| 1 | M&L for servicing repair/servicing at site of ceiling fan of any capacity complete incl carrying out lubrication, greasing andto make the ceiling fan noise free and smooth functioing, including replacement of worn out/unserviceable minor spare parts such as split pin,fan body bolts, spring washer, fan rod bolt, capacitor etc assembling theceiling fan and testing to the entire satisfication of user/engineer in charge and refixing the same at site. (Note :- Replacement of Major spares parts except specified above, flexible wire/rewinding of ceiling fan/shall be measured and paid seperately under respective item)Note :- (a) Cost of labour for taking down and refixing of fan after servicing deemed to be included in the quoted rate of this item no extra shall be admissible to the contractor (b)Contractor team will report to AGE E/M Sub Div dailly except sunday and holiday at 0900 Hrs to collect ceiling fan complaints. |
| 2 | All as per item No 1 above but for exhaust fans of any size and capacity (metal body) |
| 3 | All as per item No 1 above but for exhaust fans of any size and capacity (PVC body) |
| 4 | All as per item No 1 above but for wall mounting/air circulator fan of any size and type |
| 5 | Taking down ceiling fans any type/sweep 230 V AC and refixing after cleaning and making connection complete. |
| 6 | M&L for rewinding ofceiling fan, of any make/type and size (1200/1400mm sweep) with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufactures specification, including replacement of all insulationmaterials, varnishing, heating, drying, assembling of stater/rotor, capacitor, connection & testing complete.Note :- Constractor shall setup his workshop at his own arrangement for rewinding of fans in side CME at placedecided by Engineer-in-Charge. |
| 7 | All as per item No 6 above but exhaust fan upto 400 mm sweep working on 230 volts AC supply (metal body) |
| 8 | All as per item No 6 above but exhaust fans upto 300mm sweep working on 230 volts AC supply (PVC body) |
| 9 | All as per item No 6 above but wall mounting/air circulator fan of any sweep working on 230 volts AC supply |
| 10 | Labour for remetalling of worn out shaft of fan , cutting,brazing,machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the engineer satifaction of engineerin charge to ensure smooth and noise free operation (bearing shall be measured and paid seperately ) |
| 11 | Supply only ball bearing of any size and type, suitablefor any type/make/size of ceiling fan complete all as specified and directed. |
| 12 | All as per item No 11 above but for exhaust fan of any type/make and size complete all as specified and directed. |
| 13 | Allas per item No 11 above but for wall mounted fan of any type/Make and size complete all as specified and directed. |
| 14 | S & F in repair fan hanging hook any type or size suitable to hang on wooden block, MS bar etc with rubber reel, nuts, bolts, split pin etc suitable for ceiling fan complete all as specified and as directed by Engr-in-Charge. |
| 15 | Supply and fixing in replacement ceiling fan down rod including drilling, cutting, threading & white painting for ceiling fan 1200/1400mm sweep of length 12\" complete all as specified and directed. |
| 16 | All as per item No 15 above but oflength (18\") complete all as specified and directed. |
| 17 | All as per item No 15 above but oflength (24\") complete all as specified and directed. |
| 18 | All as per item No 15 above but oflength (30\") complete all as specified and directed. |
| 19 | All as per item No 15 above but oflength (36\") complete all as specified and directed. |
| 20 | All as per item No 15 above but oflength (48\") complete all as specified and directed. |
| 21 | All as per item No 15 above but oflength (60\") complete all as specified and directed. |
| 22 | Supply and fix PCB controller suitable for 240 V single phase supply for BLDC fan with PVC cover and all fixing arrangement complete all as specified and directed. |
| 23 | S & F in replacementcanopyfor ceiling fans upper and bottom (Set of two) complete all as specified and directed. |
| 24 | S & F in replacement stepped type ,socket design electronic fan regulator flush type on the existing phenolic laminated sheet etc.suitable for 1200 mm sweep ceiling fan all as specified and directedincl taking down old UNSV one.. |
| 25 | M&L for point wiring for fan/exhaust fan with FRLSH cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/capingwith all accessories and 1.50 sqmm green in colour PVC copper conductor cable for earth continuity connected to common earth dolly inclPVC box surface/ flush type with PVC sheet for mounting fittings such as switches, sockets, fan regulators,etc complete all as specified and directed for one fan/ exhaust fan point controlled by one switch & making goodto disturbed surface of wall etc |
| 26 | S&F in replacement modular fan regulator step type 120W, 2 module with suitable plate and cover complete as per existing make and model all as specificed and directed. |
| 27 | S&F in replacement louver shutter made out of MS sheet metal 1.2 mm thick for exhaust fan upto 400 mm size round or square as per site condition including fixing arrangement with fixing material complete all as specifed and directed. |
| 28 | Supply and fix in replacement PVC terminal connector complete all as specified and directed. |
| 29 | S & F only capacitor 2.5 mfd 230 volts complete all as specified and directed. |
| 30 | Supply only capacitor 4 mfd 230 volts complete all as specified and directed. |
| 31 | Supply and fixing of GI/ MS anodized bolts with anodized nuts, spring washers, split pin etc size 50 mm long 10 mm dia half threaded typewith split pin hole complete all as specified and directed. |
| 32 | S&F in replacement of fan blade of three pieces suitable for 1200mm dia ceiling fan complete all as specified and directed. |
| 33 | S&F in replacement of fan blade suitable for upto 300 mm dia PVC exhaust fan complete all as specified and directed. |
| 34 | S&F in replacement ofPVC fan blade suitable for wall mounted fan upto 600mm dia complete all as specified and directed. |
| 35 | Taking down and refixing ceiling fan after replacement of fan rod with anti suicide fan rod (12\") white, MS pipe zinc plated, 19mm OD, 1.8+/-0.05mm thick, spring set grade 3 carbon steel material zinc plated, MSME tested for performance test and opening at impact load of 22 Kgf and above and spring hidden in the pipe will expand to about 1 mtr or more complete all as specified and directed. |
| 36 | All as per item No 35 above but oflength (18\") complete all as specified and directed. |
| 37 | All as per item No 35 above but oflength (24\") complete all as specified and directed. |
| 38 | All as per item No 35 above but oflength (30\") complete all as specified and directed. |
| 39 | All as per item No 35 above but oflength (36\") complete all as specified and directed. |
| 40 | Supply and connection of PVC insulated, unsheathed multi stranded,three core twisted copper flexible cable of size 1.5 Sqmm as required. . |
| 41 | M&L for spray painting of ceiling fan with first quality synthetic enamelled paint of approved colour all as directed and specified. |
| 42 | All as per item No. 41 above but for exhaust fan upto 450 mm complete all as specified and directed. |
| 43 | Repair to oscillation moving part of wall mounted fan including replacement of all wornout components, bearing , lubricationand assembling complete. |