| 1 | Taking down of cement or cement plaster work any description from brick or stone wall etc including roof facia, scrubbing down with water etccomplete all as specified and directed by Engineer-in-charge.Note :Cost for use of scafolding upto 10 mtr height of building is including in this item. |
| 2 | M & L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work/stone or concrete surfaces including roof facia and finishing the surface even and smooth without using extra cement incl WPC complete all as specified and directed by Engineer-in-charge.Note:-(a) Water proofing compound should be measured and paid separately under item Sch\"A\" (b) Cost for use of scafolding upto 10 mtr height of building is including in this item. |
| 3 | M&L for 10mm thick rendering on fair faces of brick work or concrete surfaces on any type of masonry surface in cement mortar 1:6 without using extra cement complete all as specified and directed by Engineer-in-Charge.Note:-(a) Cost for use of scafolding upto 10 mtr height of building is including in this item. |
| 4 | M&L for 5 mm thick plaster in cement mortar (1:3) on surface of ceiling and finishing the surface even and smooth without using extra cement all as specified and directed by Engineer-in-Charge.Note:-(a) Cost for use of scafolding upto 10 mtr height of building is including in this item. |
| 5 | Supply only Liquid water proofing compound. |
| 6 | M & L for preparing newly plastered/unplastered or previously untreated walls surfaces and applying two coats of cement base paint over one coat of primer on plastered surfaces,complete all as specified and directed by Engineer-in-charge.Note :Cost for use of scafolding upto 10 mtr height of building is including in this item. |
| 7 | M&L for preparing new plastered surfaces and applying two coat of oil emulsion (bound) disptemper over one coat of primer on wall complete all as specified and directed by Engineer-in-Charge.Note :Cost for use of scafolding upto 10 mtr height of building is including in this item. |
| 8 | M&L for preparing new plastered surfaces and applying two coat of oil emulsion (bound) disptemper on ceiling complete all as specified and directed by Engineer-in-Charge.Note :Cost for use of scafolding upto 10 mtr height of building is including in this item. |
| 9 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish outside MoD land complete all as specified and directed. |
| 10 | M&L Glazed ceramic coloured (colour & shade as approved) tile 450x300x7 mm thick on vertical surface such as skirting / dado set and jointed in neat cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white/ coloured cement with pigment to match the colour of tiles complete all as specified and directed. |
| 11 | Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match & including 20 mm thick screed in cement mortar (1:6) and pointed in white/ coloured cement with pigment to match the colour of tiles complete all as specified. |
| 12 | M&L Double Charged Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match & including 20 mm thick screed in cement mortar (1:6) and pointed in white/ coloured cement with pigment to match the colour of tiles complete all as specified and directed.. |
| 13 | M&L Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, on vertical surface such as skirting / dado set and jointed in neat cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white/ coloured cement with pigment to match the colour of tiles complete all as specified and directed. |
| 14 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size not exceeding 1.5 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts and removing from site to store or otherwise as directed complete all as specified. |
| 15 | Taking down Shutter exc. 1 sqm and not exc . 2 sqmeach |
| 16 | Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheetreinforced with MS square tube complete all as specified. |
| 17 | Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail MS frame shall be covered with heat moulded plain / coloured PVC \"C\"channel having a PVC sheet strip of20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the styles & rails with suitable PVC sheet beading and jointed togeather with solvent cement complete all as specified. |
| 18 | S&F Stainless Steel Butt hinges, medium weight, 100 mm long complete all as specified and directed. |
| 19 | S&F 150mm long aluminium anodised handle cast type and fixed |
| 20 | S&F in repair aluminium anodized barrel tower bolts of extruded section length of bolt 150mm complete all as specified and directed by Engr-in-charge. |
| 21 | Taking down 15mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specifide. |
| 22 | Taking down 20mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specifide. |
| 23 | S&F 20 mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors includingfittings (Brass elbow, Brass Tee, Malethreaded brass adaptor, Female threaded brass adaptor etc), Unions, complete to make the water supply line functional all as specified. |
| 24 | S&F 20 mm Bore CPVC Ball Valve complete all as specified. |
| 25 | S&F 25 mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors includingfittings (Brass elbow, Brass Tee, Malethreaded brass adaptor, Female threaded brass adaptor etc), Unions, complete to make the water supply line functional all as specifiedcomplete all as specified. |
| 26 | S&F 25 mm Bore CPVC Ball Valve complete all as specified. |
| 27 | Vitreous china squatting pan, Orissa pattern, size 580x440mm white/ coloured with integral foot rests including flush pipe and connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete all as specified. |
| 28 | Vitreous china wash down water closet pan ( pedestal pattern ), white/ coloured including seat & cover, flush pipe, connection to drain and to flushing pipe, anti-syphonage pipe, etc. complete all as specified. |
| 29 | PVC 10 ltr. Cap. valveless syphonic action type, flushing cictern, low level, white/ coloured with inlet, ball valve, float and handle including brackets and connection to pipe etc. all as specified. |
| 30 | S&F in repair bib taps, fancy type CP, screwed for 15mm bore of iron pipe or for brass ferrule and fixed all as specified. |
| 31 | S&F in repair stop valves, fancy type, CP with long shank and cup (concealed type), screwed both ends for 15mm bore of iron pipe or for union and fixed all as specified. |
| 32 | S&F in repair ball valves high pressure of Brass with epoxy coated aluminum rod and high density-plastic ball screwed for iron pipes of 20 mm bore pipe minimum weight 210 Grams cleaning all as specified and directed |
| 33 | Dismantling boarding, any description, fixed in any position with nails |
| 34 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. |
| 35 | M&L Solid PVC Wall Lining consisting of5mm thickwood grain printed PVC sheet inclusive of solvent cement and fixing atsite on PVC frame as per specifications and drawing |
| 36 | M&L 5mm thick PVC sheet fillet of width35mm for wall paneling inclusive offixing on to wall to make PVC Frame asper specification and drawing |