directed.. NOTE : Guard bar, Glazing, wire gauge and painting shall be measured and paid for Separately. |
| 33 | Supply and fixingMS handles 150mm long, cast type anodised complete all as specified and directed. |
| 34 | Supply and fixingMS anodised barrel tower bolt 150mm long complete all as specified and directed. |
| 35 | Supply and fixing Floor door stopper of aluminium alloy body with hard drawn steel spring 140mm long complete all as specified and directed. |
| 36 | Supply and fixing300mm long aluminum alloy anodized sliding door bolt with hasp and staple(bolt type)and fixing clips of sheet cast or ectruded sec and fixing bolts and sliding bolts of extruded sec or cast aluminum alloy and fixed complete all as specified and directed. |
| 37 | Supply and fixingbutt hinges medium weight cold rolled stainless steel complete size 100mm complete all as specified and directed |
| 38 | Supply and fixingMS 300mm long ordinary Helical mild steelstove enameled black door springs including rollers and roller plate complete all as specified and directed. |
| 39 | Supply and fixing100mm long Hasp and staple , safety type, Aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed. |
| 40 | Supply and fixingstainless steel wire cloth, 0.36 mm nominal dia. of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 41 | Hacking out old brocken glass ( any thickness , size , quality or description ) from wooden/metal frames or stone, concrete or brick surrounds , glazed with putty or fixed with beads and Supply & Fixing 3mm thick Sheet glass, ordinary qualityand glazing with oil putty/wooden beading in squareexc 0.5 sq.m. in each pane ; Complete all as specified and directed. |
| 42 | All as per item no. 41 above but figured glass pin head type. |
| 43 | Material and Labourfor preparation of new wooden surfaces of any description , not otherwise described , over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 44 | Material and Labourtwo coats of synthetic enamel painting on steel surfaces of any description over 10 cm in width or girth not otherwise described above priming coat of red oxide including prepration of new surfaces complete all as specified and directed. |
| 45 | Dismantling of plain/corrugated steel sheeting incl ridge any gauge, thickness including Nainital or similar pattern roof coveringcomplete all as specified directed. |
| 46 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion, PCC bed in post hole etc.and making good disturbed ground complete all as specified and directed. |
| 47 | Material and Labourfor PCC (1:3:6) type C2 using 40mm graded aggregate for foundation filling and mass concrete etc. complete all as specified & directed. |
| 48 | Dismantling steel work of any description, in any position as in gates, posts, framed work etc. complete all as specified and directed. |
| 49 | Supply and fixing structuralsteel workconforming to Fe 290 (Grade E- 165)as in vertical posts, framings, etc. with or withoutY/U/Swan Neck made of angle or other section, made to shape complete including necessary cuttings, weldings, drillings as required and fixing complete all as specified & directed. |
| 50 | Supply and fixing structuralsteel workin tubular framing work conforming to IS 4923:1997 as in vertical posts, framings, etc. other section etc., made to shape complete including necessary cuttings, weldings, drillings as required and fixing complete all as specified & directed. |
| 51 | Supply and fixingPre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 52 | Supply and fixing G.I based plain steel sheet 0.50mm to 0.80mm thick of any colour having tensile strength of 550 MPa as in ridges, fixed with self taping screws complete all as specified and directed. |
| 53 | Dismantling water tanks and Supply & Fixing rotational moulded polythene water storage tanks of 500 litre capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-1 including Ball valves high pressure PTMT with epoxy coated Aluminium rod & High density plastic ball screwed for iron pipe and fixed to GI pipe of 20mm bore complete all as specified and directed. |
| 54 | Disconnecting existing tanks 500ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, including all fitting complete all as specified and directed. |
| 55 | Taking up or down 15mm bore steel tubing and connections , including cleaning for re-fixing or removal complete all as specified and directed. |
| 56 | Taking up or down 20mm bore steel tubing and connections , including cleaning for re-fixing or removal complete all as specified and directed. |
| 57 | Supply and fixing15mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed. |
| 58 | Supply and fixing20mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed. |
| 59 | Refixing 15mm old steel tubing and connections in new or old position (walls, ceiling , floors, etc.). Note:- old serviceable GI tubing obtained from taking down will be reused after necessary cleaning and with all new fittings. |
| 60 | Refixing 20mm old steel tubing and connections in new or old position (walls, ceiling , floors, etc.). Note:- old serviceable GI tubing obtained from taking down will be reused after necessary cleaning and with all new fittings. |
| 61 | Taking down eaves gutters and rain water pipes ( any size or pattern) , including all fittings , heads, shoes, bends, swan necks, etc., including cleaning or refixing or removal to store ( measured overall as fixed along the centre line over fittings and accessories complete all as specified and directed. |
| 62 | Supply and fixing110mm bore PVC(SWR) pipes single socketed in any lengthfixed to walls with dash true nut and bolt at every 2mtr length including)includingall fittings complete all as specified and directed. |
| 63 | Supply and fixing 110mm bore PVC (SWR) bend any radius complete all as specified and directed. |
| 64 | Supply and fixing110mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 65 | Supply and fixingin repair 100mm bore PVC (SWR) gully trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 66 | Supply and fixingin repairs vitreous china wash down water closet pan pedestal pattern white including fixing bolts incl white seat coverwith flat bottom and cover and mild steel chromium plated hinging device (excluding flushing cistern and flush pipe) complete all as specified and directed. |
| 67 | Supply and fixingin repairs vitreous china squatting pan of Orissa pattern size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) including making good the dismantled portion to match with existing surface of floor all as specified and directed. |
| 68 | Supply and fixingin repairs 10 ltrs capacity PVC valveless syphonic action flushing cistern low level with inlet ball valve, flush pipe of polythelene of low or high density or PVC 32mm dia comlplete all as specified and directed. |
| 69 | Supply and fixingin repairs plastic water closet seat cover white with flat bottom and cover and mild steel chromium plated hinging device complete all as specified and directed. |
| 70 | Supply and fixing in repairs Chromium plated Health faucet in repair with 1.5 metre long chaincomplete all as specified and directed. |
| 71 | Supply and fixingin repairs flushing jet including pipe for Europian type closet including fixing to 15m dia pipe suitable length with brass check nut complete all as specifed and directed. |
| 72 | Supply and fixingin repairs vitreous china wash hand basin white with flat back type size 550x400mm excluding taps chain and plug and porcelain stopper but including brackets CP waste coupling 32mm and PVC waste pipe 32mm dia including cutting for and pinning ends of brackets complete all as specified. |
| 73 | Supply and fixing600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 74 | Supply and fixingin repair Brass Chromium plated Tubular towel rail, 20 mm dia. D type, 60 cm long between flanges complete all as specified and directed. |
| 75 | Supply and fixingin repairs glass shelve assembly 60cm in oval shape consisting 5.5mm to 8mm thick glass including CP guard railing with double rail complete all as specified and directed. |
| 76 | Supply and fixingin repairs pillar taps 15mm dia cast copper alloy with capstan heads chromium plated screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipes. |
| 77 | Supply and fixingin repair PVC wastepipe 32mm dia suitable for WHB/Sink complete all as specified and directed. |
| 78 | Supply and fixingglass corner of 30cm radius made of 5.5mm thick sheet glass with CP guard rails fixed to walls with brackets complete all as specified and directed. |
| 79 | Supply and fixingin repairs CP shower rose fancy type with CP arm complete all as specified and directed. |
| 80 | Supply and fixingin repairs stop valves brass chromium plated 15mm dia with long shank and cup concealed type complete all as specified and directed. |
| 81 | Supply and fixingin repairs centre hole wall/ wash basin/ sink mixture cast copper alloy chromium plated with capston head srewed down high pressure withlettered hot or cold with long screwed shanks fly nut screwed for iron pipe 15mm dia complete all as specified and directed. |
| 82 | Supply and fixingin repairs chromium plated stop valve /Angle valve 15mm bore fancy type screwed down for high pressure complete all as specified and directed. |
| 83 | Supply and fixingin repairs PVC connection pipe 15mm dia 600mm long with brass check nut at both ends complete all as specified and directed. |
| 84 | Supply and fixingin repairs CP bib tap 15mm dia long body screw high pressure for iron pipe complete all as specified and directed. |
| 85 | Supply and fixingin repairs 100mm dia CP grating with or without hinge type or hole as required on site complete all specified and directed. |
| 86 | Supply and fixingin repair 25mm dia stainless steel Curtain rods/ rails with Brass brackets, stops, rollers, finials, 1 pair of Brass decorative knobs for each curtain rod etc.complete all as specified and directed. |
| 87 | Material and Labourfor repairing of chajja / roof projection by taking down old plaster and providing 10 mm thick rendering in cement mortar 1:3 including providing chicken mesh wire netting 25, gauge, 20 mm mesh, finishing the surface even & smooth with out using extra cement complete including neccsary scaffolding upto 08m height complete all as specified and directed. |
| 88 | Removal of plants / vegetation growth etc of height exc 30 cm but not exc 45 cm from roof/ground levelor parapet of building including removing of root and making good disturbed surface with cement mortar 1:3 including supply & mixing of liquid water proofing compound as per manufacturer instructions complete all as specified and directed. |
| 89 | Supply and fixingin repairs snake guard on doors size as required on site complete all specified and directed. |
| 90 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixtures and fittings such as switches, sockets, ceiling roses, lamp holders, regulators, etc., removing materials to store for keeping in safe custody or for taking credit (creit for above items shall be made as per condtitions separately) and making good disturbed surface of walls, floors, etc. as required including necessary cuttings chases complete all as specified and directed. |
| 91 | Material and Labour forpoint wiringin existing concealed conduit for followingpoint controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core FRLS PVC insulated unsheathed and multi stranded copper conductor cable 1100 volt ( ISI marked ) drawn through and existingPVC concealed/conduit with all fittings and accessories including pressed steel powder coated sunken terminal box suitable for Modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core FRLS PVC insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using CM (1:3) including fixing of switch/socket/lamp holder/ceiling rose complete all as specified and as directed :- Note:1. Switch/socket/lamp holder/ceiling rose shall be measured and paid for separately as supply only.a) For one light /fan/ buzzer point controlled by one 5 Amp switch one way |
| 92 | b).For one three pin socket outlet 5 Amps independent board complete |
| 93 | c) For one three pin 5 Amps socket outlet on the same board with other switches |
| 94 | All a per item No 90 here-in-abovebut with 2.5 Sq mm size cable multi stranded FRLS copper wire unsheathed for one 3 pin socket outlet 15 Amps on independent board including continuous earth wire of PVC insulated 2.5 Sq mm copper multi stranded conductor connecting to common earth dolly complete. |
| 95 | Material and Labour for surface point wiring for following point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core FRLS PVC insulated unsheathed and multi stranded copper conductor cable 1100 volt ( ISI marked ) drawn and including surface PVC conduit with all fittings and accessories i.e. pipe bend,pipe hook, elbow,juction boxes etc including pressed steel powder coated sunken terminal box suitable for Modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core FRLS PVC insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including fixing of switch/socket/regulator/lamp holder etc. complete all as specified and as directed :- Note:1.Switch/socket/lamp holder/ceiling rose shall be measured and paid for separately.a) For one light /fan/ buzzer point controlled by one 5 Amp switch one way |
| 96 | b).For one three pin socket outlet 5 Amps independent board complete |
| 97 | c) For one three pin 5 Amps socket outlet on the same board with other switches |
| 98 | All a per item No 94 here-in-abovebut with 2.5 Sq mm size cable multi stranded FRLS copper wire unsheathed for one 3 pin socket outlet 15 Amps on independent board including continuous earth wire of PVC insulated 2.5 Sq mm copper solid conductor connecting to common earth dolly complete. |
| 99 | Supply only Modular switch flush type one way 6 Amp, 230 volts complete all as specified and directed. |
| 100 | Supply only Modular socket 6 Amp 2/3 pin combined 2 modulecomplete all as specified and directed. |
| 101 | Supply only Modular switch flush type one way 16 Amp, 230 volts complete all as specified and directed. |
| 102 | Supply only Modular socket 6 /16 Amp 2/3 pin combined 2 modulecomplete all as specified and directed. |
| 103 | Supply only ceiling rose 65X50 mmthree terminals complete all as specified and directed. |
| 104 | Supply only Lamp holder bakellite type with black plate suitable for batten fitting complete all as specified and directed. |
| 105 | Supply and fixingModular stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd heavy duty 230 voltscomplete all as specified and dircted. |
| 106 | Supply and fixingin replacement sheet metal enlosure DBs double door factory made flush fixed complete with 200 amps rated bus-bar 240 volts single phase 8 ways including necessary brick work and plaster to match with the existing surface complete all as specified and directed. |
| 107 | Supply and fixing in replacement MCB single pole 6 to 32 Amps complete all as specified and directed. |
| 108 | Supply and fixing in replacement MCB DP 40 Amps 240V, 10 KA, complete all as specified and as directed |
| 109 | Supply and fix, in replacement Fresh Air fan of size 250mm, Plastic body 1200RPM, electrically driven, 230volts, 50Hz, single phase, AC supply, copper wounddynamically balanced impeller for smooth and vibration free operation, complete with louvers,nuts for fixing exhaust fan and 3\" long bolts, nuts for fixing louvers with civil work,wall hole, and provision of PVC insulated, flexible copper conductor cord of size 23/0.0076, three core from ceiling rose to fan complete all as specified and directed. Note: Material and labour for making suitable opening for fixing air fan as required shall be deemed included in the quoted rate of item. |
| 110 | Supply and fix, in replacement Exhaust fan of size 450 mm, Heavy duty 1200RPM, electrically driven, 240volts, 50Hz, single phase, AC supply, copper wounddynamically balanced impeller for smooth and vibration free operation, complete with louvers,nuts for fixing exhaust fan and 3\" long bolts, nuts for fixing louvers with civil work,wall hole, and provision of PVC insulated, flexible copper conductor cord of size 23/0.0076, three core from ceiling rose to exhaust fan for giving connectioncomplete all as specified and directed.Note:Material and labour for making suitable opening for fixing air fan as required shall be deemed included in the quoted rate of item. |
| 111 | Supply and fix in replacement LED tube light 20 watt, (4\" long), 6500K, wall mounted, E-lite LED curve with high lumen batten with efficacy not less than of 100 lumens, with integrated electronic driver complete with all accessories complete all as specified and directed. |
| 112 | Supply and fixingin replacement 1100 volts grade heavy duty PVC cable insulated aluminium conductor served with inner sheating of PVC tape and over all PVCsheathed in service connection stranded conductor flatr 6 sqmm 2 core cable complete all as specified and directed. |
| 113 | Supply and fixing Iin replacement LED street light fitting powder coated pressure die cast alminium compact High power LED street light with heat resistant toughened glass for 25 watt with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Devicebracket made out of GI Pipe 40mm medium grade 1.2 mtr long made to shape with fixing clamps of MS Flat 40x6mm nuts bolts Complete all as specified and directed. |
| 114 | Supply and fixingin replacement, Sub main wiring with two single pole 4 sqmm (nominal area) stranded copper conductor on surface FRLS PVC insulated and unsheathed cable drawn inexisting non metalic PVC rigid conduit medium grade of suitable size with all standared fitting ,including one run of continuous PVC insulated standed copper conductor PVC insulated stranded copper conductor FRLS cable 4 sqmm (nominal area) for earth continuty , including taking out and removal of old sub main wiring , complete all as specified and directed.Note:- 1 Two runs of 4 sqmm main cable one run of 4 sqmm for earth cableshall be measured as one unit/ one running meter. |
| 115 | Material and Labourin repairs Earthing complete with galvanized steel earth plate electrods of size 60cmx60cmx6mm thick burried directly in ground vertically(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized iron or steel earth wire 4 mm dia by means of bolts nuts check nuts and GI washers of Galvanised iron protected by steel pipe 15mm (light grade) all as shown in elecrrical plate No.3 of SSR Part-I and connecting to earthing test point (earth test point to be provided at 5 mtr distance from earth pit) and testing on completion including necessary excavation and earth work. The rate also include charcoal dust and salt in alternate layers 25 mm dia light grade GI pipe, funnel, wire mesh. Concrete 1:3:6 type C-1 for pit and RCC pit cover. The extra cost of the water- ing pipe,bends,elbows shall be included in the unit rate.Note : RCC pit cover shall be precast of RCC 1:2:4type B-1 80mm thick reinforced with XPM weighing notless than 4 Kg/Sqm complete all as specified and directed. |
| 116 | Material and Labour forin replacemennt earthing complete with galvanized steel earth plate electrod of size 60cmx60cmx6mm thick burried directly in ground vertically(earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron or steel earth wire 4 mm dia by means of bolts nuts check nuts and GI washers of Galvanised iron protected by steel pipe 15mm (light grade) all as shown in elecrrical plate No.3 of SSR Part-I and connecting to earthing test point (earth test point to be provided at 5 metre distance from earth pit) and testing on completion including necessary excavation and earth work. The rate also include charcoal dust and salt in alternate layers, 25 mm dia light grade GI pipe, funnel, wire mesh, Concrete 1:3:6 type C-1 for pit and RCC pit cover. The extra cost of the watering pipe, bends, elbows shall be included in the unit rate. Note : RCC pit cover shall be precast of RCC 1:2:4 type B-1 80mm thick reinforced with XPM weighing notless than 4 Kg/Sqm,complete all as specified and directed. |