| 1 | Demolition of brickwork or stone work/boulder masonary built in cement mortar or cement lime mortar complete all as specified and directed. |
| 2 | M&L for Brick work with old size fly ash bricks straight or curved on plan exc 6m mean radiusand setting in cement mortar (1:6) complete all as specified and directed. |
| 3 | Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for pavement of NLB/taxi track/runway/dispersal area as complete all as specified and directed. |
| 4 | Removing excavated / Demolished material exceeding 1.5 km but not exceeding 5.0 km and depositing where directed complete all as specified and directed. |
| 5 | M&L forin repair for hard core of broken stone or boulder of gauge not exceeding 63mm, deposited, spread and leveled in layers not exceeding 15cm thick, watered and rammed to a true surface except material complete all as specified and as directed. |
| 6 | M&L for 100mm thick cement concrete design mix M-25using 20 mm crushed stone aggregate as in pavings/hard-standing/NLB/Taxiway finished the concrete surface even and fair without using extra cement(laid in alternate panels with &including necessary formwork complete all as specified and directed.(Note: Concrete to be procured from RMC-M25 design mix only). |
| 7 | M&L repairfor forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound,Grade \"B\" upto 150 mm thick cement concretecomplete all as specified and directed. |
| 8 | M & L for forming construction (dummy) joints 65mm deep x10mm wide filled with sealing compund grade \"B\" completeall as specified and directed. |
| 9 | M & L for sand(Moorum Source Banda) filling in floors, 25 mm thick, spread levelled and rammed including watering and consolidating complete all as specified. |
| 10 | M&L for 100mm thick cement concrete (1:4:8) type D-2using 40mm graded stone aggregate as in sub base of floor/Pathwaycomplete all as specified and directed. |
| 11 | M&L for 80mm thich machine pressed precast concrete interlocking paver block plain/ coloured reflective type rubber moulded withpigment any shape and size confirming to IS 15658-2006 of M-40 grade complete all as specified and as directed. |
| 12 | M&L for factory made pre cast kerb stone of M-25 grade at or near ground level cement concrete in position to the required line,level and curvature,jointed with cement mortar (1:3) includiing making joints with or without grooves complete all as specified and directed. |
| 13 | M & L for preparation of new plastered/concrete surface/brick stone/kerb stone surfaces of any description not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of priming paints plaster coat including necessary rubbing with sand paper or grinded by hand grinder to achieve smooth and even surface complete. |
| 14 | M&L for design mix quality cement concrete work using crushed stone aggregate in path/hard-standing of minimum flexural strength 40kg/per square centimetre in field using not less 400kg of cement/Cum, thickness of concrete 25cm or less with & including all necessary formwork complete all as specified and directed.(Note: -(i) Cement shall be provided as per approved design mix but not less than 400kg/Cum.(ii) In the event of increase in cement content as per design mix formula, nothing extra shall be admissible an this account and quoted rates are deemed to be includes for the same.(Note: Concrete to be procured from RMC-M35 design mix only). |
| 15 | M& L for finishing of concrete roads,pavements by brooming omplete all as specified and directed. |
| 16 | M&L for Pre-cast saucer drain of size 300mm x 300mm x 100mm for Pedestrian areas,parking area etc. Complete all as specified and directed. |
| 17 | Dismantling PVC/Cement/CI pipes 50 to 110 mm diaincluding allfittings like bend,branch pieces, connectors, heel rest bend etc and removing from site complete all as specified and directed. |
| 18 | S&F110 mm bore UPVC (SWR) pipe type B, single socketed in any length with rubber ringjoints, laid in trenches orin floors, complete all as specified and directed. |
| 19 | M& L for rendering of external surface 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces includinguprooting/cutting of vegetation growth (maximumheight upto three stories specified and directed (Note:- Below 10 Sqm Qty shall be executed throuth conventional method). |
| 20 | M&L for preparationof newplastered/ concrete surfaces of walls to achieve smooth and even surfaceandapplying two coats of cementbase paint over and includingone coat of primer complete all as specified and directed. |
| 21 | M& L for friction/slip/skid resistance field test of flexible portion of runway rigid pavement portion of taxi track & dispersal through approved Govt. labs or other Govt agencies or approved pvt labs complete all as specified and directed. |
| 22 | M&L for condition survey of rigid pavement i.e concrete portion of PTT both ends of runway with & including details taken of hair lines cracks, surface lining , map lining , epoxy area, difference in slab, minor cracks etc complete all as specified and directed. |
| 23 | Taking down carefully switch board complete along with old MS rectangular sunk type box heavy/medium duty of size 8 to 12 module from the existing position along with switches sockets regulators etc by unscrewing from board by disconnecting electric connections without damaging existing circuit and conduit complete and reconnecting all connection after comletion of job with making good the disturbed surface to match the existing one complete all as specified and directed. |
| 24 | Taking down carefully switch board complete along with old MS rectangular sunk type box heavy/medium duty of size 4 to 6 module from the existing position along with switches sockets regulators etc by unscrewing from board by disconnecting electric connections without damaging existing circuit and conduit complete and reconnecting all connection after comletion of job with making good the disturbed surface to match the existing one complete all as specified and directed. |
| 25 | Taking down carefully switch board complete along with old MS rectangular sunk type box heavy/medium duty of size 1 to 4 module from the existing position along with switches sockets regulators etc by unscrewing from board by disconnecting electric connections without damaging existing circuit and conduit complete and reconnecting all connection after comletion of job with making good the disturbed surface to match the existing one complete all as specified and directed. |
| 26 | M&L formodular metal flush boxes and white cover plate with frame of size 6/8 modulefor mounting modular type switches /socket/fan/ regulator etc complete all as specified and directed. Make - Goldmedal/crabtree(havells)/L&T or equivalent |
| 27 | M&L formodular metal flush boxes and white cover plate with frame of size 4 modulefor mounting modular type switches /socket/fan/ regulator complete all as specified and directed. Make - Goldmedal/crabtree(havells)/L&T/ Seimens/ Legrand/C&S. |
| 28 | M&L formodular metal flush boxes and white cover plate with frame of size 3 modulefor mounting modular type switches /socket/fan/ regulator complete all as specified and directed. Make - Goldmedal/crabtree(havells)/L&T/ Seimens/ Legrand/C&S. |
| 29 | M&L formodular metal flush boxes and white cover plate with frame of size 1/2 modulefor mounting modular type switches /socket/fan/ regulator complete all as specified and directed.Make - Goldmedal/crabtree(havells)/L&T/ Seimens/ Legrand/C&S. |
| 30 | Supply and fix in repair modular switch 1 way 6A 1 module type complete all as specified and directed. Make - Goldmedal/crabtree(havells)/L&T / Seimens/ Legrand/C&S. |
| 31 | Supply and fix in repair modular switch 1 way 16A 1 module type complete all as specified and directed. Make - Goldmedal/crabtree(havells)/L&T / Seimens/ Legrand/C&S. |
| 32 | Supply and fix in repair modular Socket6A3 pin combined 2 module complete all as specified and directed. Make - Goldmedal/crabtree(havells)/L&T / Seimens/ Legrand/C&S. |
| 33 | Supply and fix in repair modular Socket16A - 3/5 pin combined 2 module complete all as specified and directed. Make - Goldmedal/crabtree(havells)/L&T / Seimens/ Legrand/C&S. |
| 34 | Supply and fix in reapir Modular step type regulator 1 module type all as directed.Make - Goldmedal/crabtree(havells)/L&T / Seimens/ Legrand/C&S. |
| 35 | Supply & Fix LED tube RETRO LED 16to 22 watt of size 4 ft long complete all as specified & approved by EIC.Make :- Philips / Havells/ Bajaj/L&T. |
| 36 | S&F in repair decorative box type fitting for LED tube 16 to 22watt luminaire for 230 volt AC,for LED tube 16 watt to 22 watt complete all as specified and directed . Make :-PhilipsHavells/ Bajaj/L&T. |
| 37 | S&F 1100 volts grade heavy duty cable PVC insulated copper conductor, served with inner sheathing of PVC tape and overall PVC sheathed flexible two core cable flat or circular of size 1.5 Sqmm solid copper conductorcomplete all as specifiied and directed.Make :- Havells/ Plaza/Finolex/Polycab. |
| 38 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fitting and fixture such as switches, sockets ceiling rose,pendent holders,regulators,light fittings any type removing materials to store in safe custody or for credite etc, and making good the disturbed surface & complete all as specifiied and directed. |
| 39 | M&L for point wiring with two single core PVC insulated & PVC unsheathed FRLS-H multistranded copper conductor cable of size 1.5 sqmm 1100 volt gradeconcealled conduit and including making good the disturbed surfaceof wall with colour washing /distempering the surface to match the existing surfaces into and including non metallic rigid PVC conduit medium grade 2 mm thick of 20/25 mm dia with all accessories mounting all the surface of wall/ceiling/roof/etc with suitable size of 1 to 8 module metal flush boxes and including modular front coverplate & back plate for mounting modular type switches /socket/fan/ regulator etcincluding provision of one single corePVC insulated and unsheathed multi stranded copper cable of size 1.5 sqmm 1100 volt grade as earth continuty conductor connected to common earth dollyswitch board complete all as specified and directed.Make-Polycab/Finolex/RR kabels/Plaza. Note:-Surface Conduit shall be laid in celing portion only.Make: Plaza/havells/polycab/FinolexFor One light/fan point controlled by one switch. |
| 40 | Ditto all as per item No 39 here-in-before but for one socket outlet point 5 Amp on an independent board |
| 41 | Ditto all as per item No 39 here-in-before but for same as item no 17 (b) but on the same board |
| 42 | Ditto all as per item No 39 here-in-before but for one bell/ buzzer pointcontrolled by one bell push |
| 43 | Dittto all as item no 39 here-in- before but using 2.5 sqmm , PVC insulated, stranded copper conductor single core cable for one 3 pin 15 Amp socket out let point on an independent board. |
| 44 | S&F Modular switch 1 way 6A 1 module type complete all as specified and directed. |
| 45 | S&F Modular switch 1 way 16A 1 module type complete all as specified and directed. |
| 46 | S&F Modular Socket6A3 pin combined 2 module complete all as specified and directed. |
| 47 | S&F Modular Socket16A - 3/5 pin combined 2 module complete all as specified and directed. |
| 48 | S&F in replacementmodular bell push single pole one way 6/10 Amp, 240 volt,1 module, fuesh typecomplete all as specified and directed. |
| 49 | S&Fceiling Rose, surface, bakelite of size 65mm x50 mm three terminals, AC, 230 Volts complete all as specified and directed. Make :- Anchor / Havells/ Legrand/ L&T. |
| 50 | S&F in repair FTL fittings with decorative LED batten made up of aluminium casting18/20 Wof size complete standard fittings and fixtures including fixing on walls/roofs/ through MS downrod suspended typewith fitting arrangement including neccessary electric connection from ceiling rose to luminaries with suitable size PVC cord complete all as specified and directed. Make:- Philips/ Havells/ Bajaj/ L&T. |
| 51 | M&L forflame proof pointwiringwith two single core FRLS-H PVC insulated& PVC unsheathed multi stranded copper conductor cable of size 1.5Sqmm1100 voltsgrade drawn into andincludingstove enamelled steel conduit of size20 to 25 mmwith all accessories and one single core PVC insulated & PVC sheathed multistranded FRLS-H copper cable of size 1.5 Sqmm 1100 Voltsgradeas earthcontinuityconductorconnectedto commonearth dolly, switch board complete incuding cutting chasses on wall/ floour/ ceiling etc. & making good the disturbed surface in CM (i:4) complete all as specified and directedfor one light / fan point controlled by one 5 Amps flameproofswitch one way complete. Make-Polycab/Finolex/RR kabels /Havells/Plaza |
| 52 | S&F LED Light Fitting 2x20 Watt flame proof ,CMRI certified recommended for gas/vapour group of IIA &III B ,zone 1 and 2 and IP 65 Protection with die cast alluminium housing with heat resistant toughned glass with LED tube light, fixtures, driver holders ,connectors etc complete with all accesories prewired and including connecting with three core flexible copper conductor cable of suitable sizecomplete all as specified and directed. |
| 53 | S&F in repair for submain wiring with two run of single core PVC FRLS-H insulated unsheathed multi stranded copper conductor cable of size 4 Sqmm 1100 volts grade and onerun of PVCinsulated unsheathed multi stranded copper conductorcable of size 4Sqmm 1100 volts grade as earthcontinuity conductor drawn through in and includingrigid non metallic PVC concealed / surface conduit of suitable size onroof/wall/ceiling includingmaking good the disturbed surfaces ofwall etc complete all as specified and directed. (Note : Two run of single core cable and one run of earth wire will be measured as one lengthandconduit and its accessoriesis deemed to be included in the quoted unit rate).Make- Polycab/Havells/RR kables/plaza. Make of PVC conduit :- AKG/ Plaza/ Jindal / Finolex |
| 54 | S&F in repairfor Submain wiring with 2 single core PVCinsulated FRLS-H multistrand copper conductor cable of size 10 Sq mmdrawn into and including non metallic heavy duty rigid PVCconduit not less than 25mm size ISI marked ivory colour (Pressfit or similar brand ) with all conduit fittings / accessories and 1 run single core 10 Sq mm FRLS-H multi-stranded copper conductorcable as continuous earth wire complete all as specified and directed.(Note for submain wiring: 10 run of single core cable and two run of earth wire will be measured as one length).Make:- Polycab/Havells/RR kables/plaza. Make of PVC conduit :- AKG/ Plaza/ Jindal / Finolex |
| 55 | Takingdown old unserviceablemainswitches/DB’s up to 100 Amps capacity fixed in wall and making good of all disturbed surfaces as perexisting complete all as specified and directed. |
| 56 | S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 4 way, AC,240 volt with 200 Amp bus bar rating complete all as specified and directed. Make :- Legrand/ Seimens /L&T /Havells. |
| 57 | S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 8 way, AC,240 volt with 200 amp bus bar ratingcomplete all as directed. Make :- Legrand/ Seimens /L&T / Havells. |
| 58 | S&Fsheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 12 way, AC,240 volt with 200 Amp bus bar rating complete all as specified and directed. Make :- Legrand/ Seimens /L&T / Havells. |
| 59 | S&Fsheet metal enclosure double door (MCB DB) three phase and neutral with 200 Amps rated bus bar TPN,4 wayverticall type, with provision of MCB incommer, AC, 415 Voltcomplete all as specified & directed. Make :- Legrand/ Seimens /L&T / Havells. |
| 60 | S&Fsheet metal enclosure double door (MCCB DB) three phase and neutral with 200 Amps rated bus bar VTPN,4 way vertical type, with provision of MCCB incommer, AC, 415 Voltcomplete all as specified & directed. Make :- Legrand/ Seimens /L&T / Havells. |
| 61 | S&F MCBsingle pole, 6 to 32Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified and directed. Make :- Legrand/ Seimens /L&T / Havells. |
| 62 | S&FMCBsingle pole, 32 to 40 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified and directed. Make :- Legrand/ Seimens /L&T / Havells. |
| 63 | S&F MCB DP 40 to 63 Amps 240 Volts, 50 Hz, 10 KA breaking capacity complete all as specified and directed. Make :- Legrand/ Seimens /L&T / Havells. |
| 64 | S&F MCB Four Pole 40 to 100 Amps 415 Volts, 50 Hz, 10 KA breaking capacity complete all as specified and directed. Make :- Legrand/ Seimens /L&T / Havells. |
| 65 | S&F MCCB 4 pole 100 / 125 Amp 415 volts 50 HZ25 KA breakingcapacity complete all as specified and directed. Make :- Legrand/ Seimens /L&T / Havells. |
| 66 | S&F in modular type AC boxwith socket plug top and MCBs withtwo pin and one pin forearth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed. Make: Anchor/Havells/C & S / Legrand. |
| 67 | S&F in PVC casing and caping of 20/ 25 mm wide complete all as specified and directed. |
| 68 | S & F in repairs integrated LED type Post top lantern with high power 10/15 W LED as light source, energy saving, environmental friendly, long life asethetically designed with symmetrical light distribution, spun aluminium landscape lumainaire incl LED driver including all neceesary electrical connection complete all as specified and directed. Make :- Phillips/ Bajaj/Havells/L&T. |
| 69 | S&F in repair super bright LED (2X2), 36 W, 6500 K recess/surface mounting minimum 100Lumens/watt IP20 ,IK02 PF>.9 and 4kv inbuilt surg protectionwith high efficient LED source complete all as per specified and directed. Make :- Legrand/ Seimens /L&T / Havells. |
| 70 | S & F in repairs integrated LED type Bollard , 10/12 W LED as light source, IP 65, energy saving, environmental friendly, long life asethetically designed with symmetrical light distribution incl LED driver with base plate and pcc and earth work for grouting the lightcomplete and incl neceesary electrical connection complete all as specified and directed . Make- Phillips, Bajaj , Havellsor equivalent. |