| 1 | Dismantling of single layer Mangalore pattern roofing tiles including ridges and hips, complete all as specified and directed. |
| 2 | M&L for rolled mild steel roof trusses (framed), including trussed purlins, rails, bracings, fastenings and heavy brackets framing (beams, tees, angles, channels or flat sections), including distance pieces, cleats etc., conforming to Fe-290 (Grade E-165), complete all as specified and directed. |
| 3 | S&F pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50 mm thick (Mangalore pattern type), of approved colour and tensile strength 550 MPa, as roof covering/cladding/ridge to wall, fixed with self-tapping screws, complete all as specified and directed. |
| 4 | S&F plain galvanised mild steel sheeting 0.63 mm thick in ridges, hips, valley gutters, drip and straight flashings (length and girth as required) with zinc coating 275 gsm, complete all as specified and directed. |
| 5 | M&L for applying two coats of SmartCare Damp Proof by roller/brush over one coat of primer (SmartCare Damp Proof @ 33% dilution), including thorough preparation of existing surface by removal of all old treatment, chipping loose mortar, cleaning with wire brush and water washing, including filling and coving with SmartCare Repair Mortar and sealing cracks with SmartCare Crack Filler where required, complete all as per manufacturer’s instructions and as specified and directed. Make: Asian Paints SmartCare Damp Proof or equivalent in Nerolac, Shalimar, Jenson & Nicholson and Berger.Note:The work shall be executed by authorised applicator of the approved manufacturer and shall conform to relevant IS Codes and manufacturer’s specifications. |
| 6 | Removing the existing APP membrane laid over concrete surface, including complete cleaning of the surface free from dirt, dust, laitance and loose materials using wire brush, grinding machine and water jet machine and allowing the surface to dry thoroughly, opening all visible cracks, if any, in V/U shape using electrically operated cutting machine, cleaning the same with wire brush and air blower and treating with approved crack filler, thereafter opening and removing all debonded and unsound concrete portions in terrace areas, cleaning the same and applying one coat of bonding agent such as Home Shield Advance Latex Plus or equivalent directly over the prepared surface and allowing it to dry for minimum 30 minutes and refilling the repaired areas using cement, sand, water and polymer bonding compound mix to achieve proper bonding with the old surface and to ensure correct slope and flow of water towards outlets, supplying and applying one coat of bonding primer such as Berger Home Shield Super Latex Plus or equivalent over the cleaned surface and allowing it to dry for 2 to 3 hours for proper penetration and sealing of surface porosity, followed by supplying and applying water based elastomeric PU waterproofing membrane having excellent crack bridging and waterproofing properties such as Berger PU Roofkoat or equivalent, in two coats, one applied vertically and the other horizontally, over the concrete surface including terrace and parapet walls, to achieve seamless and durable waterproofing complete all as specified and directed.Note:The work shall be executed by authorised applicator of the approved manufacturer and shall conform to relevant IS Codes and manufacturer’s specifications. |
| 7 | Taking down cement plaster from wall/ceiling surfaces of any description including raking out joints, hacking for key and scrubbing down with water, complete all as specified and directed. |
| 8 | M&L for rendering 15 mm thick in CM 1:4 on fair faces of concrete surfaces, finished even and smooth without using extra cement, mixed with approved waterproofing compound @ 1% by weight of cement or as per manufacturer\"s instruction, whichever is higher, complete all as specified and directed. |
| 9 | Supply only integral waterproofing compound complete all as specified and directed. |
| 10 | M&L for two coats of acrylic smooth exterior emulsion paint of approved shade over newly plastered surfaces @ 1.67ltr/ 10 Sqm including one coat of exterior primer @ 2.20 kg/ 10 Sqm, including surface preparation, complete all as specified and directed. |
| 11 | M&L for preparation of new steel surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 12 | Taking up or down steel tubing and connections of 25 mm bore including cleaning and removal to store, complete all as specified and directed. |
| 13 | Taking up or down GI tubing and connections of 20 mm bore including cleaning and removal to store, complete all as specified and directed. |
| 14 | S&F 25 mm dia UPVC pipes of pressure rating 10 kgf/cm² fixed to walls, ceiling or floors including fittings and clamps, complete all as specified and directed. |
| 15 | S&F 20 mm dia UPVC pipes of pressure rating 10 kgf/cm² fixed to walls, ceiling or floors including fittings and clamps, complete all as specified and directed. |
| 16 | Dismantling of PVC/ RCC water storage tank exceeding 500 litre but not exceeding 1000 litre capacity including removal of rubbish outside MoD land, complete all as specified and directed. |
| 17 | S&F rotational moulded PVC, triple-layered water storage tank of 1000 litre capacity (cylindrical vertical with closed top), ISI marked, hoisted and fixed in position including tank cover with lock arrangements and all necessary fittings, complete all as specified and directed. |
| 18 | Taking down eaves gutters and rainwater pipes of any size or pattern including all fittings, heads, shoes, bends and swan-necks, complete all as specified and directed. |
| 19 | M&L for PVC rainwater pipe 110 mm dia, single socketed, in any length, with rubber ring joints, fixed to wall including clamps and fittings, complete all as specified and directed. |
| 20 | S&F 110 mm dia PVC bends complete all as specified and directed. |
| 21 | S&F in repair 25 mm dia high pressure PTMT ball valve with epoxy coated aluminium rod and high density plastic ball, ISI marked (minimum weight 455 gms), screwed and suitable for iron pipe 25 mm bore, complete all as specified and directed. |
| 22 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons,dados etc laid, bedded and pointed in any mortar and removal of rubbish off the site complete all as specified & directed. |
| 23 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for . |
| 24 | Demolition of PCC block or stone masonry built in cement mortar including all quoines arches,pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles, all asspecified . |
| 25 | S&F 20mm Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite as per specified and directed |
| 26 | S&F in repair Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchenor laboratory with plug, washers waste pipe, cast iron cantilever brackets,connecting union overall size 915mmx460mm with bowl size 410mm x 330mm x 160mm complete all specified and directed. |
| 27 | Taking up or down steel tubing 15mm bore of pipe and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 28 | S&F GI tubing 15mm bore medium grade medium grde with all fittings and fixed complete to wall and ceilingor laid in floorscomplete all as specified and directed. |
| 29 | S&F in repairs Pillar taps, cast copper alloy, Fancy type, chromium plated with capstan heads, screwed down high pressure, with or long screwed shanks and fly-nuts, screwed for iron pipe of 15mm bore of complete all as specified and directed. |
| 30 | S&F in repairs brass chromium plated mixer for mixing hot & cold water screwed down for 15mm dia iron pipe of complete all as specified and directed. |
| 31 | M&L for preparation of old decoratedplastered or unplastered surface of walls and applying two coats of oil bound emulsion distemper with primer of any tint complete all as specifed and as directed. |
| 32 | Dismantling floor, hearth or wall tiling including cement mortar bedding( but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 33 | M&L for non skid coloured ceramic tiles 7 mm to 8 mm thick area of eah tile exc 0.11 Sqm but not exceeding 0.18 Sqm in floors, set jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer of cement mortar 1:6 etc complete all as specified and directed. |
| 34 | M&L for glazed coloured ceramic tiles in vertical surfaces, size 350 x 250 x 7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match, including backing coat of 10 mm thick cement plaster in CM 1:4 for laying dado/skirting tiles, complete all as specified and directed. |
| 35 | Supply, design, fabrication, delivery and fixing of pre-fabricated complete modular kitchen system as per approved layout drawings and BOM, comprising base units, wall units, blind corner units, sink unit, microwave cabinet, fillers and accessories, manufactured using factory-finished moisture resistant HDF pre-laminated boards, complete with shutters, carcass, internal shelves, drawers, partitions, fittings, fixtures and testing for satisfactory performance, complete all as specified and directed.All carcass and shutters shall be manufactured from factory-finished moisture resistant HDF pre-laminated boards of minimum 18 mm thickness , forming the rigid structural body of each cabinet including sides, base, top and back panels, complete with internal partitions as required, with finish shade and texture as specified in the BOM approved by GE. All exposed edges shall be machine sealed with minimum 2mm thick PVC edge banding. Back panels shall be 8 mm thick HDF and drawer bottoms shall be 6 mm thick HDF.All shutters shall be provided with soft-close concealed hinges having 35 mm cup diameter and minimum 110° opening. Drawer systems shall be soft-close telescopic type. Handles shall be Amazon CP 160 mm as per BOM. Adjustable legs shall be heavy duty type minimum 100 mm height and concealed with Scilm Skirting 100 mm black finish with corner profile and connector as per approved system. |
| 36 | The kitchen shall include complete supply and fixing of the following Sleek modular units as per approved BOM schedule and drawings:Base cabinets including Right Blind, Left Blind, Sink base, Cutlery system, Basket unit, Drawer systems and additional panels.Wall cabinets including drain tray type, microwave cabinet with lift-up flap.Base fillers and wall fillers of specified widths as per design drawings.Microwave cabinet fitted with Free Flap Forte Type A (HILP5103) mechanism or equivalent.Internal accessories including Kitchen Hardware Packet , SS Bin Holder and SS Detergent Pull-out .Providing and fixing Black Velvet polished granite countertop of minimum 18 mm thickness, laid over WPC board backing, including bull-nosed edges, cut-outs for sink and chimney as per Worktop Plans, sealing of joints with food-grade silicone sealant, polishing, alignment and finishing complete.Supply and fixing of stainless steel single bowl sink with drain board integrated into counter top as shown in Worktop Plan, made of minimum 1.0 mm thick stainless steel sheet, complete with waste coupling, strainer, CP brass bottle trap, PVC waste pipe, fixing brackets and all necessary fittings, fixed flush with countertop and tested complete.Supply and fixing of electric ducted type kitchen chimney GRACE PLUS BLACK 75CM (Model HMAPICGRACBL75) or equivalent including mounting brackets, exhaust ducting, wiring, electrical connection and commissioning complete.Notes:(i) The quoted rate shall include site visit, measurement, coordination, preparation of layout drawings & shop drawings, design, supply of all requisite materials, specialised labour/technicians, tools and machineries, transportation, fixing arrangements, minor making good, alignment, levelling, installation, anchoring, edge sealing, testing, cleaning and handing over in ready-to-use condition.(ii) The work shall be executed by authorised applicator of the approved manufacturer as per manufacturer’s recommendations and approved drawings and shall conform to relevant IS Codes.(iii) All dimensions, module sizes, finishes, accessories and mechanisms shall match the BOM and design drawings approved by GE.Make : Sleek by Asian Paints or equivalent as approved by Garrison Engineer. |