| 1 | Taking down cement plaster on brick or PCC block masonry wall in any description. |
| 2 | M&L for rendering 15mm thick in two layers of first layer 10mm thick in CM (1:6) and second layer 5mm thick rendering in CM (1:4) using water proofing compound (WPC will be paid separatley) on brick masonry or stone block masonry or concrete surfaces. |
| 3 | Supply only water proofing compoundconforming toIS-2645 1975. |
| 4 | M&L rendering 10mm thick in CM (1:6) on internal surfaces of walls of block masonry finished even & smooth without using extra cement. |
| 5 | M&L for rendering to ceiling in 5mm thick on fair faces concrete surface in CM (1:3) finished even and smooth without using extra cement. |
| 6 | M&L for oil bound distempering two coats over a coat of alkali resistant priming paint including preparation of new plastered or unplasteredsurfaces of wall complete all as specified and directed by Engineer - in -Charge. |
| 7 | - Ditto - all as per Item No 6.00 here-in-before but on ceiling |
| 8 | M& L for preparingnewly plasteredwall surfaces and applying two coats of acrylic emulsion based premium quality matt finish exterior antifungal paint over a coat of alkali resistant primer all asper manufacturer\"s instructions complete all as specified and as directed |
| 9 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the rubbies complete all as specified and directed. |
| 10 | M&L Coloured Glazed ceramic tiles in vertical surfaces 350 X250 X7mm / 450X350X 7mm thick as in skirting /dado, set and jointed in cement slurry and pointed in coloured cement to match laid over 10mm thick cement backing coat in CM 1:3 complete all as specified and as directed. |
| 11 | M & L for Non Skid Ceramic Tiles, Coloured, of size exceeding 0.06 Sq.m and not exceeding 0.11 Sq.m, 7 mm to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:6 complete all as specified and as directed. |
| 12 | Demolition ofcementConcrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 13 | M&L for 100 mm thick padding in roof, chajjas and similar work in PCC 1:2:4 type B0 (using 12.5mm graded aggr) with WPC @ 3% by wt , making haunching if required and surface even and smooth with using extra cement including demolition all as specified and directed |
| 14 | M&L PCC1:4:8 D2 (40mm graded aggregate) 100mm thick for paving,sub basepath etc complete all as specified and as directed. |
| 15 | M&L PCC1:2:4B 2 (40mm graded aggregate) 100mm thick for paving,sub basepathcomplete all as specified and as directed. |
| 16 | M & L for Non Skid Ceramic Tiles, Coloured, of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 mm to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed. |
| 17 | S&F in repairs aluminium anodised snap grid false ceiling of standard aluminium section such as wall angle of size 38mm x 25mm x 2.4mm weighing 0.36 Kg/Rm main/cross tees of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/Rm, grid size n.exc. 610 x 610mm suspended with 4mm dia GI wire at interval n.exc. 600mm centre to centre for main & cross tees fixed to roof slab roof truss fixed with suitable size MS hook and fastening bolts etc including \"E\" board classic 4mm thick oceanic sheet of size n.exc. 610 x 610mm size fixed in ceiling with clips to aluminium snap grid incl preparation of new surface and applying two coats of oil bound distemper over a coat of primer all as specified and directed. |
| 18 | S & Fin repairs Aluminium anodised (minimum anodisation is50 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills,necessary joining cleats, glazing clips, rubber packing,anodised aluminium snap beading, screws, handles, locking arrangements etc., complete with standard aluminium sections, complete all as specified and as directed by Engineer-in-charge. (Aluminium section shall be of make Jindal/Hindalco/ Indalco).(Note:- Weight ofvarious Aluminium sections handles and locking arrangementsshall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted. Glass panels, prelaminated particle boards, glass & aluminium wire cloth as applicable will be measured and paid separately as supplied only). |
| 19 | S& F5 mm thick sheet figured glassand glazing with rubber packing around the glass, in squaresexceeding 0.50 sqm in each pane complete all as specified and as directed. |
| 20 | M& L for 12 mm thick Prelaminated particle board, exterior grade prelaminated one side with decorativechoice lamination & other side balancing white lamination fixed with screws to timber frame work |
| 21 | M&L for 18 mm thick HDHMR high quality boardings both side pre laminated, one side(white) and other side coloured and pattern decorative laminates as approved as in kitchen cabinet/shelves/wardrobe/wall panellingfixing with necessary small fitting(screw, liping tape ) etc. as required as per manufacturers instructions complete all as specified and directed ( Make : Greenply/Action Tesa or equivalent) |
| 22 | S&F magnet catch forcupboards, drawer,file rack,of brass body and skirting plate complete all as specified and as directed. |
| 23 | S&F stainless steel auto closing heavy duty modular hinges for cupboard shutter complete all as specified and as directed. |
| 24 | Supply & fix in Repairs aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40 mm complete in repairs complete all as specified and as directed. |
| 25 | Dismantling, Plain or corrugated steel sheeting any gauge hickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 26 | S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws etc complete all as specified and as directed. |
| 27 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws asin ridges, hips, valley gutter, drip, and straight flashing all as specified and as directed. |
| 28 | S & F in repairsAluminium flat iron work in, wind ties screwed including all necessary drilling, bolting or riveting etcand similar work complete all as specified and as directed. |
| 29 | Dismantling wrought iron or mild steelwork of any description not otherwise provided for complete all as specified and as directed. |
| 30 | S&F for Rolled sections/Tubular MS pipes as in cross beams, hip and jack rafters, vertical posts, purlins where connected to common rafters fixed with angle cleats or similar work including welding and all necessery works complete all as specified and as directed.Note : The rates are inclusive of Scaffoldings as required |
| 31 | M&L for Plates (Plain or Chequered) channels, square or notched (Ordinary and counter sunk) forming holes, without any attachment of Fe 290 (Gde E-165) completely all as specified and as directed. |
| 32 | M&L for preparing new or previously untreated surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of redoxide primer all as specified complete all as specified and as directed. |
| 33 | S&F in repair Vitreous China Wash down water closet pan semi pedastel pattern(Anglo-Indian type, EWC) white in colour with and incl plastic water seat and cover white closed pattern with flat bottom and cover and MS chromium plated hinging device incl connection to outgoing pipe and flushing pipe complete all as specified and as directed. |
| 34 | S & F in repairs Vitreous china ware wash hand basin, white, flat back of size 550 mm X 400 mm including 32mm brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand,etc complete all as specified and as directed. |
| 35 | S&F in repair10 litre capacity PVClow level valve less syphonic action type flushing cistern, white, with inlet,ball valve, float and handle including brackets, and 32mm PVC bend complete all as specified and as directed. |
| 36 | S&F in repair CP towel rail 20 mm dia, 60 cm long fixed with CP screws and wood cleats / rowel plug inwall, complete all as specified and as directed. |
| 37 | S & F in repairs 600 mm X 450 mm levelled Edge Mirror of selected quality glass, 5 mm thick, mounted on 6 mm thick AC building board or commercial plywood complete all as specified and as directed. |
| 38 | S & F in repair Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type heavy duty, 15 mm dia, with capstan head, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed. |
| 39 | S & Fin repairs to Bib Taps, cast copper alloy heavy duty, 15 mm dia, Chromium Plated, Fancy Type screwed down for iron pipe and fixed etc complete all as specified and as directed. |
| 40 | S & F in repairs 15 mm dia bore cast copper alloy chromium plated angle cock/stop cock with long shank and cup screwed down high pressure with capstan head, screwed both ends for iron pipes or for union and fixed, complete all as specified and as directed. |
| 41 | S & Fin repairs toTwo way Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type screwed down for iron pipe and fixed etc complete all as specified and as directed. |
| 42 | S&F in repairchromium plated health faucet with 1000mmPVC pipe for 15 mm bore with fittings complete all as specified and directed. |
| 43 | S&F in repairs 32/40mm dia PVC flexible Waste Pipe, 750 mm long fixed to Wash Hand Basin or Sink complete all as specified and directed.. |
| 44 | S&F in Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long of approved quality complete all as specified and as directed. |
| 45 | S&F in repair 100 mm dia CP grating with/without hole incl joints with solvent cement complete all as specified and directed. |
| 46 | M&L for applying one coat of acrylic emulsion weather coat premium quality antifungal exterior emulsion to old painted surface of wall including preparation all as specified and directed |
| 47 | M&L for preparation of old distempered surfaces of walls and applying one coat of oil bound distemper complete all as specified and as directed. |
| 48 | M&Lin repairs20 mm bore unplasticised PVC pipes of pressure rating 10 Kgf/Sqcm fixed complete to walls, ceilings or in floors etc any type of pipe complete all as specified and as directed. |
| 49 | M&Lin repairs25 mm bore unplasticised PVC pipes of pressure rating 10 Kgf/Sqcm fixed complete to walls, ceilings or in floors etc any type of pipe complete all as specified and as directed. |
| 50 | S&F CPVCBrass Elbow 20 mm outer dia complete all as specified and as directed. |
| 51 | S&F CPVCBrass Tee20mm outer dia complete all as specified and as directed. |
| 52 | S&F CPVCBrass Elbow 25 mm outer dia complete all as specified and as directed. |
| 53 | S&F CPVCBrass Tee25 mm outer dia complete all as specified and as directed. |
| 54 | S&F CPVCBrass Union 20 mm outer dia complete all as specified and as directed. |
| 55 | S&F CPVCBrass Union 25 mm outer dia complete all as specified and as directed. |
| 56 | S&F CPVCBrass Elbow(3/4 X ½) 20mm outer dia complete all as specified and as directed. |
| 57 | S&Fin Repairs Vitreous Chaina Urinal, Half stall Long typeof size 315x375x620 mmcolourwhiteincl urinal spearder pf PTMT of any colour for fixing with15 mm dia pipe (minimum weighr 60 gms ) complete all as specified and as directed. |
| 58 | S&F110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,fixedto floors complete all as specified and as directed. |
| 59 | S&F 110mm dia PVC (SWR) bend withoval access door complete all as specified and as directed. |
| 60 | S&F in repair CI cowls 100mm bore of pipe complete all as specified and as directed. |
| 61 | M&L for taking down carefully existing aluminium point wiring (light, fan, socket or power) complete fittings fixture such as switches Ceiling roses, pendents,regulators, sockets etc to be measured separately)unscrewing from Board/outlet boxes, fittings & fixtures such as switches, sockets, ceiling rose lamp holder tube/ceiling fitting, bulk head fittings, tube lights & regulator etc and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed. |
| 62 | M&L for taking down carefully existing old DBs and making good disturbed surfaces of walls to match the existing surfaces complete all as specified and as directed |
| 63 | M&L for taking down unserviceable submain wiring alongwith batten/PVC/steel conduits etc and making good disturbed surfaces of walls/ floors to match the existing surfaces all as specified and as directed. |
| 64 | M&L for point wiring (modular type) with two run of PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm (FRLSH), PVC conduit medium grade/ PVC casing caping and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc)and drawing one run of 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable (FRLSH) as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and as directed by Engr-in-Charge.(In ceiling Portion surface conduit wiring shall be carried out.) Note: The quoted rate inclusive for the following :- (a) GI metal flush box and Modular cover plate with frame of any module complete.(b) Proper colour coding is to be followed as per IS Specification. (c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement. |
| 65 | One light/fan point controlled by one one way switch. |
| 66 | One exhaust/Ceiling fan point controlled by one switch. |
| 67 | One 3 pin socket outlet 5/6 Amps independent. |
| 68 | One 3 pin socket outlet 5 Amps on the same board with other switches |
| 69 | All as per item No 64 above but cable with 4.0 sqmm size for socket outlet 15 amps, independent. |
| 70 | M & L for submain wiring with two single core PVC insulated unsheathed multistranded copper conductor cable of size 6 sqmm (FRLSH) and one single core PVC insulated unsheathed multistranded copper conductor cable green colour of size 6 Sqmm (FRLSH) as earth lead in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification including takind down unserviceable submain wiring complete all as specified and as directed.Note : (i) Three run of cable with one run of PVC conduit/PVC casing and caping will be measured as one length.(ii) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement. |
| 71 | All as per item No 66 here-in-before but with 6 sqmm cable complete all as specified and as directed. |
| 72 | S&F modular switch one way 6 Amps, 1 module complete all as specified and as directed |
| 73 | S&F modular switch one way 16 Amps, 1 module complete all as specified and as directed. |
| 74 | S&F modular socket, 2/3 pin 6/16 amps, 2 module complete all as specified and as directed. |
| 75 | S&F modular socket, 2/3 pin 6 amps, 2 module complete all as specified and as directed. |
| 76 | Supply & fixing ceiling Rose, 3 terminal polycarbonate isolated body complete all as specified and as directed. |
| 77 | Supply & fixing LED light fitting 20W, 2000lm, CDL,4 feet, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 78 | S&F as in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt, >120lm/watt, IP-20, CCT value 4000k to 6500K, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 79 | Supply and fixing LED 18W inverter batten type fitting 3/4 feet long aluminium extruded housing, charging time 10-12 Hrs with 04 Hrs backup,IP-20 ,rated voltage 230 V, 50 hz, system wattage 20W +/- 10%, system current less than 102 mA, power factor more than 0.95, system lumen efficiency 100lm/watt,CCT 6500K, CRI more than 80, THD less than 30%, driver efficiency more than 85% complete all accessories prewiredand connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed. |
| 80 | Supply & fixing BLDC ceiling fan 1200mm sweep with blades, suitable electronic remote as per OEM design, down rods and connected accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM, 5 star rated, equipped with brushless direct current motor (BLDC) of wattage < 28W including provision of cable from ceiling rose/connector to fancomplete all as specified and as directed. |
| 81 | Supply & fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 HZ, RPM 1200, Copper winding of sweep 250mm and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastner including making arrangement to the window of any type and at any height for fixing of exhaust fan and provision of cable from ceiling rose/connector to fan complete all as specified and as directed. |
| 82 | Supply and fixing as in repair LED building security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame with lumen output not less than 2500 lumens suitable wattage for efficiency not less than 120 lumens/watt having secondary optics min wattage 25 watt with ingress protection IP 65/66 and potted electronic driver of minimum IP 67 with THD less than 10% CRI>80, P.F>0.95, CCT 5700K, IK>08 SPD of capacity 10 KV and testing on completion complete all as specified and as directed. complete all as specified and as directed. |
| 83 | M&L for GI bracket for street light fitting made out of 25 mm bore pipe ISI marked light grade GI tube bent to shape required not less than 1.20m long fixed with and including MS flat iron clamps made out of 25x3 mm GI flat, bolts, nuts and washer etc., complete all as specified and as directed. |
| 84 | Supply & fixing MCB DB\"s SPN 8 way, IP-54, IK-09 double door, sheet metal enclosure, 240V, 200 amps rated copper busbarincluding suitable size of copper lugs for fixing of cable complete all as specified and as directed. |
| 85 | Supply and fixing MCB SPN40 to 63 Amps ,10 KA, C Curve, 230 Volts ,50 HZ complete all as specified and as directed. |
| 86 | Supply and fixing MCB SP 6-32 Amps ,10 KA, C Curve, 230 Volts ,50 HZ complete all as specified and as directed. |
| 87 | S&F File Compactor push and full type single bay (height 2180mm, width-915mm) (SS1-1, SL1-1,TM1-2) Make Godrej/Methodex/Geeken) complete all as directed.. |