| Sl. No. | Item Description |
| 1 | Dismantling of brick tiles or concrete tiles single layers on roof and rubbish off the premises to a distance not exceeding500 mtr including stacking of servicable brick tiles complete all as specified and as directed. |
| 2 | Demolition of mud phuska on roofs, any thickness including mud plastering,whether full thickness removed or only a part thereof and rubbish off the premises to a distance not exceeding500 mtr complete all as specified and as directed. |
| 3 | Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry @ 3.0 Kg/Sqm complete all as specified and as directed |
| 4 | M&L for PCC 1:2:4 type B-0 using 12.5mm graded mechanically crushed stone aggregatesas in padding on roof to maintain the required slope & finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 5 | M&L Hydraulically pressed Cement Concretetiles plain size 250x250x19 mm/300x300x19 mm laid over and including 15mm thick screed in CM 1:4 with WPC & pointed in CM1:3 mixed with crude oil ( WPC as per manufacturer\"s instruction shall be deemed to be included in unit rate quoted)complete all as specified and as directed.Note :- water proofing treatment will be carried out through approved applicator as approved by GE. |
| 6 | M&L for APP polymeric water proofing treatement to roof, at any height, using membrane minimum 3 mm thick and weighing not less than 3.6 kg per sqm , black finish reinforced with non-woven polyster matt weighting not less than 150 gms per sqmwith thermo fusible finish laid by force application after applying compatible bitumen primer at the rate of 0.40 Ltr per Sqm, torching over laps with a propane orbutane gas torch with a over lap of 100 mm at the side on transverse direction and 150 mm at the ends on longitudinal directionand sealing including a tack coat of hot blown bitumen 85/25 @ 1.2 Kg per sqm below APP tucking into parapet walls, cut out neatly a horizontal groove 6.5cmm deep, 7.5cm wide section with lower edge at not less than 15cm above the graded roof surface and groove shall be finished smooth with cement mortar 1:4 with WPC @3% by weight of cement where the parapet wall height is 45cm or less no groove will be required as the water proofing treatment will be carried over the top of parapet wall to its full thickness including 15mm thick screed bed in CM 1:4 with WPC @3% by weight of cement, complete all as specified and as directed . Notes:-(i) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing. (ii)5% amount of the total amount of water proofing treatment shall be retained as a guarantee (on account of any defect raised/noticed during a period of ten years) and shall be released after 10 years of completion of work. However contractor may deposit the FDR of same amount in favour of GE. If contractor fails to rectify the defect pointed out during this period , the defect shall be got rectified at contractor\"s risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. The contractor\"s quoted rates for this item shall deemed to be inclusive of this aspect.(iii) Cost of WPC shall be deemed to be included in the quoted rate. |
| 7 | Demolition of Brickwork or stone boulder masonry/PCC block masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework & precast concrete articles and disposing off rubbish outside MD land complete all as specified and directed. |
| 8 | M&L for brick work with sub class Bbricks, straight or curved on plan exceeding 6 m meanradius , built in cement mortor 1:6 complete all as specified and directed. |
| 9 | M&L for brick work with sub class\"B\" bricks,straight or curved on plan to any radius in half brick thick wall built in CM 1:4. complete all as specified and as directed. |
| 10 | Taking down cement plastering of any thickness on brick, concrete or stone walls, partitions, ceilings etc including raking out joints, hacking for key, scrubbing down with water etc, and removing debris out side MD land complete all as specified and as directed. |
| 11 | M&L for 15 mm thick rendering on brick wall or concrete wallorany surface in cement mortar 1:6 on fair face/other than fair face and finishing the surface with even and smooth without using extra cement all as specified and as directed. |
| 12 | M&L for Rendering 15mm thick on fair face/other than fair face of brick work or concrete any surface in CM 1:4 finished even and smooth without using extra cement upto triple storey building, mixing with approved water proofing compound, for roof facia, chajjas, etc.and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed. NOTE:-(i) Height of the bldgs is Appx Up to 12 mtr incl Quoted Rates. cost of necessary scaffolding and security provision of labour shall be deemed to be included in the quoted rate. (ii) WPC will be measured and paid separately as supply only under relevant item of BOQ. |
| 13 | M&L for 5mm thick rendering on ceilings in cement mortar 1:3 and finishing the surface with even and smooth without using extra cement all as specified and as directed. |
| 14 | M & L for rough cast plaster incl 15 mm thick CM 1:3 on brick work or concrete surface complete all as specified in SSR Part -1 clause 14.22 complete all as specified . Note:Rough cast plaster finish shall be as follow :- After applying the under coat cement mortar 1:3 and while it is still inplastic state the rough cast mixture consisting of crushed stone or fine gravel aggreagte ( Which is generally of size between 6 to 12 mm depanding on the texture required mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even . The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure the larger aggregate are throughly covered. Note : i) Area to be plastered may require to be carried out up to height of 15 m. cost of necessary scaffolding required security provision of labour shall deemed to be included in rate quoted against this item. |
| 15 | M&L for Preparation of new or previously untreated plastered wall surfaces of any description not otherwise described and applying two coats of oil bound distemper over a coat of alkali resistant primer over and including 1 mm thick wall care putty, complete all as specified and as directed.Note : Quoted rate shall deemed to include for cost of wall care putty. |
| 16 | M&L for preparation of new plastered surfaces and applying three coats of white wash on ceilings complete all as specified and directed |
| 17 | M&L for Preparation of newly plastered sufaces of walls and applying two coats of weather-proof antifungal exterior emulsion paint over a coat of alkali resistant primer,over wall carePuttyupto triple storey building, complete all as specified and directed. Notes: Item may be executed upto a height of 15.00m cost of necessary scafolding and security provision of labour shall be deemed to be included in the quoted rate. |
| 18 | M & L for applying two coats of cement based paint on newly plastered or unplastered wall surface including preparation ofsurfaces, complete all as specified and as directed. |
| 19 | Taking down cement plaster and decayed concrete of any description, upto triple storey of building,Material & Labour for repair to chajjas/ roof projection with plain cement concrete 1:2:4 type B-0 using 12.5 mm graded mechanically crushed stone aggregates and dubbing out with 20 mm avereage thickness including necessary form work after taking down/ demolition of loose portion/ part/ particles& rendering with 5 mm thick in cement mortar 1:3and finishing the exposed surfaces even & smooth using extra cement complete all as specified and as directed.Note:(i) Cost of WPC shall be deemed to be included in the quoted rate.(ii) Item may be executed upto height of 15.00 metres.(iii)Cost of necessary scaffolding, formwork and security provision of labour shall be deemed to be included in the quoted rate. |
| 20 | Supply onlyliquid water proofing compound complete all as specified and as directed. |
| 21 | Dismantling offloor, hearth or wall tiling including cement mortar bedding (including backing), removing serviceable tiles and disposing off debris to outside the MOD land all as specified and as directed. |
| 22 | M&L for Non-skid joint free coloured ceramic tiles 7 to 8 mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18sqm, as in floor set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigment to match colour of tiles over and including 15mm thick screed bed of CM 1:6 complete all as specified and as directed. |
| 23 | S & F glazed ceramic coloured printed tiles of size 450 x 300X 7mm as in dado set andjointedin neat cement slurry & pointedin white cement mixed with pigment to match with color of tiles over and including10 mm thick rendering in cement motor 1:3all as specified and as directed. |
| 24 | All as per BOQ item No. 23.00 here inabove but in vertical surfaces with backing coat of 10 mm thick other than fair faces of wall in CM 1:4complete all as specified and as directed. |
| 25 | M&L for Vitrified tiles flooring with Light shade 10 mm thick (Square / rectangular), tiles, area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15 mm thick screed bed in CM (1:6) complete all as specified and as directed. |
| 26 | M&L, for Vitrified tile, skirting/dado, light shade with 10 mm thick tiles of area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, on vertical rates as in skirting, dado, etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including backing coat of 10 mm thick CM 1:3 complete all as specified and as directed. |
| 27 | Dismanting Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 28 | M&L for 12 mm thick Gypsum board false ceiling of size 605x605 mm fixed with Anodised aluminium snap grid frame workfor false ceiling , size of grid 605x605 mm incl hanger 6mm dia (up to 1200mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long complete all as specified and directed by the E- IN - Charge . |
| 29 | S & F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall and complete all as specified and as directed. |
| 30 | S & F Solid PVC Wall Lining consisting of 5mm thick Plain colour / Dark colourPVC sheet inclusive of solvent cement and fixing at site on PVC frame as approved complete all as specified and as directed. |
| 31 | Demolitionof cement concrete in ground floor and paving not exceeding15cm below or above ground level removing debris outside MD landcomplete all as specified and as directed. |
| 32 | M&L for 75mm thick PCC type D-2, (1:4:8) using 40mm graded stone aggregate as in sub base of paving/Inter Locking , Hard standing Etccomplete all as specified and as directed. |
| 33 | M&L for 25 mm thick PCC 1 : 2 : 4 type B0 (using 12.50 mm graded mechanically crushed stone aggregate) as in subfloor roughto receive tile screed/bedding layercomplete all as specified and directed |
| 34 | M&L for 40 mmthickness PCC 1:2:4 type B0 using 12.5 mm graded mechanically crushed stone aggregates as in floor finished even and smooth without using extra cementcomplete all as specified and directed. |
| 35 | M&L for 60mm thick machine pressed rubber mouldedprecast concreteM-35 interlocking colouredpaver block any shape and size conforming to IS-15658-2006 withgrey cement and pigment including taking down of old paver blockcomplete all as specified and as directed. |
| 36 | M&L for Sand filling under floorsincluding wateringand consolidation complete all as specified and as directed.. |
| 37 | M&L for Chequered coloured cement concrete commercial Tiles 25CMX25CMX22mm /30cm x 30cm x 20 to 22mm thick of with grey cement andpigmentsetjointed and pointed in neat cement slurry in floors and cut and polished laid and over 15mm Screed in CM 1:4 complete all as specified and as directed. |
| 38 | M&L for 75mm thick PCC (1:3:6) type C-1 using 20mm graded mechanically crushedstone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mt centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and as directed.Notes :- (i) The unit rate quoted shall be deemed to include for providing the concrete in alternate bays not exceeding 3 Mtrs length,10 mm wide. (ii)30 mm deep joints between the bays shall be provided which shall be filled with mastic filling with hot bitumen 85/25 grade and 1:2 mix volume. |
| 39 | M&L for cement concrete 1:2:4 type B-0 ( using 12.5 mm graded mechanically crushed stone aggregate ) as in coping,kerbfor water trough and the like including weathering , slightly rounded or chamfered agle and throating etc incl necessary form work etc complete all as specified and directed |
| 40 | M&L for 100 mm thick plain cement concrete 1 : 2 : 4 type B1 (using 20 mm graded mechanically crushed stone aggregate) as in hard standing laid in pannels including necessary form work,finishedby spike rollingsurfaces of concretecomplete all as specified and as directed |
| 41 | Demolition of cement concrete of any description and any position not otherwise specifically provided for. and disposing off debris to outside the MOD land complete all as specified and as directed. |
| 42 | M&L for for carrying out water proofing treatment of sunken floor as under:-(i)The concrete/ wall surface shall be cleaned throughly of all laitance , loose particles, dust , grease etc. any friable unsound area shall be chipped, cleaned and there after pre-welted to a saturated surface dried conditions.(ii) In case of potholes , superficial cracks found , the same shall be repaired with polymer modified mortar 1:3 ( 1 cement and 3 coarse sand )using Dr fixit pidicrete URP 301/Sikka latex or equivalent in Asian paints/ Forsoc as admixture @ 10% of cement content and the same shall be applied on vertical area after removing of plaster upto 2 ft height (iii)On the prepared surface , apply a primer coat of Sika latex / Dr. fixit pidicrete URP 301 or equivalent in Asian paints/ Forsocmodified cement slurry 1:4:8 (1 admixture : 4 water : 8 cement) , after prewetting the substrate @ 2 kg/sqm .(iv)the surface thus prepared shall dampen upto saturation and apply two coats of sika top seal 107 or equivalent in Dr fixit piddilite/Asian paints/forsoc ,acrylic modified water proofing coating on the entire area @1.5 kg/sqm (each coat) Scond coat shall be applied after 6-8 hrs after the first coat and in the direction right angle to the previous coat . the water proofing should be taken to a vertical height of minimum 600 mm above .(v) Apply open woven glass fiber mesh of sika Fab 1 or equivalent in Dr fixit piddilite/Asian paints/forsoc, 150 mm wide strip over the PCC benching (Gola) whilst the first coat is wet and then apply scond coat . cure the hydrosentapplication ( Minimum 6-8 hrs drying) for a minimum 3 to 5 days .(vi)Apply a protection layer of 10 mm thick plaster made of 1:4 cement sand mortar admixed with integral water proofing compound Sika plastocrete plus/ Dr fixit piddilite LW plus or equivalent in asian paints/ forsoc @ 200 ml/bag of cement , applied over the water proofing coating . complete all as specified and directed. Notes:-(i) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing. (ii)5% amount of the total amount of water proofing treatment shall be retained as a guarantee (on account of any defect raised/noticed during a period of ten years) and shall be released after 10 years of completion of work. However contractor may deposit the FDR of same amount in favour of GE. If contractor fails to rectify the defect pointed out during this period , the defect shall be got rectified at contractor\"s risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. The contractor\"s quoted rates for this item shall deemed to be inclusive of this aspect.(iii) Cost of WPC shall be deemed to be included in the quoted rate.. |
| 43 | M&L for Plain Cement Concrete (1:5:10) type E2, using 40 mm graded mechanically crushed stone aggregate as in sunken slab filling, mass concrete etc., complete all as specified and as directed. |
| 44 | S&F mild steel door shutter two leaves made out of 0.80 mm MS sheet, all round with frame of angle or other sections with gusset plates, rails braces etc , and leaves of 21 gauge MS sheet as per godrej pattern , with three way of locking arrangement with and including brass lock with duplicate keys , steel CP handle 200 mm long , drilled for fixing of steel sheeting or other covering door etc complete conforming to Fe 410-00 (Gde E-250) quality \"A\" including one shop coat of red oxide primer over two coats of spray painting door with frame complete all as specified and directed. |
| 45 | S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or FE 310-0, complete all as specified and as directed. |
| 46 | M&L for Cutting holes brick walls built in cement mortar exceeding half brick thick wall but not exceeding one brick thick wallbuilt in cement mortar for inserting hold fasts etc and making good the dismantled portion in plain cement concrete 1:2:4 type B1 & finished to match as per the existing finish complete all as specified and as directed. Note:- This item shall not be operated if hold fast holes are required at new location. |
| 47 | S & F 250 mm long (Length of bolt) mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed. |
| 48 | S & F 250 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed complete all as specified and directed. |
| 49 | S & F 75mm Hasp and staple, mild steel, wire type, stove aluminiumanodised , including bolt to hinge plate and fixed with screws complete all as specified and directed |
| 50 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, including making good to jambs with cement mortar 1:4 and finished to match with existing surface complete all as specified and as directed. |
| 51 | S&F frame factory made solid PVC door shutter 30mm thick (style) considering of frame made out of MS tubes for top and bottom rail, MS frame shall be covered with head moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width struck in side with solvent cement for stiles and plain colour PVC sheets for top rails and bottom rail on side and on gap insert for top rail and bottom rail panelling of plain colour PVC shutter to be fitted in MS frame included/sealed to the stile, rails with suitable PVC sheet heading and jointed to gether with solvent colour complete all as specified and as directed.. |
| 52 | M&L for brooming down surfaces of any description and applying one coat of white wash onold decorated surfaces of walls including preparation of old surfaces & filling cracks and holes etc complete all as specified and directed. |
| 53 | M&L for brooming down surfaces of any description and applying Twocoat of white wash onold decorated surfaces of Ceilingincluding preparation of old surfaces & filling cracks and holes etc complete all as specified and directed. |
| 54 | M & L for for brooming down surfaces of any description and applying preparation of old wall surfaces, including preparation of old surfaces & filling cracks and holes etc and applying onecoats of cement base paint completeall as specifiedand as directed. |
| 55 | M & L for complete removal of existing treatment and applying two coats of cement based paint on old decorated or undecorated wall surfaceincluding preparation of old surfaces & filling cracks and holes etc, complete all as specified and directed. |
| 56 | M&L for Preparing the surfaces of old wall surfaces and applying one coat of distemper oil emulsioncomplete all as specified and directed |
| 57 | M&L for Complete removal of existing treatment and preparing the surfaces of walls plastered or unplastered and applying two coat of distemper oil emulsionover a coat of alkali resistent primer over putty any thickness.complete all as specified and directed Note : Quoted rate shall deemed to include for cost of wall care putty. |
| 58 | M&L for Preparation of old wooden surfaces and applying a coat of synthetic enamel paint over 10 cm width or girthcomplete all as specified and as directed. |
| 59 | M & L for painting of old steel surfaces of any description not otherwise described over 10 cm width or girth with onecoats of synthetic enamel paint including preparation of surfaces etc complete all as specified and as directed. |
| 60 | M & L for complete removal of old/existing treatment including preparation of wall/Ceiling sufaces of any description and applying two coats of exterior grade weather proof paint water basedover a coat of primer overany thicknessbirla care putty,on wall surfaces complete all as specified and directed.Note : (i) Height of the bldgs is Appx Up to 12 mtr incl Quoted Rates (ii) First the complete removal of existing treatment shall be done and got approved from Engr-in-charge.(iii) Final coat shall be done after getting approval of completion of priming coat from Engr-in-Charge |
| 61 | Taking down chowkats or frame without taking off shutterfrom the frame not exceeding 1.50 Sqm each from the frame and removing from site, including cutting holes for taking out hold fasts and making good disturbed portion in cement mortar 1:3, complete all as specified and as directed . |
| 62 | Taking down chowkates / frame without taking off shutter exceeding 1.50 Sqm not exceeding 4 Sqm each. from the frame and removing from site, including cutting holes for taking out hold fasts and making good disturbed portion in cement mortar 1:3, complete all as specified and as directed |
| 63 | Taking down Shutters of any description exceeding 1 sq. m and not exceeding 2 sq. m each complete all as specified and as directed. |
| 64 | S & F 35 mm thick plain framed panelledfactory made shutters(two panel) with IInd class hardwood rail and style with lock rail and panel of 12 mm BWP commercial ply with commercial vaneer on both faces.The size of rail and style as per IS - 1003 Part - I , kiln seasoned and chemically pressure treated complete all as specified and as directed. |
| 65 | S&F 35mm thickflush shutter, solid core construction with block board core and ply wood face panels, commercial type on both side, complete all as specsified & directed.. The rates for flush shutters shall include for the provision of suitable blocks for taking mortice locks, latches, or other fittings complete all as specified and as directed. |
| 66 | S & F 35mm thick IInd class hardwood glazed and skeleton shutters open rebated and prepared to receive gauge (without sash bars)edges of framingplain, chamfered or round fitted with cut and mitred beads for securing wire gauge sizes of members as specified in SSR Part-I section 8 clase 8.24(a) of shutters all as specified and as directed. |
| 67 | M&L for, Mild steel framed work such as in doors or gates of angle, or tee sections with gusset plates, rails, braces,etc. completely drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging doors fittings (includingof steel sheeting or other covering, running rails and guides) and handing also fastening and fixing complete Gde Fe 410 - W (Grade-E- 250) quality-A complete all as specified and as directed.ll as specified and directed. |
| 68 | S&F butt hinges, medium weight cold rolled mild steel 100 mm size welded to angle iron frames or fixed with screws to wooden frames complete all as specified and as directed. |
| 69 | M & L for applying two coats of synthetic enamel paint over a coat of pink primer including preparation of previously untreated or new wooden surfaces exceeding 10 cm in width or girth complete all as specified and as directed. |
| 70 | M&L for two coats of synthetic enamel paint over one coat of red oxide/zinc chrome primer on new steel surfaces of any description over 10 cm width or girth includingpreparation of surfaces complete all as specified and as directed. |
| 71 | Taking down boards of any description and any size as in shelves complete all as specified and directed. |
| 72 | S & F 19 mm thickplywood BWR type including cutting, jointing, fixing with screws as in kitchen cabinet box type complete all as specified and as directed |
| 73 | S & F Decorative laminate type1, 0.90 to 1mm thick , of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer\"s instructions, complete all as specified and directed. |
| 74 | M&L for 18/19mm thick one side prelaminated particle board, interior grade, with decorative choice laminate and fixed with screws to steel/timber frame work including provision of 6mm thick teakwood edging etc for cupboard, cabinet etc complete all as specified and directed |
| 75 | S & F teak wood beading of size 18/19 mm x 6 mm on the exposed/edges surfaces of the block board complete all as specified and as directed |
| 76 | S & F IInd class hard wood filletssquare cor rectanguler or tringulaer in section wrought fixed to wall with screw area exceeding 6 but not exceeding 13 sq cm complete all as specified and directed |
| 77 | All as per above BOQ srl Item No. 76.00 but area exceeding 3 Sq cm but not exceeding 6 Sq cm complete all as specified and directed |
| 78 | S&F Vitreous China urinals, half stall type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe complete all as specified and as directed. |
| 79 | Supply and fixing vitreous china urinal partition ,white of size 310 x 700mm etc complete all as specified and directed. |
| 80 | S & F waste coupling CP brass (half or full threaded) 32 mm diacomplete all as specified and directed. |
| 81 | S & F fancy type stainless steel handle of size 100 mm longcomplete all as specified and as directed |
| 82 | Disconnecting existing PVC water tank of capacity exceeding 300 ltr but not exceeding 1000 ltr fixed on roof by setting aside (or lowering, if required) for cleaning and removing all scale and dirt from tanks and from mouths of circulating pipes etc and hoisting/refixing/reconnecting in same/new position including writing date of cleaning on each tank with white paint, height/size of letters/figures not less than 10cm in height, and refixing existing serviceable ball valves complete all as specified and directed.” |
| 83 | S&F steel window (box type) factory fabricated, double shutter (glazed and wire gauzed) with side hung shutters including pintle type hinges, steel handles fabricated type for each leaf duly welded, mild steel barrel tower bolts 150mm size (02Nos for each leaf) duly welded, with glazing bars dovetailed or welded including MS fillets, welding with and including 8mm dia Squarguard bars with one shop coat of red oxide zinc chrome primer overall complete all as specified and as directed Notes:(i) Windows shall be fabricated as per CE Palam drawing No. TD-219 Sh 1/3 to 3/3 dated 02 Jan 2007 (updated up to date) and these drawings shall be referred at the O/o the GE (AF) Ambala(ii) Glazing and wire gauge will be measured and paid separately under respective items herein(iii) Any other sundries, etc. as required at site shall be deemed to be included in the quoted rate |
| 84 | M&L for Preparation of newly steel surfaces of any description over 10 cm width or girth & applying two coats synthetic enamel paint complete all as specified and directed. |
| 85 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and remove the debris outside of MD land, complete all as specified and as directed. |
| 86 | S&F 3 mm thick sheet glass ordinary quality not exceeding 0.50 sqm each pane and fixed with oil putty or with wooden beading in square etc complete all as specified and directed. |
| 87 | All as per BOQ srl Item No.86.00 here-in-above but figured glass complete all as specified and directed. |
| 88 | S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples fixedwith Flat Ironbeading/nut& bolt and wooden beading complete all as specified and directed. |
| 89 | S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples fixed with Flat Ironbeading/nut& bolt and wooden beadingin repair complete all as specified and directed. |
| 90 | S & F Aluminium anodized barrel tower bolts of extruded section, 150 mm long all as specified and as directed. |
| 91 | S & F Aluminium anodized cast type handles 150mm long all as specified and as directed. |
| 92 | S&F Stainless Steel butt hinges medium weight of size 100 mm complete all as specified and directed. |
| 93 | S & Fin repair door stopper of rubber and aluminium alloy body, 150 mm size fixed all as specified and as directed. |
| 94 | S&F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised with width of flaps (When open) 30 mm complete all as specified and as directed. |
| 95 | S/F in repair tubular curtain rail, aluminium anodized 20 mm dia all as specified & as directed including taking down unserviceable rod/rail complete all as specified and directed. |
| 96 | S/F Aluminium decorative type brackets suitable to hold the curtain rod with sofio phenol (Lotto) and wooden round blocks suitable to curtain rod of 20mm dia, decorative type fixed with suitable steel screws and PVC cleats, including taking down unservicable brackets complete all as specified and directed. |
| 97 | S & F in repairs of 300 mm mild steel ordinary rat tail, rod pattern springs including roller and roller plate completeincl welding all as specified and directed. |
| 98 | Taking down unserviceable GI tubing, supply and fixing new 15 mm bore Galvanized Iron tubing, medium grade, with all fittings, such as Tee, elbows, sockets, unions, short pieces and application of bituminous paint in concealed portion, fixed to wall/ ceiling or laid on floors, complete all as specified and as directed.Notes: i)Serviceable Taps, valves in any shall be removed before taking down pipe and same shall be re-fixed while providing new pipe,ii) Cutting chases for concealed piping shall be measured and paid separately under respective item. |
| 99 | Taking down unserviceable GI tubing, supply and fixing new 20 mm bore Galvanized Iron tubing, medium grade, with all fittings, such as Tee, elbows, sockets, unions, short pieces and application of bituminous paint in concealed portion, fixed to wall/ ceiling or laid on floors, complete all as specified and as directed.Notes: i)Serviceable Taps, valves in any shall be removed before taking down pipe and same shall be re-fixed while providing new pipe,ii) Cutting chases for concealed piping shall be measured and paid separately under respective item. |
| 100 | Refixing 20mm bore water tubing surface/concealed in same/new location after cleaning and application of bituminous paint on concealed portion of tubingincluding cutting & threading pipe and provision of additional fittings such as socket, tee, elbow, union (if required) complete all as specified and directed.Note : i) Taps, valves if any shall be removed before taking down pipe.ii) Cutting chases and making good shall be measured and paid separately |
| 101 | Cutting chases pinning in making good for brick walls to facing where required and pointing in cement mortar 1:3 to ends or edges of concealed water tubing and similar work including making good cutting not exc 10CM girth. Complete all as specified and directed. |
| 102 | S & F in repair15 mm CP cast copper alloy bib taps fancy type screwed down, screwed for iron pipe or for brass ferrule including taking down old bib taps complete all as specified and as directed. |
| 103 | S & F 15 mm pillar taps, cast copper alloy fancy type , chromium plated screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’with long screwed shanksand fly nuts, screwed for iron pipe including taking down old pillar taps complete all as specified and as directed. |
| 104 | S & F in repairs CP fancy type angle cock, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 105 | S&F in repair chromium plated overhead shower rose 125mm dia with swivel joints with and including overhead shower arm 230mm with wall flange , complete all as specified and directed by GE. |
| 106 | S & Fin repairs, 15mm Stop valves (concealed), fancy type with CP wall flanges, chromium plated, cast copper alloy with long shank and exposed part kit with fittings sleeve, operating lever concealed part screwed both ends for iron pipe or for unions, including making good the disturbed portion matching with adjacent surfaces, complete all as specified and as directed |
| 107 | S&F in repair, Chromium plated Wall mixer with bend pipe for overhead shower with built-in non return valve with CP wall flanges,complete all as specified and directed by GE |
| 108 | S&F in repair Centre hole wash basin mixer for wash hand basinmake Jaquar/ equivalentcomplete all as specified and directed |
| 109 | S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 mtr tube & hook (braded Tube) and ABS valve including making connection and fixed in position complete all as specified and directed. |
| 110 | S&F in repair Single towel rail brass chromium plated 600mm long fixed with chromium plated screw and PVC cleat etc complete all as specified and directed. |
| 111 | S & F in repair PVC connecting pipe 600mm long 15 mm dia both end having brass coupling nut and PVC washer all as specified and as directed. |
| 112 | S&F Vitreous china white wash down water closet pan (pedestal pattern) with PP soft closing seat cover, hinges, fixing accessories set(excluding flushing cistern and flush pipe), including UPVC (SWR) ‘P’ or ‘S’ trap and connection to drain (or outgoing pipe) and to flush pipe, antisyphonic pipe fixed in repair including dismantling existing water closet etc complete all as specified and directed by GE” |
| 113 | S&F Vitreous china White Squatting Orissa Pattern pan of size 580x440mm, including UPVC ‘P’ or ‘S’ trap, front or back inlet andintegral foot rests and makingconnection to trap and to flushing pipe, anti syphonic pipe, fixed in repair including dismantling existing squatting pan and making good to disturbed floor,complete all as specified and directed. |
| 114 | S& FVitreous China wash basin, white, flat back, size 550x400mm excluding waste, chain and plug and porcelain stopper but including brackets, including Waste coupling of PTMT(half or full threaded) (Minimum weight 32mm-45gms/40mm-60 gms)with 32mmbore PVC waste pipe minimum 800mm longwith inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed in repairs complete all as specified and as directed. |
| 115 | S&F in repairs, PVC valve less, syphonic action type, white colour flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle including jointing with new PVC long / short flush bend and making good to the disturbed surfaces complete all as specified and as directed. |
| 116 | S & F in repairs Plain looking mirror of size 600x450 mm with bevelled edge selected quality glass mounted on 6mm thick commercial plywood and fixed with chromium plated brass screw and cup washers complete all as specified and as directed. |
| 117 | S & F stainless steel sink with draining board, made out of 1.00 mm thick sheet for kitchen with plugs, waste pipe and washer’sincluding cast iron cantilever brackets, connecting union etc over all size 915 mm x 460 mm with bowl size 410 x 330 x 160 mm including taking down old steel sink all as specified and as directed. |
| 118 | S&F in repairs stainless steel plate rack of 0.63mm thick sheet, size 31\"\"x36\"\"x10\"\" complete all as specified and as directed. |
| 119 | S&F in repair PVC waste pipe 32/40mm bore not less than 800mm long complete all as specified and direceted |
| 120 | Dismantling of water tanks of 1000 litres capacity from roof top and supply and fixing Rotational moulded polyethylene water storage tanks (triple layered) of 1000 Litres capacity with ISI mark embossed on it, (cylindrical, vertical with closed top) hoisted and fixed in position complete all as specified and as directed. |
| 121 | Dismantling of water tanks of 500 litres capacity from roof top and supply and fixing Rotational moulded polyethylene water storage tanks (triple layered) of 500 Litres capacity with ISI mark embossed on it, (cylindrical, vertical with closed top) hoisted and fixed in position complete all as specified and as directed. |
| 122 | S&F in repair Ball valves high pressure PTMT with epoxy coated aluminium rod and high density plastic ball scrured for iron pipe of dia 20 mm bore complete all as specified and directed . |
| 123 | S&F in repair for 15 mm dia Gun-metal, globe or gate valves/, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and as directed. |
| 124 | M & Lin repair Gun metal Gate valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed including cutting the old pipes as in repair complete all as specified and directed |
| 125 | S&F in repairCornerglass self assembly consisting of 5.5mm thick sheet glass self 25cm wide with chromium plated bracket guard and fixed with CP screws and wood cleats with wall complete all as specified and directed. |
| 126 | S&F in repair glass self assembly consisting of 5.5mm thick sheet glass self 12cm wide with chromium plated bracket guard and rail 60cm long and fixed with CP screws and wood cleats with wall complete all as specified and directed. |
| 127 | Taking down eaves gutters, soil / waste / vent pipes / rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., Supply and fix, UPVC (SWR) pipes 110 mm dia, type B (conforming to IS 13592) single socketedin any length with solvent cement joints laid under floor or on walls fixed as soil / waste / vent pipes with Stack clamps made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall complete all as specified and as directed.Note :- Provision of necessary scaffolding for replacing defective pipes shall deemed to be included in quoted rates, and nothing extra will be admissible in this regards. |
| 128 | Taking down eaves gutters, soil / waste / vent pipes / rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., Supply and fix, UPVC (SWR) pipes 75 mm dia, type B (conforming to IS 13592) single socketedin any length with solvent cement joints laid under floor or on walls fixed as soil / waste / vent pipes with Stack clamps made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall complete all as specified and as directed.Note :- Provision of necessary scaffolding for replacing defective pipes shall deemed to be included in quoted rates, and nothing extra will be admissible in this regards. |
| 129 | S & F PVC (SWR) bends any radius 75 mm dia of bore with access door, including taking down old bends all as specified and as directed. |
| 130 | S & F PVC (SWR) branch piece single (single T)equal of bore 75 mm dia with access doorin repairs complete all as specified and as directed. |
| 131 | S & F PVC (SWR) branch piece single (single T) equal or unequal of bore 110 mm dia, with access door in repairs complete all as specified and as directed. |
| 132 | S&F UPVC (SWR) bends any radius, 110mm bore with / without access door, complete all asspecified and directed. |
| 133 | S & F PVC (SWR) multi-floor trap, plain with chromium plated grating including jointing with solvent cement, 75mm dia, including dismantling the damaged trap, complete all as specified and directed. |
| 134 | S&F in repair PVC floor trap/Nanhi Trap with plain/single hole CP grating including jointing to waste pipe in cement joint, of outlet 75 mm.dia .complete all as specified and as directed. |
| 135 | S& FGI spout40 mm dia medium grade to be embeded in sunken floor complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail