| 1 | Divider paint work & Reparing |
| 2 | Dismentling reinforced cement concrete or reinforced b/w incuding stacking of materials as directed by engineer-in-charge within a distance of 60 metre.(SI. No 694/2022) SOR |
| 3 | 12mm thick cement plaster with 1:4 cement and fine sand of 1.25 FM mortar over brick work minimum thickness not to be less than 1cm including supply of all material, labour, tools and plants etc, required for proper completion of the work as per direction of Engineer-in-charge. (SI.No.584)/2022 |
| 4 | Scraping old white or colour wash includingdisposal of refuse as directed by the Engineer-in-charge within a distance of 60 metre (200 feet).( S.I. No 708/2022) SOR |
| 5 | Providing wall putty on old surface with approved quality material of Berger/J.K./ Birla or similar make 2 coats.(S.I.No. Ch no-15/new item/2022)SOR |
| 6 | Finishing wall with 2 coats weather paint of approved make & quality on new work with two coats to given an even shade including supply of all material, labour, tools and plant etc. required for completion of the work.[SI No. new items of Ch-15] |
| 7 | Excavation in foundation in ordinary soil (loam, clay or sand) including lift upto 1.50 M lead upto 30 M and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by Engineer-in-charge upto a distance of 30 M from the foundation trenches. (S.I. No. 251a) /2022 |
| 8 | Concrete with 4cm. gauge brick ballast, coarse sand of 2.20 F.M and cement in proportion of 8:4:1 in foundation and under floors, including supply of all materials, labour, T&P etc. required for proper completion of the work.(SI.No.281/2022) |
| 9 | RCC work with cement, approved Coarse sand and 40mm stone grit in proportion of 1:1.5:3 in raft and foundation excluding supply of reinforcement and its bending but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and supply of all materials, labour, T&P etc. required for proper completion of the work, including cost of binding wire. (S.I. No. 287a/2022) |
| 10 | M.S (Tor steel or plain) work in plain work such as RCC or RB work including bending for proper shape and including supply of steel and its wastage, bend, hooks and authorized over lapping shall be measured and including cost of binding wire (S.I. No. 504/2022) A.R. |
| 11 | M.S.iron work of small size and section such as holding down bolts, hold fast, tie roads grating etc. wrought to required from including supply of steel bolts, nuts wastage etc. and their fixing required for proper completion of the work. S.I.NO.....502(a)/2022 |
| 12 | Electrical work |
| 13 | Supply of Decorative Pole Mild Steel with a total height of 8 mtr above ground level with double arm bracket of street light 200W each and predefined pattern in between the top portion of the pole. Pole bottom base section shall be shall be 400x200x1000mm, 4mm thickness column with two side predesigned laser cut to illuminate the surroundings in 20W with noticeable mode, next section embedded with double pole of 76x7000x3mm with golden casting embellishment with illuminated laser cut pattern design of bracket of 3000mm long to hold the street light. The base plate of pole shall be of size 600x350x12mm. The Approximate weight of the pole is 165kg +-5% Provision for inside termination box with 4way connector & 1 nos 6 Amp MCB for local isolation.The pole and light fixture is primarily coated with primer, secondary epoxy resin and top coated with UV stabilized powder coat and cured. The decorative pole is suitable for outdoor lighting applicationą.(as per attached drawing and Engineer Incharge) |
| 14 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core ,SI.No.501(i)/Elec.2018 |
| 15 | S/F of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge.(SI.No.504C/2018) SOR |
| 16 | S/F of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with Cts etc. in case of TPN complete in all respect. 40 amp TPN (SI.No.807f(ii)/2018) SOR |
| 17 | S/L of copper wire (SI.No.1.17.12/2022)DSR Elec. |
| 18 | Supply and burying earth eletrode for lighting conductor of 600 mm x 600mm x 3mm copper plate vertically with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe for watering funnel, 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per direction of the Engineer-Incharge.(SI.No.708/2018)Elec. SOR |
| 19 | S/L of follwing size DWC HDPE pipe (OD-63 mm & ID 51 mm nominal)DSR SI.No.14.16.1/2022/Elec. E-file No. MZDA.ENGG O BILL/47/2025-ENGG-MZDA Please Enable Macros to View BoQ information |