|
| 1 | Demolition of cement Concrete (unreinforded) in ground floors and pavings n exc 15 cm thickness (below or above ground level). removing debries of the the site complete all as specified and directed. |
| 2 | M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternatebays (not exceeding 2 Sqm each)and finished even and smooth without using extra cement and providing jointsthroughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed. |
| 3 | Demolition of brick work built in cement mortar of any description including all quoins, arches, pillars,etc complete all as specified and as directed. |
| 4 | M&L brick work with sub- class ‘B’ bricks straight or curved on plan exc 6 m mean radius complete all as specified and all as directed. |
| 5 | M&L Brickwork with sub-class ‘B’ bricks in brick-on-edge walls (less than ½ brick thick), built in cement mortar 1:4, complete all as specified and as directed. |
| 6 | Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete including removing debries of the permises, complete all as specified and as directed. |
| 7 | M&L 15mm thick rendering with cement mortar (1:4)on fair faces of brick work mixed with water proofing compound as per manufacturer\"s instructions and finishing the surface even and smooth without using extra cement complete all as specified and as directed.Note:- WPC shall be measured and paid seperately under appropiate item. |
| 8 | Supply only Integral water proofing compoundconforming to IS: 2645 specification complete all as specified and as directed. |
| 9 | M&L preperation of new plastered surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 10 | Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing),removing debries/ rubbish of the permises complete all as specified and directed. |
| 11 | M&L Non - skidcoloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in cementitious tile adhesive and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6,for laying floor finishes, complete all as specified and directed. |
| 12 | M&L Glazed ceramic coloured tiles in vertical surfaces 450x 300x 7 mm thick set and jointed in cementitious tile adhesive & pointed in white or colour cement to match including backing coat 10 mm thick in Cement Mortar 1:4, complete all as specified and directed. |
| 13 | M&L for water proofing treatment to RCC sunken slab, comprising with the following course of treatment/specification from bottom to top, including demoliation of concrete of existing concrete and removing debries complete all as specified and directed:-(i) Cleaning of old concrete surfaces of roof, picking sweeping cleaning the surface to remove all loose dust and thoroughly washing down with clean water and dried complete and providing PCC 25mm thick average thickness Type B0 (using 20mm graded aggregate) as levelling course laid in slope towards spout mixed with and including water proofing compound as per manufacture instruction (ii)Rendering 10mm thick in CM (1:4) mixed with and including water proofing compound as per manufacture instructionon sunken roof slab surface true to level over PCC when concrete is green(iii) Applying first layer of slurry @ 0.488 Kg/Sqm mixed with acrylic based polymer modified cementious compound @ 0.253 Kg/Sqm. The layer shall be allowed to air cure for 4 hours(iv) Applying second layer of slurry @ 0.242 Kg/Sqm mixed with acrylic based polymer modified cementious compound @ 0.126 Kg/Sqm. The layer shall be allowed to air cure for 4 hours(v) One coat of Industrial bitumen of grade 85/25 @ 1.5 Kg/Sqm on plastered surfaces as per manufacturers instructions. (vi) Laying layer of 200 micron polythene film(vii) Two Nos of 25mm dia, light grade, 45cm long, Spout shall be provided in external wall to drain out acummalted water(viii) PCC (1:5:10) type E-2 (using 40 mm gradedstone aggregate) as in filling ofsunken portion of slabNote : (a) Sunken slab shall be tested for water tightness by filling water for 72 hours before filling PCC lean concrete |
| 14 | Dismantling posts or struts (wood, steel or R.C.C.) any section, embedded in natural ground including taking out embedded portion and making good disturbed ground complete all as directed. |
| 15 | Dismantling fencing wire mesh,any type complete all as directed. |
| 16 | Excavating in post holes (or similar holes) each n exc 0.5 cu.m, getting out in soft/loose soil and removing debries not exceeding 50 metre and depositing where directed complete all as directed. |
| 17 | S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 including preperation of surfaces and applying a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 18 | Supply only chain link MS galvanized fencing of any type or size as ordered, complete all as specified and as directed. |
| 19 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed |
| 20 | S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (eachline wire to be measured) complete all as specified and as directed |
| 21 | S&F mild steel screw bolts (machine made)with hexagonal head at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal nut, length of bolt exceeding 10cmand not exc 15cm long, dia of neck 11 to 15mm complete all as specified and as directed. |
| 22 | M&L TMT bar 8-10 mm dia, cut to length, bent to shape required, including cranking, bending as in straining of fencing and binding or securing with clipscomplete all as specified and as directed. |
| 23 | Demoliation Reinforced cement Concrete of any description and in any position not otherwise specifically provided for removing debries of the the site complete all as specified and as directed. |
| 24 | M&L for Precast reinforcedcement concrete type 1:2:4 (using 20mm graded aggregate) cover slab as in drain cover, manhole cover, etc, set in cement mortar 1:6 complete all as specified and directed. |
| 25 | M & L for TMT reinforcement 10 mm dia and over cut to length bent to shape including cranking, banding spirally for hooping columns, hookingend and binding with and includingmild steel wire not less than 0.90 mm dia (annealed) complete all as specified anddirected . |
| 26 | S&F mild steel TMT bar 5 mm dia and over upto and including 10mm dia in strrups as inincluding cutting, bending and binding with and including mild steel not less than 0.9 mm dia (annealed)complete all as specified anddirected . |
| 27 | S&F in repair, 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings complete all as specified and as directed. |
| 28 | S&F 75mmbore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 29 | M&L preparation new iron and steel surfaces of any description, exc 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 30 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings complete all as specified and as directed. |
| 31 | Cutting hole in brick wall/concrete surface including taking down defective/unserviceable part causing seepage/leakage i.e P & S trap, connector, bend or \"Y\" junction and refixing of serviceable parts in the same position and removing of unserviceable parts & sealing by three number of joints with Aqua Epoxy Compoundmaking good disturbed surface with PCC 1:2:4 type B0 and cement plaster 15mm thick in CM1:4 mixed with and including using water proofing compound as per manufacturers instruction and applying two coats of cement base paint to match the existing surface complete all as directed.Note: The work shall be carried out upto 4.00 M height and rates for scaffolding are deemed to be included in the quoted rate |
| 32 | Excavation in Trenches not exc. 1.50 Metre Wide and not exc. 1.50 Metre in Depth for Foundation etc. or for Shafts, Wells, Cess Pits, Manholes, Pier Holes, Sewage/pipe line.etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 33 | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 25 Cm in Soft/Loose Soil and providing heaps along the Sewage Lines, complete all as specified and as directed. |
| 34 | Removing excavated material and depositing upto a total distance of 50m where directed at a alevel not exc 1.5m above the starting point complete all as specified and directed . |
| 35 | Demolition and breaking up drain pipes 100mm bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar including demoliation of PCC packing under, and haunching to Sides of the Pipes (except Bed), complete all as directed . |
| 36 | Demolition and breaking up drain pipes 150mm bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar including demoliation of PCC packing under, and haunching to Sides of the Pipes (except Bed), complete all as directed . |
| 37 | Demolition and breaking up drain pipes 200mm bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar including demoliation of PCC packing under, and haunching to Sides of the Pipes (except Bed), complete all as directed . |
| 38 | Supplying, laying and testing of 100 mm internal dia of double wall corrugaed (DWC) high density polythylene pipe (HDPE) and stiffness classes 8 (SN-8) with ISI marked (With CML No ) with and including all fittings & jointing materials for connection of sewage line complete all as specified and directed. |
| 39 | Supplying, laying and testing of 150 mm internal dia of double wall corrugaed (DWC) high density polythylene pipe (HDPE) and stiffness classes 8 (SN-8) with ISI marked (With CML No ) with and including all fittings & jointing materials for connection of sewage line complete all as specified and directed. |
| 40 | Supplying, laying and testing of 200 mm internal dia of double wall corrugaed (DWC) high density polythylene pipe (HDPE) and stiffness classes 8 (SN-8) with ISI marked (With CML No ) with and including all fittings & jointing materials for connection of sewage line complete all as specified and directed. |
| 41 | M&L Concrete bed to drain pipes of 100mm bore pipe including packing under, and haunching against the sides of pipes after they are laid and tested; in 1:3:6 type C2 (40mm graded aggregate) complete all as specified and directed. |
| 42 | M&L Concrete bed to drain pipes of 150mm bore pipe including packing under, and haunching against the sides of pipes after they are laid and tested; in 1:3:6 type C2 (40mm graded aggregate) complete all as specified and directed. |
| 43 | M&L Concrete bed to drain pipes of 200mm bore pipe including packing under, and haunching against the sides of pipes after they are laid and tested; in 1:3:6 type C2 (40mm graded aggregate) complete all as specified and directed. |
| 44 | M&L 100mm dia of outlet Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) including dismantling existing unserviceable trap complete all as specified and directed. |
| 45 | M&L 100mm dia of outlet Cast iron Nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) including dismantling existing unserviceable trap complete all as specified and directed. |
| 46 | S&F in repair 15mm bore Bib taps, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 47 | S&F in repair 15mm bore Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) complete all as specified and directed. |
| 48 | S&F in repair 15mm bore Stop valves, fancy type, chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 49 | S&F in repairs 15mm bore stop valves fancy type cast copper alloy, chromium plated with long shank and cup (concealed type), screwed both ends including necessary fittings such as sockets for pipe or for union all complete as specified and as directed. |
| 50 | S&F in repair, 125mm Brass chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed. |
| 51 | S&F in repair Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges completeall as specified and directed. |
| 52 | S&F in repair 600x450mm bevelled edge mirror of selcted quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified complete all as specified and as directed |
| 53 | S&F in repair Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. complete all as specified and directed. |
| 54 | S&F in repair 32mm bore Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm-45gms) complete all as specified and directed. |
| 55 | S&F in repair, 32mm bore Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc.with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed,complete all as specified and directed. |
| 56 | S&F in repair,32mm bore Low density polyethylene pipes (LDPE) of pressure rating 6kg/cm2 laid in trenches complete all as specified and directed. |
| 57 | S&F in repair, vitreous China pedestal wash basin, white, flat back, size 550x400mmincluding brackets including cutting forand pinning in ends of brackets or erecting stand complete all as specified and as directed. |
| 58 | S&F in repair Vitreous China wash down water closet pan, pedestal pattern white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. |
| 59 | S&F in repair, Vitreous China squatting pan \"Orissa\" pattern size 630x450mm white with integral foot rest , including S or P traps (Excluding flushing cistern & flush pipe), laid over 150mm thick cement concrete (1:5:10) type E2 using(40mm graded aggregate) of complete all as specified and directed. |
| 60 | S&F in repair 10 ltrs capacity low level valve less PVC syphonic action type flushing cistern white with in let ball valve float and handle, PVC flush pipe, complete all as specified and as directed. |
| 61 | S&F PVC connection 15mm size with PTMT nuts, 600mm long complete all as specified and as directed. |
| 62 | Taking up or down steel water tubing and connection 15 mm bore in pipe , complete all as directed. |
| 63 | Taking up or down steel water tubing and connection 20mm bore in pipe , complete all as directed. |
| 64 | S&F Steel water tubing 15mm bore, medium grade, galvanised, with all fittings and fixed complete to walls and ceilings or laid in floor, complete all as specified and as directed. |
| 65 | S&F Steel water tubing 20mm bore, medium grade, galvanised, with all fittings and fixed complete to walls and ceilings or laid in floor, complete all as specified and as directed. |
| 66 | Fixing only old serviceable galvanized iron pipe 15mm bore in new or old position with new fittings as in wall and ceiling or laid in floors, complete all as specified and as directed.Note:- Old Serviceable pipe obtained from item No 62 shall be reused |
| 67 | M&L Cleaning and removing all Scales and dirts from the Tank and mouths of circulating Pipes, etc. after draining out Water from the Tank of capacity exc. 250 Litre and not exc. 500 Litre, cleaning the Tank by scrubbing the deposits with Wire Brush, re-fixing Inlet and Outlet Pipes in the Same Position and writing Letters CLEANED ON DD.MM.YYYY (Date) not exc. 50mm in height, complete all as specified and as directed. |
| 68 | M&L Cutting into existing manholes for connecting new Drains Pipe 150mm bore, making good to pipes and rendering, cutting out existing benching for and forming Branch Channel (½ Round or ¾ Section) in Cement Concrete 1:2:4 (20mm graded aggregate),Smooth finished and Reforming Benching as required,complete all as specified and as directed. |
| 69 | Cleaning of blocked water closet (of any type / pattern) includingconnected pipe line (of any bore) upto 1st manhole as complete all as directed. |
| 70 | Cleaning of blocked nahni / floor trap (of any size /type) includingconnected pipe line (of any bore) upto gully trap/1st manhole complete all as directed. |
| 71 | M&L Cleaning GULLY TRAP (Manhole type), depth not exc. 0.50 METRE by opening Cover and taking out accumulated Garbage, Brick Bats, Silts or any other Items, re-fixing the Cover after cleaning of Gully Trap, removing and carrying Brick Bats, Garbage, Silts, etc. to a distance exc 50 Metre but not exc 100 Metre and burried (minimum 50 Cm below Normal Ground Level) by Excavating of Earth Pits and returning, filling in, dressing of surplus Soils and providing ground to Slope as required/ ordered, complete all as specified and as directed. |
| 72 | M&L Cleaning GULLY TRAP (Manhole type), depth exc. 0.50 METRE and not exc. 1.00 METRE by opening Cover and taking out accumulated Garbage, Brick Bats, Silts or any other Items, re-fixing the Cover after cleaning of Gully Trap, removing and carrying Brick Bats, Garbage, Silts, etc. to a distance exc 50 Metre but not exc 100 Metre and burried (minimum 50 Cm below Normal Ground Level) by Excavating of Earth Pits and returning, filling in, dressing of surplus soils and providing ground to Slope as required/ordered, complete all as specified and as directed.Note for Srl Item No 70, 71, 72 & 73:-(i) The quoted rate of contractor shall comprise the following:-(ii) The contractor/his representative must collect the complaint slip from complaint cell (MES) at AF Station Missamari within a time period of 9.00AM to 11.00 AM on all working days of MES.These complaints must be attained and completed satisfactorily within 48 hrs of its receiving all as directed by Engineer-in-Charge.(iii) After rectification/completion of complaints, complaint slip duly signed by user shall be submitted to Engg-in-charge and shall be must be submitted alongwith the RAR/Final Bill for payment. (iii) If the contractor fails to complete the complaints within the stipulated time, he will be penalised at a rate of Rs. 250 per 12 hrs and decission of GE shall be full and final and no representation shall be entertained at later stage. |
| 73 | M&L Cleaning MANHOLE, depth not exc. 0.50 METRE, by opening Cover and taking out accumulated Brick Bats, Garbage, Silts or any other Items, re-fixing the Cover after cleaning of Manhole, removing and carrying Brick Bats Garbage, Silts, etc. to a distance exc. 50 Metre but not exc. 100 Metre and burried (minimum 50 Cm below Normal Ground Level) by Excavating of Earth Pits and Returning, Filling in, Dressing of surplus Soils and providing ground to Slope, etc., (as required /ordered at Site), complete all as specified and as directed. |
| 74 | M&L Cleaning MANHOLE, depth exc. 0.50 METRE and not exc. 1.00 METRE, by opening Cover and taking out accumulated Brick Bats, Garbage, Silts or any other Items, re-fixing the Cover after cleaning of Manhole, removing and carrying Brick Bats Garbage, Silts, etc. to a distance exc 50 Metre but not exc. 100 Metre and burried (minimum 50 Cm below Normal Ground Level) by Excavating of Earth Pits and Returning, Filling in, Dressing of surplus Soils and providing ground to Slope, etc., (as required /ordered at Site), complete all as specified and as directed. |
| 75 | M&L Cleaning MANHOLE, depth exc. 1.00 METRE and not exc. 2.00 METRE, by opening Cover and taking out accumulated Brick Bats, Garbage, Silts or any other Items, re-fixing the Cover after cleaning of Manhole, removing and carrying Brick Bats Garbage, Silts, etc. to a distance exc 50 Metre but not exc. 100 Metre and burried (minimum 50 Cm below Normal Ground Level) by Excavating of Earth Pits and Returning, Filling in, Dressing of surplus Soils and providing ground to Slope, etc., (as required /ordered at Site), complete all as specified and as directed. |
| 76 | M&L Cleaning MANHOLE, depth exc. 2.00 METRE and not exc. 3.00 METRE, by opening Cover and taking out accumulated Brick Bats, Garbage, Silts or any other Items, re-fixing the Cover after cleaning of Manhole, removing and carrying Brick Bats Garbage, Silts, etc. to a distance exc 50 Metre but not exc. 100 Metre and burried (minimum 50 Cm below Normal Ground Level) by Excavating of Earth Pits and Returning, Filling in, Dressing of surplus Soils and providing ground to Slope, etc., (as required /ordered at Site), complete all as specified and as directed. |
| 77 | M&L Cleaning MANHOLE, depth exc. 3.00 METRE and not exc. 4.00 METRE, by opening Cover and taking out accumulated Brick Bats, Garbage, Silts or any other Items, re-fixing the Cover after cleaning of Manhole, removing and carrying Brick Bats Garbage, Silts, etc. to a distance exc 50 Metre but not exc. 100 Metre and burried (minimum 50 Cm below Normal Ground Level) by Excavating of Earth Pits and Returning, Filling in, Dressing of surplus Soils and providing ground to Slope, etc., (as required /ordered at Site), complete all as specified and as directed. |
| 78 | M&L Cleaning SEPTIC TANK 10 USERS by opening Cover, Pumping out Sewage Water and taking out accumulated Night Soils, Sludges, Brick Bats or any other Items, re-fixing the Cover after cleaning of Septic Tank, removing and carrying Night Soils, Sludges, Brick Bats, etc. to a distance exc. 50 Metre but not exc. 100 Metre and burried (minimum 50 Cm below Normal Ground Level), Sprinkling Bleaching Powder on deposited Sludges at Earth Pit including Excavating of Earth Pits and Returning, Filling in, Dressing of surplus Soils and providing ground to Slope, etc., (as required /ordered at Site), complete all as specified and as directed. |
| 79 | M&L Cleaning SEPTIC TANK 25 USERS by opening Cover, Pumping out Sewage Water and taking out accumulated Night Soils, Sludges, Brick Bats or any other Items, re-fixing the Cover after cleaning of Septic Tank, removing and carrying Night Soils, Sludges, Brick Bats, etc. to a distance exc. 50 Metre but not exc. 100 Metre and burried (minimum 50 Cm below Normal Ground Level), Sprinkling Bleaching Powder on deposited Sludges at Earth Pit including Excavating of Earth Pits and Returning, Filling in, Dressing of surplus Soils and providing ground to Slope, etc., (as required /ordered at Site), complete all as specified and as directed. |
| 80 | M&L Cleaning SEPTIC TANK 50 USERS by opening Cover, Pumping out Sewage Water and taking out accumulated Night Soils, Sludges, Brick Bats or any other Items, re-fixing the Cover after cleaning of Septic Tank, removing and carrying Night Soils, Sludges, Brick Bats, etc. to a distance exc. 50 Metre but not exc. 100 Metre and burried (minimum 50 Cm below Normal Ground Level), Sprinkling Bleaching Powder on deposited Sludges at Earth Pit including Excavating of Earth Pits and Returning, Filling in, Dressing of surplus Soils and providing ground to Slope, etc., (as required /ordered at Site), complete all as specified and as directed. |
| 81 | M&L Cleaning SEPTIC TANK 100 USERS by opening Cover, Pumping out Sewage Water and taking out accumulated Night Soils, Sludges, Brick Bats or any other Items, re-fixing the Cover after cleaning of Septic Tank, removing and carrying Night Soils, Sludges, Brick Bats, etc. to a distance exc. 50 Metre but not exc. 100 Metre and burried (minimum 50 Cm below Normal Ground Level), Sprinkling Bleaching Powder on deposited Sludges at Earth Pit including Excavating of Earth Pits and Returning, Filling in, Dressing of surplus Soils and providing ground to Slope, etc., (as required /ordered at Site), complete all as specified and as directed. |
| 82 | Cleaning of sewage lineof 100/150mm bore either manually (by pushing a piece of bamboo split, tied with gunny bags at one end from one manhole to another manhole) or by mechanically operated pump includingdewatering, desilting and well flushing the line with water and testing on completion complete as directed |
| 83 | Cleaning of sewage lineof 200/300mm bore either manually (by pushing a piece of bamboo split, tied with gunny bags at one end from one manhole to another manhole) or by mechanically operated pump includingdewatering, desilting and well flushing the line with water and testing on completion complete as directed |
| 84 | M&L Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) as in Foundations, including rafts,footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete including demoliation of existing unserviceable concrete and removing debries of the site complete all as specified and as directed. |
| 85 | M&L Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) as in Columns, pillars, piers, posts and struts including demoliation of existing unserviceable concrete and removing debries of the site complete all as specified and as directed. |
| 86 | M&L Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and inshelves and the like including demoliation of existing unserviceable concrete and removing debries of the site complete all as specified and as directed. |
| 87 | M&L Form work for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, flat, rough finished surfaces of concerete complete all as specified and directed. |
| 88 | M & L Form work for sides of pillars, posts, columns & similar works, square rectangular or polygonal flat, rough finished surfaces of concerete complete all as specified and directed. |
| 89 | M & L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping) flat, rough finished surfaces of concerete complete all as specified and directed. |
| 90 | M&L Cement Concrete 1:4:8 (40mm graded aggregate) in Foundations, Filling and Mass Concrete including use and waste Formwork as ordered/required at Site, complete all as specified and as directed. |
| 91 | S&F in repair PVC (SWR) 110mm bore (dia) bend with Access Door, Jointing with Solvent Cement, complete all as specified and as directed. |
| 92 | S&F in repair PVC (SWR) 110mm bore (dia) Junction Single (Single T) Equal or Unequal Jointing with Solvent Cement complete all as specified and as directed. |
| 93 | S&F in repairPVC (SWR) 110mm bore (dia) Junction Single (Single T) Equal or Unequal with Access Door, etc. Jointing with Solvent Cement, complete all as specified and as directed. |
| 94 | S&F in repair PVC (SWR) 110mm bore (dia) PVC (SWR) branch piece, double (double Y) equal or unequalJointing with Solvent Cement complete all as specified and as directed. |
| 95 | S&F in repair PVC (SWR) 110mm bore (dia) PVC (SWR) branch piece, double (double Y) equal or unequal with Access Door, etc. Jointing with Solvent Cement complete all as specified and as directed. |
| 96 | S&F in repair PVC (SWR) 110mm bore (dia) PVC (SWR) vent cowl, complete all as specified and as directed. |