| 1 | SCHEDULE \"A\" PART-I: B/R WORKS |
| 2 | Surface excavation n. exc 30cm deep & averaging 15cm deep & getting out in soft and loose soil . |
| 3 | Excavating in post holes (or similar holes) each n exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50m and making good surface and getting out in hard/dense soil. |
| 4 | Plain cement concrete type D2, 1:4:8 (40mm graded stone aggregate) in foundations, fillings and mass concrete. |
| 5 | Plain cement concrete type C2, 1:3:6 (40mm graded stone aggregate) in foundations, fillings and mass concrete. |
| 6 | M&L for hardcore of broken stone of guage n. exc63 mm deposited,spread and levelled in layers n. Exc 15 cm thick , water and ramed to a true surface |
| 7 | M&L for 100 mmcement concrete Type B-2,1:2:4 (40mm graded aggregate) in flooring/hard standing & finished the surfaces even and smooth with using extra cement all as specified and directed. |
| 8 | M&L sand cushioning in floors or paving, laid in layers n.exc 15 cm thick, spread levelled and rammed including watering all as specified and directed. |
| 9 | M&L machine pressed precast concrete interlocking paver block of any shape and size confirming to ISI 15658-2006 of 60 mm thickness M-35 grade with grey cement & with pigment all as specified and directed. |
| 10 | M&L for PCC 1:2:4 Type B-1 using 20 mm graded stone aggregate as in coping all as specified and directed. |
| 11 | S&F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 12 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 all as specified and directed by Engr in charge. |
| 13 | S&F Plates (plain or chequered) channels,square cut or notched (ordinary and counter sunk ) with riveted, bolted or welded attachment Fe 410-W (Gde-E- 250) all as specified and directed. |
| 14 | M&L for preparation of new steel surfaces exc 10cm width or girth and apply two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified. |
| 15 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft / loose soil. |
| 16 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. |
| 17 | Removing excavated material exc.50m but n exc.100 and depositing where directed at a level n exc. 1.5 m above the starting point. |
| 18 | Moorum/red bajri filling in floors or pavings, laid in layers n.exc. 15 cm thick,spread, levelled and rammed including watering |
| 19 | M&L for brick work with flyash bricks straight or curved on plan exc 6m mean radious built in cement mortar 1:6 |
| 20 | M&L for RCC 1:2:4 type B1 (20mm graded aggregate) in beams, Cantilevers, bressumers, lintels over 1.5m span etc. |
| 21 | M&L for RCC 1:2:4 type B1(20mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves. |
| 22 | M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips. |
| 23 | M&L deformed or twisted TMT bars 5 mm dia and over upto and incl 10mm, bent to shape required including cranking bending spirally for stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete. |
| 24 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. |
| 25 | M & L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings, Chajja and similar work, not exceeding 200mm thick (Horizontal or sloping). |
| 26 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finishing the surface fair and even using WPC as on external surface all as directed. |
| 27 | M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finishing the surface fair and even. |
| 28 | M&L fo Rendering 5 mm thick on fair faces ofconcrete surfaces in cement mortar 1:3 andfinished even and smooth without using extra cement |
| 29 | Supply only liquid water proofing compound |
| 30 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 31 | M&L for preparing newly plastered surfaces of applying three coats of white wash on ceiling. |
| 32 | M & L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding. 0.11 sqm on floor set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick rendering in cement mortar (1:4) for backing of tiles. |
| 33 | M & L for Coloured Glazed ceramic tiles 300 x 450 x 7 mm thick, on vertical surfaces such as skirting, dados and risers to stepsetc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 10 mm thick rendering in cement morter (1:4) |
| 34 | S&F for 20 mm CPVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified. |
| 35 | S&F for 15 mm CPVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified. |
| 36 | S&F in repairs Vitreous China wash down water closet pan 580 x 440 mm (Pedestal pattern) EWC white complete incl seat and cover, flush pipe incl all joints complete. |
| 37 | S/F in repairsPVC 10 ltr capacity low level flushing cistern white with inlet ball valve float and braket and 32 mm bore PVC flush pipe complete all as specified and directed. |
| 38 | S&F vitreous china wash basin flate back size 580 x 450 mm incl 32 mm waste chromium plated waste coupling including brackets complete all specified and as directed. |
| 39 | S & F in repairs 15 mm bore chromium plated bib tap fancy type cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule. |
| 40 | S&F in repairs 15mm bore dia angular stop valve cast copper alloy screwed down, high pressure with crutch or butter fly handle, screwed both ends for pipe or for unions and fixed complete all as specified and directed. |
| 41 | S & F in repair 15 mm bore pillar taps, fancy type Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts, screwed for iron pipe. |
| 42 | S/F 15mm dia PVC connection pipe with PTMT nuts of length 450mm all as directed |
| 43 | S&F in repairs chromium plated tubular towel rail,20 mm dia D type 60 cm long between flanges all as directed. |
| 44 | S&F shelf of PTMT fixed with and incl CP brass screws and wooden/plastic cleats |
| 45 | M&L for PVC (SWR) floortrap 100 mm dia , plain with grating including jointing withcement concrete type B1. |
| 46 | S&F in repairs 600mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers. |
| 47 | S & F for soild PVC Door frame of size 50 mm x 47 mm made out of 5 mm wood grain wood grain colour PVC sheet reinforced with MS square tube, suppling and fixing in opening as per specification and drawing. |
| 48 | S & F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails.M.S frame shall bw covered with heat moulded wood grain colour PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and botom rail on either side & as gap insert for tip rail & bottom rails; Panelling of plain colour PVC sheet to be fitted in the MS frame weloded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement. suppling and fixing in the frame at site as per specification & drawing. |
| 49 | S & F 75 mm long extruded Aluminium alloy anodised Butt hinges with galvanized mild steel hingepin type C 22. |
| 50 | S & F 100 mm long Aluminium, anodised, barrel tower bolts of extruded section |
| 51 | S & F 125 mm long Extruded Aluminium alloy handles, fabricated type, anodised. |
| 52 | Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified |
| 53 | M&L for 3mm thich Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane. |
| 54 | S&F 75 mm dia PVC (SWR) pipes single cocketed, in any length, in rubber ring joints fixed in walls. |
| 55 | S&F 110 mm dia PVC (SWR) pipes single cocketed, in any length, in rubber ring joints fixed in walls. |
| 56 | S&F 110 mm dia bore PVC (SWR)bends of any radius |
| 57 | S&F 110 mm dia bore PVC (SWR)bendswith access door of anyradius |
| 58 | S&F in Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 litres capacity including taking down old tank allas specified and directed. |
| 59 | M&L LLDPE Septic tank of 10 users (conventional) design to carry sewage and sludge water, excavation in any type of soil PCC 1:4:8 below foundation vent shaft connection etc complete all as specified and directed. |
| 60 | M&L for PlainCement Concrete Type C1 1:3:6 (using 20mm graded granite stone aggregate) cast in situ in lintels up to 1.5 M span, cillsand other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work , demolition of concrete blockupto 3rd floor |
| 61 | S&F Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at jointsupto 3rd floor |
| 62 | S & F in repairs framed work such as grills grating, etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conformingto FE 290, Gde E-165 complete all as specified and as directed upto 3rd floor |
| 63 | S&F 30 mm thick factory made second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc, divided in to squares with plain, chamfered or rounded mitred and rebated sash bars any numbers, edges of framing plain, chamfered or rounded, fitted with cut mitered beads for securing glass etc all as per clause 8.24 (b) of SSR Part I 2009upto 3rd floor |
| 64 | S&F 75mm long medium weightMS butt hinges upto 3rd floor |
| 65 | S&F 100 mm aluminium handles, cast type anodisedupto 3rd floor |
| 66 | S&F 100 mm aluminium anodised barrel tower bolt of extruded sectionupto 3rd floor |
| 67 | M&L for preparation of new wooden surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of primerupto 3rd floor |
| 68 | S &F for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings upto 3rd storey directions of Engineer-in-Charge |
| 69 | S&F for Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws including 100mm powder coated handles and 100mm powder coated handles all complete as per architectural drawings and the directions of Engineer-in-charge upto 3rd storey |
| 70 | S & F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with stainless steel wire stapels including old or new beading complete all as specified and as directed upto 3rd floor |
| 71 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the top surface even and smooth without using extra cement with necessary safety measures i.e.scaffoldings/hanging platform upto 3rd floor complete all as directed |
| 72 | M&L for Preparing newly Plastered surfaces of walls and applying two coats ofdistemper oil emulsion (Oil bound washable distemper) over a Coat of chalk whitening complete all as specified and directed. |
| 73 | SCHEDULE \"A\" PART-II: E/M WORKS |
| 74 | M & L For Point Wiring complete with 1100 Volts, FR Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through suitable sized PVC Conduit concealed/cassing capping in Walls / Roofs / Floors / Ceiling etc. and Modular Type Pressed Metal Flush Box made out ofGI Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Pointcontrolled by One Switch[Note- The PVC Conduit to Concealed in wall through cutting,Chassing,Pining in making good surfacing where required and pointing in cement mortar and making good for same unit rates are inculded for same] |
| 75 | Description all as per item No. 73 above but for 5 / 6 Amps switch socket out let, same board complete all as specified |
| 76 | Supply and fixing Modular switch 1 way 6A, 1 module single polecomplete all as specified and directed by Engr-in-charge. |
| 77 | Supply and fixingof Socket, 6A - 2/3 pin combined 2 module, 230 volt,multipurpose, complete all as specified. |
| 78 | Supply and fixing ceiling rose surface bake litewith 3 terminals complete all as specified and directed by Engr-in-charge. |
| 79 | S & FBuilding Security light LED type of 35 Watt Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 40mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge. |
| 80 | Supply and fixing LED lights fitting20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilingrose complete. |
| 81 | Supply and fix Exhaust fan, steel body AC single Phase. 230V of size upto 300mm sweep with blades, frame and louvers including making suitable hole for fixing Exhaust fan and making good to disturbed surface, matching with existing paint complete all as specified and directed. |
| 82 | Supply and fixingFactory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt,4Way, IP-42 protection with 100 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s ,complete all as specified. |
| 83 | Supply and fixingof MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA \"C\" series,complete all as specified |
| 84 | Supply and fixing MCB 63Amp, 240 Volt, SPN, breaking capacity 10 KA \"C\" series, , complete all as specified |
| 85 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core,, complete all as specified and directed. |
| 86 | Excavation in trenches not exc.1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for laying of cable complete all as specified. |
| 87 | Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified |
| 88 | Removing excavated surplus soils meterial not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified. |
| 89 | Material and labour fornatural river sand as cushioning of cables, including spreading and punning down complete all as specifiedand directed by Engineer in charge. Note : punned thickness shall be measured for payment purpose |
| 90 | Supply and laying in trenche sold size bricks common burnt clay sub class \"B\" complete all asspecified & directed |
| 91 | Material and labour for50 mm dia GI steeltubes \"light grade\"for cable protection including sealing both ends complete all as specified and as directed by Engineer-in-charge. |
| 92 | Material and labour forcutting existing road/PCC/drain for laying of underground cable and including necessary earth work and making good to match with the exisitng surface with PCC1:3:6 type CI using 20mm graded aggregates complete all as specified and as directed. |
| 93 | Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm (1.0\"\") dia in trench/ surface/walls etc and complete all as specified and directed |
| 94 | Supply and fix gun-metal gate valves, with iron wheel, head, screwed both ends of size 25mm complete all as specified and directed. |
| 95 | Cutting or screwing fromexisting GI/CI tubingof any size for alteration or additions suitable size for 25 mm dia complete all as specified and directed |
| 96 | Material and labour forcutting existing road/PCC/drain for laying of underground cable and including necessary earth work and making good to match with the exisitng surface with PCC1:3:6 type CI using 20mm graded aggregates complete all as specified and as directed. |