| 1 | Manning ang Operation for 03 Electrician (Skilled) for 22KV substation services to run theElectric supply installations in 3 shift per day with 01 Electrician (Skilled) per shift at various location such as Sub Station No.9 under GE(I)Lonavla for the operatedElectrical eqpt/ HT< pannels/VCB Panel/GOD/RMU/APFC panel/street light box with DG set for Street light and all type HT< supply line etc.including Sunday /Holidays.Operating the ,Electric supply panels, street light pannels,APFC pannel,recording for voltage, Amp reading, availablity etc daily in Log sheet.and cleaning ofinstallation daily also andattend internal and externalcomplaints as per direction of engr-in-charge and daily basis generate emergency (No light & fire) complete by user, all as specified and directed by Engineer-in-Charge. 01)-shift -0600 Hrs to 1400 Hrs02)-shift -1400 Hrs to 2200 Hrs03)-shift -2200 Hrs to 0600 Hrs |
| 2 | NOTE FOR ITEM NO 1:- Rates quoted by the contractorshall be inclusive for the following items :- (a) Contractor shall provide two set of uniform, shoe with name plate,etc (b)The log sheets will be maintained by the contractor in each installations contractor shall provide log book, Attendance register , plant running record book , and rate quotated by the contractor shall deeed to be included this quotated rate. (c)The site documents such as Log sheet, Attendance etc will be checked daily by JE, Weekly by Engineer in charge & Monthly by GE. (d) All installation and machinery equipement and other items belonging to the E&M installtion including safety shall be responseiblity of manpower employed by the contractor.(e) minor stores required shoulded be provided by the contractor.(f) Major stores required for rectification of complaints will be supplied by contractor as per schedule part- A items. (g) Break down or Shutdown fault creat by HT fault / LT fault on cable line or E&M installation,Fault will be resloved by contractor within 1-2 Hrs at day or Night in presence of E-in charge otherwiseaction will be takenagianst contractor by department and If contractorc is not given any response within one hours of any break down than department will be applied Rs 5000.00 charges every per hours after not respons by the contraactor. (g) Contractor shall provide the all type ofT & P,vehicle,ledder,grass cutting machine and saftey items such as electric proofshooes and hand gloves,body harnese/safetybeltto electricianfor attending & rectification the internal / external electric complaints. (h) The contracror will be responsible for up keep the installations in neat and tidy condition and in a presentable manner . The surrounding of the installations/2pole/4pole structure area with grass/tree cutting as routing basiswill also be maintained neat and clean grasseegation. The qoted rates shall include the up keep of surrounding area the installation out side pherifery up to 06 mtr/ installations grass/ shurb cutting & plantation of seassonal flowers to an area of entire installations and in case the contractor fails to upkeep the the installations , he shall be liable to penalty @ Rs 500 per day for not up keep of the installations.(j) The rate quoted for items of outsourcing shall not be less than minimum wages as notified by Government of India/ Concerner state /Local body , which ever is higher also not less than applicable rates for contribution of employee towards Employees provident Fund (EPF), contribution towards Employees state Insurances corporation (ESIC), contribution of bonus and labour welfare cess (LWC) under respective headings/sub-items . |
| 3 | Repair/maintance of switch air break & DO switch , gang operated triple pole mechanically operated mounted on insulator and steel frame with 9 insulators of 22 KV rating upto 400 amps with operating mechanism worked from ground level for current rating upto 400 amps 22 KV working pressure complete,below maition all work rate are deemed including this rate Note: 1) All rusted /non oprated nut bolt replace 2) GOD oprated handle to be welded as per requirment. 3) oprated rod as per requirment replace orto be welded. 4) connected acessories with AB & DO switch as per requirment repair/replace. 5) all GOD acessories greaseing and alliment done as per requirment.6) Jumper/cable lux replace and refixing with copper lux and brass nut bolts as per site requirment. |
| 4 | Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. |
| 5 | M&L for Scrubing of existing rusted surface of poles 11 mtr longand prepration and painting of surfaceswith one coat of red oxide and two coat aliminium paint fine finishing includign cross arms bracing , clampsand supports complete all as specified and as directed by Engineer-in-Charge. |
| 6 | S&F HT 22 KV Barrel fusesof capacity 60 Amps complete all as specified and as directed by Engineer-in-Charge. |
| 7 | All as per Item No 5 here-in-before but for 30 Amp |
| 8 | All as per Item No 5 here-in-beforebut for 25 Amp |
| 9 | All as per Item No 5 here-in-beforebut for 20 Amp |
| 10 | All as per Item No 5 here-in-before but for 15 Amp |
| 11 | All as per Item No 5 here-in-beforebut for 10 Amp |
| 12 | All as per Item No 5 here-in-beforebut for 5 Amp |
| 13 | S&F plastic polythene sheet 6feet x 8 feet (200 GSM) UV protected water & dust proof transparent for cover for indoor/outdoor panel,E&M installationcomplete all as specified and as directed by Engineer-in-Charge. |
| 14 | M&L for defect rectification HT/LT cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additionalexcavation in normal alluvial strata required forexposing the cable fault ; removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of size up to 240 Sq mm 3 core & LT cable of size upto 240 Sqmm. The fault locating equipments will be brought to site within the hours of instruction from by Engineer-in-Charge as specified |
| 15 | M & L for dismantling22 KV VCB Panel (06 nos) (01 I/C +04 OG with 01 independent panel)to carry out repairs and replacementof worn out spare parts including servicing/ testing/calibration of relays and taking out defective Part of 22 kv VCB 800/1250Amp of any make type and servicingof VCB by cleaning isolating contacts, moving parts removing dust particles from busbar chamber spout, gear mechanism and moving parts, check and repairing spring charging motor with gear assembly, tighting of nut bolts of entire trolley components all as directed inserting in trolley also checking all mechanical and electrical parts with wiring if any problem rectify it ,after work test High voltage test of VCB pole by Vidar with standard as per specified. (a) Checking of Mechanically and electrically full operation (b) Check and repair/replacement faulty part of VCB. (c) Full Breakproperly overhauling ,servicing with smooth opertation as Engineer direction. (d) Mechanism servicing and lubrication (e) Control wiringrepairing and tightness. (f) Power connection tightness (g) Check vaccume interrupter by HVtest kit or Vidar test kit. (h) Check contact resistance measurement.(i) Check insulation resistance test(j) High voltage testing of VCB. (k) Submission of test report in standard format of vacuum circuit breaker. (L) Check coil resistance(M) Remove moisture of front side of vcb and bus duct back side of vcb with heating all panel by hot air gun.(n) Busbar rapping by HV tape or HT Sleave. Note : 1) All test certificate and defect list provide by contractor.2) If After repair/replace or maintance, any defecte creat in VCB panel than contrector resovedefect without any cost tillcompletion date done this work. (3) VCB panel service and any type fault done/resolved byonlyMSEDL or ABB Company authorised company/Dealers and its authorised certificate provide by contractors.Location:-Main Receiving Station(MRS) |
| 16 | M & L for dismantling22 KV VCB Panel (03 nos) (01 I/C +02 OG panel)to carry out repairs and replacementof worn out spare parts including servicing/ testing/calibration of relays and taking out defective Part of 22 kv VCB 800/1250Amp of any make type and servicingof VCB by cleaning isolating contacts, moving parts removing dust particles from busbar chamber spout, gear mechanism and moving parts, check and repairing spring charging motor with gear assembly, tighting of nut bolts of entire trolley components all as directed inserting in trolley also checking all mechanical and electrical parts with wiring if any problem rectify it ,after work test High voltage test of VCB pole by Vidar with standard as per specified a) Checking of Mechanically and electrically full operationb) Check and repair/replacement faulty part of VCB c) Full Breakproperly overhauling ,servicing with smooth opertation as Engineer direction d) Mechanism servicing and lubrication e) Control wiringrepairing and tightness f) Power connection tightness g) Check vaccume interrupter by HVtest kit or Vidar test kith) Check contact resistance measurement i) Check insulation resistance testj) High voltage testing of VCB k) Submission of test report in standard format of vacuum circuit breaker.L) Check coil resistance M) Remove moisture of front side of vcb and bus duct back side of vcb with heating all panel by hot air gun n) Busbar rapping by HV tape or HT SleaveNote : 1) All test certificate and defect list provide by contractor2) If After repair/replace or maintance, any defecte creat in VCB panel than contrector resovedefect without any cost tillcompletion date done this work. (3) VCB panel service and any type fault done/resolved byonlyMSEDL or ABB Company authorised compny/Dealers and its authorised certificate provide by contractors.Location:-Nearby Gas Godown |
| 17 | M & L for dismantling22 KV VCB Panel (03 nos) (01 I/C +02 OG panel)to carry out repairs and replacementof worn out spare parts including servicing/ testing/calibration of relays and taking out defective Part of 22 kv VCB 800/1250Amp of any make type and servicingof VCB by cleaning isolating contacts, moving parts removing dust particles from busbar chamber spout, gear mechanism and moving parts, check and repairing spring charging motor with gear assembly, tighting of nut bolts of entire trolley components all as directed inserting in trolley also checking all mechanical and electrical parts with wiring if any problem rectify it ,after work test High voltage test of VCB pole by Vidar with standard as per specified a) Checking of Mechanically and electrically full operationb) Check and repair/replacement faulty part of VCB c) Full Breakproperly overhauling ,servicing with smooth opertation as Engineer direction d) Mechanism servicing and lubrication e) Control wiringrepairing and tightness f) Power connection tightness g) Check vaccume interrupter by HVtest kit or Vidar test kith) Check contact resistance measurement i) Check insulation resistance testj) High voltage testing of VCB k) Submission of test report in standard format of vacuum circuit breaker.L) Check coil resistance M) Remove moisture of front side of vcb and bus duct back side of vcb with heating all panel by hot air gun n) Busbar rapping by HV tape or HT SleaveNote : 1) All test certificate and defect list provide by contractor2) If After repair/replace or maintance, any defecte creat in VCB panel than contrector resovedefect without any cost tillcompletion date done this work. (3) VCB panel service and any type fault done/resolved byonlyMSEDL or ABB Company authorised compny/Dealers and its authorised certificate provide by contractors.Location:-Nearby KV School |
| 18 | M & L for dismantling22 KV VCB Panel (04 nos) (01 I/C + 03 OG panel)to carry out repairs and replacementof worn out spare parts including servicing/ testing/calibration of relays and taking out defective Part of 22 kv VCB 800/1250Amp of any make type and servicingof VCB by cleaning isolating contacts, moving parts removing dust particles from busbar chamber spout, gear mechanism and moving parts, check and repairing spring charging motor with gear assembly, tighting of nut bolts of entire trolley components all as directed inserting in trolley also checking all mechanical and electrical parts with wiring if any problem rectify it ,after work test High voltage test of VCB pole by Vidar with standard as per specified a) Checking of Mechanically and electrically full operationb) Check and repair/replacement faulty part of VCB c) Full Breakproperly overhauling ,servicing with smooth opertation as Engineer direction d) Mechanism servicing and lubrication e) Control wiringrepairing and tightness f) Power connection tightness g) Check vaccume interrupter by HVtest kit or Vidar test kith) Check contact resistance measurement i) Check insulation resistance testj) High voltage testing of VCB k) Submission of test report in standard format of vacuum circuit breaker.L) Check coil resistance M) Remove moisture of front side of vcb and bus duct back side of vcb with heating all panel by hot air gun n) Busbar rapping by HV tape or HT SleaveNote : 1) All test certificate and defect list provide by contractor2) If After repair/replace or maintance, any defecte creat in VCB panel than contrector resovedefect without any cost tillcompletion date done this work. (3) VCB panel service and any type fault done/resolved byonlyMSEDL or ABB Company authorised compny/Dealers and its authorised certificate provide by contractors.Location:-Solar Power Plant |
| 19 | M & L for dismantling22 KV VCB Panel (01 nos) (01 I/C panel)to carry out repairs and replacementof worn out spare parts including servicing/ testing/calibration of relays and taking out defective Part of 22 kv VCB 800/1250Amp of any make type and servicingof VCB by cleaning isolating contacts, moving parts removing dust particles from busbar chamber spout, gear mechanism and moving parts, check and repairing spring charging motor with gear assembly, tighting of nut bolts of entire trolley components all as directed inserting in trolley also checking all mechanical and electrical parts with wiring if any problem rectify it ,after work test High voltage test of VCB pole by Vidar with standard as per specified a) Checking of Mechanically and electrically full operationb) Check and repair/replacement faulty part of VCB c) Full Breakproperly overhauling ,servicing with smooth opertation as Engineer direction d) Mechanism servicing and lubrication e) Control wiringrepairing and tightness f) Power connection tightness g) Check vaccume interrupter by HVtest kit or Vidar test kith) Check contact resistance measurement i) Check insulation resistance testj) High voltage testing of VCB k) Submission of test report in standard format of vacuum circuit breaker.L) Check coil resistance M) Remove moisture of front side of vcb and bus duct back side of vcb with heating all panel by hot air gun n) Busbar rapping by HV tape or HT SleaveNote : 1) All test certificate and defect list provide by contractor2) If After repair/replace or maintance, any defecte creat in VCB panel than contrector resovedefect without any cost tillcompletion date done this work. (3) VCB panel service and any type fault done/resolved byonlyMSEDL or ABB Company authorised compny/Dealers and its authorised certificate provide by contractors.Location:-MRS(Main VCB Panel) |
| 20 | M & L for Calibration presses and injector testcarried out of06 VCB panel\"s allcurrent transformer & potentialtransformer including of primary/secondary injection by using testing transformer monitored withstanding capacity of CT& PT all as specification as directeda) Cleaning and checking CT primary terminals and remove moisture and connection tightness Primary and secondaryb) Checkingprimary ratio ,polarity,CT knee point Volt.burden check,% error ,winding restance.c) Insulation resistance test with all coreD) Relay tripping throw CT primary injection test e)Check control wiring of on relay and meter with tightness f) Power and control connection tightness g) repairing faulty wiring h) Submission of test report in standard format of vacuum circuit breaker.i) Rectify CT proper connection Protection and metering core Note : 1) All test certificate and defect list provide by contractor 2) If After repair/replace or maintance, any defecte creat in VCB panel than contrector resovedefect without any cost tillcompletion date done this work. |
| 21 | Supply and fixin Replacement of LED Indicator 22.5mm dia replaced by old indicator (Colour-Red, Green,Yellow,Amber) Complete all as specified and directed by Engineer-In-Charge. |
| 22 | Supply and fixin Replacement of LED Indicator 22.5mm dia replaced by old indicator(Colour-Blue,White), Complete all as specified and directed by Engineer-In-Charge. |
| 23 | Supply and fixin Replacement of flush head type push button replaced by old damage push button, Complete all as specified and directed by Engineer-In-Charge. |
| 24 | Supply and fixin Replacement of Digital multifunction meter (V, A, F, PF) replaced by damage one, Complete all as specified and directed by Engineer-In-Charge. |
| 25 | Supply and fixin Replacement of Isolator switches(ON-OFF switches) replaced by damage one, Complete all as specified and directed by Engineer-In-Charge. |
| 26 | Supply and fixin Replacement of Selector Actuators 22.5mm dia,symmetrical head,3 position replaced by damage one, Complete all as specified and directed by Engineer-In-Charge. |
| 27 | Supply and fixin Replacement of Rotary Handle replaced by damage one, Complete all as specified and directed by Engineer-In-Charge. |
| 28 | Supply and fixin Replacement ofdisplay/relay unit computerised control of Power Factor Digital type 12 steps 440 V, Complete all as specified and directed by Engineer-In-Charge. |
| 29 | Supply and fixing in Replacement Ammeter for HTof 22 KV VCB Panel (Make :ABB) complete all as specified and as directed by Engineer-in-Charge. |
| 30 | Supply and fixing in Replacement spring charge motorof 22 KV VCB Panel(MAKE:ABB)complete all as specified and as directed by Engineer-in-Charge. |
| 31 | Supply and fixing in Replacement closing coilof 22 KV VCB Panel (Make:ABB)complete all as specified and as directed by Engineer-in-Charge. |
| 32 | Supply and fixing in Replacement Triping coilof 22 KV VCB Panel (Make:ABB)complete all as specified and as directed by Engineer-in-Charge. |
| 33 | Supply and fixing in Replacement Tulip contacts (14 Fingers)of 22 KV VCB Panel (Make:ABB)complete all as specified and as directed by Engineer-in-Charge. |
| 34 | Supply only Bus Bar tapeof 22 KV VCB Panelcomplete all as specified and as directed by Engineer-in-Charge. |
| 35 | S&F Digital. Ammeter (1 phase) make-elmeasure 1/5Acomplete all as specified and as directed by Engineer-in-Charge. |
| 36 | S&F Digital Ammeter ( 3 phase) make-elmeasure 1/5Acomplete all as specified and as directed by Engineer-in-Charge. |
| 37 | S&F Power Pack- SMPS base with battery backup Input V-230v AC, Output- 24v Dc. |
| 38 | S &F Space Heater-230vAc,200w as per direction of by Engineer-in-Charge |
| 39 | Supplying and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. |
| 40 | M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.’25 mtr below normal ground level) with top edge of the plate not less 1.5 mtr below normal ground level connected to galvanized earth plate using galvanised iron strip 25×4 mm as earthing lead by means of suitable size of GI nuts, bolts, check nuts and washers all as specified in electrical plate SSR Part I including necessary .Exc & earth work, providing charcoal and salt dust layers and construction of PCC pit in 1:3:6 using 20 mm size graded stone aggregate, precast RCC 40 mm thick cover in 1:2:4 type B 1 with 12 mm dia steel MS plain bar, lifting handle GI pipe of 50 mm bore for earth lead protection andGI pipe 15 mm dia forwatering, with funnel and wire mesh including testing on completion. |
| 41 | Supply & installation of Earthing rods as per following specifications (a) Earthing rod 25mm pur copper hollow Earthing Rod with strip I Pipe Design ,length 3 m.Copper Terminal of 100x50x5.(b) BFC Compound The BFC is carbide based having very high electrical conductivity. BFC having high moisture retaining capacity, BFC is hygroscopic,nonmagnetic and non-corrosive in nature and in ROHS compliant(c) Installation The Earthing electrode will be placed in the ground after a bore is drilled to the depth of 3.5m.the Bore drilling will be done with the help of pneumatic boring machine. 50KG BFC will be placed in the bore to cover the Earthing rod from all sides.Earth pit cover sqaure 300x300x24mm to be provided to cover the Earth pit. The Earth pit cover shall be made of Reinforced FRP and should be capable of carrying the weight of 5 tonns.Make : U-Protect,Ashok,JEFT Techno.Note:-(1) Electrode must be tested for short circuit test of minimum 40KA at CPRI/NABL . (2) After installation company testing & checked test with earth value certificate provide by contractor. |