| 1 | Note: (i) Please refer Schedule \"A\" Notes given in tender documents.(ii)The Schedule \"A\" at BOQ Ser No 3.01 to 6.12 is not estimatedby MES and the estimated rate indicated as \"Rs. 0.00\" under Col. 5 signifies this fact only. |
| 2 | LUMPSUM/PREPRICED SCHEDULES OF WORKS |
| 3 | Lump sum price worked out by the contractor for Sch \"A\" Part-I ( Building works) carried forward from pre-priced Schedule. |
| 4 | Lump sum price worked out by the contractor for Sch \"A\" Part-IA ( Incomplete Building works) carried forward from pre-priced Schedule. |
| 5 | Lump sum price worked out by the contractor for Sch \"A\" Part-II (Internal Water Supply) carried forward from pre-priced Schedule. |
| 6 | Lump sum price worked out by the contractor for Sch \"A\" Part-III (Sec-I)(Internal Electrification) carried forward from pre-priced Schedule. |
| 7 | Lump sum price worked out by the contractor for Sch \"A\" Part-IV (Sec-I) (Sewage Disposal) carried forward from pre-priced Schedule |
| 8 | Lump sum price worked out by the contractor for Sch \"A\" Part-V (Area Drainage Works) carried forward from pre-priced Schedule |
| 9 | Lump sum price worked out by the contractor for Schedule \"A\" Part-VI (Sec-I) (Compound Wall , Fencing & Gate ) carried forward from pre-priced Schedule. |
| 10 | Lump sum price worked out by the contractor for Schedule \"A\" Part-VII (Protective Work) carried forward from pre-priced Schedule. |
| 11 | Lump sum price worked out by the contractor for Schedule \"A\" Part-VIII(External Water Supply Works) carried forward from pre-priced Schedule. |
| 12 | Lump sum price worked out by the contractor for Schedule \"A\" Part-IX(Road,Path culvert Works) carried forward from pre-priced Schedule. |
| 13 | Lump sum price worked out by the contractor for Schedule \"A\" Part-X (Sec- I) (External Electric Supply Works) carried forward from pre-priced Schedule. |
| 14 | Lump sum price worked out by the contractor for Sch \"A\" Part-XI (Site Clearance and Earth work) for works covered under Sch \"A\" Part-II to X) carried forward from pre-priced Schedule. |
| 15 | Lump sum price worked out by the contractor for Sch \"A\" Part-XII (Rectification Of DefectiveWork) carried forward from pre-priced Schedule. |
| 16 | MISCELLANEOUS ITEMS OF WORKS (SCHEDULE \"A\" PART-III(Sec-II))INTERNAL ELECTRIFICATION WORKS |
| 17 | Supply and fix lamp holder bracket type with LED lamp 7W, PVC/Polycarbonate type with skirt cap suitable for batten fitting, complete all as specified and directed. |
| 18 | Supply and fixing VELOCITY ceiling fan AC single phase 230V / 240V 50 Hz of size 1200mm sweep, 290 RPM and complete with connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts complete all as specified and directed. MAKE : HAVELLSMODEL:VELOCITY OR EQUIVALENT IN KHAITAN / CROMPTON GREAVES |
| 19 | Supply and fixing VENTILAIR DX PVC ventilation fan AC single phase 230V /240V 50 HZ of 200mm dia sweep, 1350 RPM with louvers, shutter and connecting up ceiling rose complete all as specified and directed.MAKE : HAVELLSMODEL:VENTILAIR DX OR EQUIVALENT IN KHAITAN / CROMPTON GREAVES |
| 20 | Sheet metal enclosure for DB\"sfactory made,double door, 240 volts , 50Hz, with IP-42 protection, single pole and neutral 8 way with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as directed (Make :Cat Part No DHDPSHODRW08 of Havells or equivalent of Schneider/ Legrand) |
| 21 | Sheet metal enclosure for DB\"sfactory made,double door, 240 volts , 50Hz, with IP-42 protection, single pole and neutral 4 way with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as directed (Make :Cat Part No DHDNSHODAW04 of Havells or equivalent of Schneider/ Legrand) |
| 22 | MCB SP 6 Amps 240 volt, 50Hz, 10KA, C curve made from moulded self extinguising thermostat plastic complete all as specified and as directed. Make: Havells cat Part No.DHMGBSPF006SCHEINDER/C&S. |
| 23 | MCB SPN 16 Amps 240 volt, 50Hz, 10KA, C curve made from moulded self extinguising thermostat plastic complete all as specified and as directed. Make: Havells cat Part No.DHMGCSNF006-032SCHEINDER/C&S. |
| 24 | MCB SPN 20 Amps 240 volt, 50Hz, 10KA, C curve made from moulded self extinguising thermostat plastic complete all as specified and as directed. Make: Havells cat Part No.DHMGCSPF006-032SCHEINDER/C&S. |
| 25 | MCB SPN 40 Amps 240 volt, 50Hz, 10KA, C curve made from moulded self extinguising thermostat plastic complete all as specified and as directed. Make: Havells cat Part No.DHMGCSNF040SCHEINDER/C&S. |
| 26 | 20W LED fitting (4 ft)6000K surface and wall mounted New E-lite LED curve high lumen batten with efficacy of 100 lumensin and including LED lampMake: Havells Model No LHEXBXPNN1W020or equivalent in Bajaj/Havells/Philips. |
| 27 | 10W LED fitting (4 ft)6000K surface and wall mounted New E-lite LED curve high lumen batten with efficacy of 100 lumensin and including LED lampMake: Havells Model No LHEXBXPNN1W010or equivalent in Bajaj/Havells/Philips. |
| 28 | 20W LED5700 K street light fitting in and including LED lampsmade up ofpressure die cast aluminiumhousing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP 65 protection and impact resistance of IK07 complete all as specified and testing on completion and includingn GI wall mounting bracket 40 mm dia 1.2 Mtr long incl 30 degree bend with 02 No FI clamps 25x3mm size with necessary nut bolts etc.Make -Havells Cat part No LHETBXU7PA6S020 or equivalent in Philips, CG . |
| 29 | MISCELLANEOUS ITEMS OF WORKS (SCHEDULE \"A\" PART-IV (Sec-II))SEWAGE DISPOSAL WORKS |
| 30 | S & F LLDPE septic tank with upflow filter including media designed to carry sewage and sullage water, excavation in any type of soil , PCC 1:4:8 below foundation , vent shaft , connection etc complete for 10 users complete all as specified and as directed. |
| 31 | MISCELLANEOUS ITEMS OF WORKS (SCHEDULE \"A\" PART-VI (Sec-II))COMPOUND WALL , FENCING & GATEWORKS |
| 32 | S&F Punched Tape Concertina Coil (including spike and handle) with 56 loops and dia 600mm, Max covered length 8 RM, having a core wire of high carbon spring steel of high tensile strength. The punched tape and copre wire (2.5 + 0.35mm dia) shall be heavy galvanized (IS-1730) (Wire-275GSM & strip-200 GSM) to provided protection against out door exposure. The punched tape shall mechanically crimped over the core wire and then formed into a coil at various parts of the periphery of the coil. The width of strip as 19mm and spacing of blades 24.00 + 0.5 mm C/C. The weight of each coil shall be 8 + 5% Kgs without packing material and coil lenth 8 Mtr (maximum) when opened up each coil would with bituminzed hessian cloth for providing protective packing Ref specification No CQAE/5660/1620/a for raw material and drawings IMGA-0112/B (Sheet 1 of 2), IMPD-1821, IMPD-1822 complete all as specified & directed. |
| 33 | MISCELLANEOUS ITEMS OF WORKS (SCHEDULE \"A\" PART-X (Sec-II))EXTERNAL ELECTRIC SUPPLYWORKS |
| 34 | New generation energy saving and environmental friendly long life LED street light 70 Watts made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in SPD of Cat Part No-LHETBXU7JA7B070 of make Havellsor eqvt. In CG / Philips/Surya. |
| 35 | Security light bracket made of GI tubing 40 mm dia light grade 1.5 Mtr long bend to shape at an angle 120 degree with necessary MS clamp, nuts & bolts etc. with one coat of red oxide and two coat of aluminium paint complete all as specified and as directed. |
| 36 | PVC cable loop box of size 200mm x 140mmx 95mm out door type duly fitted on bottom of steel poles with suitable clamp, nut, bolt & washers complete with porcelain insulated connectors for in and out going connections, MCB SP 6 Amp , complete all as specified and directed.Make : Sintex or equivalant |
| 37 | Wiring through the poles for two runs of PVC insulated single core FR cable with multistranded copper conductor of 2.5 Sqmm cross sectional area, 1100 Volts grade, drawn through poles and connecting to the street light feeders, all as specified and directed. |
| 38 | Supply testing and commisioning of LT panel board made out of 2.00 mm thick CRCA sheet and 50 x50 x 6mm thick angle iron frame duly powder coated indoor type suiblable for 3 phase 4 wire system 415 volts 50 Hz with copper bus bar of capacity 100 amps with epoxy insulators pre wired with single core PVC insulated multistranded copper conductor cable 1100 volts grade with digital volts meter 0-500 volts and ammeter 0-50 amps with for volt meter and ammeter, danger notice board etc. all switch gear must be placed individually cubicle and provision of cable glands for incomming and out going cable as per existing size cable. the LT Pannel board shoudl comprising the following :- (a)MCCB 32 Amp, 4 pole, 415 KA (Incomer) =01(b)MCB 20 A, triple pole, 415V, 16 KA (outgoing) = 02 |
| 39 | Supply testing and commisioning of panel board made out of 2.0mm thick CRCA sheet and 50 x 50 x 6mm thick angle iron fram duly powder coated indoor type suitable for 3 phase 4 wire system 415 volts 50 Hz with copper bus bar of capacity 100 amps with epoxy insulators pre wired with single core PVC insulated multistranded copper conductor calbe 1100 volts grade with digital volts meter 0-500 volts and ammeter 0-100 amps with suitable CTs and LED type indicator lamps for 3 phase and selector switch for volt meter and ammeter, danger notice board etc. all switch gear must be placed individually cubicle and provision of cable glands for incomming and out going cable as per existing size cable. The LT panel board shoudl comprising of the following :-(a) MCCB 63 amp, 4 pole, 415V, 16 KVA (Incomer)=01(b) MCCB 25A, four pole, 415V, 16 KA (outgoing) =02 |
| 40 | Supply, fabrication and fixing of sheet metal enclosure in made out of MS sheet of 3.15mm thick bend to shape and size factory made with welding bending works suitable for and including 100amp rated bus bar (length of bus bar not less than 60cm) for numbers makingholes of any size and mounted on porcelain/epoxy based post insulators of appropriate size with suitalbe size of nuts, bolts and washers, incoming MCCB-32 Amp TOP-01 Nos complete with mounting leg of size 25 x 25 x 4mm and length of angle iron 60cm above gound level, 45 centimeter and embedded in PCC below ground level including painting or complete structure with two coats of super enameled synthetic paint over a coat of red oxide complete all as specified and directed. |
| 41 | Supply, installation, testing and commissioning of silent diesel engine driven generating set developing suitable BHP as recommended by the manufacturer air cooled of capacity 40 KVA (32 KW), 415 Volts, 0.8 power factor , mounted on common base frame coupled, 1500 RPM, with silencer pipe protected with asbestos rope independently supported from engine to outside of power house up to 1.00 meter, AVM pads, foundation as per manufacturer\"s design, battery start with suitable cable for connectionfrom DG Set to panel boardcomplete with acoustic enclosure as per specification of central pollution control board and includingthe following:- |
| 42 | (A) PRIME MOVER.Vertical diesel engine of suitable capacity having suitable BHP as recommended by the manufacturer air cooled, closed circuit as per BS-649 or IS-10002The DG set shall be capable of running 24 hrs continouslywith 10% overloading for one hour in every 12 hours as per BS-5514/BS-649. Engine shall be equipped with all standard fitting as per manufacture\"srecomendations and mounted on common base frame with following fittings:i) RPM cum hour meterii) Battery charging ammeteriii) Ignition key and starting with push button switch.iv) Lubrication oil pressure gauge.v) Electronic Governor controlling.vi) Oil temp. gaugevii) Safety control (Trip) for the following:- (aa) Low lubricating oil pressure (ab)Over speed.viii)High engine temp tripix) 24/12 volts starting equipment compresing of all followings:-(aa) 01 No 12 volts 180 AH battery. Make:Exide / Amaron(ab) Battery charging alternator with inbuilt regulator.(ac) Starter motor of suitable capacity . (ad) Battery leads (copper cable) of suitable size with terminal.Make of engine: Kirloskar/Cummins/ Crompton Greaves Ltd |
| 43 | (B) ALTERNATOR:- Alternator rating 40 KVA (32 KW), 3 phase, 50 cycles 415 Volt, 4 wire supply at0.8 power factor running @1500 RPM, self excited self regulated, mountedon a strong fabricated steel frame, suitable for mounting on a permanent foundation to be coupled with above engine. The alternator shall be conforming to BS-2613 or IS-4722.Make: Kirloskar/ crompton/ Stamford/GFE |
| 44 | (C ) CONTROL PANEL:- Alternator control panel floor mounted cubical type with internal copper wiring for 40KVA alternator, 415 volts, 3 phase 4 wire, 50 cycles fabricated outof 1.6mm thick MS Steel, painted externally with two coats of synthetic enamel paintover one coat of primer including following accessories:- (i) suitable scale flush mounted AC voltmeter with selector switch 0-500 volts : 1 set(ii) Suitable scale flush mounted ammeter with selector switch and CT\"sof suitable range : 1 set(iii) frequency meter: 01 No(iv) KWH meter: 01 No(v) MCCB Suitable range- 01 No. (forincoming) as recommmended by manufacturer (vi) Set of copper bus bar of suitable capacity. |
| 45 | D) OTHER FITTINGS :- i) Fuel Tank : MS fuel tank of suitable capacity as per manufacture\"s instructions capable to store fuelfor 12 hours running of DG set including oil level indicating guage, drain and air vent plug etc. |
| 46 | SCHEDULE \"A\" PART-XIII CREDIT SCHEDULE |
| 47 | Rates of credit for TMT steel per kg offered/quoted by the bidder. Notes:- (i) Refer Page 21 of tender for details. (ii) The rates quoted in this cell of BOQ will not affect the contract sum but shall be applicable for credit of steel if steel lying at site is not found usable after testing. (iii) The rates applicable for credit Sch shall be higher of the rates quoted by the bidder and inserted by the deptt in Sch of credit. |