Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking out Runway/Taxiway/Traffic light carefully from CI Transformer housing boxes by unscrewing nuts bolts and detaching isolating transformer and electrical connection repairing the same by opening Cover, re-wiring the Light Fitting with 6.0Sqmm solif Copper Conductor XLPECable, replacing unserviceable Parts as required/ordered,re-fixing Light Fitting in Original Position after repaired and connecting up, complete all as specified and as directed.NOTE:– (a) Spare Parts such as Lamp, Holder, Isolating transformer, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’. (b) Labour Element for replacement of unserviceable Parts is deemed to be included in the QUOTED UNIT RATE. |
| 2 | Taking out unserviceable UGControl Cable/ Runway lighting cable of any cross sectional area etc laying in trenchesall as specified and directed. |
| 3 | Taking out ATC Beacon from ATC Tower for repair and replacement of unsv component repair/rewinding of Synchronous motor and electrical connection repairing the same by opening Cover, rewiring the Light Fitting with 4 Sqmm Copper Conductor Cablereplacing unserviceable Parts as required/ordered,re-fix ing Beacon in Original Position after repaired and connecting up, complete all as specified and as directed.NOTE:– (a) Spare Parts such as Lamp, Holder, Control cable, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’.(b) Labour Element for replacement of unserviceable Parts is deemed to be included in the QUOTED UNIT RATE. |
| 4 | M&L Segregation ofall parts of single phase 240 voltsSynchronous Motor of any type, make and capacity obtained from item no 3 above, cutting & removing existing burnt/short circuited winding wire complete, cleaning of core grooves and surfaces, rewinding the motor with superior quality enamelled copper winding wire of as original gauge, numbers of turns and coils including insulating material such as sleeves, cotton/PVC tape varnishing etc, reassembling the motorcomplete all as specified and directed. |
| 5 | Repair ofConstant current regulator panel at ATC CCR room by carefully opening of panel and removing unsv component and repair of unserviceable remote control desk ,including replacement of unserviceable IC,IGBT, Chip, IC Card, 20KW Transformer with panel control wiring complete all as specified and directed. NOTE:– (a) Spare Parts such as IC,Chip, PCB electronic Card etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’.(b) Labour Element for replacement of unserviceable Parts is deemed to be included in the QUOTED UNIT RATE. |
| 6 | Supply Only IGBT as per sample for Constant current regulator 20 KW complete all as specified and directed. |
| 7 | Supply Only chip as per sample for Constant current regulator 20KWcomplete all as specified and directed. |
| 8 | Supply Only PCB Electronic card as per sample for Constant current regulator 20 KW complete all as specified and directed. |
| 9 | Supply Only 20 KW output current transformer as per sample complete all as specified and directed. |
| 10 | Repair of unserviceable Constant current regulator panel at ATC CCR room by carefully opening of panel and removing unserviceable component and repair of unserviceable remote control desk ,including replacement of unserviceable IC,IGBT, Chip, IC Card, 7.5 KW Transformer with panel control wiring complete all as specified and directed. NOTE:– (a) Spare Parts such as IC,Chip, PCB electronic Card etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’.(b) Labour Element for replacement of unserviceable Parts is deemed to be included in the QUOTED UNIT RATE. |
| 11 | Supply Only IGBT as per sample for Constant current regulator 7.5 KW complete all as specified and directed. |
| 12 | Supply Only chip as per sample for Constant current regulator 7.5 KW complete all as specified and directed. |
| 13 | Supply Only PCB Electronic card as per sample for Constant current regulator 7.5 KW complete all as specified and directed. |
| 14 | Supply Only 7.5KW output current transformer as per sample complete all as specified and directed. |
| 15 | Supply laying & testing LT UG XLPE sheathed PVC insulated, screened PVC bedded, Galvanised Steel Strip of Wire armoured Electric Power Cable heavy duty with stranded Aluminium Conductor 1100 Volt grade, cross-sectional area 16 Sqmm 4 Core, laid in trenches/surface of Wall/in GI Pipe along with Pole for connection to OH Lines including Brass Cable Glands Mild Steel Flat Iron Clamps, etc., complete all as specified and directed.NOTE : Earthwork, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items. |
| 16 | Supply laying & testing LT UG XLPE sheathed PVC insulated, screened PVC bedded, Galvanised Steel Strip of Wire armoured Electric Power Cable heavy duty with stranded Aluminium Conductor 1100 Volt grade, cross-sectional area 25 Sqmm 3.5 Core, laid in trenches/surface of Wall/in GI Pipe along with Pole for connection to OH Lines including Brass Cable Glands Mild Steel Flat Iron Clamps, etc., complete all as specified and directed.NOTE : Earthwork, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items. |
| 17 | Supply laying & testing LT UG XLPE sheathed PVC insulated, screened PVC bedded, Galvanised Steel Strip of Wire armoured Electric Power Cable heavy duty with stranded Aluminium Conductor 1100 Volt grade, cross-sectional area 50 Sqmm 3.5 Core, laid in trenches/surface of Wall/in GI Pipe along with Pole for connection to OH Lines including Brass Cable Glands Mild Steel Flat Iron Clamps, etc., complete all as specified and directed.NOTE : Earthwork, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items. |
| 18 | Supply,installation,testing and replacement of bidirectional approach light suitable for 200W, 6.6 Amp AC constant current series system with bi pin halogen Lamp complete with all accessories such as base plate ,breakable coupling,mounting assembly,gasket, Lamp Holder,Lenses,bi pin,Secondary lead of adequate length etc confirming to ICAO Annex 14 complete bidirectional type with following fitments all as specified and as directed. |
| 19 | Clear /Clear |
| 20 | 180 degree clear /Yellow |
| 21 | 180 degree Green /Red |
| 22 | 180 degree Amber/Yellow |
| 23 | S&F in repair, Omni directional taxi way edge light suitable for use with 45 W 6.6 A AC constant current series system complete with accessories such as base plate breakable coupling mounting assembly gasket lamp holder lenses bi pin secondary lead of adequate length confirming to ICAO Annex 14 complete all as specified and directed. |
| 24 | S&F in repair, for the following Spares for taxiway/Runway light fittings. |
| 25 | Halogen lamp bipin holder 200W ,6.6 Amp. |
| 26 | Halogen lamp bipin holder 45W ,6.6 Amp. |
| 27 | 180 deg Colour filters for runway lighting Red/Green/Yellow/Clear |
| 28 | Clear spreader lens for APN approach light |
| 29 | Green spreader lens for APN threshold light |
| 30 | Red spreader lens for APN end light |
| 31 | Base plate without gasket and bolts |
| 32 | 360 deg outer clear lens for AUN Runway light fittimg. |
| 33 | AMA connector kits for 6 sqmmcopper conductor cable,5 KV Grade |
| 34 | Breakable coupling for R/W/Taxi fittings |
| 35 | Supply installation testing in replacementof isolating transformer 5KV, 50 H Series type encapsulated in polyster resin for all moulded with neoprene rubber as specified and suitable for Air field lighting System confirming to FAA/ICAO andIS 12290 1987 of capacity200Watt, 6.6 Amp for runway lighting complete all as specified and directed. (Note:-Excavation,Sand cushioning, protective covering and refilling the trenches etc shall be measured and paid Separately) |
| 36 | Supply installation testing in replacementof isolating transformer 5KV, 50 H Series type encapsulated in polyster resin for all moulded with neoprene rubber as specified and suitable for Air field lighting System conforming to FAA/ICAO andIS 12290 1987 of capacity45W ,6.6Amp,for runway lighting complete all as specified and directed. |
| 37 | Supply, laying, jointing, testing and commisioning in replacement6 Sqmm Airfield lighting cable single core 5KV Grade solidcopper conductor PVC insulated PVC sheathed unshielded antitermiteand anti rodent treated unarmoured cable generally conforming to IS 1554 part I as amended upto date complete all as specified and directed. |
| 38 | Supply and replacement of cast iron transformer housing boxes water tight cylindrical metal container of size 330 mm dia and 450 mm high all round cast iron moulding except top which will be 15 mm thick having two earth bolts nuts and washers 10 mm dia and one hole with GI nut to suit entry of 50 mm dia pipe .Opening on top with a cover plate to be fixed with neoprene rubber gasket etc ,including painting with one coat of synthetic paint as required including cement concrete/foundationPCC 1:2:4 using 20 mm graded crushed stone aggregate thickness of concrete 150mm in all the sides and 100 mm in bottom including dressing of earth soil and finishing with 12mm thick cement plaster 1:3 on exposed surface including necessary excavation and earth work in any type of soil complete all as directed. |
| 39 | M&L earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means ofbolts & nuts,check nuts & washers made of galvanised steel, earth wire protected by and including PCC (1:2:4) type B1 precast RCC cover slab(1:2:4, type B1)reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth wire GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completionincluding dismantling/taking out the existing unserviceable eathing complete all as specified and as directed. |
| 40 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of cables etc and getting out in soft/loose soil complete all as specified and as directed. |
| 41 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed. |
| 42 | Removing excavated material n.exc 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed. |
| 43 | M & L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180 mm thickness, complete all as specified and as directed. Note : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for. |
| 44 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed. |
| 45 | S&F in repair GI Tubing light grade of size 50mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc complete all as specified and directed. |
| 46 | S&F in repair GI Tubing light grade of size 80mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc complete all as specified and directed. |
| 47 | Repair and Maintenance of \"H\" & \"T\" indicator lampsincluding replacement of control wiring, painting of H/T indicator with existing yellow paint complete all as specified and all as directed. NOTE:– (a) Spare Parts such as Lamp, Holder, Control cable, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’.(b) Labour Element for replacement of unserviceable Parts is deemed to be included in the QUOTED UNIT RATE. |
| 48 | Supply only Lamp of Higher suitable intensity as per aviation standard and as per sample obtained from item No 47 here in before suitable for H/T indicator complete all as directed. |
| 49 | Supply only Lamp holderas per sample obtained from item No 47 here in before suitable for H/T indicator complete all as directed. |
| 50 | Supply of Beacon halogen 500W light as per sample obtained from item No 3 here in before suitable for ATC Beacon complete all as specified and directed by Engr in charge. |
| 51 | S&F in repair, LED Traffic lightsfitting Green / Red in Colour of 200mm dia with poly carbonate moulded body Red / Green in colour alongwith control box complete all as specified and directed . |
| 52 | Servicing/Overhauling of 3 Phase, 3HP capacity Induction Motoralongwith movable housing with following others repairs :-(a)Taking out Motor and movable housing from its Position and disconnecting all Cable Connections.(b)Dismantaling of induction Motor complete Part by Part carefully, testing all Coils, degreasing bearing and display all the Parts without damaging any portion for inspection of Engineer-in-Charge to ascertain the Serviceability of existing Parts.(c)Heating & Varnishing to Stator with super quality varnish and dried out properely with external heat as ordered and as directed.(d)Reassembeling the Motor complete with all existingServiceable Parts obtained, greasing the Bearing with bearing grease and new Parts as ordered by Engineer-in-Charge (New Parts shall be measured and paid separately under relevant Itemhere-in after) (e)Reinstall the Motor at its existing Position, connecting all Cable connections and testing on completion complete all as directed. NOTE: i)Any unforeseen Minor Repairs and Minor Parts which are required to complete the repair work for smooth functioning of Motor are deemed to be included with the Unit Rate andlabour element involved in replacementis included in unit rate quoated against this Item.(ii)Transportation of motorparts for machining, rewinding from work site to lathe shop (Work shop) are deemed to be included with the Unit Rate.(iii)Rewinding ofMotor, any machine workwhere involved shall be measured and paid separetely against relevant Item of this Schedule. |
| 53 | M&L Rewinding burnt coilsof Induction Motor of any make and type of capacity, 3Phase, 3HP, 415Volts with super enamelled copper winding wire as per existing size and guage to achieve therequired /specifiedRPM including taking out old unserviceable winding, cleaning/ repairing damaged slots, complete all as specified and as directed. |
| 54 | S&F in repair,3 phase ,32A/415 V plastic handle Reverse Forward Switch for 3 HP induction motor complete all as specified and directed. Make:- Fybross or equivalent in reputed supplier. |
| 55 | S&F in repair, 3 phase,DOL Reversing Starters,complete with combination of 2 AC Electro Mechanical Contactor, with protection relay, Overload protection, Phase Loss, Phase Unbalance ,Suitable for 3 HP induction motor complete all as specified and directed. |
| 56 | Greasing and overhauling of Hanger door guiding rail wheel, includingreplacement of unserviceable shaft bearings, GI wire rope, broken shaft of door mechanismfor smooth movement ofthe hanger door leaves complete all as specified and directed..NOTE:– (a) Spare Parts such as Bearing, Wheel shaft, Wheel etc. wherever required to be included in the QUOTED UNIT RATE. (b) Labour Element for replacement of unserviceable Parts is deemed to be included in the QUOTED UNIT RATE. |
| 57 | S&F in repair,\"V\"/ Chain belt drive for Transfer of power to hanger gate lower wheel, complete all as specified and as directed. |
| 58 | S&F in repair, MCCB 4 Pole 250 Amps, thermal magnetic type DN2-250D with breaking capacity 36 KA with thermal magnetic release at 415 volts, including spreader terminal, complete all as specified and as directed. |
| 59 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Polewith necessary lugs including dismantling/taking out old unserviceable cable complete all as specified and as directed. |
| 60 | Taking down existing unserviceable Highbay light /Flood Light of any description/type/ size ,carefully from hanger Ceiling height of 18 mtr, batten/conduitincludingremovalof batten/ conduit/ gutties/ wooden boardscomplete all as specified and directed. |
| 61 | Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. |
| 62 | Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as directed. |
| 63 | M&L Surface type sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing cappingmedium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE: (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 64 | M&L Surface type sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing cappingmedium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE: (i) Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 65 | M&L Surface type sub-main wiring alongwith earth wire of size of 4 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing cappingmedium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE: (i) Four runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 66 | M&L Surface type sub-main wiring alongwith earth wire of size of 4 x 10.0 sq. mm + 1 x 10.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing cappingmedium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE: (i) Four runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 67 | S&F in repair,Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 Flood light fitting luminaire, with system efficiency ≥110 lumen/W,AC120-300 Volts with high power LEDs as light source and Secondary lenses 10KV SPD included with high efficiciency electronic driver of capacity 120 watts, with pre wired andnecessary mounting arrangement and provision of 4.00 sq mm three core flexable copper conductor cable multi stranded ,connected to existing points in Hanger beam angle of any description complete all as directed. |
| 68 | S&F in repair,Energy saving new generation environmental friendly long life with high luminious efficacy upto ≥ 150 LPW versatile presure die cast aluminium IP 66 protectedHighbay light fitting luminaire with descrete high lumen LEDs as light source and electronic driver of capacity 150 watts with pre wired andnecessary mounting arrangement and provision of 4.00 sq mm three core flexable copper conductor cable multi stranded,connected to existing points in Hanger beam angle of any description complete all as directed. |
| 69 | S&F in repair, LEDs aviation light energy saving new generation environmental friendly long life versatile presure die cast aluminium housing with polycarbonate enclosure with pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 and for fixing taking GI pipe pipe medium grade 40 mm dia 1.5 mtr long, complete all as specified and as directed. |
| 70 | S&F in repair, Electronic LED driver 150/200 watt for Highbay/Flood lightsuitable 220/230/240 Volt,complete all as specifiedas directed |
| 71 | S&F in repair, 600mm x 600mm ultra slim mounted LED module with high brightness, de-glaring PP diffuser and PS LGP de-glaring sheet for glare free uniform light distribution suitable for grid ceiling LEDluminarie 40 Watt, (or next nearer higher watt) 6500Kwith diffuser to ensure glare free and even light distribution& integrated electronic driver,with all accessories, suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply,complete all as specified and as directed. |
| 72 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 doubledoor, Triple pole & neutral with 200 Amps rated bus bar, 240 Volts, IP-43 protection,complete including. blanking plates as required &flush to wall/other surface complete all as specified and as directed |
| 73 | S&F Sheet metal enclosure plug and socket, with three pin earth plug with socket with one Triple pole MCB 63 Amps, 5 pin for three phase connection, complete all as specified and as directed |
| 74 | S&F MCB, FP C Series 240 Volts, 63 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 75 | S&F Sheet metal enclosure plug and socket with one Single pole neutral MCB 20 Amps, complete all as specified and as directed |
| 76 | S&FMCB, SPN, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 77 | S&F MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 78 | S&F MCCB 4 Pole 200 Amps, thermal magnetic release, 415V ,50 Hz ,breaking capacity 36 KAcomplete all as specified and as directed. |
| 79 | S&F in repair, VTPN DB, 12 Way, double door,Metal door ,IP-43 IK 09, with and including MCCB200 Amps, 4 Pole (upto 200Amps)incomer, and MCB;s as Outgoing , 250Amps rated bus bars,earth bar,neutral links, no. of module complete including blanking plates as required & fixed flush to wall and making good the disturbed surfaces includingcomplete all as specified and as direct. Note:- MCB\"s required as Outgoing shall be measured and pair seperately under appropiate items |
| 80 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. seperating serviceable fittings/fixtures, keeping in safe custody reuse under respective item and removal of unserviceable material from site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 81 | M&L surface point wiring for light/fan/bell, buzzer points controlled by one, one way switch complete controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing cappingmedium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, GI modular suken terminal box [0,7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitablyto accomadiate flush type regulators] concealed in walls, withwith back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i)Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. |
| 82 | All as per item No 81here-in-above but One socket out let 5/6 amps point on the same board |
| 83 | All as per item No 81here-in-above but One socket out let 5/6 amps point on the independent board |
| 84 | All as per item No 81here-in-above but One Light point controlled by two numbers two way switches 5/6 Amps. |
| 85 | M&L surface point wiring for One socket outlet 15 Amps point on independent board pointcontrolled by one way switch 15/16 amps complete with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing cappingmedium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, GI modular suken terminal box [0.7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitablyto accomadiate fittings] concealed in walls, withand including back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i)Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. |
| 86 | M&L surface point wiring for One socket outlet 15 Amps point on independent board pointcontrolled by one way switch 15/16 amps complete with 4.00 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing cappingmedium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 4.00 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, GI modular suken terminal box [0.7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitablyto accomadiate fittings] concealed in walls, withand including back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i)Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. |
| 87 | S&F Modular Switch 1 way 6 Amps, 1 module, complete all as specified and directed. |
| 88 | S&F Modular Switch 1 way 16 Amps, 1 module, complete all as specified and directed. |
| 89 | S&F Modular Switch Socket 6 Amps, 5/6pin, 2 module, complete all as specified and directed. |
| 90 | S&F Modular Switch Socket 6 A/ 16 Amps, 6 pin combined 2 module, complete all as specified and directed |
| 91 | S&F Modular Bell push Switch 1 way 6 Amps, 1 module, complete all as specified and directed. |
| 92 | S&F ceiling rose, 3 phase PVC/ polycarbonate, insulated body, three terminals, complete all as specified and as directed |
| 93 | S&F Modular fan regulator, step type, 120 watt, 2 module, complete all as specified and directed. |
| 94 | S&F lamp holder, insulated PVC/ Polycarbonate body, with back plate suitable for batten/anglefittings complete all as specified and directed. |
| 95 | S&F Modular Blank plate complete all as specified and directed. |
| 96 | S&F Call Bellsuitable for work on 230 Volts complete all as specified and directed. |
| 97 | S&F in repair, Sheet metal enclosure for 8 way Distribution Boards (DB’s), IP-43 doubledoor, Single pole & neutral with 200 Amps rated bus bar, 240 Volts,IP-43 protection, including blanking plates as required complete all as specified and as directed |
| 98 | Servicing/Overhauling of 3 Phase, Pressure 12 Kgf/Cm2 capacity 500 Ltr Compressoralongwith movable housing with following others repairs and as mentioned below:-(a) Taking out Motor and movable housing from its Position and disconnecting all Cable Connections.(b) Dismantaling of induction Motor complete Part by Part carefully, testing all Coils, degreasing bearing and display all the Parts without damaging any portion for inspection of Engineer-in-Charge to ascertain the Serviceability of existing Parts.(c) Heating & Varnishing to Stator with super quality varnish and dried out properely with external heat as ordered and as directed.(d) Reassembeling the Motor complete with all existingServiceable Parts obtained, greasing the Bearing with bearing grease and new Parts as ordered by Engineer-in-Charge (New Parts shall be measured and paid separately under relevant Itemhere-in after) (e) Reinstall the Motor at its existing Position, connecting all Cable connections and testing on completion complete all as specified and as directed. (f) Refilling of compressor oil as required at site and as directed.(g)Taking out unserviceable Automatic Cut off Relay and limit switches refixing the same as required at site.(h)Taking out unserviceable Pressure Release valve refixing the same as required at site. (j)Taking out unserviceable Star Delta starter refixing the same as required at site.NOTE: i)Any unforeseen Minor Repairs and Minor Parts which are required to complete the repair work for smooth functioning of Motor are deemed to be included with the Unit Rate andlabour element involved in replacementis included in unit rate quoated against this Item.(ii) Transportation of motorparts for machining, rewinding from work site to lathe shop (Work shop) are deemed to be included with the Unit Rate.(iii) Rewinding ofMotor, any machine workwhere involved shall be measured and paid separetely against relevant Item of this Schedule. (iv) Replacement of Compreesor oil, Automatic Cut off Relay, limit switches, Timmer, Air Nozzle and Star Delta starter wil be paid under supply only. |
| 99 | Rewinding burnt coilsof Induction Motor of any make and type of capacity, 3Phase, upto 20HP, 415Volts with super enamelled copper winding wire as per existing size and guage to achieve therequired /specifiedRPM including taking out old unserviceable winding, cleaning/ repairing damaged slots, complete all asdirected. |
| 100 | Supply Compressor oil as approved complete all asdirected. |
| 101 | Supply OnlyLimit Air Switch as approved complete all asdirected. |
| 102 | Supply OnlyAutomatic cut off relay as approved complete all asdirected. |
| 103 | Supply Only Automatic timer as approved complete all asdirected. |
| 104 | Supply Only Automatic Star Delta starter for motor ofcapacity 30 HPas approved complete all asdirected. |
| 105 | Supply OnlyAir Outlet Nozzle and regulator as approved complete all asdirected. |
| 106 | Servicing/Overhauling of 3 Phase, 40KVA UPSalongwith with following others repairs and and as mentioned below:-(a) Taking out Vertiv Make UPS from its Position and disconnecting all Cable Connections.(b) Dismantaling of Vertiv make UPSand removing unsv Part carefully, testing all Connection for inspection of Engineer-in-Charge to ascertain the Serviceability of existing Parts.(c) Replacement of unsv Rectifier / Inverter / static bypass switch /Chip/relay/Semiconductor devices/diode and other Power electronics parts(d) Reassembeling the UPS complete with all existingServiceable Parts obtained as ordered by Engineer-in-Charge (g) Taking out unsv Automatic Cut off Relay andrefixing the same as required at site. NOTE: i)Any unforeseen Minor Repairs and Minor Parts which are required to complete the repair work for smooth functioning of UPS are deemed to be included with the Unit Rate andlabour element involved in replacementis included in unit rate quoated against this Item.(ii)Transportation of Unsvparts for machining including workshop charges are deemed to be included with the Unit Rate.(iii) New Chip/relay/Semiconductor devices/diode and other Power electronics parts for UPS will be included in quoted unit rate.Also Enginnering /consultancy charge from the company Rep will be bourne by contractor self. |
| 107 | M&L maintance free chemical Earthing system complete with 3 Nos pure copper earth rods 17mm did, 3000mm long electrode dipped fully in earthing Ennob chemical Backfill compound (EBFC) with minimum 3 Nos of 30Kg bag buried in ground to bore holes 200mm dia vertically to a depth not less than 3.5 mtr deep below the ground level with top edge of earth electrode at a depth not less than 3000mm below normal ground level, interconnected each other parallely in traingle shape horizontaly with provision of copper bus bar of size 32mm x 6mm for interconnection with copper earth lead strip 32mmx6mm for further connected to test point block NABL lab certified back fill eath enhancing compound for filling 3 x bore holes with soil mixedso as to achieve eath resistance below 1 Ohms includingnecessary Excavation in Soft/Loose Soil, Returning, Filling in and removal of Surplus Spoil upto a distance of 50.00 METRE and provision of Poly Plastic Pit cover for each eathingand testing on completion including taking dismantling/taking unserviceable Earthing complete all as specified and as directedNOTES : (i) The unit rate includes for protection pipe and copper strip from top of earth plate up to 7.00 meter above ground level. |
| 108 | S&F in repair of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles duly fixed over insulatorsor any other indicatedsituation for loop earthing etc as required with 32 x 6mm copper strip duly brazedcomplete all as specified and directed. |
| 109 | S&F in repair Test point terminal block made of gun metal or Phosphorus bronze size 75 x 75 x 25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw in a test point boxcomplete all as specified and as directed. |
| 110 | M&L 40mm bore GI pipe light grade with all necessary fittings (ISI marked) as in earthing strip protection laid in trenches/road/floor complete all as specified and as directed. |
| 111 | M&L earthing complete with Galvanised steel Earth Plate Electrode 600mm x 600mm x 6mm, thick burieddirectlyin ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below Normal Ground Level, connectedto GI earthstrip 32X6 mm drawn through and including Galvanised Ironprotection Pipe 40 mm bore (dia) Light grade up to heightof the transformer foundation where transformer issituated by means of Bolts, Nuts, Check Nuts and Washers etc Earth plate surrounded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150mm thick PCC Pit in cement concrete 1:3:6 (20 mm graded aggregrate ), Precast RCC1:2:4 (20mm graded aggregrate )cover slab 350 x350 x 50mm thick reinforced with and including 8mm dia TMT Bars @ 10 cmCentre to Centreboth ways GIWire Mesh , Funnel, with GI Watering Pipe 20mm bore dia Medium grade necessary excavation in soft loose soil returning filling in and removal of surplus soil upto a distance of 50 meter and all asshown in Electrical Plate No. 3 of MES schedule Part- I and testing on completion complete all as specified and as directed. |
| 112 | S&F in repair,Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with 32x6mm galvanised iron strip complete all as specified and as directed. |
| 113 | M & L earthing complete with copper Earth Plate Electrode 600mm x 600mm x 3.15mm, thick burieddirectlyin ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below Normal Ground Level, connectedto Copper earthstrip 20x3mm drawn through and including Galvanised Ironprotection Pipe 40 mm bore (dia) Light grade up to heightof the transformer foundation where transformer issituated by means of Bolts, Nuts, Check Nuts and Washers etc Earth plate surrounded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150mm thick PCC Pit in cement concrete 1:3:6 (20 mm graded aggregrate ), Precast RCC1:2:4 (20mm graded aggregrate )cover slab 350 x350 x 50mm thick reinforced with and including 8mm dia TMT Bars @ 10 cmCentre to Centreboth ways GIWire Mesh , Funnel, with GI Watering Pipe 20mm bore dia Medium grade necessary excavation in soft loose soil returning filling in and removal of surplus soil upto a distance of 50 meter and all asshown in Electrical Plate No. 3 of MES schedule Part- I and testing on completion complete all as specified and as directed. |
| 114 | S&F in repair PVC insulated sheathed multicore cable copper conductor 1.50 Sqmm, 3 Core complete all as specified and as directed |
| 115 | S&F in repair PVC insulated sheathed multicore cable copper conductor 2.50 Sqmm, 3 Core complete all as specified and as directed |
| 116 | S&F in repair PVC insulated sheathed multicore cable copper conductor 2.50 Sqmm, 4 Core complete all as specified and as directed |
| 117 | S&F in repair PVC square box 100mm x 100mm including refixing of old switch socket complete all as specified and as directed. |
| 118 | S&F in repair PVC square box 170mm x 100mm including refixing of old switch socket complete all as specified and as directed. |
| 119 | S&F in repair PVC square box 200mm x 150mm including refixing of old switch socket complete all as specified and as directed. |
| 120 | S&F in repair PVC square box 300mm x250mm including refixing of old switch socket complete all as specified and as directed. |
| 121 | S&F in repair 25x16mm, medium grade, PVC casing and capping duly fixed with casing pins and connecting accessories like Tee , Bends , elbow etc required as per site complete all as direced. |
| 122 | S&F in repair 25mm dia medium grade PVC Conduitduly fixed with Clamps on wall surfacesand connecting accessories like Tee , Bends , elbow etc required as per site complete all as direced. |
| 123 | S&F in repair elecrtic motor 5HP assembly including gearbox of hanger door and connecting acessories technically as per existing duly fixed to wheels of hanger including necessary cutting/welding, fabricating of steel structure to accomodate motor complete all as direced. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail